Search NASA⌕ Search

SEARCH · Search NASA

Results for “Building automation system”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

SuperLab 2.0 Showcase: Connecting Five Labs to Tackle Grid Complexity and Unlock Unique Grid Asset Potential

SuperLab 2.0 (a five-lab demonstration) is a collaborative, national-scale experiment showcasing the coordination of geographically distributed energy assets in real time. The demonstration integrates 25 physical and digital assets, spanning wind, photovoltaics, batteries, electrolyzers, DC fast chargers, microgrid controllers, building automation systems, small modular reactors, control centers, and gas turbines, across five U.S. Department of Energy (DOE) national laboratories: National Laboratory of the Rockies (NLR), Idaho National Laboratory, National Energy Technology Laboratory, Lawrence Berkeley National Laboratory, and Sandia National Laboratories. These assets are unified using Energy Sciences Network (ESnet), a low-latency, high-performance DOE network, and are controlled via a centralized energy controller hosted at NLR's Advanced Research on Integrated Energy Systems facility. The demonstration validates the ability to stress-test hybrid energy systems under dynamic scenarios to de-risk advanced control strategies for greater resilience and flexibility.

24 POWER TRANSMISSION AND DISTRIBUTION↗

National Renewable Energy Laboratory, South Table Mountain Campus, Golden, Colorado

The National Renewable Energy Laboratory (NREL) South Table Mountain campus, located in Golden, Colorado, has multiyear datasets from buildings with approximately 1,100,000 sq ft of floor area. These 16 buildings include a large office, nine laboratories, and other education or public assembly facilities such as an education center, a warehouse, quick service restaurants, two site entrance security buildings, and a parking garage—all constructed and improved from 1982 to 2014. These datasets are also available from the NREL data storage and management platform SkySparks. The datasets contain electricity meter data (poser, voltage, and current) with 1-minute resolution and building automation system (BAS) data with resolutions of 5 or 15 minutes. Some subsystems (e.g., lighting) or equipment electricity data have the same intervals as above. Some mechanical equipment state or condition data, such as flow and temperature, are captured with 5- to 15-minute intervals. The types of measurement points (i.e., electrical meter power and zone temperature) and associated data quality across the campus are typical, which helps reduce the unreliability of data quality.

STM, Systems and equipment operational, Energy use↗

SuperLab 2.0 Showcase: Connecting Five Labs to Tackle Grid Complexity and Unlock Unique Grid Asset Potential

SuperLab 2.0 (5-Lab Demo) is a collaborative, national-scale experiment showcasing the coordination of geographically distributed energy assets in real time. The demonstration integrates 25 physical and digital assets, spanning wind, PV, batteries, electrolyzers, DC fast chargers, microgrid controllers, building automation systems, small modular reactor (SMR), control centers, and gas turbines, across five DOE national laboratories-NLR, INL, NETL, LBNL, and SNL. These assets are unified using Energy Sciences Network (ESnet), a low-latency, high-performance U.S. Department of Energy's (DOE) network, and controlled via a centralized energy controller hosted at NLR's ARIES facility. The demonstration validates the ability to stress-test hybrid energy systems under dynamic scenarios to de-risk advanced control strategies for greater resilience and flexibility. SuperLab 2.0 (5-Lab Demo) showcased a major advancement in federated national laboratory collaboration, enabling real-time, cross-laboratory experimentation to coordinate geographically dispersed distributed energy resources (DERs) using various communication protocols and networks. SuperLab 2.0 (5-Lab Demo) built on previous demonstrations conducted between NLR-PNNL and NLR-INL connecting diverse assets including distant protection devices, a SMR simulator, and a high temperature electrolyzer (HTE). Previous demos were based on a single connection between two labs with minimal coordination challenges. The 5-Lab demo with a centralized controller, distributed testbeds across different geographical locations, and use of protocols-based communication represents a scenario closer to real-world grid operations that coordinate resources across a region to meet system needs. This experiment studied how local DER controllers interact with a centralized energy controller during normal and abnormal events to maintain reliability. The SuperLab team across the five labs implemented a notional power system model equivalent of transmission and distribution lines, represented by the data networks interconnecting the labs. Each lab continuously exchanged local parameters (such as P and Q) from its Hardware-In-Loop (CHIL) and Power Hardware-In-Loop (PHIL) assets through centralized energy controller at NLR, enabling real-time interaction and coordination across sites. By leveraging ESnet as the communication backbone, the team successfully operated the distributed assets as a unified power system, with each bus represented by a different laboratory. This setup mirrors how assets interact in real-world power systems across dispersed locations with various protocols and latencies. At each lab site, assets were operated using their own local controllers which were coordinated through an overarching operation and control layer of centralized energy controller, equivalent to how an energy management system (EMS) orchestrates assets across a regional or national grid. SuperLab's federated connectivity utilized a Digital Real-Time Simulators (DRTS)-type gateway to connect Controller Hardware-In-Loop (CHIL) and PHIL assets between labs. To enable this federated connection through ESnet, a deterministic network was established where latency variations were consistent. This consistency allowed the development of digital filters for the power system assets across CHIL and PHIL interfaces to avoid unstable and unreliable grid conditions. This report provides an overview of the cross-laboratory configuration and offers insights into interconnecting geographically distributed research assets to test them as if they were co-located. This experiment represents a step toward linking nine DOE national laboratories, enabling nation-wide simulations that can address utility-driven challenges with grid resilience, flexibility, and modernization.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Robotics for HVAC applications: A critical review and future perspectives

Recent advances in artificial intelligence (AI), enhanced computational capabilities, and innovations in sensors and hardware have driven the increasing development and application of robots in heating, ventilation, and air conditioning (HVAC) systems. We selected and reviewed 101 studies published between 2005 and 2025, sourced from IEEE Xplore, Scopus, Web of Science, and the ACM Digital Library. To analyze these works, we developed a five-dimensional analytical framework (morphology, sensing, navigation, task execution, and system integration), inspired by the Springer Handbook of Robotics and tailored specifically for robotic applications in HVAC. Based on the reviewed studies, six distinct tasks spanning the entire HVAC lifecycle have been identified. Among the six tasks, inspection and maintenance dominate (59 %), followed by indoor monitoring and auditing (21 %), whereas leakage detection, comfort support, and installation/retrofit remain less explored. To address the identified gaps, this review proposes future research directions including investigating robot-aware HVAC design principles, developing multimodal HVAC sensing and data fusion techniques, enhancing robot training and hardware capabilities, and expanding robotic applications beyond Maintenance and Operations (M&O). The findings from this review inform future robotics research for HVAC applications and ultimately enhance system affordability, energy efficiency, resilience or reliability, and occupant environmental comfort. Moreover, it seeks to inspire researchers to explore the intersections of robotics, computer science, building science, and HVAC engineering fostering advancements in this multidisciplinary field.

AI↗

Building Operation Model (Morpheus) for Dallas Fort Worth Airport (CRADA CRD-19-16301 Final Report)

The primary objective of this project was to leverage digital twin technology to enhance the design and operation of DFW Airport terminals and their associated energy systems. To achieve this, Morpheus, a building digital twin, was developed to guide improvements in airport operations, specifically targeting reductions in peak power demand and overall energy consumption.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Platform for Remote Deployment and Training for Enhanced Building Operation Practices (Building Re-Tuning and On-going Commissioning)

While a building’s energy usage is driven largely by its design and use, building operator behavior has a strong influence on its energy consumption. This project developed and piloted a specific, data-driven coaching methodology to help operators understand how they can adjust operations and/or affect no/low-cost repairs or upgrades to their specific building HVAC systems to reduce energy consumption. Named BuildingCoach, the operational optimization method used is based on the Building Re-tuning approach developed by the Pacific Northwest National Laboratory. A building operations analytics market has matured over the past decade, though its potential to affect energy-saving changes has not been fully realized. Training operators to understand the methods for operational optimization with the explicit approach of using building-system performance data is hypothesized to create a more effective, longer lasting result in building energy efficiency, and this strategy is the fundamental premise of this project. With the support of an Industry Advisory Board, the project succeeded in developing materials and recruiting for and delivering three pilot cohorts. Deliverables included twenty-two self-paced training modules (accessed via a Learning Management System) and a web-based platform that includes access to real-time building system data and a repository for building system documentation. The project set out to have 100 participants from 50 buildings in three pilot cohorts. In the end, there were 28 participants from 17 buildings, i.e., a significant shortfall. The first two pilot cohorts had only two buildings in each, and this was partially due to difficulties in deploying the Building Operator Coaching Solution (“the BOCS”), which is technology that extracts the data from the controls network and presents it as prescribed for coaching. In the third cohort, the project team deployed the BOCS successfully to 13 buildings, the methodology was piloted as intended, and numerous opportunities for optimization were identified. The BuildingCoach business plan charts a path to an economically sustainable effort. However, even with a licensing model captured in the final version of the business plan, the scalability is still limited to keeping less than 1,000 buildings affected by 2033. Even so, there are unexplored paths to greater scalability that are being considered. CUNY BPL is working to perpetuate and grow the use of BuildingCoach. As of this writing, about twenty buildings have either been connected or will be connected with operators coached / to be coached in the NYC municipal portfolio, twelve buildings across four campuses in NY State will use BuildingCoach, a NY upstate county wishes for six or seven buildings to participate with the support of funding from NYSERDA, and others have also expressed interest. In the decades to come, there will be an increasing percentage of large and mid-sized buildings that incorporate automated system optimization (ASO), and the building operators’ role will shift to spend more time on maintenance and monitoring. Meanwhile, programs such as BuildingCoach will play a critical role in optimizing operations. And, regardless of the emergence of ASO, operators will still need to understand how their systems operate so that they can monitor them properly. Within that context, BuildingCoach is an important step towards operators’ understanding of efficient building system operations.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Integrated Controls Package for High Performance Interior Retrofit [Slides]

For the last few years, networked lighting control (NLCs) have promised significant energy savings beyond what is achieved through a basic light-emitting diode (LED) lighting retrofit. At the same time, NLCs can substantially increase the cost and complexity of the lighting retrofit. And as lighting system wattage declines because of the increasing efficiency of LEDs, advanced controls have less lighting energy to save and the cost-effectiveness of the NLC investment decreases. But NLCs can be leveraged to achieve significant energy savings and value by enhancing control of other building systems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Innovating the next generation of commercial smart building software

Nearly 30% of commercial building energy use is wasted due to equipment faults and HVAC controls problems. The result is increased emissions, compromised comfort and productivity, and less reliable coordination of building power needs with a clean grid. The energy impact alone represents $17 billion in potential savings. Today’s smart building software provides a robust solution to address these operational deficiencies. Energy management and information systems (EMIS) are saving up to 9% on average, with two-year paybacks. They are being incorporated into energy management processes, commissioning services, and utility programs. As effective as they are, two barriers prevent even deeper benefits; limited personnel to fix problems once they are identified, and the expense and time to manually implement changes in control systems. In partnership with the research community, the EMIS industry is developing new capabilities to overcome these barriers. Moving beyond siloed products for either fault detection and diagnostics, or optimal control, these new capabilities empower users to not only automatically identify faults, but also to push corrective action, and control improvements to their buildings. In this paper, several areas for enhancements are documented: ‘one-time’ correction of faults such as setpoints, schedules, and economizer lockouts; short-term active testing for automated proportional integral derivative (PID) loop tuning and functional testing; and continuous supervisory control for demand flexibility and year-round efficiency. Results are presented from a pair of partner implementations out of a dozen providers integrating these enhancements into their products, including field tests from across the country, and insights into operator acceptance and integration into operations and maintenance practices.

Casillas, Armando↗

NASA Tech Briefs, February 2007

Topics covered include: Calibration Test Set for a Phase-Comparison Digital Tracker; Wireless Acoustic Measurement System; Spiral Orbit Tribometer; Arrays of Miniature Microphones for Aeroacoustic Testing; Predicting Rocket or Jet Noise in Real Time; Computational Workbench for Multibody Dynamics; High-Power, High-Efficiency Ka-Band Space Traveling-Wave Tube; Gratings and Random Reflectors for Near-Infrared PIN Diodes; Optically Transparent Split-Ring Antennas for 1 to 10 GHz; Ice-Penetrating Robot for Scientific Exploration; Power-Amplifier Module for 145 to 165 GHz; Aerial Videography From Locally Launched Rockets; SiC Multi-Chip Power Modules as Power-System Building Blocks; Automated Design of Restraint Layer of an Inflatable Vessel; TMS for Instantiating a Knowledge Base With Incomplete Data; Simulating Flights of Future Launch Vehicles and Spacecraft; Control Code for Bearingless Switched- Reluctance Motor; Machine Aided Indexing and the NASA Thesaurus; Arbitrating Control of Control and Display Units; Web-Based Software for Managing Research; Driver Code for Adaptive Optics; Ceramic Paste for Patching High-Temperature Insulation; Fabrication of Polyimide-Matrix/Carbon and Boron-Fiber Tape; Protective Skins for Aerogel Monoliths; Code Assesses Risks Posed by Meteoroids and Orbital Debris; Asymmetric Bulkheads for Cylindrical Pressure Vessels; Self-Regulating Water-Separator System for Fuel Cells; Self-Advancing Step-Tap Drills; Array of Bolometers for Submillimeter- Wavelength Operation; Delta-Doped CCDs as Detector Arrays in Mass Spectrometers; Arrays of Bundles of Carbon Nanotubes as Field Emitters; Staggering Inflation To Stabilize Attitude of a Solar Sail; and Bare Conductive Tether for Decelerating a Spacecraft.

Source record↗

Using occupant interaction with advanced lighting systems to understand opportunities for energy optimization: Control data from a hospital NICU

For this study, lighting system control data from five patient rooms in a neonatal intensive care unit (NICU) over a 25-week monitoring period were analyzed to better understand how the NICU staff and families interacted with an automatic tunable lighting system (variable spectrum and intensity) with manual override options. The data were analyzed to determine the amount of time spent in available lighting modes, estimate energy consumption, and to observe any patterns in how the lighting system was being used by occupants. Further analysis revealed opportunities for optimizing the system for occupant needs and energy savings. The patient room occupants were clearly engaged in using the lighting system throughout the 24-hour day to meet needs and preferences. Giving occupants control over the lighting system did not result in a considerable increase in energy use. Implementing a time-out would minimize the extended periods of time when the lights were left on without need at the highest brightness level, further decreasing energy use. This analysis reveals the potential of lighting control data to contribute to energy savings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Model predictive control for integrated control of air-conditioning and mechanical ventilation, lighting and shading systems

Modern buildings are increasingly automated and often equipped with multiple building services (e.g., air-conditioning and mechanical ventilation (ACMV), dynamic shading, dimmable lighting). These systems are conventionally controlled individually without considering their interactions, affecting the building’s overall energy inefficiency and occupant comfort. A model predictive control (MPC) system that features a multi-objective MPC scheme to enable coordinated control of multiple building services for overall optimized energy efficiency, indoor thermal and visual comfort, as well as a hybrid model for predicting indoor visual comfort and lighting power is proposed. The MPC system was implemented in a test facility having two identical, side-by-side experimental cells to facilitate comparison with a building management system (BMS) employing conventional reactive feedback control. The MPC system coordinated the control of the ACMV, dynamic façade and automated dimmable lighting systems in one cell while the BMS controlled the building services in the other cell in a conventional manner. The MPC side achieved 15.1–20.7% electricity consumption reduction, as compared to the BMS side. Simultaneously, the MPC system improved indoor thermal comfort by maintaining the room within the comfortable range (-0.5 < predicted mean vote < 0.5) for 98.3% of the time, up from 91.8% of the time on the BMS side. Visual comfort, measured by indoor daylight glare probability (DGP) and horizontal illuminance level at work plane height, was maintained for the entire test period on the MPC side, improving from having visual comfort for 94.5% and 85.7% of the time, respectively, on the BMS side.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Visual Brick model authoring tool for building metadata standardization

In this study, the Brick ontology is a unified semantic metadata standard for building assets and their relationships, serving as a key enabler for effective interoperability and automation of building systems and analytics. However, creating a Brick model, in other words, standard semantic metadata based on the Brick ontology for a building dataset, can be a complex task. This paper presents two case studies of the creation of Brick models for real-world residential and commercial building datasets, highlighting the challenges during the Brick model creation process. Additionally, the paper introduces VizBrick, an interactive authoring tool for creating semantic building metadata. VizBrick facilitates the creation of Brick models by providing an intuitive visual interface and interactive capabilities, such as keyword search, automatic mapping suggestions, and recommendations. The use of VizBrick is shown to significantly reduce the time and effort required during the Brick model creation process.

42 ENGINEERING↗

Performance Demonstration of an Occupancy Sensor-enabled Integrated Solution for Commercial Buildings

Traditionally, a single-loop fixed-gain controller is applied to supply fan (SF) and cooling coil (CC) valve controls while a fixed-damper position control is applied to outdoor air (OA) damper control at air handling units (AHUs) in commercial buildings. With the increasing application of occupancy sensors, the information generated by occupancy sensors is applied to not only reduce the electricity loads from lighting and controllable plug loads, but also reset OA intake and minimum supply airflow setpoints. Meanwhile, these intermittent operation actions greatly elevate the dynamics of AHU systems, which may introduce unstable SF and CC valve operations and inaccurate OA flow control at AHUs and consequently degrade maximum energy efficiency gains. With virtual fan and valve flow meter technologies, two advanced controls, including cascade control and gain scheduling control, can be implemented on both the SF and CC valve, and an advanced control using a virtual OA flow meter can be implemented on OA damper integrated with occupancy sensors. The goal of this project is to demonstrate the savings, cost, and performance of an integrated solution that integrates the three advanced HVAC controls with occupancy sensors to allow accurate and stable AHU operations in real buildings. The project objectives are to: 1) develop and validate an advance SF control algorithm; 2) develop and validate an advanced CC valve control algorithm; 3) validate an algorithm to implement a virtual OA flow meter; and 4) demonstrate the savings, cost, and performance of the integrated solution in real buildings. The technical approaches are to: 1) select a test system at the University of Oklahoma; 2) develop and implement the algorithms of advanced SF and CC valve controls and validate the performance; 3) develop and implement the advanced OA control using a virtual OA flow meter and validate the performance; 4) demonstrate the savings, cost, and performance of the proposed integrated solution with and without three advanced HVAC controls; and 5) disseminate the project results through publications and presentations. For the SF control, both the gain scheduling and cascade controls can improve the fan energy performance by reducing the fan power during the transient period and the fan control performance at lower speeds by reducing fan speed variation. Moreover, the gain scheduling control provides a simple and low-cost solution and is recommended. The fan power savings can reach 30% in a transient period. For the CC valve control, the gain scheduling control can considerably reduce the supply air temperature oscillation range and frequency under both higher and lower load conditions and the control valve response is much more stable. As a result, the gain scheduling control is recommended. The projected pump energy consumption can be reduced by 68.5%. With the developed virtual OA flow meter, the OA can be accurately controlled at its setpoint, which is determined based on the actual number of occupants in the building provided by occupancy sensors. The RMSE of the proposed OA control is 15.9 L/s. The energy data shows that the fan power and CC cooling energy were significantly reduced. On the other hand, the energy savings majorly results from the occupancy sensors and the energy savings by the advanced HVAC controls is minimal because that the controllers in the test AHU were tuned with very slow response. An annual technical savings potential is estimated as 0.5 quads in the commercial sector.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗