Search NASA⌕ Search

SEARCH · Search NASA

Results for “Building codes”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

A Survey of Direct Heating Equipment Market Actors in California

Direct Heating Equipment (DHE) is a category of ductless space heating appliances that provide warm air directly to the space where they are installed. We investigate, from the perspective of the DHE supply chain in California, what types of DHE are marketed in the state, how they are sold and serviced, and whether any potential barriers to adoption of high-efficiency DHE exist. We find that the market for DHE in the state is almost exclusively a replacement market, with some additional repair and maintenance services. We also find that, even though manufacturers sell high-efficiency DHE models in California, most contractors report installing baseline models most of the time. Contractors say their customers do not see any value in high-efficiency units, and they (contractors) do not believe that high-efficiency DHE is worth the additional cost to their customers. In addition, the majority of contractors purchase DHE from distributors and, therefore, distributors are a key piece of the supply chain that can constrain DHE purchase choice. Distributors do not see a demand for high-efficiency DHE and, hence, do not keep stock of these units. They argue that, since the market is driven mostly by replacements and these replacements occur typically in an unplanned way, homeowners are unwilling to pay for any additional costs associated with a high-efficiency model. Rather, homeowners usually prefer to replace the failed unit with a new unit that can fit in the same location with no- or minimal additional replacement costs. Considering that most DHE purchases are made by contractors, on behalf of their customers, informing contractors (and homeowners) of the potential cost-effectiveness of efficient DHE could help mitigate some of the barriers to the adoption of high-efficiency DHE in the state. In addition, monetary incentives and more stringent building codes that apply to DHE replacements can contribute to increasing adoption of high-efficiency DHE in California. This will not only reduce energy costs, but also increase safety and comfort to DHE users.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Evaluation of Low Environmental Impact Distributed Scroll Booster Technology for Supermarket Refrigeration

A distributed scroll booster refrigeration system is proposed as an alternative for current refrigeration systems used in supermarket applications. The distributed scroll booster system is configured to enable the use of low-pressure refrigerants such as R-1234yf, which has a global warming potential (GWP) of less than 1, in a cycle configuration that employs a two-stage compression process. This scroll booster system is comprised of medium-temperature compressors (high stage) coupled with low-temperature compressors (low stage). This two-stage system architecture allows both low-temperature and medium-temperature refrigerated display cases to be integrated in the same system. By design, this system reduces the refrigerant charge, produces higher efficiencies (two-stage compression), uses existing components minimizing cost impact, and will be able to use ultra-low GWP class A2L (low toxicity and low flammability) refrigerants such as R-1234yf when standards and building codes are updated (expected by 2025).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

DASSH-F: Subchannel Based Thermal Analysis

The DASSH thermal analysis code is designed to rapidly allow a reactor design engineer to obtain flow rates requirements that satisfy peak temperature constraints in the domain. The advantage of using DASSH over a hand calculation is that it has a more rigorous treatment of the pin power distribution and coolant heat transfer within an assembly and between assemblies. The advantage of using DASSH over a conventional 3D subchannel code or a computational fluid dynamics code (CFD) is that it can obtain the desired solution in a matter of minutes in serial with minor computer memory needs. The DASSH methodology is virtually identical to SUPERENERGY-2 with additional functionalities taken from follow on work to SUPERENERGY-2 done at ANL in the 1980s. DASSH today is an integral component of the Argonne Fast Reactor analysis suite for reactor design work. DASSH obtains the power distribution from a coupled neutron-gamma heating calculation in GAMSOR (including DIF3D) at each time point of a companion fuel cycle analysis calculation with REBUS. The domain in DASSH assumes a hexagonal grid typical for fast reactors with much of the geometry information taken from the DIF3D model. DASSH assumes the assemblies that are loaded into each grid position are ducted to control the coolant flow. Considerable detail is given on the subchannel formulation of DASSH in this document. Much of the formulation and design of the code builds upon research done by previous authors with little new investigation. Thus the decisions made in developing the subchannel model used in DASSH have their origins over 50 years ago. Much of the heat transfer methodology in DASSH is built upon correlations for both the coolant mixing and heat transfer coefficients for pins and ducts. DASSH is thus not a rigorous treatment of a given problem, but a rapid assessment of the temperature field that has known limitations with respect to an experimental measurement or CFD calculation. The DASSH input and output are detailed along with usage of the software. The DASSH output provides tables of evaluated material properties and key coolant and pin temperature results. DASSH can create Python scripts that generate domain summary pictures. DASSH can also generate assembly temperature maps and VTK output files which allow the DASSH solution to be visualized. As the primary purpose of the DASSH software is to compute the coolant and fuel pin temperature distribution for a given model of a reactor, much of the output focus is giving the user quick summary tables needed to assess the performance of a given orifice flow specification. The present version of DASSH has a crude orifice search capability and an efficient orifice flow search capability. The flow search tries to meet user specified constraints for 1) peak 2-sigma clad midwall temperature, 2) peak coolant temperature, and 3) desired bulk outlet temperature. There are many development shortcomings in DASSH detailed in this document, but this version is functional for modern analysis needs. This document serves as the manual for the Fortran based DASSH software that was developed to replace the Python version of DASSH developed as part of the VTR program.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Development of a Two-Dimensional CASTLE Transmission-Line Model for all Levels of Saturn

This report describes a two-dimensional model of Saturn based on the CASTLE transmission line code. Building on previous modeling efforts, 2D circuit models based on the “chain-link fence” geometry are constructed for pre-ReCap Saturn and post-ReCap Saturn. The 2D model results are in better agreement with data from Shot 4550 measurements of load currents and doses then the previous 1D model. Lower doses (9%) predicted by the new model can be compensated by increasing the load A-K gap.

43 PARTICLE ACCELERATORS↗

Probabilistic Seismic Hazard Analysis for Iraq Based on the Updated Earthquake Catalog (1900-2021) and Ground Motion Characteristics

Onur et al. (2017) compiled the first comprehensive earthquake catalog for Iraq, covering 1900 to 2009 within 26°–40°N latitude and 36°–51°E longitude. This catalog was utilized in a probabilistic seismic hazard assessment (PSHA) by Abdulnaby et al. (2020) to aid in updating Iraq’s building code seismic provisions. Recently, we have updated the earthquake catalog for Iraq by adding earthquakes recorded from 2010 to 2021 and directly calculating moment magnitude (Mw) for about 2,800 earthquakes using the coda envelope methodology and waveform data from the Mesopotamian Seismological Network (MPSN) in Iraq.

58 GEOSCIENCES↗

DASSH-F: Subchannel Based Thermal Analysis

The DASSH thermal analysis code is designed to rapidly allow a reactor design engineer to obtain flow rates requirements that satisfy peak temperature constraints in the domain. The advantage of using DASSH over a hand calculation is that it has a more rigorous treatment of the pin power distribution and coolant heat transfer within an assembly and between assemblies. The advantage of using DASSH over a conventional 3D subchannel code or a computational fluid dynamics code (CFD) is that it can obtain the desired solution in a matter of minutes in serial with minor computer memory needs. The DASSH methodology for pin lattice models is virtually identical to SUPERENERGY-2 with additional functionalities taken from follow on work to SUPERENERGY-2 done at ANL in the 1980s. DASSH today is an integral component of the Argonne Fast Reactor analysis suite for reactor design work. DASSH obtains the power distribution from a coupled neutron-gamma heating calculation in GAMSOR (including DIF3D) at each time point of a companion fuel cycle analysis calculation with REBUS. The domain in DASSH assumes a hexagonal grid typical for fast reactors with much of the geometry information taken from the DIF3D model. DASSH assumes the assemblies that are loaded into each grid position are ducted to control the coolant flow. The user can alternatively provide their own geometry and power profile instead of inheriting it from DIF3D. Considerable detail is given on the subchannel formulation of DASSH in this document. Much of the formulation and design of the code builds upon research done by previous authors with little new investigation. Thus the decisions made in developing the subchannel model used in DASSH have their origins over 50 years ago. Much of the heat transfer methodology in DASSH is built upon correlations for both the coolant mixing and heat transfer coefficients for pins and ducts. DASSH is thus not a rigorous treatment of a given problem, but a rapid assessment of the temperature field that has known limitations with respect to an experimental measurement or CFD calculation. The DASSH input and output are detailed along with usage of the software. The DASSH output provides tables of evaluated material properties and key coolant and pin temperature results. DASSH can create Python scripts that generate domain summary pictures. DASSH can also generate assembly temperature maps and VTK output files which allow the DASSH solution to be visualized. As the primary purpose of the DASSH software is to compute the coolant and fuel pin temperature distribution for a given model of a reactor, much of the output focus is giving the user quick summary tables needed to assess the performance of a given orifice flow specification. The present version of DASSH has a crude orifice search capability and a sufficient orifice flow search capability. The flow search tries to meet user specified constraints for 1) peak 2-sigma clad temperature, 2) peak coolant temperature, and 3) desired bulk outlet temperature. This document serves as the manual for the Fortran based DASSH software that was developed to replace the Python version of DASSH developed as part of the VTR program.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Making Data-Driven Policy Decisions for the Nation’s First Building Energy Performance Standards

Nearly every major U.S. city has committed itself to ambitious climate action goals – for Washington, DC this means a 50 percent reduction in greenhouse gases by 2032 and carbon neutrality by 2050. In support of these goals, Washington, DC has passed one of the most aggressive and practical climate action bills in the nation—with the Clean Energy DC Omnibus Act, DC became the first city in the U.S. to adopt energy performance standards for existing buildings. DC’s Building Energy Performance Standards (BEPS) require energy efficiency improvements for all commercial and multifamily buildings that do not meet a sector-specific minimum ENERGY STAR score or equivalent metric, with iterative compliance cycles every five years that will accelerate the pace of whole building retrofits. This paper explores this revolutionary policy framework and uses two data analysis projects that DC conducted to evaluate the potential impact of the BEPS and move towards carbon neutrality. First, we analyze the potential energy savings and greenhouse gas reductions, as well as potential cost impacts, from the implementation of a BEPS policy in DC We then examine the role of BEPS in a carbon neutrality strategy, how BEPS savings iterate over time, and what additional existing building improvements will be driven by the gravitational pull of new building codes on median performance. The paper highlights the benefits and limitations of such data-driven approaches to support policy decisions. Finally, we will review ongoing BEPS implementation, including expected policy directions, critical supportive programs, and lessons learned to date.

Bergfeld, Katie↗

Characterization of Mechanical Ventilation Systems in New US Homes: What types of systems are out there and are they functioning as intended?

As the airtightness of homes improves to meet energy efficiency goals, it becomes more important for mechanical ventilation systems to help maintain a comfortable and healthy indoor air environment. ASHRAE Standard 62.2 provides national guidance for mechanical ventilation system design and installation, however adoption of those guidelines into local building codes has occurred at different rates. Once provisions for mechanical ventilation are adopted in a local code, are mechanical ventilation systems properly designed, installed, commissioned and operated according to code or above code program requirements? Is there a need for further industry and homeowner education to ensure systems function as intended? This paper presents results from field studies that include characterization of mechanical ventilation systems in over 150 new homes in CA, CO, FL, GA, IL, OR, and SC built between 2011 and 2018. In each of the study homes, airflow of local (kitchen, bathrooms) and whole-house ventilation were measured. Occupant usage of the mechanical ventilation systems were monitored for one week in each home. Installed performance is compared to inferred design intent. The paper also includes homeowner perceptions about, and interactions with, the installed mechanical ventilation systems.

Martin, Eric↗

Warm Unit Stand Analysis for Proton Improvement Project II

The Proton Improvement Project II, commonly referred to as PIP II, is a linear accelerator overhaul at Fermilab to eventually double the output of its existing proton beam to continue to be the leading force in high energy physics. The proton beam is created through a series of high frequency cryomodules that must be connected utilizing a combination of magnets and vacuum pumps to ensure the beam is properly aligned. A housing mechanism for the magnets and vacuum pumps (Warm Units) will be placed between the cryomodules for realignment and require multiple stages of 6 degree-of-freedom adjustment options, to ensure that the beam alignment can fit all realistic requirements. Extensive testing and design modifications on the Warm Unit stand was completed to confirm not only the strength of the unit in nominal configuration, but also at each possible adjustment orientation for each 6 degree-of-freedom option. Structural analysis was also completed for various unique loading conditions i ncluding transportation loading and confirming the unit satisfies international building code. Simultaneously, testing and design modifications were done to confirm that the frequency modes of the system resided outside of concern ranges, which is determined by Fermilab safety codes and is set to exceed 15 Hz. Design changes that simultaneously stiffen the system to raise the lowest frequency modes while expanding access for technicians and allow for easier fabrication were developed and implemented into the Warm Unit stand. Various relationships between the design changes and the overall vibrational patterns were also developed for future use and study as the rest of PIP II matures.

43 PARTICLE ACCELERATORS↗

Interactive Rotated Object Detection for Novel Class Detection in Remotely Sensed Imagery

In this paper we propose IRTR-DETR an Interactive and Real-Time Rotated DEtection TRansformer that extends IRTDETR to predict rotated bounding boxes. IRTR-DETR maintains the Human-In-The-Loop (HIL) workflow of IRTDETR but introduces rotation-aware heads for improved detection of objects with arbitrary orientations. Similarly to IRTDETR IRTR-DETR can be trained with a small labeled sample set in an interactive setting but we show that it can also be pretrained on related but not identical data--such as a building damage dataset--before being applied to tasks like identifying buildings under construction. We demonstrate the efficacy of our approach on the publicly available Tiny-DOTA and xBD dataset as well as two study-cases on proprietary datasets of greenhouses and houses under construction ("waffle homes"). Detecting greenhouses is highly relevant in the context of damage assessment while "waffle homes" aid understanding typical floorplans and building codes in different areas both thereby supporting population modeling emergency response and policy planning. Our method outperforms the state of the art in interactive rotated object detection on the Tiny-DOTA dataset by 5.7 percent and improves upon the non interactive RTDETR by 7.85 to 19.39 percent (depending on the number of provided samples) while maintaining its real-time efficiency.

Burges, Marvin [ORNL] (ORCID:0000000312690769)↗

Data Analysis of Energy Code Compliance in Commercial Buildings

What percent of newly constructed commercial buildings comply with the energy code? How much energy and cost could be saved if the compliance increased? Which code requirements have both low compliance rates and high savings potential? These are the questions U.S. Department of Energy (DOE) is trying to answer through its Commercial Energy Code Field Study. Previous commercial studies have been very limited and did not result in a widely accepted and tested methodology. DOE’s goal is to create a standardized methodology that can produce actionable results at a reasonable study cost, that can be used by state and local governments and utilities and provides valuable information to policy makers. The field study team implemented the pilot methodology, compiling a data set of 230 office and retail buildings in two climate zones. The approach is based on identifying lost savings on a total energy cost basis rather than simply counting the quantity of measures that do not meet code. This report is focused on the analysis of the collected data. The primary goal was to analyze the data collected during the field study and determine the actual energy cost impact of each measure in a non-compliance situation. The energy impact results allowed for ranking the measures to identify which have the highest potential for lost savings. These results combined with the time required to verify each measure will allow future compliance verification to focus on measures that had a large impact on energy use over the life of the building and those that have the greatest savings recovery potential per verification hour.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Data Analysis of Energy Code Compliance in Commercial Buildings (Rev. 1)

What percent of newly constructed commercial buildings comply with the energy code? How much energy and cost could be saved if the compliance increased? Which code requirements have both low compliance rates and high savings potential? These are the questions U.S. Department of Energy (DOE) is trying to answer through its Commercial Energy Code Field Study. Previous commercial studies have been very limited and did not result in a widely accepted and tested methodology. DOE’s goal is to create a standardized methodology that can produce actionable results at a reasonable study cost, that can be used by state and local governments and utilities and provides valuable information to policy makers. The field study team implemented the pilot methodology, compiling a data set of 230 office and retail buildings in two climate zones. The approach is based on identifying lost savings on a total energy cost basis rather than simply counting the quantity of measures that do not meet code. This report is focused on the analysis of the collected data. The primary goal was to analyze the data collected during the field study and determine the actual energy cost impact of each measure in a non-compliance situation. The energy impact results allowed for ranking the measures to identify which have the highest potential for lost savings. These results combined with the time required to verify each measure will allow future compliance verification to focus on measures that had a large impact on energy use over the life of the building and those that have the greatest savings recovery potential per verification hour.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Pathways to Carbon Neutrality 2050 in Malaysia and Kuala Lumpur

Malaysia has recently set an ambitious target of achieving carbon neutrality as early as 2050. To accomplish this, the country will need to strategically reduce its emissions across all sectors. In 2020, Malaysia emitted approximately 368 MtCO2e, with the largest sources of emissions including electricity (36% of total emissions), transportation (17%), and industry (15%)1. We find that the greatest reductions in emissions can therefore come from decarbonizing power generation and electrifying end-use sectors. Digitalization, smart technologies, and improved energy efficiency will significantly reduce economy-wide energy consumption. By leveraging efficient technologies, both Malaysia and Kuala Lumpur can address the challenges posed by rapid urbanization and climate change. Digitalization is a broad category that includes a variety of measures; for example, the wide adoption of high-efficiency appliances and lighting or improved building energy codes in the buildings sector. Similarly, technological improvements can advance industrial energy efficiency, and for transportation, smart technologies cover a shift from private to public transportation and the greater use of electric vehicles. While renewable energy (RE) will play a crucial role in decarbonization, achieving carbon neutrality in certain sectors will be difficult without emerging technologies like carbon capture and storage (CCS) and innovative fuel sources such as hydrogen. In order for Malaysia to rely on CCS as a mitigation option, early investment and incentives to the private sector will be critical. This holds for the use of hydrogen as well: investing in the necessary technology, infrastructure, and human capital will allow Malaysia to position itself as an innovator in the region and leverage these advanced technologies as a key part of its climate strategy. Another possible carbon removal option other than CCS would be a land-use sink; however, given that Malaysia is still developing and may deforest in the near-term, this report does not focus on the mitigation potential of land-use change. With its innovative and bold climate plans, Kuala Lumpur is primed to be a leader in regional climate change efforts. Kuala Lumpur is also engaged in several international collaborations to ensure sustainable city development such as the C40 network and the ASEAN Smart Cities Partnership. As such, the city will play a critical role in contributing to Malaysia’s overall climate goals and as a policy trendsetter through ambitious, scalable plans. One key factor in these emissions reductions is that Kuala Lumpur has full control over its building guidelines, allowing for ambitious policies resulting in significant emissions reductions. However, in other sectors, Kuala Lumpur has less direct control over regulations; for example, power generation and integration of RE are largely in the hands of the Malaysian government. With limited and primarily light industry, Kuala Lumpur’s contributions to emissions reductions here are curbed. And, while Kuala Lumpur has control over local transportation policies like increasing access to and quality of public transportation, broad shifts in transportation will stem from national-level policies. As such, multi-level governance is an integral component of Malaysia’s climate strategy and coordination between local and national governments will be essential in reducing emissions and achieving other climate goals. This report addresses these and other key challenges and opportunities Malaysia faces on the road to carbon neutrality.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Prototype College Building Energy Model: Building Characteristics and Energy Simulation Results

The US Department of Energy supports the development of commercial building energy codes and standards. To support commercial building energy research activities and the development of commercial building energy codes and standards, continuous efforts have been made to convert 16 prototype building models, which cover 80% of US commercial building floor space, to OpenStudio prototype buildings. Additionally, the suite of prototype building models was expanded to include the addition of new building prototype models (e.g., courthouse, college building). Multiple sources, including databases, documented projects, and personal communications, were used to define the prototype college building, and a 4-story with 69,063 ft 2 building was considered as the prototype college building to represent an average-sized college building in the United States. To represent realistic occupancy schedules and increase the granularity of information, actual class reservation schedules were collected and used. This report documents the building and system characteristics of the prototype college building model combined with climate-specific and construction vintage–specific requirements for the building envelope and systems from ASHRAE Standard 90.1. The energy simulation results are presented for 4 construction vintages (2004, 2007, 2010, and 2013) and 15 ASHRAE climate zones. The site energy use intensity of the college building was compared with 2012 Commercial Building Energy Consumption Survey (CBECS) and ENERGY STAR data to verify the simulation results. The site energy use intensity of the college building ranged from 60 to 202.4 kBtu/ft 2 , and compared with the energy use intensities of Commercial Building Energy Consumption Survey (122.9 kBtu/ft 2 ) and ENERGY STAR (84.3 kBtu/ft 2 ) data, the prototype college building results are in a reasonable range.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Defining the Prototype Convenience Store Building Characteristics

The US Department of Energy supports the development of commercial building energy codes and standards. To support commercial building energy research activities and the development of commercial building energy codes and standards, continuous efforts have been made to convert 30 prototype building models (20 different building types), which cover 80% of US commercial building floor space, to OpenStudio prototype buildings. Additionally, the suite of prototype building models was expanded to include the addition of new building prototype models (e.g., courthouse, college building). This report documents the building and system characteristics of the prototype convenience store building model. Multiple sources, including databases, documented projects, and personal communications, were used to define the prototype convenience store building characteristics, and a one-story, 3,000 ft 2 building was considered as the prototype convenience store to represent an average-sized convenience store in the United States. The Oak Ridge National Laboratory team defined the operational hours of the convenience store as 17 hours per day. The types of exterior walls, roof, and floor were defined as brick wall, metal surfacing roof, and slab-on-grade floor, respectively. Double glazing was selected, and the window-towall ratio was set as 15% on the front side. For the system part, packaged system and centralized water heater were selected for the space heating and cooling system and water heater system, respectively. In terms of the refrigerator system, the number of refrigerators and freezers were determined as eight closed cases and two walk-in units.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

All Hands On Deck: Raising the Bar on Whole Building Performance-Based Code Compliance and Above-Code Programs

In 2019 a large-scale national effort was launched with support from U.S. Department of Energy, Pacific Northwest National Laboratory and Northwest Energy Efficiency Alliance (NEEA). The project aimed to develop a long-term vision and a roadmap for achieving a practical application of whole building performance-based code and above code program compliance in commercial buildings. The work was aided by engaging over 70 stakeholders across the country representing jurisdictions, above-code programs such as LEED and ENERGY STAR Multifamily Program, members of the ASHRAE Standard 90.1 and other Standard committees, IBPSA and software developers. The performance path requires whole building energy modeling and is gaining momentum. Many see it as the future of the commercial energy codes and the main pathway for achieving zero energy buildings. The paper describes the findings from a stakeholder survey funded by NEEA on the current state of performance-based path, its market penetration, trends, implementation practices and adoption challenges. It discusses the patterns revealed by experience of the states with decades-long history of performance-based compliance such as Florida and California and opportunities for taking advantage of the synergies between code and above-code programs. In addition, the paper provides an overview of the tools and resources developed as part of the effort including the compliance form for ASHRAE Standard 90.1 Section 11 and Appendix G, modeling submittal review manual, and modeler and reviewer qualification requirements. The tools and resources would help remove market barriers, deliver immediate benefits to jurisdictions and rating authorities, and achieve energy efficiency through whole-building performance path.

TSPR, Performance Based Complinace, Washington Sta↗

Energy Efficiency Field Study: Influence of Key Measures in Home Rules States

The goal of the Energy Efficiency Field Study: Influence of Key Measures in Home Rule States project is to empower and support the states of Utah and Arizona in the successful implementation of their building energy codes. Employing the Department of Energy (DOE) Residential Building Energy Code Field Study Data Collection & Methodology, the research team evaluated real-world implementation status against a baseline, with a particular focus on the unique challenges presented by the dry, hot climates of Utah and Arizona.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

A new database of building-space-specific internal loads and load schedules for performance based code compliance modeling of commercial buildings

Building-level loads and load profiles prescribed by current modeling rules save modelers time and avoid gaming during whole building performance modeling. However, recent studies show that they sometimes insufficiently capture the entire building performance due to the varied loads and load profiles for different space types. As a solution to this issue, this paper develops a database of building-space-specific loads and load profiles used in code compliance modeling. The existing sets of loads and load profiles are reviewed and the challenges behind using them for specific research topics are discussed. Then, the proposed method to develop the building-space-specific loads and load profiles is introduced. After that, the database for these building-space-specific loads and load profiles is presented. In addition, one case is studied to demonstrate the applications of these loads and load profiles. In this case study, three methods are used to develop building energy models: space-specific (using knowledge of the distribution and location of space types and applying the space-specific data in the developed database), building-level (assuming a lack of knowledge of the space types and using the building-level data in the developed database), and calculated-ratio (assuming knowledge of the distribution of space types but not their locations and calculating weighted average values based on the space-specific data in the developed database). Finally, the energy results simulated by using these three methods are compared, which show building-level methods can produce energy results up to 20% different than the space-specific methods. Finally, this paper discusses the application scope and maintenance of this new database.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗