Search NASA⌕ Search

SEARCH · Search NASA

Results for “Building energy and control system”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

EMPIRICAL VALIDATION OF MULTI-ZONE BUILDING AND HVAC SYSTEM MODELS UNDER UNCERTAINTY

This study implemented a framework of empirical validation of building energy models under uncertainty to a set of controlled experiments that aim to validate multi-zone building and HVAC system models. Energy models were created through iterative acquisitions of information and data and uses measurement data from various types of sensors as both inputs and as observations to validate predictions. Experimental and modeling uncertainties were quantified and propagated accordingly, and probabilistic accuracy metrics were used to evaluate the agreement between model predictions and observations under uncertainty. Sensitivity analysis was performed to identify the most influential uncertainties that will be prioritized to be addressed in the next steps. Current results of two cooling tests show an overall good agreement between predictions and observations on a set of HVAC system outputs despite considerable and influential uncertainty in DX cooling coil COP. Agreements on zone-level responses vary notably among individual rooms, likely because of significant uncertainties in room radiation heat gain and system supply air.

Li, Qi↗

Laboratory Validation of Integrated Lighting Systems Retrofit Performance and Energy Savings

Light-emitting diodes (LED) fixtures and lamps have emerged as leading technologies for general illumination and are a well-established energy efficiency retrofit measure in commercial buildings (from around 2% of installed fixtures and lamps in 2013 to 28% by 2020). Retrofit approaches that integrate elements, such as networked controls, daylight dimming, and advanced shade technologies lag in comparison. Integrated retrofits have been shown to increase savings over single end-use retrofits, but are perceived as higher complexity and risk. More validation of integrated lighting system performance is needed. This study presents results from laboratory testing of three packages combining fixtures, networked controls, task tuning, and daylight dimming, advanced shades, and lighting layout changes. We characterize performance in perimeter open-office zones, finding energy savings from 20% for daylight dimming and automated shades (no LED retrofit) to over 70% for LED retrofits with advanced controls and shades or lighting layout changes. We present some implementation details, including lessons learned from installation and commissioning in the laboratory setting. We also discuss cost-benefit analysis approaches for the types of packages presented, including the need to quantify and incorporate energy and non-energy benefits for advanced shades packages, which enhance occupant comfort but add significant cost.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Potential Cooling Energy Savings of Economizer Control and Artificial-Neural-Network-Based Air-Handling Unit Discharge Air Temperature Control for Commercial Building

Heating, ventilation, and air-conditioning (HVAC) systems play a significant role in building energy consumption, accounting for around 50% of total energy usage. As a result, it is essential to explore ways to conserve energy and improve HVAC system efficiency. One such solution is the use of economizer controls, which can reduce cooling energy consumption by using the free-cooling effect. However, there are various types of economizer controls available, and their effectiveness may vary depending on the specific climate conditions. To investigate the cooling energy-saving potential of economizer controls, this study employs a dry-bulb temperature-based economizer control approach. The dry-bulb temperature-based control strategy uses the outdoor air temperature as an indicator of whether free cooling can be used instead of mechanical cooling. This study also introduces an artificial neural network (ANN) prediction model to optimize the control of the HVAC system, which can lead to additional cooling energy savings. To develop the ANN prediction model, the EnergyPlus program is used for simulation modeling, and the Python programming language is employed for model development. The results show that implementing a temperature-based economizer control strategy can lead to a reduction of 7.6% in annual cooling energy consumption. Moreover, by employing an ANN-based optimal control of discharge air temperature in air-handling units, an additional 22.1% of cooling energy savings can be achieved. In conclusion, the findings of this study demonstrate that the implementation of economizer controls, especially the dry-bulb temperature-based approach, can be an effective strategy for reducing cooling energy consumption in HVAC systems. Additionally, using ANN prediction models to optimize HVAC system controls can further increase energy savings, resulting in improved energy efficiency and reduced operating costs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

An encoder–decoder LSTM-based EMPC framework applied to a building HVAC system

Numerous studies have demonstrated the benefit of economic model predictive control (EMPC) applied to building heating, ventilation, and air conditioning (HVAC) systems. However, the construction and training of predictive models for building HVAC systems are widely recognized as a key technological barrier preventing large-scale adoption of EMPC for buildings. In this work, an encoder–decoder long short-term memory-based EMPC framework is developed. The key advantage of the approach is that a model may be automatically generated from a list of inputs and outputs. From the definition of inputs and outputs, the constructed model may be trained and automatically embedded into the EMPC framework for real-time estimation and control. The overall end-to-end EMPC framework from model training to on-line estimation and control are described. To this end, the encoder–decoder model provides a natural framework for state estimation (encoder), which is required to provide an initial condition for the predictive model of EMPC (decoder). Closed-loop simulations using EnergyPlus are performed to demonstrate the approach. The simulated closed-loop system consists of a building zone from a multi-zone building, which is served by an air handling unit-variable air volume HVAC system. For the HVAC example considered, the trained encoder–decoder model can predict the indoor air temperature and HVAC sensible cooling rate of a building zone over a two-day horizon with high accuracy. Overall, we find that considering a time-of-use electric rate structure, the EMPC, which manipulates the zone temperature setpoint, can reduce the HVAC power consumption cost relative to keeping the zone temperature setpoint at its maximum value (i.e., minimum energy approach).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Cluster analysis of occupancy schedules in residential buildings in the United States

The energy performance of residential buildings significantly depends on the building occupants’ behavior, which can be highly variable. When the heating, ventilation and air conditioning (HVAC) system is controlled based on the presence or absence of occupants in a building, occupant behavior is of even further importance to its energy performance. In current practice, building energy simulation tools generally use a single occupancy profile to represent the building’s occupancy schedule, the schedule of which is considered to be the same, regardless of the type of household being modeled. Thus, there is significant potential for improvement to allow for more flexibility and accuracy in calculation of occupancy. The objective of this study is to assess the variations in the typical types of occupancy schedules followed by the U.S. population using cluster analysis. American Time Use Survey data, which statically represents the overall U.S. population’s activities, across 12 years (2006–2017), is used. The ATUS data is segregated into smaller groups based on age and weekday/weekend, then divided into activities that are considered “at home” and “away from home”, which are mapped to the presence or non-presence of occupants in the home. Cluster analysis is then used to identify common types of occupancy schedule patterns for each age group. Three main types of patterns are obtained from cluster analysis for each age group, which together represent approximately 88% of people in the United States. The output of the cluster analysis is further analyzed to evaluate the variation in characteristics, including the number of times leaving home, time of day when leaving the home, and the timespan of absence from the home. The results of this study provide detailed insights on how typical occupants in the United States spend their time in residential spaces which can be used to create occupancy profiles for residential buildings. Finally, these occupancy profiles could be utilized inform an assessment of the energy use impact of occupancy-based controls of energy consuming systems and technologies.

42 ENGINEERING↗

Data-Driven Modeling and Optimization of Building Energy Consumption: a Case Study

Installing sensors and Building Automation Systems (BAS) allows controlling the facility operations while generating data that can be analyzed for model development. This work focuses on data-driven modeling of the building to optimize energy consumption. The City of Orlando aims to reduce its energy consumption so, they provided us access to their BAS for data and studying the operation of its facilities. We selected a mid-size pilot building to conduct data analysis and modeling. We develop an Application Programming Interface (API) to login to the servers and scrape data. The scraped data contains features ranging from environmental conditions to equipment activity. This dataset is a time series so, it's handled in accordance and analyzed to investigate patterns and relations between data points that help choose parameters for predictive models for building and equipment. Finally, the models are optimized to reduce the energy consumption of the facility.

Grover, Divas↗

Multi-Fidelity Modeling and Control for Building Temperature Control

The ability to control energy loads such as a building's heating, ventilation, and air conditioning (HVAC) system can help facilitate increased penetration of variable renewable energy sources into the electric grid. To be able to control these HVAC systems more effectively, detailed simulations of the corresponding building physics is becoming increasingly important. These detailed simulations can be complex, nonlinear, and can require immense computational power when used in an advanced control method such as model predictive control (MPC), prompting the need to explore less computationally intensive strategies. In this work, a multi-fidelity approach is proposed to combine samples from a complex, high-fidelity model with a simple, low-fidelity model within the MPC control loop. More specifically, the parameters of a reduced-order, linear building model are periodically updated with knowledge from its high-fidelity counterpart - an EnergyPlus model - in an online fashion using a Gaussian Process surrogate model. Hence, highly accurate predictions of current and future conditions in a building are maintained with a substantially reduced computational burden compared to using the high-fidelity models alone. In other words, this linear parameter varying model preserves the low computational requirements of a low-order linear model while accurately modeling a building's dynamics. This allows a building controller to take highly informed actions without requiring a large computational budget.

building modeling↗

Developing a Control Strategy for Minimum Airflow Setting Considering CO2 Level and Energy Consumption in a Variable Air Volume System

In an office building equipped with a Variable Air Volume (VAV) system, this paper introduces a novel method for controlling the minimum supply airflow fraction in each zone’s VAV box, having a capability to consider indoor CO2 level and energy consumption. The EnergyPlus simulation using the medium office prototype model was employed, which evaluated the performance of the energy and CO2 concentration for five VAV box airflow control strategies. The paper focuses on CO2 concentration-based airflow control method and compares it with other four methods including conventional single-max, reduced minimum single-max, demand-controlled ventilation(DCV), and dualmax control methods according to guidelines and common practices. The newly proposed control strategy directly correlates the minimum airflow fraction to CO2 concentration. A general trend emerged when comparing CO2 concentrations—lower minimum airflow fractions were associated with higher concentrations. The proposed control method effectively maintained low CO2 concentrations and enabled a lower airflow fraction contributing to energy consumption reduction. It was confirmed that heating energy consumption in climate zone 4A, 5B, and 6A showed a maximum saving of approximately 30% compared to the conventional single-max and dual max control strategies. It was found that cooling energy consumption in climate zone 4A and 6A can achieve a maximum saving of approximately 10% compared to the conventional control strategies. The proposed CO2 concentration-based control logic is promising as it not only improves the indoor air quality lowering the CO2 concentration in the occupied spaces, but also contributes to HVAC energy savings.

Lee, Jong Man↗

Cloud-Control of Legacy Building Automation System: A case study

As Internet of Things devices and cloud-based platforms become more mature, Energy Management and Information Systems (EMIS) are increasingly gaining momentum in the building industry. In large commercial buildings, Fault-Detection and Diagnostic (FDD) and energy information systems (EIS) are now established technologies with tens of providers and thousands of deployment sites across North America. The new frontier for the EMIS technology is now represented by control systems that use advanced system optimization (ASO) methods to improve the operations of the HVAC system. Given the complexity of the integration of such systems with the existing building automation systems (BAS) and the higher risk involved with direct control of the HVAC, these systems are still emerging in the market. This paper presents the results of a project in which a start-up company partnered with a research institution to develop a cloud-based software EMIS solution and deployed it in a university campus in California. The software system included advanced sensing, data acquisition, storage and advanced control and analytics applications developed on top of the native BAS. The new platform controls ten buildings on the campus and the FDD and the ASO applications deployed on this platform were able to generate energy savings of up to 35% and 25% in certain buildings for each functionality respectively. Where the platform did not save energy, it improved building service (air quality). Lessons learned include the importance of collaborating with and training the building operators and evaluating whether the legacy system can work reliably with the new technology.

Prakash, Anand Krishnan↗

Enhancing Building Energy Efficiency through Advanced Sizing and Dispatch Methods for Energy Storage

Energy storage and electrification of buildings hold great potential for future decarbonization. However, there are several technical and economic barriers that prevent large-scale adoption and integration of energy storage in buildings. These barriers include integration with building control systems, high capital costs, and the necessity to identify and quantify value streams for different stakeholders. To overcome these obstacles, it is crucial to develop advanced sizing and dispatch methods to assist planning and operational decision-making for integrating energy storage in buildings. This work develops simple and flexible optimal sizing and dispatch framework for thermal energy storage (TES) and battery energy storage (BES) systems in large-scale office building. The optimal sizes of TES, BES, as well as other building assets are determined in a joint manner instead of sequentially to avoid sub-optimal solutions. The interaction between the sizing at the planning stage and hourly or sub-hourly dispatch at the operating stage is explicitly modeled. The solution is determined considering both capital costs in optimal sizing and operational benefits in optimal dispatch. Comprehensive assessments are performed using simulation studies to quantify potential energy, economic, and emission benefits by different utility tariffs and climate locations, to improve our understanding of the techno-economic performance of different TES and BES systems, and to identify barriers for adopting energy storage for buildings. Finally, the proposed framework will provide guidance to a broad range of stakeholders to properly design energy storage in buildings and maximizes potential benefits, thereby advancing affordable building energy storage deployment and helping us accelerating the transition towards a cleaner and more equitable energy economy.

Yu, Mingyung↗

Machine Learning for Automated Metadata Assignment in Buildings: Cooperative Research and Development (Final Report, CRADA Number CRD-18-00767)

RealTerm Energy and NREL have identified a shared vision to evaluate opportunities to facilitate the organization and assignment of metadata to building control system (BCS) data via industry-informed machine learning (ML). Manual metadata assignment is labor intensive and costly, slowing down any Energy Management and Information System (EMIS) deployment in the building space. This project aims to develop methodologies to accurately assign this metadata and significantly decrease the level of effort associated with deploying EMIS. The objective of this project is to identify/design methodologies to assign metadata to HVAC control points automatically. The identified methodologies will be programmed in analytics algorithms so they can ingest a list of points and produce a detailed tagging following the Haystack classification nomenclature. To validate the efficacy of each methodology, tagging results will be compared utilizing a list of points extracted from RealTerm's building database-as well as data extracted from the NREL campus via the Intelligent Campus program-enabling testing against large datasets with real world challenges. The developed methodologies may leverage building manager/operator input on a limited basis to add context to the classifying algorithms. The partnership aims to advance global efforts in areas related to the DOE missions through improving operational performance of commercial buildings. It is well documented that buildings fall out of commission after they are occupied, wasting significant energy and incurring associated costs simply due to poor operational performance. Emerging EMIS technologies that perform continuous commissioning help to address this issue, yet integration of these systems can be labor intensive both for the technology vendor and the building owner/operator. This project will enable more efficient and cost-effective analytics for buildings, enabling improvement in building operations at lower cost points.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Flexible Reinforcement Learning Framework for Building Control using EnergyPlus-Modelica Energy Models

In recent years, reinforcement learning (RL) methods have been greatly enhanced by leveraging deep learning approaches. RL methods applied to building control have shown potential in many applications due to their ability to complement or replace conventional methods such as model-based or rule-based controls. However, RL-based building control software is likely tailored either to one target building system or to a specific RL method so that significant additional effort would be required to customize the RL-based controller for use in other building systems or with other RL approaches. Also, RL-based building controls usually depend on building energy simulations to train controllers, so emulating building dynamics (i.e., thermal dynamics and control dynamics) and capturing sub-hourly dynamic profiles are crucial to further the development of effective RL-based building control methods. To address these challenges, we present an open source RL-based control software employing a high-fidelity hybrid EnergyPlus-Modelica building energy model which emulates building dynamics at 1-minute resolution. This software consists of decoupled components (environment, building emulator, control agent, and RL algorithm), which allows for quick prototyping and benchmarking of standard RL algorithms in different systems; for example, a single component can be replaced without revising all of the software. To demonstrate this software framework, we conducted a benchmark study using an EnergyPlus-Modelica building energy model for a Chicago office building with an RL-based controller to dynamically control the chilled water temperature setpoint and the air handling unit supply air temperature setpoint on selected floors.

Lee, Joon-Yong↗

Variable Refrigerant Flow Performance: Humidity and Efficiency in Multifamily Buildings in New York, NY

Variable refrigerant flow (VRF) systems have become common in large multifamily buildings. The upfront cost is appealing to developers, as a single system can provide all heating and cooling. VRF systems also use no on-site fossil fuels which can help avoid greenhouse gas emissions. However, there have been very few data on how VRF systems actually perform in buildings. Researchers monitored three new, multifamily buildings with a focus on VRF system sizing, humidity control, and energy efficiency.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Guideline 36 Conformance Test v2.0

ASHRAE Guideline 36 provides guidance for how typical commercial building HVAC systems should be controlled to reduce energy costs and improve the indoor environmental quality for occupants. An industry-led effort is developing test scripts for how control manufacturers can test that the control logic in their control products follows Guideline 36. This software intends to support that effort in two ways. First, by providing a testbed for control manufacturers to run the test scripts against their own control products and compare their generated results to the expected results provided by the test scripts. Second, by providing a testbed that can be used during the development of test scripts to rapidly and repeatably verify they exercise Guideline 36 logic as desired and generate accurate expected results that control products can be compared to. An initial version of the software has already been developed and released open-source by a previous CEC-funded project that implemented the first use case (https://github.com/LBNL-ETA/guideline36_conformance_test/blob/master/LICENSE.txt), while this software disclosure will add the functionality of the second use case, as well as update the software where needed, all open-source. We intend to extend and contribute to the existing open-source software repository.

Blum, David [Lawrence Berkeley National Laboratory↗

Design Requirements and Hardware Specification for the Low-Cost, Interoperable, User-Centric, Supervisory Controller Kit for Small and Medium Size Commercial Buildings

Commercial buildings are responsible for approximately 20 percent of the total United States energy consumption and greenhouse gas emissions. Over 85 percent of these buildings lack building automation systems to manage the various building systems they have. Many of these buildings are small (< 50,000 square feet), underserved, and use rooftop units (RTUs) for heating, ventilation, and air-conditioning needs. Because these buildings lack proper control systems, they have several operational deficiencies that lead to excess energy consumption. Studies have shown that managing the RTU’s heating and cooling setpoints, schedules, setbacks, and optimal start times can result in 20 to 25 percent reduction in electricity consumption in small and medium commercial buildings (SMBs). In addition, improving the demand flexibility of these buildings will result in additional cost savings for the building owner.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Field Demonstration of the Brick Ontology to Scale up the Deployment of ASHRAE Guideline 36 Control Sequences

Many commercial buildings have a vast network of sensors as part of their building automation systems (BAS) that allows opportunities for energy consumption and cost savings by deploying advanced control sequences. However, this resource is often underutilized since BAS are typically programmed with simple control sequences with limited potential to deliver on these opportunities. The recent availability of ASHRAE Guideline 36 (G36) with advanced HVAC control sequences supports control retrofits in existing buildings to unlock much of the savings potential. However, barriers such as the lack of standard naming convention of building assets and data points, proprietary equipment and BAS, and the inherent uniqueness of buildings and their systems prevent building stakeholders from adopting any “plug-and-play” implementation of G36. Instead, control vendors must often undertake the manual and labor-intensive point mapping process to identify a data stream’s functional and spatial relationship within the HVAC system along with other relevant contexts and map it to the new control sequences. The vendor must carry out the point mapping process in each individual building since the mapping is unlikely to port over to another building. Even for the same building, the point mapping process can occur multiple times if various control vendors implement different control retrofits and/or multiple control retrofits happen over the lifecycle of the building. Then, there is the likelihood that G36 control sequences are programmed uniquely to the building, preventing the same implementation from being reused in another. Therefore, this paper presents a field demonstration of how we leveraged the Brick ontology with BACnet, OpenBuildingControl’s Control Description Language (CDL), and open-source support tools to implement scalable and portable advanced building controls. These tools provide standardized semantic descriptions and relationships of the building’s assets and data points (Brick), standardized communication protocol to read from and write to the building’s BAS (BACnet), and standardized code implementations (CDL) of standardized advanced control strategies (G36). We implemented G36’s hot water supply temperature setpoint reset in a Berkeley, CA building for this field demonstration. This field demonstration aims to show how integrating these tools may streamline the deployment of advanced control sequences such as G36 in a consistent manner regardless of differences found across buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗