Search NASA⌕ Search

SEARCH · Search NASA

Results for “Building HVAC control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Packages of Distributed Energy Technologies Demonstrating Demand Flexibility at Community Scale

The combination of increased electric load growth across all sectors, deferred electrical infrastructure investment, and other factors resulting in variable electric power supply, has created technical challenges to maintaining a resilient and reliable grid. Many federal, regional, and local efforts are in play to modernize the electric grid, including advancing building technologies and distributed energy resources (DERs) that are utilizing smarter controls to become responsive to both occupant and grid needs. This report reviews ten pilot projects demonstrating how groups of buildings combined with behind-the-meter (BTM) DERs such as electric vehicle (EV) charging, battery storage, flexible HVAC and domestic hot water systems, and photovoltaic systems can reliably and cost effectively provide grid services. Each of the ten pilot projects aim to deliver both energy efficiency and demand flexibility (DF) while supporting load growth. The ten demonstration teams are piloting flexible DER packages across diverse communities of residential and commercial buildings to address a variety of regional grid needs. The outcomes of these pilot projects will be used to inform future scaling through utility program development. This paper characterizes the ten teams, showcasing the decision-making process used by each group to develop their packages (Section 2), the grid services they plan to deliver (Section 3), the types of DER packages selected for deployment within building sectors (Section 4) and trends between building sector, DER types, and grid services In order to achieve community scale benefits, the pilot projects must utilize aggregated control mechanisms for coordinating buildings and DERs together. Several types of coordinated control architectures have evolved amongst the teams, influenced by use type, existing market conditions, and integration type. Three coordinated controls architectures have been characterized, highlighting their use cases, benefits, challenges, and tradeoffs in their design. These insights can aid utilities, control vendors, and developers in scaling community-level energy systems (Paul, 2024). Ultimately, the technology packages selected by the ten teams will be coordinated to provide power system services, also known as grid services. Insights from these demonstrations will be useful for grid operators, regulators, aggregators and other stakeholders as they look to deploy demand flexible resources as grid services in the future. The grid services that each team is targeting for demonstration are described in Section 3 and Section 4. Methods for evaluating the grid services have been described in the paper Metrics for Evaluating Grid Service Provision from Communities of Grid-interactive and Efficient Buildings and other DER (MacDonald, 2023). To identify technology packages for demonstration, Section 2 shows that project teams used a range of analysis approaches, including building energy modeling, AMI data analysis, cost-benefit frameworks, and utility pilot data. Some teams emphasized technical modeling to quantify grid impacts and demand reduction potential, while others prioritized economic evaluations, stakeholder input, or exploratory pilots to inform deployment decisions. This diversity reflects the need to tailor selection methods to project goals, available data, and organizational context. Section 5 discusses trends between the DER technologies deployed and the grid service provisions from each team. Residential buildings (multifamily and single family) lean towards technologies that enhance energy efficiency (e.g. weatherization upgrades, smart thermostats) and onsite power generation integration (e.g. solar PV). Commercial building demonstrations prioritize technologies that ensure operational reliability (e.g. battery storage) and centralized energy management systems and optimization solutions. Teams that are deploying controllable storage-based technologies are more likely to provide grid services that require a near real-time response. Teams incorporating load shifting technologies like smart thermostats with HEMs are likely to include energy markets participation and customer bill management offerings. Campus demonstrations are adopting diverse sets of DERs to emphasize renewable generation, paired with centralized control. This section also describes technologies that were considered during project planning but ultimately excluded from final deployment. These demonstrations reveal that effective DER package design should be tailored to building type, customer segment, and construction vintage. Multifamily buildings benefit from centralized HVAC upgrades and supervisory controls, while single-family homes are well-suited for individualized technologies like solar, storage, and smart home energy monitors. Commercial and campus settings prioritize EMIS integration and load optimization. New construction enables cost-effective integration of DER-ready infrastructure, whereas retrofits require deployments aligned with owner and tenant value streams. For utility program planners, early coordination with developers and building owners, paired with segmented and modular program offerings, can improve adoption, scalability, and grid impact.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Intelligent multi-zone residential HVAC control strategy based on deep reinforcement learning

Residential heating, ventilation, and air conditioning (HVAC) has been considered as an important demand response resource. However, the optimization of residential HVAC control is no trivial task due to the complexity of the thermal dynamic models of buildings and uncertainty associated with both occupant-driven heat loads and weather forecasts. In this paper, we apply a novel model-free deep reinforcement learning (RL) method, known as the deep deterministic policy gradient (DDPG), to generate an optimal control strategy for a multi-zone residential HVAC system with the goal of minimizing energy consumption cost while maintaining the users’ comfort. Here, the applied deep RL-based method learns through continuous interaction with a simulated building environment and without referring to any prior model knowledge. Simulation results show that compared with the state-of-art deep Q network (DQN), the DDPG-based HVAC control strategy can reduce the energy consumption cost by 15% and reduce the comfort violation by 79%; and when compared with a rule-based HVAC control strategy, the comfort violation can be reduced by 98%. In addition, experiments with different building models and retail price models demonstrate that the well-trained DDPG-based HVAC control strategy has high generalization and adaptability to unseen environments, which indicates its practicability for real-world implementation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Peak load reduction and load shaping in HVAC and refrigeration systems in commercial buildings by using a novel lightweight dynamic priority-based control strategy

Reducing peak power demand in a building can reduce electricity expenses for the building owner and contribute to the efficiency and reliability of the electrical power grid. For the building owner, reduced expenses come from the reduction or elimination of peak power charges on electricity bills. For the power system operator, reducing peak power demand leads to a more predictable load profile and reduces stress on the electric grid system. Herein we present a computationally inexpensive, dynamic, and retrofit-deployable control strategy to effect peak load reduction and load shaping. The effectiveness of the control strategy is examined in a simulation with 80 air-conditioning units and 40 refrigeration units. The results show that a peak demand reduction of 60 kW can be achieved relative to peak demand in a typical set point–based approach. The proposed strategy was deployed in a gymnasium building with four rooftop HVAC units, where it showed over 15% peak demand (kW) reduction savings while maintaining or lowering energy consumption (in kilowatt-hours) relative to the set point–based thermostat controls.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Potential Cooling Energy Savings of Economizer Control and Artificial-Neural-Network-Based Air-Handling Unit Discharge Air Temperature Control for Commercial Building

Heating, ventilation, and air-conditioning (HVAC) systems play a significant role in building energy consumption, accounting for around 50% of total energy usage. As a result, it is essential to explore ways to conserve energy and improve HVAC system efficiency. One such solution is the use of economizer controls, which can reduce cooling energy consumption by using the free-cooling effect. However, there are various types of economizer controls available, and their effectiveness may vary depending on the specific climate conditions. To investigate the cooling energy-saving potential of economizer controls, this study employs a dry-bulb temperature-based economizer control approach. The dry-bulb temperature-based control strategy uses the outdoor air temperature as an indicator of whether free cooling can be used instead of mechanical cooling. This study also introduces an artificial neural network (ANN) prediction model to optimize the control of the HVAC system, which can lead to additional cooling energy savings. To develop the ANN prediction model, the EnergyPlus program is used for simulation modeling, and the Python programming language is employed for model development. The results show that implementing a temperature-based economizer control strategy can lead to a reduction of 7.6% in annual cooling energy consumption. Moreover, by employing an ANN-based optimal control of discharge air temperature in air-handling units, an additional 22.1% of cooling energy savings can be achieved. In conclusion, the findings of this study demonstrate that the implementation of economizer controls, especially the dry-bulb temperature-based approach, can be an effective strategy for reducing cooling energy consumption in HVAC systems. Additionally, using ANN prediction models to optimize HVAC system controls can further increase energy savings, resulting in improved energy efficiency and reduced operating costs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

When Do Efficiency and Demand Flexibility Go Hand-in-hand?

Utilities have been experimenting with integrated demand side management (IDSM) programs since the 2000s. The potential benefits of improved program cost-effectiveness and customer engagement from combining energy efficiency (EE), demand flexibility (DF), and other distributed energy resources into an integrated customer offering have been recognized although there are several known regulatory and program administrative challenges. In addition, as buildings adopt EE measures, the baseline load profile change generally reduces the potential load that can be shed or shifted. This has been a significant technical barrier for customers and program implementers. However, it is a myth that EE always reduces DF. Load change from EE can be time-varying. Therefore, whether EE improves or reduces DF should be evaluated on an individual measure basis accounting for weather dependencies and interactions. For IDSM program design purpose, it is useful to understand how common EE features influence DF and the underlying building physics. In this paper, we use parametric simulations of a prototype medium office building to evaluate how various EE features influence DF, measured by a “demand decrease intensity” (W/ft2) metric. These EE features cover envelope characteristics, internal loads, and airside HVAC system. The parametric analysis shows that some efficient HVAC control measures will increase DF but not the traditional building envelope, lighting, and ventilation-related efficiency measures. These findings contribute to the technical basis for achieving enhanced energy benefits by packaging appropriate HVAC control measures in IDSM program design. Program developers should further validate these results in targeted pilot projects.

Yu, Lili↗

Lifting the Garage Door on Spawn, An Open-Source BEM-Controls Engine

Spawn is the latest whole-building energy simulation engine developed by the US Department of Energy, National Labs and industry. Whereas EnergyPlus was designed as a successor to DOE-2, Spawn is not a direct successor of–nor is it intended as an imminent replacement for– EnergyPlus. Instead, Spawn reuses parts of EnergyPlus while supporting new use cases in HVAC and controls. Spawn is intended to provide several capabilities that significantly advance beyond EnergyPlus. It is intended to support the evaluation of novel HVAC and district energy systems in a more physically realistic way. Critically, it can model control in a physically realistic way, using portable specifications that can be compiled for execution on control platforms. Spawn is also intended to support co-simulation in an intrinsic way to enable integration with third-party models. This paper describes the software architecture of Spawn from model authoring to compilation and simulation. It explains how Spawn reuses the envelope and daylighting modules of EnergyPlus and couples them to HVAC and control models from the Modelica Buildings Library using the Functional Mockup Interface (FMI) standard. It presents a number of examples that: i) validate Spawn’s coupled simulation approach by comparing its results to those of EnergyPlus, ii) illustrate the Spawn methodology for modeling and simulating HVAC systems, and iii) evaluate the performance of Spawn’s Quantized State System (QSS) time integration algorithms

Wetter, Michael↗

Online distributed price-based control of DR resources with competitive guarantees

Demand response (DR) of building HVAC load can provide crucial demand-side flexibility for the future smart grid. Compared to direct load control, price-based control can respect the customers’ autonomy and privacy. However, it is challenging for price-based control to attain provable performance guarantees under future uncertainty. In this paper, we propose a framework for a utility to perform price-based control of flexible building load within the utility’s service area, in order to attain competitive performance guarantees in terms of controlling the system peak demand under future uncertainty. By adopting a two-step approach, our online price-based control solution can attain a provable competitive ratio for all possible realizations within a given uncertainty set. Simulation experiments demonstrate that, with a robustification procedure, our solution can perform well not only for worst-case inputs, but also for average-case inputs.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Coordinated Optimal Control of PV Inverters and HVAC Loads in Distribution Systems

The increasing integration of distributed energy resources (DERs), such as photovoltaics (PVs) and smart buildings into distribution systems complicate power system operation and controls. This paper proposes a coordinated optimal control strategy for PV inverters and Heating, ventilation, and air conditioning (HVAC) loads in smart buildings to minimize the total network loss in a distribution system. For the HVAC units, we enforce minimum on and off time constraints to avoid frequent switching that can degrade the unit. The proposed control will dispatch optimal control signals of active and reactive power to PV inverters and on/off commands to HVAC units while maintaining the nodal voltage within a secure range and the temperature of HVAC units at a comfort level. The simulation results on a modified IEEE 33-node distribution system demonstrate that the proposed coordinated control scheme can reduce the network loss.

Pani, Naveen↗

Energy Efficiency Package for Tenant Fit-Out: Laboratory Testing and Validation of Energy Savings and Indoor Environmental Quality

Approximately 40% of the total U.S. office floor space of 1.5 billion sq.m (16 billion sq.ft.) is leased space occupied by tenants. Tenant fit-out presents a key opportunity to incorporate energy efficiency within the real estate business cycle. We designed a package of energy efficiency measures tailored to the scope of a tenant fit-out. This tenant fit-out package (TFP) includes advanced lighting and heating, ventilating and air-conditioning (HVAC) controls as core measures, with ceiling fans, automated shading, and plug load controls as additional optional measures. We conducted laboratory testing of six configurations of the package to evaluate energy savings, indoor environmental quality, and identify installation, commissioning, and operational issues. Combined savings for HVAC, lighting, and plug loads ranged from 33–40%. Lighting savings ranged from 69–83%, and HVAC savings from 20–40%. The laboratory testing also revealed some minor but tractable challenges with installation and commissioning of HVAC controls. Overall, the results demonstrate that significant savings can be realized in existing office buildings by incorporating relatively low-risk, proven measures at the time of a tenant fit-out.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Optimizing Control for Efficient Load Shifting with Thermal Energy Storage in Existing HVAC Systems

This project developed the integration of a direct-contact heat exchanger (DCHX) based thermal energy storage (TES) system with a chiller–air handling unit (AHU) plant to evaluate its potential for reducing building energy costs. Detailed physical models of the TES unit, building envelope, and HVAC components were developed alongside simplified control-oriented models to support both high-fidelity simulation and real-time optimization. Two control strategies were implemented and compared: a rule-based control (RBC) aligned with utility time-of-use (ToU) rates, and a model predictive control (MPC) framework leveraging forecasts of building load, weather, and internal gains.Simulation results show that the RBC strategy reduced daily electricity costs by around 30% by shifting cooling production from on-peak to off-peak hours. In contrast, the MPC strategy achieved significantly greater performance, reducing daily operating costs by up to 44% and peak-hour costs by more than 60%. Both strategies maintained indoor thermal comfort within acceptable limits, with MPC further improving load distribution and reducing equipment cycling.The outcomes confirm that TES integration, particularly when coordinated with advanced predictive control, can provide substantial cost savings and on-peak demand reduction. . These findings directly support the U.S. Department of Energy’s goals for grid-interactive efficient buildings and demonstrate the potential of TES-enabled HVAC systems for scalable deployment across the commercial building.

99 GENERAL AND MISCELLANEOUS↗

Optimizing Control for Efficient Load Shifting with Thermal Energy Storage in Existing HVAC Systems

This project developed the integration of a direct-contact heat exchanger (DCHX) based thermal energy storage (TES) system with a chiller–air handling unit (AHU) plant to evaluate its potential for reducing building energy costs. Detailed physical models of the TES unit, building envelope, and HVAC components were developed alongside simplified control-oriented models to support both high-fidelity simulation and real-time optimization. Two control strategies were implemented and compared: a rule-based control (RBC) aligned with utility time-of-use (ToU) rates, and a model predictive control (MPC) framework leveraging forecasts of building load, weather, and internal gains. Simulation results show that the RBC strategy reduced daily electricity costs by around 30% by shifting cooling production from on-peak to off-peak hours. In contrast, the MPC strategy achieved significantly greater performance, reducing daily operating costs by up to 44% and peak-hour costs by more than 60%. Both strategies maintained indoor thermal comfort within acceptable limits, with MPC further improving load distribution and reducing equipment cycling. The outcomes confirm that TES integration, particularly when coordinated with advanced predictive control, can provide substantial cost savings and on-peak demand reduction. . These findings directly support the U.S. Department of Energy’s goals for grid-interactive efficient buildings and demonstrate the potential of TES-enabled HVAC systems for scalable deployment across the commercial building.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

IBPSA Project 2 BOPTEST: An update on the test cases available in the framework for testing advanced control strategies in buildings

Project 2 develops software infrastructure, test cases, and extensions for the Building Optimization Testing Framework (BOPTEST) to address the expanding needs of building and urban energy system controls through open international collaboration. This paper provides an overview of the new test cases available as of BOPTEST version 0.7.1. Each test case is developed using open-source Modelica libraries and Spawn of EnergyPlus, enabling the creation of high-fidelity building models that incorporate envelope dynamics, Heating Ventilation and Air Conditioning (HVAC) systems, and explicit control representations. Currently, eight test cases are available, with five additional cases under development. These test cases cover a wide range of climates, building types, and HVAC systems. This paper compiles and summarizes test case descriptions, cites original manuscripts that developed them for a more detailed description, and reports baseline control performance metrics. Furthermore, two example applications are presented: one illustrating different levels of control, from supervisory to low-level, and another demonstrating how Model Predictive Control (MPC) solutions must be adapted from continuous to integer to control some building actuators.

Zanetti, Ettore↗

Model predictive control of heating, ventilation, and air conditioning (HVAC) systems: A state-of-the-art review

Due to the fast advancement of communication and information technology, intelligent buildings have garnered great interest. These buildings can forecast weather, ambient temperature, and sun irradiation and can modify heating, ventilation, and air conditioning (HVAC) operations appropriately, based on current and previous data. This change is intended to reduce HVAC system energy usage while maintaining an appropriate degree of thermal comfort and indoor air quality. Since its inception, model predictive control (MPC) has been one of the prospective solutions for HVAC management systems to reduce both costs and energy usage. Additionally, MPC is becoming increasingly practical as the processing capacity of building automation systems increases and a large quantity of monitored building data becomes available. MPC also provides the potential to improve the energy efficiency of HVAC systems via its capacity to consider limitations, to predict disruptions, and to factor in multiple competing goals such as interior thermal comfort and building energy consumption. Although substantial research has been conducted on MPC in building HVAC systems, there is a shortage of critical reviews and a lack of a comprehensive framework that formulates and defines the applications. Here, this article provides a comprehensive state-of-the-art overview of MPC in HVAC systems. Detailed discussions of modeling approaches and optimization algorithms are included. Numerous design aspects such as prediction horizon, occupancy behavior, building type, and cost function, that impact MPC performance are discussed in detail. The technical characteristics, advantages, and disadvantages of various types of modeling software are discussed. The primary objective of this work is to highlight critical design characteristics for the MPC control scheme and to give improved suggestions for future research. Moreover, numerous prospective scenarios have been suggested that might provide future research direction.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Towards a Stronger Foundation: Digitizing Commercial Buildings with Brick to Enable Portable Advanced Applications

Most large commercial buildings have digital controls for their heating, ventilation, and air-conditioning (HVAC) and lighting systems with the potential to implement advanced control strategies and data analytics. However, advanced control strategies and data analytics are rarely deployed at scale due to non-standard naming conventions and heterogenous building configurations. Semantic metadata standards, like Brick, show promise to proliferate these applications across many buildings, but they have not been widely adopted by industry due to barriers such as perceived risk and unfamiliarity with the technology. This paper describes the workflow we established and evaluated while using it to develop over ten Brick models of existing buildings. Through this process, we observed that digitizing existing commercial buildings is a cost and labor-intensive effort in which understanding the buildings’ data streams is the major bottleneck. Yet, we conclude this investment is worthwhile since various use case applications such as fault detection and diagnostics, thermal comfort analysis, and HVAC control optimization can utilize the same Brick model. The paper also explores the challenges and lessons learned we encountered while creating these data models, such as: 1) difficulties in finding metadata descriptions and relationships for existing buildings; 2) handling missing concepts in the schema needed to model a building; 3) lack of guidance on how to structure the data model or how much detail to include; 4) unfamiliarity with technologies, which makes the learning curve steep for applications developers. Finally, we also describe future directions for semantic metadata research and development to make such transformative technologies more accessible to practitioners.

Roa, Carlos Duarte↗

Emulation and detection of physical faults and cyber-attacks on building energy systems through real-time hardware-in-the-loop experiments

The increasing use of remote or mobile access, integrated wearable technologies, data exchange, and cloud-based data analytics in modern smart buildings is steering the building industry towards open communication technologies. The increased connectivity and accessibility could lead to more cyber-attacks in smart buildings. On the other hand, physical faults (e.g., HVAC -heating, ventilation, and air-conditioning faults) may have similar adverse impacts as those from the cyber-attacks on building energy systems, such as occupant discomfort, energy wastage, and equipment downtime. However, current physical behavior-based anomaly detection methods fail to differentiate between cyber-attacks and physical faults in building energy systems. Moreover, the challenge in collecting real-world threat data with ground truth has led researchers to rely on numerical models with user-defined assumptions, which may not accurately reflect real-world conditions due to the lack of in-situ experimental datasets. To address these challenges and gaps, this paper presents a flexible hardware-in-the-loop (HIL) testbed for generating cyber-attack and physical fault datasets and demonstrating threat detection algorithms in a real building automation system (BAS) environment. This testbed combines hardware (i.e., real BAS with local HVAC controllers and a physical network) with software (i.e., high-fidelity models to represent behaviors of building envelope and HVAC energy systems), enabling emulations of realistic threats. Five HIL experiments, including one baseline without any threats, two with physical faults, and two with cyber-attacks, were conducted to generate datasets containing detailed network traffic and system states. A joint classification framework, incorporating a network analyzer and a physical HVAC fault detector, was proposed to automatically detect cyber-physical abnormalities on BAS at both the network and the physical HVAC levels. The network analyzer comprises a conditional random fields (CRF) based command validator and a statistics-based detection strategy. The fault detector employs a weather and schedule-based pattern matching and feature-based principal component analysis (WPM-FPCA) method. Evaluation of the classification using four metrics from the multi-class confusion matrix revealed an average accuracy of 90.2%, recall of 89.7%, precision of 88.5% and F1-score of 89.2%. Finally, these results demonstrate that the proposed joint classification framework can effectively differentiate between specific types of cyber-attacks (e.g., device reinitialization attack, network Denial-of-Service attack) and physical faults (e.g., air handling unit operational fault, cooling coil valve stuck) in real time for improved building energy management.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Integrated Spatial, Spectral, & Temporal Optical Reflectance System for Precision Occupancy & Location Sensing to Improve Building Energy Efficiency

Buildings consume approximately 35% of the electricity used in the U.S. and building owners can significantly reduce this energy use by providing services like heating, electrical power and lighting only when people are present. The ARPAe funded program titled “INTEGRATED SPATIAL, SPECTRAL, & TEMPORAL OPTICAL REFLECTANCE SYSTEM FOR PRECISION OCCUPANCY & LOCATION SENSING TO IMPROVE BUILDING ENERGY EFFICIENCY” demonstrates how a low cost sensor technology developed for measuring distances can be used to count and locate occupants with a high degree of precision with a very low error rates. This platform tells a building control system where occupants are located (but not who they are) so that energy consuming services can be provided only when the services are needed by building occupants. The original proof of concept involved using low cost, commercially available time-of-flight (TOF) sensors that measure distance, but the performance of these existing sensors was lacking, as they could not operate properly in the presence of sunlight, which blinded the simple TOF sensors and limited their utility in buildings. This project proposed a powerful new class of TOF sensors that used state-of-the-art integrated circuit (IC) fabrication processes that combined advanced photonics with conventional silicon chip circuitry for improved sensor performance. An equally important part of this project was to find ways to maximize occupant count and location accuracy while using the fewest number of sensors possible, in order to keep costs low. By using building blueprints to create digital twins of commercial building spaces, the team developed new algorithms to maximize occupant count and tracking accuracy by properly locating the minimum number of sensors at just the right spots in the building. This capability not only minimizes system costs but also simplified sensor installation and system commissioning. Our simulations of our sensor networks for a range of commercial floorplan designs demonstrated that our installed cost target of $0.08/sqft was attainable, though not fully demonstrated during the project. Finally, we noted that the TOF sensor concept could provide a valuable role in health and eldercare by tracking patients without the need for worn sensors and would be useful for fall detection and other patient safety metrics, including tracking healthcare/patient interactions. We feel that, when fully developed, this new class of sophisticated TOF sensors and support software will be a powerful new approach to improving building energy efficiency based on occupant centric control platforms and will also open new levels of patient safety in healthcare operations. To realize this potential, the team formed the Troy Sensor Company LLC to oversee licensing of the programs patents and continue to seek commercialization of this program’s activity sensing technologies.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Hamilton: Flexible, Open Source $10 Wireless Sensor System for Energy Efficient Building Operation

Sensors for improving building performance are rapidly populating the market, driven in part by the drive to reduce greenhouse gas emissions resulting from energy production as well as improve the interior environment for healthy and more productive spaces. UC Berkeley has led wireless sensor development over the past 25 years (e.g., Telos mote), with the Hamilton (named after Alexander Hamilton on the US $10 bill) as the most recent. The Hamilton sensor was designed as a low-cost high-performance sensor that is modular and interoperable. The objective of the Hamilton project was to create, evaluate and establish the technological foundations for secure and easy to deploy building energy efficiency applications utilizing pervasive, low-cost wireless sensors integrated with traditional Building Management Systems (BMS), consumer-sector building components, and powerful data analytics. The project included iterative hardware design, incorporating a high-performance database (BTrDb, http://btrdb.io/), creating and iterating the development of secure data middleware (BOSSwave, WAVE/WAVEMQ), working with and pushing the development of an open-source tiny operating system RiotOS, and implementing and improving protocols such as Thread/OpenThread and TCP/IP. The hardware benefited from careful design to drive down the cost; the design included a System-on-a-Chip (SoC), chip antenna, single crystal and five passive components. Careful design of the operating system created a low-power design to enable a long life with small batteries. The hardware included several sensors: temperature, radiant temperature, relative humidity, magnetometer, accelerometer, and light, with an optional occupancy (Passive InfraRed) sensor. The project was the basis of several applications, both internal to the research team and other researchers and professionals at other institutions. Several applications used the sensor hardware as the basis for other complex devices. Other applications used the sensors to improve building performance through interoperating with the building Heating Ventilation and Air-Conditioning (HVAC) system, such as using occupancy and/or distributed temperature sensing to reduce HVAC zone energy while still providing thermal comfort and to reduce peak loads in small commercial buildings. We demonstrated cloud-based energy analytics, implemented a schedule and a Model Predictive Controller in a small commercial building to optimize HVAC energy, occupancy and electricity price. Initial integration of these technological innovations was performed through the creation of execution containers containing the WAVE agent and various driver, proxy, or building system function logic. The research added to the understanding of efficient sensor hardware, secure middleware, time-series data management (high performance database), efficient communication protocols, and interoperating with applications and building systems. The project showed the technical effectiveness and economic feasibility of creating a low-cost, modular, and easy-to-deploy sensor. Through conversations with multiple end users, the research team discovered that many customers wanted data management and services in addition to the sensors. HamiltonIOT developed packages of sensors, border router, and data services to provide a seamless “plug-and-play” sensor deployment. Some customers were willing to pay for higher quality sensors (such as light); some customers wanted a robust enclosure (waterproof).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The Demonstration of Power over Ethernet (PoE) Technologies in Commercial and Institutional Buildings

PoE technologies are currently ubiquitous in offices in the form of phones, access points, and IP security cameras and managed by on-site IT staff. As low voltage DC-power capabilities have increased with network switches, PoE devices are now being integrated across additional building systems, including lighting, computers, and HVAC controls. Since PoE devices are connected to network switches, energy monitoring and management can be performed through the IT network management software. Data and results from technology validations are still very limited for PoE equipment. This lack of information hinders higher adoption as its benefits and challenges have been insufficiently quantified in real-world scenarios. The use of IT network switches to power and control lighting, plug loads, and HVAC were demonstrated at a variety of sites including offices, schools, and a hotel. This paper presents the findings of a three-year DOE-/State of Minnesota-funded project that demonstrated and assessed the energy and non-energy benefits of Power over Ethernet (PoE) technologies at four commercial/institutional sites. The goals of the demonstrations were to: (1) assess the receptiveness of commercial and institutional markets to these new technologies, (2) demonstrate the feasibility of PoE technologies within standard design/construction practices and commercial codes, (3) assess the energy and cost savings opportunities of these technologies, (4) provide energy management opportunities where they typically are not available, and (5) formulate approaches to spur adoption of these technologies in the marketplace.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗