Analysis of mobility data to build contact networks for COVID-19

As social distancing policies and recommendations went into effect in response to COVID-19, people made rapid changes to the places they visit. These changes are clearly seen in mobility data, which records foot traffic using location trackers in cell phones. While mobility data is often used to extract the number of customers that visit a particular business or business type, it is the frequency and duration of concurrent occupancy at those sites that governs transmission. Understanding the way people interact at different locations can help target policies and inform contact tracing and prevention strategies. This paper outlines methods to extract interactions from mobility data and build networks that can be used in epidemiological models. Several measures of interaction are extracted: interactions between people, the cumulative interactions for a single person, and cumulative interactions that occur at particular businesses. Network metrics are computed to identify structural trends which show clear changes based on the timing of stay-at-home orders. Measures of interaction and structural trends in the resulting networks can be used to better understand potential spreading events, the percent of interactions that can be classified as close contacts, and the impact of policy choices to control transmission.

60 APPLIED LIFE SCIENCES↗

Effective Missing Value Imputation Methods for Building Monitoring Data

To understand behaviors of natural and man-made events, such as energy consumption of buildings, which accounts for 40% of energy uses in the US, we deploy automated monitoring devices to record periodic observations. However, such experimental and observation data often contains problems and irregularities that have to be cleaned up before analyses. Due to various conditions affecting sensor operations, the communication channels, recording steps, or the recording media, the recorded data might have missing values, errors, or anomalous values. An effective way to clean up these problems is to replace these missing values, errors and anomalous values with expected values, a process generally known as imputation. In this work, we survey commonly used missing value imputation techniques and compare their performance on a set of building monitoring data. To compare the different types of sensor measurements with widely varying characteristics, we use normalized root mean squared error (NRMSE) as the key metric for the effectiveness of the imputation methods. We additionally consider periodicity and run time when considering comparing methods. Through extensive testing, we find that for small gap sizes, up to 8 consecutive missing values, linear interpolation performs the best; for larger gaps stretching up to 48 consecutive missing values, K-nearest neighbors provides the most accurate imputations; for even larger gaps, more computational intensive methods, such as matrix factorization, achieve the smallest NRMSE. Additionally, we observe that these computationally intensive algorithms not only provide accurate imputations for large gaps, but are also more robust across all types of sensors.

Cho, B↗

Applying Energy Data Tools to Inform the Valuation of Commercial Buildings

This case study describes a suite of free tools from DOE and EPA ENERGY STAR® and how users have applied them to enhance the value of commercial office building data through various aspects of energy and building performance. The tools addressed are EPA’s ENERGY STAR Portfolio Manager, DOE’s Building Energy Asset Score, and DOE’s Building Performance Database.

energy data, commercial, office, data tools, comme↗

System and method for characterization of retrofit opportunities in building using data from communicating thermostats

Systems and methods for characterization of retrofit opportunities are described. The methods may comprise computing, using at least one computing device disposed remote from a building and based at least in part on heating, ventilation and air conditioning (HVAC) runtime data associated with the building, one or more thermal characteristics of the building. In some embodiments, a model-predicted indoor temperature may be fitted against thermal data measured by a thermostat at the building. The thermal characteristic of the building may comprise a thermal insulation, an air leakage rate and/or an HVAC efficiency. The method may be used to determine, using the at least one computing device, suitability of the building for a retrofit opportunity to improve energy efficiency of the building. Determining the suitability may comprise evaluating the one or more thermal characteristics. The HVAC runtime data may be computed based on data received from a thermostat or a meter, such as an electric or a gas meter.

Zeifman, Michael↗

System and method for characterization of retrofit opportunities in building using data from interval meters

Systems and methods for characterization of retrofit opportunities are described. The methods may comprise computing, using at least one computing device disposed remote from a building and based at least in part on heating, ventilation and air conditioning (HVAC) runtime data associated with the building, one or more thermal characteristics of the building. In some embodiments, a model-predicted indoor temperature may be fitted against thermal data measured by a thermostat at the building. The thermal characteristic of the building may comprise a thermal insulation, an air leakage rate and/or an HVAC efficiency. The method may be used to determine, using the at least one computing device, suitability of the building for a retrofit opportunity to improve energy efficiency of the building. Determining the suitability may comprise evaluating the one or more thermal characteristics. The HVAC runtime data may be computed based on data received from a thermostat or a meter, such as an electric or a gas meter.

Zeifman, Michael↗

System and method for characterization of air leakage in building using data from communicating thermostats and/or interval meters

Systems and methods for characterization of retrofit opportunities are described. Some embodiments are directed to methods for determining the air leakage rate of a building, and accordingly, for determining suitability of sealing of air leaks to improve the energy efficiency of a building. The methods may comprise computing, using at least one computing device disposed remote from a building and based at least in part on heating, ventilation and air conditioning (HVAC) runtime data associated with the building, one or more thermal characteristics of the building. The HVAC runtime data may be computed based on data received from a thermostat or a meter, such as an electric or a gas meter. To isolate the impact of air leakage, subsets of the HVAC runtime data at time intervals selected to have substantially the same conditions, but different wind speeds, may be computed.

Zeifman, Michael↗

Building Benchmark Data Platform

This project is a three-year, four-laboratory collaboration to collect and curate a handful of high-resolution building systems datasets that have broad applicability to address highest-impact use cases. We will collect and curate high-resolution, well-calibrated time series of building operational and indoor/outdoor environmental data, which are crucial to understanding and optimizing building energy efficiency performance and demand flexibility capabilities as well as benchmarking energy algorithms.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Evaluate the impact of sensor accuracy on model performance in data-driven building fault detection and diagnostics using Monte Carlo simulation

The performance of data-driven fault detection and diagnostics (FDD) is heavily dependent on sensors. However, sensor inaccuracy and sensor faults are pervasive in building operation: inaccurate and missing sensor readings deteriorate FDD performance; sensor inaccuracy will also affect the selection of sensor for data-driven FDD in the model training process, which is another key factor of data-driven FDD performance. Sensor accuracy and sensor selection individually are well-studied research topics in this field, but the impact of sensor accuracy on sensor selection and its further impact on FDD performance has not been evaluated and quantified. In this paper, we developed a novel analysis methodology that comprehensively evaluates sensor fault on sensor selection and FDD accuracy. Monte Carlo simulation is applied to deal with multiple stochastic sensor inaccuracy and provide probabilistic analysis results of the impact of sensor inaccuracy on sensor selection and FDD accuracy. This methodology focuses on the net impact of fault states across a full sensor set. The developed methodology can be used for the early-stage sensor design and operation-stage sensor maintenance. Furthermore, a case study is conducted to demonstrate the analysis methodology using a commercial building model crated to Flexible Research Platform located at Oak Ridge National Laboratory, USA.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Deep in Data: Empirical Data Based Software Accuracy Testing Using the Building America Field Data Repository: Preprint

An opportunity is available for using home energy consumption and building description data to develop a standardized accuracy test for residential energy analysis tools. That is, to test the ability of uncalibrated simulations to match real utility bills. Empirical data collected from around the United States have been translated into a uniform Home Performance Extensible Markup Language format that may enable software developers to create translators to their input schemes for efficient access to the data. This may facilitate the possibility of modeling many homes expediently, and thus implementing software accuracy test cases by applying the translated data. This paper describes progress toward, and issues related to, developing a usable, standardized, empirical data-based software accuracy test suite.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Improving and Automating Building Model Data Exchange

There are many instances throughout a project’s lifecycle where there arises a need for quick and accurate risk assessment of building designs. For example, an unexpected design change during construction may necessitate structural engineers to perform a seismic risk assessment on analytical models of the updated building design using high fidelity structural analysis software, such as ANSYS or Abaqus. However, the efficiency of such workflows often depends upon the interoperability of architectural design software and structural analysis software. When the quality of this interoperability is lacking or even non-existent, the efficiency of virtual engineering workflows is hampered, which increases project costs. A McGraw Hill industry survey of professional users of Building Information Modeling (BIM) technologies found that there is high demand for BIM interoperability for structural analysis, but that the value/difficulty ratio is currently too low for practical use. There have been efforts by the academic community to facilitate model data exchange between the architectural design and structural analysis domains, but such solutions have not been widely adopted by industry, face technical challenges, and oftentimes are limited in applicability for users of various BIM software. Therefore, INL is developing capabilities to improve, automate, and generalize model data exchange between architectural BIM software (e.g., Revit) and structural analysis software (e.g., SAP2000, ANSYS). The goal is to help expedite and automate as much of the pre-processing step for creating analytical models in finite element analysis software as reasonably as possible. Such a "BIM-to-FEA" conversion tool should provide direct benefit to end-users through accuracy, automation, quick turn-around, and wide applicability. To generalize the application of this BIM-to-FEA conversion tool and increase its useability among the many different commercial BIM software currently used by industry, the program is being developed with the concept of openBIM. OpenBIM is the application of non-proprietary, open data standards that allow for BIM model data exchange in a format that is accessible, retainable, and useable for all users. The most widely used open, non-proprietary data exchange format for BIM is the Industry Foundation Classes (IFC) schema. IFC is developed by buildingSMART international and is ISO certified (ISO 16739-1:2018). The BIM-to-FEA conversion tool is being developed for compatibility with typical commercial building designs of steel framed structures. The tool is currently capable of importing architectural BIM data of framed building structures, recognizing and extracting the aspects of the model that are required for structural analysis, adjusting the connectivity of frame members, and finally exporting to an analytical model stored in the IFC format. The exported IFC analytical model can then be imported into various openBIM compliant software, such as SAP2000. Such capabilities have already been tested on commercial software, as shown above, and continue to be improved. Work is underway to test the conversion on various commercial BIM software, develop a user-friendly interface, incorporate the program into the broader DeepLynx data warehouse project being developed by INL, and to eventually open-source the tool for the benefit of the community. Future development of the tool envisions the ability for efficient iterative risk assessment of generative building designs, all within a workflow utilizing open-source tools. One such open-source tool will be MOOSE, an advanced finite element analysis tool developed at INL. The conversion tool will also branch out from typical commercial building designs and will aim to incorporate nuclear construction. The aim will be to convert both structural and non-structural components of nuclear facilities, such as curved concrete containment structures and piping systems, respectively.

97 MATHEMATICS AND COMPUTING↗

Deep in Data: Empirical Data Based Software Accuracy Testing Using the Building America Field Data Repository

This paper describes progress toward developing a usable, standardized, empirical data-based software accuracy test suite using home energy consumption and building description data. Empirical data collected from around the United States have been translated into a uniform Home Performance Extensible Markup Language format that may enable software developers to create translators to their input schemes for efficient access to the data. This could allow for modeling many homes expediently, and thus implementing software accuracy test cases by applying the translated data.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Charge densities in actinide compounds: strategies for data reduction and model building

The data quality requirements for charge density studies on actinide compounds are extreme. Important steps in data collection and reduction required to obtain such data are summarized and evaluated. The steps involved in building an augmented Hansen–Coppens multipole model for an actinide pseudo-atom are provided. The number and choice of radial functions, in particular the definition of the core, valence and pseudo-valence terms are discussed. The conclusions in this paper are based on a re-examination and improvement of a previously reported study on [PPh 4 ][UF 6 ]. Topological analysis of the total electron density shows remarkable agreement between experiment and theory; however, there are significant differences in the Laplacian distribution close to the uranium atoms which may be due to the effective core potential employed for the theoretical calculations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Methodology to Assess No Touch Audit Software Using Simulated Building Utility Data

This report describes a methodology developed for assessing the performance of no touch building audit tools and presents results for an available tool. Building audits are conducted in many commercial buildings to reduce building energy costs and improve building operation. Because the audits typically require significant input obtained by building engineers, they are usually only affordable for larger commercial building owners. In an effort to help small building and business owners gain the benefits of an audit at a lower cost, no touch building audit tools have been developed to remotely analyze a building's energy consumption.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Metadata Schemas and Ontologies for Building Energy Applications: A Critical Review and Use Case Analysis

With the increasing digitalization of processes throughout the lifecycle of buildings, data exchanged between stakeholders and between building systems has grown significantly. However, a lack of semantic interoperability between data in different systems is still prevalent, hindering the development of applications that can be reused across buildings and limiting the scalability of innovative solutions. Semantics refers to the description of the meaning of the data in a way that can be consistently understood by applications. Recently, several competing initiatives have been developing metadata schemas and ontologies to express this semantic information for different applications in the building domain. This paper systematically reviews these schemas and conducts an analysis of five of them to evaluate their applicability to three high-value use cases for building operations: energy audits, automated fault detection and diagnostics and optimal control. The survey finds 40 schemas published in the last 10 years but but their actual use in industry is difficult to estimate. Among the five selected ontologies, several gaps are highlighted in relation to the three use cases. Recommendations for the future include better harmonization of these initiatives, more centralized repositories and search engines for these schemas as well as better industry engagement to facilitate their adoption.

Smart Building, Sematic, Metadata, Ontology, Data ↗

An improved method for direct incident solar radiation calculation from hourly solar insolation data in building energy simulation

Solar radiation considerably influences the energy consumption of buildings and the power production of building integrated photovoltaic (BIPV) systems. Hourly solar insolation (Wh/m 2 ), represented as the amount of solar irradiance collected on the ground during a 1-h period, is the most common solar radiation data available and widely used in weather files applied in building energy modeling programs (BEMPs). Because the solar beam and position vary over time, the use of hourly insolation data as the input might result in errors in the estimation of the direct incident solar radiation on a particular surface. In this study, methods used in BEMPs for direct incident solar radiation calculations are first analyzed, and an improved method adopting a new algorithm for estimating the solar irradiance is proposed. Furthermore, the algorithm assumes that the solar irradiance changes linearly within a 1-h period and can be estimated based on the solar irradiance at the half clock and slope. The collected direct normal solar irradiance data of 2016 from eight solar radiation stations in China were used to demonstrate the proposed method and evaluate its performance by comparing the results with those from three conventional methods used in BEMPs along with the ground truth measurements. In addition, in this study, factors affecting the accuracy of the calculation results are explored. The results of the estimated direct incident solar radiation show that the proposed method achieves the best accuracy, followed by the methods used in DOE-2, EnergyPlus, and DeST. The proposed method guarantees that the hourly direct solar insolation will remain the same and reflects the variation in the direct solar irradiance across a 1-h time frame. The proposed method can be adopted in BEMPs to improve the accuracy of the solar radiation calculation, thereby improving the accuracy of the simulated building performance and the BIPV production.

14 SOLAR ENERGY↗

Datasets of a Multizone Office Building under Different HVAC System Operation Scenarios

Abstract This study provides an open-source dataset of the measured weather data, building indoor data, and system data under the different test settings. The test building is the two-story Flexible Research Platform building at the US Department of Energy’s Oak Ridge National Laboratory, in Oak Ridge, Tennessee. Four heating tests and three cooling tests were conducted. The 1-min interval of weather, building indoor data, and system data from each test setting are provided. Actual weather data were collected from a weather station installed on the roof. This paper describes information on the test building and installed sensors, data collection method, and data validation. The provided dataset can be employed to understand HVAC system conditions and building indoor conditions under different HVAC system operations and the performance of building envelope without HVAC system operation using free-floating test data. Additionally, it can be used for empirical validation of the building energy modelling engine.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

How close are urban scale building simulations to measured data? Examining bias derived from building metadata in urban building energy modeling

Residential and commercial buildings in the United States accounted for 40% of total energy in 2020. Building energy modeling (BEM) is a useful tool that allows individuals, researchers, companies, or utilities to save energy by optimizing buildings through estimation of building technology savings and performance projection of building energy under various environmental conditions. Urban building energy modeling (UBEM) expands the scope beyond individual buildings to the buildings in a neighborhood, city, utility and more. Yet there is a knowledge gap in the literature as to how these models compare to measured data on an individual and aggregated basis. As UBEM data and methods continue to develop, it is important to consider the accuracy, bias, and limitations of the models. Here, nation-scale data and UBEM software suite named Automatic Building Energy Modeling (AutoBEM) was used to model 50,843 buildings in Chattanooga, Tennessee. The uncalibrated simulation results were compared to aggregated 15-minute electricity data for the year 2019 with visualizations highlighting sources of bias in building data and the AutoBEM framework while considering how they relate to other UBEM methods. Estimation of building type and year of constructions are found to be the major sources of bias. Accounting for the amount of conditioned area per building significantly improves the overall fit of the simulated energy use intensity. it was found that inherent variation in building energy use contributes to R 2 values between 0.008 and 0.095 across building types but slope values near 1 for the total number of buildings. This indicates the need for building aggregation for representative building energy modeling with data sources available at an urban scale while illustrating the need for additional individual building data and model improvement beyond the originally produced UBEM models for individual building analysis.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗