Learning-Based Demand Response in Grid Interactive Buildings via Gaussian Processes

This paper presents a predictive controller for a grid-interactive multi-zone building where the temperature dynamics are learned via Gaussian Process (GP) regression. We investigate the development of a learning-based predictive control with two main objectives: (i) continuously learn the temperature dynamics of the building based on data; and, (ii) use the learned dynamics to solve a multi-objective predictive control problem to guarantee occupants' comfort and energy efficiency during normal conditions and demand response events. We leverage the probabilistic non-parametric properties of GPs to estimate the (unknown) non-linear temperature dynamics of the building and to incorporate the uncertainty of those predictions in a multi-objective optimization problem. The GP-based predictive control is solved via a zero-order primal-dual projected-gradient algorithm. We evaluate numerically the performance of the proposed controller using a five-zone commercial building.

demand response↗

Empirical Modeling of Direct Expansion (DX) Cooling System for Multiple Research Use Cases

This study provides a general procedure to generate a direct expansion (DX) cooling coil system for a roof top unit (RTU), which is a typical heating ventilation and air-conditioning (HVAC) system for commercial buildings in the United States. Experimental data from a full-scale unoccupied 2-story commercial building is used for the HVAC modeling. The regression for identifying the model coefficients was carried out with multiple stages, and the results were validated with measured data. The model’s applicability was evaluated with multiple case studies, including a building energy simulation (BES) program validation, model-based predictive control (MPC), and fault diagnostics and detection (FDD).

42 ENGINEERING↗

A High-Granularity Approach to Modeling Energy Consumption and Savings Potential in the U.S. Residential Building Stock: Preprint

Building simulations are increasingly used in various applications related to energy efficient buildings. For individual buildings, applications include: design of new buildings, prediction of retrofit savings, ratings, performance path code compliance and qualification for incentives. Beyond individual building applications, larger scale applications (across the stock of buildings at various scales: national, regional and state) include: codes and standards development, utility program design, regional/state planning, and technology assessments. For these sorts of applications, a set of representative buildings are typically simulated to predict performance of the entire population of buildings. Focusing on the U.S. single-family residential building stock, this paper will describe how multiple data sources for building characteristics are combined into a highly-granular database that preserves the important interdependencies of the characteristics. We will present the sampling technique used to generate a representative set of thousands (up to hundreds of thousands) of building models. We will also present results of detailed calibrations against building stock consumption data.

building stock↗

Field Validation of a Building Operating System Platform

The U.S General Services Administration's (GSA's) Green Proving Ground program, in partnership with the National Renewable Energy Laboratory. completed a large pilot study of an Energy Management Information Systems (EMIS) with Automated System Optimization (ASO). Four test bed facilities, each with different building characteristics and systems, were chosen for the implementation of cloud-based EMIS with ASO. Depending on functionality, this tool can be extremely effective in energy management and energy optimization in buildings. The capabilities evaluated in the pilot ranged from energy savings and energy consumption predictions to evaluations of user acceptance, operability, and ease of installation. This report presents the methodology, lessons learned and best practices, and deployment recommendations for the GSA's portfolio of commercial office space, comprising more than 8,500 properties.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Preliminary Sensitivity Analysis for Sensors Impacts on Building Control Performance

This report describes the preliminary sensitivity analysis for sensor impacts on building control performance through the US Department of Energy’s Oak Ridge National Laboratory’s Flexible Research Platform (FRP-2) building. The rooftop unit system provides cooling and heating to the building. The main heating coil is a gas heating coil. Each zone is served by a variable air volume box with an electricity reheat coil. The rooftop unit and variable air volume box controls adopted the practical control sequences from ASHRAE Guideline 36-2018: High-Performance Sequences of Operation. For sensors, the incipient (time-changing) sensor errors, including bias sensor error and precision sensor error, are the inputs of interest. The outputs are energy consumption and thermal comfort (e.g., the predicted percentage of dissatisfied occupants). The large-scale simulation (3,600 cases) was conducted on a cloud platform by integrating sensor errors and ASHRAE Guideline 36 control sequences into an emulator based on the EnergyPlus simulation program with Python energy management system feature. The surrogate models were developed based on cloud simulation results. The uncertainty analysis showed that the sensor errors substantially affect building energy consumption and thermal comfort. The sensitivity analysis shows a ranking of sensor error impacts for each interested output item (e.g., cooling energy, reheat coil heating energy, predicted percentage of dissatisfied occupants). In FY 2022, sensor locations, types, and costs will be evaluated. The field test in Oak Ridge National Laboratory’s Flexible Research Platform building regarding sensor impacts will also be performed. Finally, a comparative analysis will be conducted based on the field test results and emulator results.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

SolarPlus Optimizer: Integrated Control of Solar, Batteries, and Flexible Loads for Small Commercial Buildings

Building-level microgrids may be a key strategy to unlock the combined potential of flexible loads, renewable generation, and energy storage. However, few software options exist for integrated control of building loads and other distributed energy resources at this scale. The commercial software solutions on the market can force customers to adopt one particular ecosystem of products, thus limiting consumer choice. The SolarPlus Optimizer (SPO) is an open-source building-level microgrid control platform that uses Model Predictive Control to optimize both building loads and behind-the-meter energy storage to reduce energy bills and increase demand flexibility. This paper evaluates the capabilities of SPO in a small commercial building in Northern California under multiple electricity tariffs and demand response scenarios. Comparing SPO operation with an emulated battery and baseline operation employing a commercial optimization service, SPO reduced electricity bills by an estimated 7.3% in summer, 3.2% in spring, and 3.7% in winter. In a “load shape” scenario meant to counter the “duck curve”, SPO achieved 71% fewer violations from the load signal than the baseline control method. During a three hour long load shed event, SPO reduced cooling and refrigeration load by 38%. This research shows significant potential to provide load flexibility for building-level microgrids for this type of control systems. Finally, the paper discusses the future direction of research on open-source control systems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Integrated Dynamic Facade Control with an Agent-based Architecture for Commercial Buildings

Dynamic façades have significant technical potential to minimize heating, cooling, and lighting energy use and peak electric demand in the perimeter zone of commercial buildings, but the performance of these systems is reliant on being able to balance complex trade-offs between solar control, daylight admission, comfort, and view over the life of the installation. As the context for controllable energy-efficiency technologies grows more complex with the increased use of intermittent renewable energy resources on the grid, it has become increasingly important to look ahead towards more advanced approaches to integrated systems control in order to achieve optimum life-cycle performance at a lower cost. This study examines the feasibility of a model predictive control system for low-cost autonomous dynamic façades. A system architecture designed around lightweight, simple agents is proposed. The architecture accommodates whole building and grid level demands through its modular, hierarchical approach. Automatically-generated models for computing window heat gains, daylight illuminance, and discomfort glare are described. The open source Modelica and JModelica software tools were used to determine the optimum state of control given inputs of window heat gains and lighting loads for a 24-hour optimization horizon. Penalty functions for glare and view/ daylight quality were implemented as constraints. The control system was tested on a low-power controller (1.4 GHz single core with 2 GB of RAM) to evaluate feasibility. The target platform is a low-cost ($35/unit) embedded controller with 1.2 GHz dual-core cpu and 1 GB of RAM. Configuration and commissioning of the curtainwall unit was designed to be largely plug and play with minimal inputs required by the manufacturer through a web-based user interface. An example application was used to demonstrate optimal control of a three-zone electrochromic window for a south-facing zone. The overall approach was deemed to be promising. Further engineering is required to enable scalable, turnkey solutions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Parallelized POD-based suboptimal economic model predictive control of a state-constrained Boussinesq approximation

Motivated by an energy efficient building application, we want to optimize a quadratic cost functional subject to the Boussinesq approximation of the Navier-Stokes equations and to bilateral state and control constraints. Since the computation of such an optimal solution is numerically costly, we design an efficient strategy to compute a sub-optimal (but applicationally acceptable) solution with significantly reduced computational effort. We employ an economic Model Predictive Control (MPC) strategy to obtain a feedback control. The MPC sub-problems are based on a linear-quadratic optimal control problem subjected to mixed control and state constraints and a convection-diffusion equation, reduced with proper orthogonal decomposition. Finally, to solve each sub-problem, we apply a primal-dual active set strategy. The method can be fully parallelized, which enables the solution of large problems with real-world parameters.

97 MATHEMATICS AND COMPUTING↗

State-of-the-art on research and applications of machine learning in the building life cycle

Fueled by big data, powerful and affordable computing resources, and advanced algorithms, machine learning has been explored and applied to buildings research for the past decades and has demonstrated its potential to enhance building performance. This study systematically surveyed how machine learning has been applied at different stages of building life cycle. By conducting a literature search on the Web of Knowledge platform, we found 9579 papers in this field and selected 153 papers for an in-depth review. The number of published papers is increasing year by year, with a focus on building design, operation, and control. However, no study was found using machine learning in building commissioning. There are successful pilot studies on fault detection and diagnosis of HVAC equipment and systems, load prediction, energy baseline estimate, load shape clustering, occupancy prediction, and learning occupant behaviors and energy use patterns. None of the existing studies were adopted broadly by the building industry, due to common challenges including (1) lack of large scale labeled data to train and validate the model, (2) lack of model transferability, which limits a model trained with one data-rich building to be used in another building with limited data, (3) lack of strong justification of costs and benefits of deploying machine learning, and (4) the performance might not be reliable and robust for the stated goals, as the method might work for some buildings but could not be generalized to others. Finally, findings from the study can inform future machine learning research to improve occupant comfort, energy efficiency, demand flexibility, and resilience of buildings, as well as to inspire young researchers in the field to explore multidisciplinary approaches that integrate building science, computing science, data science, and social science.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Investigating the effects of local environment on nitrogen vacancies in high-entropy metal nitrides

High-entropy metal nitrides are an important material class in a variety of applications, and the role of nitrogen vacancies is of great importance for understanding their stability and mechanical properties. Here, we study six different high-entropy nitrides with eight different metal species to build a predictive model of the nitrogen-vacancy formation energy. We construct sets of supercells that maximize the number of unique nitrogen environments for a given chemistry, and then use density-functional theory to calculate the energy density for all nitrogen sites, and the vacancy formation energies for the highest, lowest, and a median subset based on the energy densities. The energy density of nitrogen sites correlates with the vacancy formation energies, for binary, ternary, and high-entropy nitrides. A linear regression model predicts the vacancy formation energies using only the nearest-neighbor composition; across our eight metals, we find the largest vacancy formation energies next to Hf, then Zr, Ti, V, Cr, Ta, Nb, and the lowest near Mo. Additionally, we see that binary nitride data show qualitatively similar vacancy formation energy trends for high-entropy nitrides; however, the binary data alone are insufficient to predict the complex nitride behavior. Our model is both predictive and easily interpretable, and correlates with experimental data.

DeSilva, Charith R. [Univ. of Illinois at Urbana-C↗

Data-Driven Modeling and Optimization of Building Energy Consumption: a Case Study

Installing sensors and Building Automation Systems (BAS) allows controlling the facility operations while generating data that can be analyzed for model development. This work focuses on data-driven modeling of the building to optimize energy consumption. The City of Orlando aims to reduce its energy consumption so, they provided us access to their BAS for data and studying the operation of its facilities. We selected a mid-size pilot building to conduct data analysis and modeling. We develop an Application Programming Interface (API) to login to the servers and scrape data. The scraped data contains features ranging from environmental conditions to equipment activity. This dataset is a time series so, it's handled in accordance and analyzed to investigate patterns and relations between data points that help choose parameters for predictive models for building and equipment. Finally, the models are optimized to reduce the energy consumption of the facility.

Grover, Divas↗

PANDEMIC: Occupancy driven predictive ventilation control to minimize energy consumption and infection risk

During the SARS-CoV-2 (COVID-19) pandemic, governments around the world have formulated policies requiring ventilation systems to operate at a higher outdoor fresh air flow rate for a sufficient time, which has led to a sharp increase in building energy consumption. Therefore, it is necessary to identify an energy-efficient ventilation strategy to reduce the risk of infection. In this study, we developed an occupant-number-based model predictive control (OBMPC) algorithm for building ventilation systems. First, we collected the occupancy and Heating, ventilation, and air conditioning system (HVAC) data from March to July 2021. Then, four different models (Auto regression moving average-based multilayer perceptron (ARMA_MLP), Recurrent neural networks (RNN), Long short-term memory networks (LSTM), and Nonhomogeneous Markov with change points detection (NH_Markov)) were used to predict the number of room occupants from 15 min to 24 h ahead with an interval output. We found that each model could predict the number of occupants with 85% accuracy using a one-person offset. Furthermore, the accuracy of 15 min of the ahead prediction could reach 95% with a one-person offset, but none of them could track abrupt changes. The occupancy prediction results were used to calculate the ventilation demand using the Wells-Riley equation, and the upper bound can maintain an infection risk lower than 2% for 93% of the day. This OBMPC model could reduce the coil load by 52.44% and shift the peak load by 3 h up to 5 kW compared with 24 × 7 h full outdoor air (OA) system when people wear masks in the space. The occupancy prediction uncertainty could cause a 9% to 26% difference in demand ventilation, a 0.3°C to 2.4°C difference in zone temperature, a 28.5% to 44.5% difference in outdoor airflow rate, and a 10.7% to 28.2% difference in coil load.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

An approach for fast and accurate simulation of phase change material based thermal energy storage in buildings

Latent heat thermal energy storage (LHTES) has significant potential for mitigating peak electricity demand and enabling load shifting in buildings. Phase Change Material embedded heat exchangers (PCM-HX) can significantly improve energy demand management due to high storage capacity. However, PCM-HX evaluation typically depends on computationally expensive fully transient simulations, posing significant challenges for scalable system- and building-level energy assessments across different climates and system architectures. This paper presents a generalized, accurate, and computationally efficient methodology for simulating building energy systems integrated with LHTES. The PCM-HX transient performance is represented by performance maps generated using a Generalized Resistance-Capacitance Model (GRCM) that enables accurate predictions of arbitrary PCM-HXs at low computational cost. The feasibility of the proposed approach was verified using a case study considering a dual-mode heat pump-thermal energy storage (HP-TES) system simulated in Modelica with Spawn of EnergyPlus™ for a DOE prototype small office building in two locations: Tampa, FL, and International Falls, MN. The PCM-HX performance maps provided accurate predictions of PCM-HX transient behavior, with mean absolute percentage deviations within 2–4% compared to GRCM while also achieving at least 1800× reduction in computational time. Moreover, the HP-TES system achieved energy savings of up to 17.4% in Tampa, FL, and 62.2% in International Falls, MN, demonstrating the broader applicability of the proposed methodology across different climate zones. This work highlights the importance of robust PCM-HX models in enabling accurate and computationally efficient building-level simulations and enabling future research opportunities for investigating optimized HP-TES designs and advanced control strategies for grid-interactive buildings.

Modelica↗

Home energy management under realistic and uncertain conditions: A comparison of heuristic, deterministic, and stochastic control methods

We report home energy management systems (HEMS) have been shown to reduce energy bills and to provide grid services including peak demand reduction and demand flexibility. However, uncertainty in residential energy systems is a significant issue and can reduce the benefits of a HEMS to the homeowner or grid operator. Sources of uncertainty include weather forecasts, predictions of energy-related occupant activities (e.g., hot water draws), and parameter estimation for the building envelope and energy-consuming equipment. This paper tackles the problem of uncertainty by developing a framework that simulates HEMS in uncertain conditions and evaluates the performance of multiple control strategies. A linear, reduced-order residential building model for model predictive control applications is derived and compared to a full-order model. Stochastic model predictive control is shown to perform better than deterministic and heuristic methods when considering realistic forecasts with uncertainty. The framework can evaluate the performance of HEMS in real-world applications, which can help de-risk HEMS deployment.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Surrogate model evaluation and building energy benchmarking for commercial buildings

Building energy consumption benchmarking involves challenges associated with various energy patterns for different building types; heating, ventilating, and air-conditioning (HVAC) system types; and climates. Given significant variation in energy use patterns, accurate prediction of long-term energy use using surrogate models remains challenging. Multiple linear regression (MLR) is commonly used for building energy benchmarking because of its simple structure; however, it lacks accuracy compared to other black-box models. Although many studies have compared surrogate models and offer guidance on model selection based on metrics, they do not provide detailed analysis on improving the surrogate model accuracy. In this paper, we implement a surrogate model using polynomial ridge regression (i.e., MLR with interaction terms combined with ridge regularization) for small office and retail strip mall buildings across six HVAC system types and all climate zones, for electricity and natural gas in baseline and proposed scenarios. A simulation workflow is developed using OpenStudio TM /EnergyPlus TM to generate simulation data using measures over a wide range of efficiency inputs. Enhancements based on statistical insights are used for improving the model accuracy using filters, input transformations, and change points. Surrogate models achieved average coefficient of variation of the root mean squared error (CVRMSE) values of 2.17, 1.06, 2.05, and 3.26 for proposed electricity, proposed natural gas, baseline electricity, and baseline natural gas, respectively, with enhancements reducing CVRMSE by an average of 14.9% across all combinations. We provide model interpretation via Shapley additive explanations to determine which input variables most influence energy consumption and provide supportive arguments for enhancements.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Deep-Learning-Based Multi-Timescale Load Forecasting in Buildings: Opportunities and Challenges from Research to Deployment

Electricity load forecasting for buildings and campuses is becoming increasingly important as the penetration of distributed energy resources (DERs) grows. Efficient operation and dispatch of DERs require reasonably accurate predictions of future energy consumption in order to conduct near-real-time optimized dispatch of on-site generation and storage assets. Electric utilities have traditionally performed load forecasting for load pockets spanning large geographic areas, and therefore, forecasting has not been a common practice by buildings and campus operators. Given the growing trends of research and prototyping in the grid-interactive efficient buildings domain, characteristics beyond simple algorithm forecast accuracy are important in determining the algorithm's true utility for smart buildings. Other characteristics include the overall design of the deployed architecture and the operational efficiency of the forecasting system. In this work, we present a deep-learning-based load forecasting system that predicts the building load at 1-hour intervals for 18 hours in the future. We also discuss challenges associated with the real-time deployment of such systems as well as the research opportunities presented by a fully functional forecasting system that has been developed within the National Renewable Energy Laboratory's Intelligent Campus program.

building load forecasting↗

Control of Behind-the-Meter Resources for Enhancing the Resilience of Residential Buildings

There is increased concern about the impacts of frequent power outages, caused primarily by extreme weather conditions. With increasing behind-the-meter resources such as solar photovoltaics (PV), battery energy storage, and controllable loads, these resources - if properly coordinated - can meet critical loads even during an outage. Resilience building controls can coordinate and operate these resources to enhance the resiliency of buildings supporting critical loads for longer duration. In this paper, we present two resilience building controls: rule-based control and model predictive control (MPC). We simulated various scenarios considering different locations, seasons, outage types, and times of outages to evaluate the performance of resilience controls. The results show that MPC-based control can enhance resilience up to 65% compared to rule-based control. Similarly, PV self-consumption and occupant thermal comfort both increase during outages with MPC-based control.

ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION↗