Search NASA⌕ Search

SEARCH · Search NASA

Results for “Building energy flexibility”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Performance analysis of novel thermal storage integrated heat pump system in a residential building at the hot climate for demand flexibility

A novel thermal energy storage integrated heat pump system was proposed to reshape the electricity load profile of residential buildings while maintaining thermal comfort. High-fidelity computer simulations are needed for evaluating the feasibility of the proposed system. This study investigates the annual performance of the proposed system through Modelica-based system simulations. A rule-based control strategy was developed to shift the electric demand of a typical single-family house in Atlanta, GA from peak to off-peak hours to utilize the Time-of-Use electricity rate to lower the energy costs for conditioning the building. For comparison, a conventional air-source heat pump system serving the same building was also developed. Simulation results indicate that the proposed system is capable of shifting around 90% of the building's electricity consumption for meeting the thermal demand from peak to off-peak hours on a daily basis. In addition, the annual power consumption and operating cost for running the HVAC system can be reduced by 6% and 34%, respectively, compared with the conventional air-source heat pump.

Shi, Liang↗

State-of-the-art on research and applications of machine learning in the building life cycle

Fueled by big data, powerful and affordable computing resources, and advanced algorithms, machine learning has been explored and applied to buildings research for the past decades and has demonstrated its potential to enhance building performance. This study systematically surveyed how machine learning has been applied at different stages of building life cycle. By conducting a literature search on the Web of Knowledge platform, we found 9579 papers in this field and selected 153 papers for an in-depth review. The number of published papers is increasing year by year, with a focus on building design, operation, and control. However, no study was found using machine learning in building commissioning. There are successful pilot studies on fault detection and diagnosis of HVAC equipment and systems, load prediction, energy baseline estimate, load shape clustering, occupancy prediction, and learning occupant behaviors and energy use patterns. None of the existing studies were adopted broadly by the building industry, due to common challenges including (1) lack of large scale labeled data to train and validate the model, (2) lack of model transferability, which limits a model trained with one data-rich building to be used in another building with limited data, (3) lack of strong justification of costs and benefits of deploying machine learning, and (4) the performance might not be reliable and robust for the stated goals, as the method might work for some buildings but could not be generalized to others. Finally, findings from the study can inform future machine learning research to improve occupant comfort, energy efficiency, demand flexibility, and resilience of buildings, as well as to inspire young researchers in the field to explore multidisciplinary approaches that integrate building science, computing science, data science, and social science.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Open Building Control

Best practice control sequences are often not implemented correctly, or are not implemented at all, in large commercial buildings. This typically leads to 10-30 percent energy waste, along with reduced occupant productivity and unnecessary equipment wear. The current process of designing and implementing such control sequences is a manual process that starts with designers who often don’t have adequate training, then requires controls programmers to interpret and program a verbose written sequence. This process has been shown to fail to deliver high performance control sequences at scale. The Open Building Control project digitizes the current control delivery process. The project is developing tools for system designers to select control sequences, assess their energy performance and load flexibility potential using whole building simulation, specify the sequence for implementation using machine-to-machine translation by a control provider and formally testing the as-installed sequences by a commissioning agent. The project developed tools for each stage of this delivery process. The key innovation of the project is the development of the Control Description Language, a language that allows such a digitized control delivery process with end-to-end verification. Libraries of control sequences have been implemented using the Control Description Language, and their performance has been demonstrated using whole building energy simulation. An automated translation of such sequences to a commercial control product line has been conducted using a prototype translator. Tools for formal verification of as-installed control sequences relative to their specification have been developed and demonstrated. The American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE) started the process of forming a committee to make this language an ASHRAE/ANSI Standard. This new standard will complement existing and emerging ASHRAE standards for building communication and semantic modeling by providing a standard for expressing the control logic - the actual brain of the building. We expect this language and the process it enables to be an important contribution to the deployment of high performance building control sequences at scale because it allows taming the complexity of the control delivery process, which is continually increasing due to the need for higher performance and increased load flexibility to meet goals for net zero energy and increased renewable integration.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Preliminary Sensitivity Analysis for Sensors Impacts on Building Control Performance

This report describes the preliminary sensitivity analysis for sensor impacts on building control performance through the US Department of Energy’s Oak Ridge National Laboratory’s Flexible Research Platform (FRP-2) building. The rooftop unit system provides cooling and heating to the building. The main heating coil is a gas heating coil. Each zone is served by a variable air volume box with an electricity reheat coil. The rooftop unit and variable air volume box controls adopted the practical control sequences from ASHRAE Guideline 36-2018: High-Performance Sequences of Operation. For sensors, the incipient (time-changing) sensor errors, including bias sensor error and precision sensor error, are the inputs of interest. The outputs are energy consumption and thermal comfort (e.g., the predicted percentage of dissatisfied occupants). The large-scale simulation (3,600 cases) was conducted on a cloud platform by integrating sensor errors and ASHRAE Guideline 36 control sequences into an emulator based on the EnergyPlus simulation program with Python energy management system feature. The surrogate models were developed based on cloud simulation results. The uncertainty analysis showed that the sensor errors substantially affect building energy consumption and thermal comfort. The sensitivity analysis shows a ranking of sensor error impacts for each interested output item (e.g., cooling energy, reheat coil heating energy, predicted percentage of dissatisfied occupants). In FY 2022, sensor locations, types, and costs will be evaluated. The field test in Oak Ridge National Laboratory’s Flexible Research Platform building regarding sensor impacts will also be performed. Finally, a comparative analysis will be conducted based on the field test results and emulator results.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

National Energy Education Development Project (NEED Project) (CRADA Final Report)

The U.S. Department of Energy Building Technologies Office (BTO) funds student competitions that introduce students to careers in the building sciences and increase public awareness around high-performance buildings to support the goal of developing, demonstrating, and accelerating the adoption of cost-effective technologies, techniques, tools, and services that enable high-performing, energy-efficient and demand-flexible residential and commercial buildings in both the new and existing buildings markets. The U.S. Department of Energy Solar Decathlon® (DOE/SD) is a flagship, high-visibility international competition started in 2002 that advances the goals of BTO by introducing students to building science careers; educating students and the public about the latest technologies and materials in high-performance buildings; encouraging student-led projects and research centered around building science; and demonstrating to the public the comfort and savings of homes that combine energy-efficient construction, home systems, appliances and innovative design with onsite renewable energy production. SD is a collegiate competition, comprising 10 contests, that challenges student teams to design and build highly efficient and innovative buildings powered by renewable energy. The winners will be those teams that best blend architectural and engineering excellence with innovation, market potential, building efficiency, and smart energy production. Solar Decathlon is comprised of two Challenges – Design Challenge (annual) and Build Challenge (biennial). The National Renewable Energy Laboratory (NREL) provides competition management for Solar Decathlon. NREL and Participant establish this CRADA to enable the success of the overall Solar Decathlon program by managing sponsorship funds and creating a K12 education program. Participant is to act as an Education Partner to Solar Decathlon, which includes: 1) accepting and dispersing sponsorship funds for DOE/SD; and 2) providing K12 education program to support Solar Decathlon Competition Events in April each year.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

An Assessment of Impacts on Electric End-Use Load Profile of a Typical Residential Building from a Ground Source Heat Pump Systems Integrated with Underground Thermal Energy Storage

Buildings are the primary users of electricity, and a considerable amount of electric energy consumed in residential and commercial buildings is for meeting thermal demands (e.g., space heating/cooling, water heating, etc.). Therefore, integrating thermal energy storage with a building’s energy system has the potential to reshape the electric load profile of the building and mitigate the mismatch between the renewable power supply and the thermal demands of buildings. A novel ground-source heat pump system (GSHP) integrated with underground thermal energy storage (UTES) has been developed to enable flexible electric demand at buildings while meeting their thermal demands with an energy-efficient GSHP system. This paper assessed the potential impacts of the proposed system on the peak electrical demand and annual electricity consumption in a typical residential building at various climate zones in the United States. The results show that by replacing the conventional HVAC system (air conditioner and natural gas furnace) with the UTES integrated GSHP system, summer peak electric demand can be reduced by 27% to 50% depending on the weather. Although the winter peak electrical demand could be increased by up to 70% if the proposed system replaces natural gas furnace, the existing electricity supply system for single-family homes in most regions of the United States have adequate capacity for the replacement. While eliminating the natural gas consumption for space heating, the proposed system consumes more electricity on an annual basis in heating-dominated regions. However, it consumes less electricity in cooling dominated regions. The resulting variance in annual electricity consumption in various climate zones is within 15% compared with the baseline system.

Shi, Liang↗

GT Flex: A Coordinated Multi-Building Pilot Study

Buildings are a significant and untapped resource for providing utility electric grid services. Recent studies have estimated that buildings could reduce the peak demand on the electric grid in the U.S. by almost 25% through effective combinations of energy efficiency (EE) measures and load flexibility strategies (Langevin et al. 2021). The U.S. Department of Energy (DOE) has established a goal to triple energy efficiency and demand flexibility in both residential and commercial sections by 2030 compared to 2020 levels (Satchwell et al. 2021). Such findings place buildings alongside electric vehicles, photovoltaics, electric batteries, and other distributed energy resources (DERs) as primary technologies needed for supporting high renewable energy generation grids. Coordinating and optimizing multiple buildings and other DERs is more beneficial and valuable when compared with individual buildings and DERs operating as siloed resources, uncoordinated with others (Olgyay et al. 2020). A pilot study at the Georgia Institute of Technology (GIT) was conducted to evaluate value propositions of a multi-building scale project seeking carbon reduction, energy efficiency and grid-interactive capabilities, by demonstrating the means by which stakeholders can determine the technical and financial merits of grid-interactivity and energy efficiency technologies coordinated across multiple assets. The study focused on analyzing technical feasibility of deploying thermal load flexibility strategies at the multi-building scale, coordinated to not exceed existing infrastructure constraints at the pilot site. Results show that campus can provide 3-3.5 MW of potential load shed over a 4-hour event window through coordinated dispatch of thermal cooling load flexibility without exceeding existing infrastructure capacities. Under future high renewable scenarios, this thermal flexibility resource is also valuable when coordinated to reduce curtailment of intermittent renewables. Economic analyses were performed to effectively communicate various value propositions of grid-interactive and efficient building (GEB) thermal flexibility strategies. Load flexibility presents a financial value proposition to the campus today. By conducting rationalized, coordinated dispatch in response to real time price (RTP) fluctuations, the campus can benefit materially from daily price arbitrage. The RTP signal acts as an aggregating mechanism between the utility and customer to call on demand flexibility resources, with a large portion of the benefit deriving from a relatively small number of days. Realizing and maximizing this benefit with thermal load flexibility requires careful attention to the timing of pricing signals and parameterization of dispatch to overcome efficiency penalties. Grid value and signals are expected to evolve over time, and thermal load flexibility shows potential to adapt dispatch logic to support intermittent renewable generation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

End-Use Savings Shapes Measure Documentation: LED Lighting

Building on the successfully completed effort to calibrate and validate the U.S. Department of Energy's ResStock and ComStock models over the past three years, the objective of this work is to produce national data sets that empower analysts working for federal, state, utility, city, and manufacturer stakeholders to answer a broad range of analysis questions. The goal of this work is to develop energy efficiency, electrification, and demand flexibility end-use load shapes (electricity, gas, propane, or fuel oil) that cover a majority of the high-impact, market-ready (or nearly market-ready) measures. "Measures" refers to energy efficiency variables that can be applied to buildings during modeling. An end-use savings shape is the difference in energy consumption between a baseline building and a building with an energy efficiency, electrification, or demand flexibility measure applied. It results in a timeseries profile that is broken down by end use and fuel (electricity or on-site gas, propane, or fuel oil use) at each timestep. ComStock is a highly granular, bottom-up model that uses multiple data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual subhourly energy consumption of the commercial building stock across the United States. The baseline model intends to represent the U.S. commercial building stock as it existed in 2018. The methodology and results of the baseline model are discussed in the final technical report of the End-Use Load Profiles project. This documentation focuses on a single end-use savings shape measure - LED lighting. The LED lighting measure replaces interior lights with LEDs where applicable. The measure resulted in 1.25 TBtu energy savings across the building stock, with the majority of savings occurring in retail and warehouse buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

End-Use Savings Shapes Measure Documentation: Boiler Replacement with Air-Source Heat Pump Boiler and Natural Gas Boiler Backup

Building on the successfully completed effort to calibrate and validate the U.S. Department of Energy's ResStock (™) and ComStock (™) models over the past three years, the objective of this work is to produce national data sets that empower analysts working for federal, state, utility, city, and manufacturer stakeholders to answer a broad range of analysis questions. The goal of this work is to develop energy efficiency, electrification, and demand flexibility end-use load shapes (electricity, gas, propane, or fuel oil) that cover a majority of the high-impact, market-ready (or nearly market-ready) measures. "Measures" refers to energy efficiency variables that can be applied to buildings during modeling. An end-use savings shape is the difference in energy consumption between a baseline building and a building with an energy efficiency, electrification, or demand flexibility measure applied. It results in a time-series profile that is broken down by end use and fuel (electricity or on-site gas, propane, or fuel oil use) at each timestep. ComStock is a highly granular, bottom-up model that uses multiple data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual subhourly energy consumption of the commercial building stock across the United States. The baseline model intends to represent the U.S. commercial building stock as it existed in 2018. The methodology and results of the baseline model are discussed in the final technical report of the End-Use Load Profiles project. This documentation focuses on a single end-use savings shape measure - boiler replacement with air-source heat pump boiler with natural gas boiler backup. This measure replaces natural gas boilers for HVAC application by air-source heat pump boilers when applicable and use natural gas boiler backup when the heat pump boiler could not operate due to outdoor air conditions which are below its cutoff temperature. This measure helps to quantify the decarbonization as well as the energy savings potential from the replacement. The measure resulted higher savings in natural gas consumption compared to the increase in electricity consumption, with a ratio of 3. The total natural gas energy consumption was reduced by 41%, whereas the total electricity consumption was increased by 5.3%.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

End-Use Savings Shapes Measure Documentation: Boiler Replacement with Air-Source Heat Pump Boiler and Electric Boiler Backup

Building on the successfully completed effort to calibrate and validate the U.S. Department of Energy's ResStock TM and ComStock TM models over the past three years, the objective of this work is to produce national data sets that empower analysts working for federal, state, utility, city, and manufacturer stakeholders to answer a broad range of analysis questions. The goal of this work is to develop energy efficiency, electrification, and demand flexibility end-use load shapes (electricity, gas, propane, or fuel oil) that cover a majority of the high-impact, market-ready (or nearly market-ready) measures. "Measures" refers to energy efficiency variables that can be applied to buildings during modeling. An end-use savings shape is the difference in energy consumption between a baseline building and a building with an energy efficiency, electrification, or demand flexibility measure applied. It results in a time-series profile that is broken down by end use and fuel (electricity or on-site gas, propane, or fuel oil use) at each timestep. ComStock is a highly granular, bottom-up model that uses multiple data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual sub hourly energy consumption of the commercial building stock across the United States. The baseline model intends to represent the U.S. commercial building stock as it existed in 2018. The methodology and results of the baseline model are discussed in the final technical report of the End-Use Load Profiles project. This documentation focuses on a single end-use savings shape measure—boiler replacement by air-source heat pump boiler. This measure replaces space heating natural gas boilers by air-source heat pump boilers when applicable and helps quantify the decarbonization as well as the energy savings potential from the replacement. The measure resulted higher savings in natural gas consumption compared to the increase in electricity consumption, with a ratio of 2.9. The total natural gas energy consumption was reduced by 20%, whereas the total electricity consumption was increased by 2.5%.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A Cybersecurity Threat Profile for a Connected Lighting System

In anticipation of improved energy performance and cost savings, cities and building owners are increasingly considering “smart lighting initiatives” that aim to convert their collection of simple luminaires (i.e., lighting fixtures) into an intelligent connected lighting system (CLS) capable of remotely monitoring energy consumption and fault conditions, and possibly implementing adaptive lighting schemes. The U.S. Department of Energy (DOE) has set an national goal of tripling the energy efficiency and demand flexibility of the buildings sector by 2030, relative to 2020 levels 1. It is forecast that connected lighting systems can contribute to that goal by delivering 125 TWh of annual energy savings by 2035 2, equivalent to the annual output of 50 typical (500 MW) power plants. However, these energy savings and the DOE goal are put at significant risk if connected technologies are not adopted due to real or perceived cybersecurity concerns. Connected IoT devices such as these have historically been rife with vulnerabilities which sometimes put security considerations secondary to functionality and operability. What are the cybersecurity threats that will impact these systems, as formerly banal luminaires transition into intelligent connected devices that collect information about themselves, their surrounding environment, and possibly us? In this paper we analyze a threat profile performed on a fault-detection use case for streetlights. A threat profile establishes security requirements, justifies security measures, yields actionable controls, and effectively communicates risk to stakeholders. This effort provides critical information for making threat-based decisions to increase security at a reasonable cost, and can effectively be used by development teams, software architects, and managers to make cybersecurity a part of their ongoing culture of awareness, training, and prevention. This leads to more secure systems and better-understood security. On-premise, cloud, and hybrid architectures with different authentication mechanisms were modeled and later categorized using the Microsoft STRIDE framework. An analysis of the recommended controls for each threat was performed to determine which controls could and should be put in place by manufacturers or third-party suppliers, and which controls need to be left up the end-user to implement. Fifty-seven threats were identified. Among our key findings: (1) 65% (37/57) of the threats did not involve the luminaires, but rather the other components needed to communicate with and manage them; (2) 63% (36/57) of the threats could have been mitigated through manufacturer-implemented defensive techniques or “controls”; and (3) 23% (13/57) of the threats were dependent on the network configuration. Recommendations based on the results of this work are made to key stakeholder groups. Notably, lighting technology developers are advised to address all threats that can be reasonably controlled with baked-in technology solutions (e.g., encryption or authentication controls), and employ some form of secure supply chain management and tracking where other parts (e.g., sensors, microprocessors) of a luminaire must also be built and manufactured with the proper security controls in place. Developers should also review threats involving assets not developed in-house to understand how connectivity with other devices will affect their product during system operation and determine if a compensating control for a defense-in-depth strategy will be needed. Finally, those interested in deploying CLS should compare the differences between cloud and on-premise models to determine which is more suitable for their needs and the abilities of their security team.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

End-Use Savings Shapes Measure Documentation: Variable Refrigerant Flow with Heat Recovery and Dedicated Outdoor Air System

Building on the successfully completed effort to calibrate and validate the U.S. Department of Energy's ResStock™ and ComStock™ models over the past 3 years, the objective of this work is to produce national data sets that empower analysts working for federal, state, utility, city, and manufacturer stakeholders to answer a broad range of analysis questions. The goal of this work is to develop energy efficiency, electrification, and demand flexibility end-use load shapes (electricity, gas, propane, or fuel oil) that cover a majority of the high-impact, market-ready (or nearly market-ready) measures. "Measures" refers to energy efficiency variables that can be applied to buildings during modeling. An end-use savings shape is the difference in energy consumption between a baseline building and a building with an energy efficiency, electrification, or demand flexibility measure applied. It results in a time-series profile that is broken down by end use and fuel (electricity or on-site gas, propane, or fuel oil use) at each time step. ComStock is a highly granular, bottom-up model that uses multiple data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual subhourly energy consumption of the commercial building stock across the United States. The baseline model intends to represent the U.S. commercial building stock as it existed in 2018. The methodology and results of the baseline model are discussed in the final technical report of the End-Use Load Profiles project. This documentation focuses on a single heating, ventilation, and air-conditioning (HVAC) end-use savings shape measure - a variable refrigerant flow with heat recovery (VRF HR) heating and cooling system coupled with a dedicated outdoor air system (DOAS) for ventilation. This measure replaces existing multi-zone variable air volume (VAV) systems or single-zone rooftop units (RTU) with a VRF HR system coupled with a DOAS that includes an energy/heat recovery ventilator (E/HRV). The measure covers 53% of exisiting building stock's floor area and is not applicable to HVAC system types using district heating or cooling or buildings/spaces that include high-ventilation spaces such as kitchens where the amount of exhaust air is large. A DOAS with E/HRV is used to provide required outdoor ventilation air to spaces since ventilation air is generally not supplied by a VRF HR system. An exhaust air energy recovery ventilator (ERV ) with sensible and latent heat exchange is added to humid climate zones while a heat recovery ventilator (HRV ) with sensible only exchange is added to drier climate zones. The ERV is modeled as a fixed membrane plate counterflow heat exchanger, while the HRV is modeled as a sensible-only fixed aluminum plate counterflow heat exchanger. Both systems include a bypass (for temperature control and economizer lockout) and minimum exhaust temperature control for frost prevention.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

End-Use Savings Shapes Measure Documentation: Economizers

Building on the successfully completed effort to calibrate and validate the U.S. Department of Energy's ResStock™ and ComStock™ models over the past 3 years, the objective of this work is to produce national data sets that empower analysts working for federal, state, utility, city, and manufacturer stakeholders to answer a broad range of analysis questions. The goal of this work is to develop energy efficiency, electrification, and demand flexibility end-use load shapes (electricity, gas, propane, or fuel oil) that cover a majority of the high-impact, market-ready (or nearly market-ready) measures. "Measures" refers to energy efficiency variables that can be applied to buildings during modeling. An end-use savings shape is the difference in energy consumption between a baseline building and a building with an energy efficiency, electrification, or demand flexibility measure applied. It results in a time-series profile that is broken down by end use and fuel (electricity or on-site gas, propane, or fuel oil use) at each time step. ComStock is a highly granular, bottom-up model that uses multiple data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual subhourly energy consumption of the commercial building stock across the United States. The baseline model intends to represent the U.S. commercial building stock as it existed in 2018. The methodology and results of the baseline model are discussed in the final technical report of the End-Use Load Profiles project.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Intelligent Energy Optimizer for Residential Buildings

Demand-side management in the buildings is essential for meeting grid flexibility needs in a highly renewable energy scenario. Appliance load monitoring helps decision making for demand-side management by providing the information on operation status/power consumption from different appliances in the buildings. Nonintrusive load monitoring (NILM) is an attractive option for appliance load monitoring using because it has lower cost for sensors and helps mitigate privacy concerns. In this study, the team used an event detection technique followed by two different methods for event classification. The results from k-means clustering showed that the events from a single appliance are often distributed in multiple clusters. Thus, the unsupervised method of NILM using k-means clustering used in this study was not very suitable for load disaggregation. The results from NILM showed that the F1 score for event classification was 0.77 for a heat pump water heater and very low for other appliances using the rule-based classification.

24 POWER TRANSMISSION AND DISTRIBUTION↗

End-Use Savings Shapes Measure Documentation: Console Water-to-Air Geothermal Heat Pump

Executive Summary Building on the successfully completed effort to calibrate and validate the U.S. Department of Energy’s ResStock™ and ComStock™ models over the past several years, the objective of this work is to produce national datasets that empower analysts working for federal, state, utility, city, and manufacturer stakeholders to answer a broad range of analysis questions. The goal of this work is to develop energy efficiency, electrification, and demand flexibility end-use load shapes (electricity, gas, propane, or fuel oil) that cover most of the high-impact, market-ready (or nearly market-ready) measures. An end-use savings shape is the difference in energy consumption between a baseline building and a building with an energy efficiency, electrification, or demand flexibility measure applied. It results in a time series profile that is broken down by end use and fuel (electricity or on-site gas, propane, or fuel oil use) at each time step. ComStock is a highly granular, bottom-up model that uses multiple data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual sub-hourly energy consumption of the commercial building stock across the United States. The baseline model intends to represent the U.S. commercial building stock as it existed in 2018. This measure models the conversion of an existing heating, ventilating, and air-conditioning (HVAC) system to a series of “console” water-to-air heat pumps served by a ground heat exchanger. Console water-to-air geothermal heat pumps (GHP) are all-in-one packages that have no or minimal ductwork and serve individual spaces. Properly designed ground heat exchanger-coupled systems can offer benefits in energy efficiency relative to “conventional” HVAC systems, as well as facilitating beneficial electrification. Console GHPs can be coupled to a ground loop on the source side and can directly replace electric baseboard heaters or air-source packaged terminal heat pumps. Console GHPs can also bring in outdoor air for ventilation. This measure will be referred to throughout the document as the “Console GHP” upgrade.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

End-Use Savings Shapes Upgrade Package Documentation: Wall and Roof Insulation and New Windows

Building on the successfully completed effort to calibrate and validate the U.S. Department of Energy's ResStock and ComStock models over the past 3 years, the objective of this work is to produce national data sets that empower analysts working for federal, state, utility, city, and manufacturer stakeholders to answer a broad range of analysis questions. The goal of this work is to develop energy efficiency, electrification, and demand flexibility end-use load shapes (electricity, gas, propane, or fuel oil) that cover a majority of the high-impact, market-ready (or nearly market-ready) upgrade measures, or upgrades. "Measures" refers to energy efficiency variables that can be applied to buildings during modeling. An end-use savings shape is the difference in energy consumption between a baseline building and a building with an energy efficiency, electrification, or demand flexibility upgrade applied. It results in a time-series profile that is broken down by end use and fuel (electricity or on-site gas, propane, or fuel oil use) at each time step. ComStock is a highly granular, bottom-up model that uses multiple data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual subhourly energy consumption of the commercial building stock across the United States. The baseline model intends to represent the U.S. commercial building stock as it existed in 2018. The methodology and results of the baseline model are discussed in the final technical report of the End-Use Load Profiles project. This documentation focuses on an upgrade package of three end-use savings shapes upgrades - Window Replacement, Exterior Wall Insulation, and Roof Insulation, which we will refer to collectively as the "High Efficiency Envelope" package. More details on the individual upgrades can be found on the ComStock Measures Documentation page. An upgrade package applies two or more EUSS upgrades to a single building model simulation. Since ComStock is a bottom-up physics-based model, an upgrade package will go beyond aggregating or summing the individual upgrade results and produce novel results by simulating interactions between the upgrades. For example, pairing an envelope upgrade with an electrification upgrade would likely result in higher savings results than the sum of these upgrades individually, and the size of the heating, ventilating, and air conditioning (HVAC) equipment may be reduced if the envelope upgrade reduces the loads significantly.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

End-Use Savings Shapes Upgrade Package Documentation: LED Lighting, HP-RTU and ASHP-Boiler

Building on the successfully completed effort to calibrate and validate the U.S. Department of Energy's ResStock and ComStock models over the past 3 years, the objective of this work is to produce national data sets that empower analysts working for federal, state, utility, city, and manufacturer stakeholders to answer a broad range of analysis questions. The goal of this work is to develop energy efficiency, electrification, and demand flexibility end-use load shapes (electricity, gas, propane, or fuel oil) that cover a majority of the high-impact, market-ready (or nearly market-ready) upgrade measures, or upgrades. "Measures" refers to energy efficiency variables that can be applied to buildings during modeling. An end-use savings shape is the difference in energy consumption between a baseline building and a building with an energy efficiency, electrification, or demand flexibility upgrade applied. It results in a time-series profile that is broken down by end use and fuel (electricity or on-site gas, propane, or fuel oil use) at each time step. ComStock is a highly granular, bottom-up model that uses multiple data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual subhourly energy consumption of the commercial building stock across the United States. The baseline model intends to represent the U.S. commercial building stock as it existed in 2018. The methodology and results of the baseline model are discussed in the final technical report of the End-Use Load Profiles project. This documentation focuses on an upgrade package of three end-use savings shapes upgrades - Light Emitting Diode (LED) Lighting, Heat Pump Rooftop Unit (RTU) (HP-RTU), and Air-Source Heat Pump (ASHP) Boiler, which we will refer to collectively as the "Interior Lighting and Heat Pump" package. More details on the individual upgrades can be found on the ComStock Measures Documentation page. An upgrade package applies two or more EUSS upgrades to a single building model simulation. Since ComStock is a bottom-up physics-based model, an upgrade package will go beyond aggregating or summing the individual upgrade results and produce novel results by simulating interactions between the upgrades. For example, pairing an envelope upgrade with an electrification upgrade would likely result in higher savings results than the sum of these upgrades individually, and the size of the heating, ventilating, and air conditioning (HVAC) equipment may be reduced if the envelope upgrade reduces the loads significantly.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗