Search NASA⌕ Search

SEARCH · Search NASA

Results for “Building heights”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Independent Review of Siesmic Performance Assessments for the Plutonium Facility PF-4

The Plutonium Facility, designated PF-4, is located in Technical Area 55 at the Los Alamos National Laboratory (LANL). The facility is a one-story rectangular structure above a complete basement; the building was constructed of cast-in-place reinforced concrete, with small interior frames of structural steel. The plan dimensions of the building are 265’×284’. The overall height of the building varies between 39’-0” at the north and south ends, and 40’-6” at the center ridge. The programmatic work performed in the building is vital to our national security and its functions and storage purposes are not replicated elsewhere in the United States Department of Energy (DOE).

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Design of toroidal transformers for maximum efficiency

The design of the most efficient toroidal transformer that can be built given the frequency, volt-ampere rating, magnetic flux density, window fill factor, and materials is described. With the above all held constant and only the dimensions of the magnetic core varied, the most efficient design occurs when the copper losses equal 60 percent of the iron losses. When this criterion is followed, efficiency is only slightly dependent on design frequency and fill factor. The ratios of inside diameter to outside diameter and height to build of the magnetic core that result in transformers of maximum efficiency are computed.

Dayton, J. A., Jr.↗

Corridor Design and Analysis for UAM Operations

The Urban Air Mobility (UAM) concept is a part of Advanced Air Mobility (AAM), a joint initiative between the Federal Aviation Administration (FAA), NASA, and industry to develop an air transportation system that uses new electric (i.e., green) air vehicles in geographical areas previously underserved by traditional aviation. Market forecast studies predict that there will be demand for alternate modes of air transportation using electric Vertical Take-off and Landing aircraft. UAM expands transportation networks by introducing short flights to move people and goods around metropolitan areas​. UAM is expected to improve mobility for the public, decongest road traffic, reduce trip time, and decrease strain on existing public transportation networks. Various challenges exist to make the introduction of UAM operations successful in the U.S. National Airspace System (NAS). These include but are not limited to integration with existing airports and airspace, provision of air traffic services (e.g., separation), vehicle design and certification, and community acceptance. The focus of this paper is on integration of UAM operations into the NAS via introduction of new airspace structures. UAM will operate within a regulatory, operational, and technical environment that is incorporated into the NAS​. As per the UAM Concept of Operations (ConOps), the FAA retains regulatory authority and is responsible for establishing operational parameters and maintaining oversight. The FAA’s UAM ConOps describes flights at low altitudes (below 5,000 ft) with minimal disruption to established conventional aircraft traffic and limited voice interactions with the Air Traffic Control (ATC). Early stages of UAM may use existing procedures to safely integrate UAM with conventional flights. This would involve flying under Part 91 Visual Flight Rules (VFR) and using voice for communications. The initial UAM ecosystem will utilize the current infrastructure such as routes, helipads, and ATC services, where practicable. ​A NASA study explored the use of existing helicopter routes in Dallas Fort Worth (DFW) airspace for initial UAM operations with a Letter of Agreement (LOA) that included procedures to request a Class B (controlled airspace) clearance. The research showed that the chosen approach was feasible for near-term, low-demand UAM traffic, but was not scalable. The growth of operations in today’s aviation system has resulted in airspace reorganization and procedures to ensure safety and efficiency as traffic rates increase. One proposed operating innovation that can help with the scalability of UAM is establishing routes and corridors. This may look similar to the Area Navigation (RNAV) procedures used today to streamline operations into busy airports. However, instead of FAA automation systems and ATC managing the flow of traffic, some UAM concepts envision a third-party service provider performing this role as part of the Provider of Services for UAM (PSU) network. The FAA’s UAM ConOps posits that new airspace structures such as UAM corridors include the following design criteria: 1) Minimal impact on existing NAS operations, 2) no or minimal additional ATC services, 3) public interest considerations such as noise, safety, and security, and 4) customer needs. The airspace available in urban environments is limited by the height of buildings, the effect of weather including wind gusts, privacy needs, and a clearance envelope. The new airspace structure would need to be designed around large airports and urban areas where the initial market demand is likely to exist. NASA has started evaluating airspace in the Dallas Fort Worth area to design new airspace structures, keeping the first two design criteria in mind. It is assumed that there will be an on-board pilot-in-command, and the flights will operate under VFR in Visual Meteorological Conditions. Corridors will be required in controlled airspace, whereas UAM operations can fly in uncontrolled Class G and E airspace using current day rules. Keeler et. al identified factors and heuristics for development of routes for UAM operations for integration with airspace close to large airports such as Dallas Fort Worth and Dallas Love Field. This paper describes the heuristics applied to define the corridors, analyzes them with respect to legacy traffic and presents key results.

Urban Air Mobility↗

NATURF

The Neighborhood Adaptive Tissues for Urban Resilience Futures tool (NATURF) is a Python workflow that generates les readable by the Weather Research and Forecasting (WRF) model. The NATURF Python modules use shapefiles containing building footprint and height data as input to calculate 132 building parameters at any resolution and converts the parameters into a binary file format.

Allen-Dumas, MelissaRee [Oak Ridge National Lab. (↗

Capacity Building Engagement for Estimating Forest Stand Height Utilizing the SAR Handbook

Utilizing Synthetic Aperture Radar (SAR) which provides information such as vegetation structure and moisture content, independently of weather conditions is a powerful tool that can be employed to more effectively monitor deforestation and estimate biomass which is of paramount concern, especially in South and Southeast Asia which contain nearly 15% of all tropical forests. SERVIR, a NASA-USAID initiative, works in partnership with regional hubs around the world building capacity through promoting the use of Earth observations and geospatial technologies. The SERVIR Global network and the Silva Carbon program collaboratively developed the SAR Handbook: Comprehensive Methodologies for Forest Monitoring and Biomass Estimation which set out to reduce the barriers associated with leveraging SAR and increase the capacity of researchers and practitioners globally to use SAR for monitoring. In particular, utilizing SAR to estimate Forest Stand Height (FSH) is crucial for greenhouse gas emissions reporting and estimating carbon storage. Programs such as Reducing Emissions from Deforestation and Forest Degradation (REDD) rely on parameters such as these for their monitoring efforts. This talk will showcase the collaborative efforts, emergent geospatial technology leveraged, and capacity building approaches utilized by our team to conduct a South and Southeast Asia focused in-person training event located at SERVIR-Mekong, a SERVIR hub lead by the Asian Disaster Preparedness Center (ADPC) in Bangkok.

AGU↗

A machine learning method of modern urban building energy modeling: A case study of Chicago

Urban-scale building energy modeling is vital for urban planning. However, it can be challenging to assimilate reliable non-geometry building data for urban-scale modeling without extensive investment. Here, this study introduces a novel approach to developing modern urban-scale building energy stock data using geographic information systems and machine learning algorithms without necessarily requiring pre-supplied non-geometric metadata. The proposed framework integrates building footprint and height data to estimate gross floor areas, and matches each building to a pool of candidate records from ComStock or ResStock—filtered to the same county and ranked by geometric similarity—demonstrate a proof-of-concept case study in Chicago for predicting energy use intensity (EUI) using scalable datasets. The model achieved a mean bias error (MBE) of 0.08 kWh/m² and root mean square error (RMSE) of 14.84 kWh/m² under full metadata input for EUI prediction. With only location inputs, the model captured 69.2 % of EUI within predicted ranges. These results demonstrate the model’s potential to support early-stage urban planning, identify candidates for energy-efficient retrofits. By removing the dependency on detailed pre-surveys or extensive building metadata, the approach overcomes a key barrier in traditional urban-scale building energy modeling, illustrating a pathway toward broader and more cost-effective application, though further multi-city validation and improved treatment of pre-1925 buildings are needed.

Energy Use Intensity↗

Precipitation Meteorological Instruments (PRECIPMET) Handbook

The PRECIPMET surface meteorology instrument system provides temperature, relative humidity, pressure, wind speed and direction, and precipitation data relevant to the precipitation network instruments: laser disdrometer (PARS2) and radar wind profiler (RWP). The PRECIPMET is installed at the intermediate facilities (IF) of the U.S. Department of Energy (DOE)’s Atmospheric Radiation Measurement (ARM) Southern Great Plains (SGP) atmospheric observatory. The instrument system consists of a Vaisala WXT520 weather transmitter and a 12”-diameter Novalynx tipping bucket rain gauge (TBRG). The WXT520 is mounted on top of the control building at a height of approximately 4 meters. The tipping bucket is mounted on a pole level with the surrounding fencing (approximately 2 meters) to prevent physical interference with the gauge.

54 ENVIRONMENTAL SCIENCES↗

Vertical meteorological patterns and their impact on the energy demand of tall buildings

In accordance with the developing economy and growing population, an increasing number of tall buildings have been constructed over the last 20 years. In 2017, there were 144 new buildings worldwide that were 200 m or greater in height; 50% of these buildings were in China. Due to the vertical gradient impact of meteorological parameters, the energy performance of tall buildings differs from that of general buildings. Few studies exist on vertical meteorological changes using measured data at different heights. Most studies on dynamic energy simulation simulate meteorological parameters using models. This study explores vertical meteorological patterns using hourly dry-bulb temperature, relative humidity, and wind speed data from 2007 to 2017 for a 325 m meteorological tower in Beijing. The temperature decreased significantly with increasing altitude (~0.9 °C per 100 m), while the daily temperature difference decreased with increasing altitude. The absolute humidity did not change significantly with height. The wind speed increased with altitude at approximately 2 m/s per 100 m. The building simulation showed that the annual heating load at a height of 320 m increased by 85% from that at 8 m; the annual cooling load decreased by 20%. Such significant differences in thermal loads for 300-m-tall buildings confirm the need to consider vertical meteorological differences in building performance simulations for tall buildings. A greater number of measurement points at different heights improve the simulation accuracy. Finally, guidance on selecting the heights for vertical metrological measurements is provided based on the influences of building thermal loads.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Conceptual optimization using genetic algorithms for tube in tube structures

The purpose of this article is to optimize the tube in tube structural systems for tall buildings under the horizontal wind loads. It is well-known that the horizontal wind loads is the main criteria when choosing the structural system, the types and the dimensions of structural elements in the majority of tall buildings. Thus, the structural response of tall buildings under the horizontal wind loads will be analyzed for 40 story buildings and a total height of 120 meters; the horizontal dimensions will be 30m × 30m for the first two optimization problems and 15m × 15m for the third. The optimization problems will have the following as objective function the cross section area, as restrictions the displacement of the building< the admissible displacement (H/500), and as variables the cross section dimensions of the structural elements.

42 ENGINEERING↗

The impact of earthquakes on the city of Aigio in Greece. Urban planning as a factor in mitigating seismic damage

This paper examines the effects of the mortal earthquake on the city of Aigio in Greece in 1995, with particular focus on urbanization and planning policies. It is based on interviews with experts and surveys on damage to buildings following this earthquake. The analysis takes into account several factors, such as exact location, land use, construction period and the height of damaged buildings. Furthermore, the relationship between the seismic damage and the postseismic construction development of Aigio is examined and the conclusion is reached that the Greek urban planning system needs to be better organized to prepare for seismic damage. To this end, the paper recommends a five-point discussion agenda for applying local planning to seismic mitigation.

58 GEOSCIENCES↗

Comparison of analytical methods for calculation of wind loads

The following analysis is a comparison of analytical methods for calculation of wind load pressures. The analytical methods specified in ASCE Paper No. 3269, ANSI A58.1-1982, the Standard Building Code, and the Uniform Building Code were analyzed using various hurricane speeds to determine the differences in the calculated results. The winds used for the analysis ranged from 100 mph to 125 mph and applied inland from the shoreline of a large open body of water (i.e., an enormous lake or the ocean) a distance of 1500 feet or ten times the height of the building or structure considered. For a building or structure less than or equal to 250 feet in height acted upon by a wind greater than or equal to 115 mph, it was determined that the method specified in ANSI A58.1-1982 calculates a larger wind load pressure than the other methods. For a building or structure between 250 feet and 500 feet tall acted upon by a wind rangind from 100 mph to 110 mph, there is no clear choice of which method to use; for these cases, factors that must be considered are the steady-state or peak wind velocity, the geographic location, the distance from a large open body of water, and the expected design life and its risk factor.

Minderman, Donald J.↗

Dose rate profile surrounding a repository

The focus of this research was to analyze the dose rate profile around a waste repository using Monte Carlo techniques. Dose rates at various heights and distances were analyzed outside of the waste repository using MCNPX [1]. The heights measured extended the height of the building and the distances varied between 0 and 22 m away from the waste repository. The simulation data were fitted by smooth analytical functions for different height levels and distances, such that vertical and horizontal dose rates as functions of source-detector distance were achieved. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Potential Demand Reduction from Buildings in a Simulated Utility

The availability of large-area sensing, scalable algorithms, and high-performance computing has enabled the possibility of urban-scale building energy modeling using new methods not limited to the scalability of manual building energy model creation or retrieval of county-by-county tax assessor’s data. Automatic Building detection and Energy Model creation (AutoBEM) has created 178,368 building energy models for the Electric Power Board (EPB) of Chattanooga, TN, and compared simulation performance to 15-minute data from each building. These models leverage several data sources (e.g. imagery, GIS, utility), software tools to extract building properties (e.g. footprint, height, façade type, window-to-wall ratio, occupancy, building type), simulate at scale on two of the world’s #1 fastest supercomputers, and provide web-based visual analytics.Grid-interactive efficient buildings offer the potential to reduce utility and rate-payer energy costs during each calendar month’s hour of critical generation – when the least efficient, most costly, and often dirtiest generation assets must be brought online. In this paper, EnergyPlus is used to simulate over 150,000 buildings to assess the technical potential of utility-controlled smart thermostats. This is analyzed under a couple scenarios leveraging buildings as thermal batteries via pre-conditioning to coast through peak hours. Results are provided in box and whisker plots assessing the distribution of peak demand reduction at the utility-scale along with breakouts of energy and demand savings by building type and vintage.

Bass, Brett↗

Experimental Study on the Porosity of Electron Beam Melting-Manufactured Ti6Al4V

Electron beam melting (EBM) is one of the powder bed fusion technologies, which utilizes a high-energy electron beam, as a moving heat source, in order to melt (by rapid self-cooling) metal powder and produce parts in a layer-building fashion. Anyway, many technical aspects concerning the quality of EBM-produced components are still industrial open items and studies need to be carried out. In accordance with the industrial needs, in this work researchers have studied the influence of two process parameters, i.e., samples orientation and height in the build chamber. The experiments have consisted in rectangular parallelepiped (50 × 10 × 10 mm) samples Ti6Al4V produced by EBM following a two-factor DOE. A tomographic investigation of all the samples produced by EBM has been carried out in order to get a complete set of data on porosity defects that have been analyzed showing the influence of process parameters on the porosity generation and pointing out typical features of defect distributions. The results obtained from this work have given precious information to designers and EBM technologists in order to: optimize the components’ design and the building setup obtaining a manufacturing process with the minimal level of porosity defects (best growth orientation). provide information for mechanical post-processing (metal removal).

36 MATERIALS SCIENCE↗

Building Toxic Metal Characterization and Decontamination Report: Area 6, Building 914

The purpose of this report is to outline the toxic metal characterization and decontamination efforts in Area 6, Building 914. This includes the initial building inspection, the hotspot sampling, results/findings, building cleanup, and the verification sampling. Building 914 is a steel light frame building that was constructed in 1992. It is about 16,454 square feet, and five employees are assigned to this building. According to the building's floor plan blueprints, it could be inferred that this building was once a Wiremen/Lineman shop. In 2002-2004, the National Nuclear Security Administration Nevada Site Office embarked on a broad characterization of beryllium (Be) surface concentrations throughout the North Las Vegas Facility, the Nevada National Security Site (NNSS), and ancillary facilities like the Special Technologies Laboratory, Remote Sensing Laboratory, etc. Building 914 was part of this characterization. The results of the 2002 study illustrated that the metal housekeeping limits were within acceptable limits and from a Be standpoint, the building was determined to be fit for occupancy. On March 2, 2011, based on a request from Building 914 users, National Security Technologies, LLC (NSTec) Industrial Hygiene (IH) collected bulk samples from the southwest corner of Building 914 at heights above 6 feet where black dust had been noticed on this particular wall. IH conducted surface swipe sampling of the area and analyzed the samples for toxic metals, namely, beryllium (Be), cadmium (Cd), chromium (Cr), lead (Pb), and manganese (Mn). The sample results indicated values two to four times above the housekeeping threshold for Be, Cd, Cr, Pb, and Mn. Subsequently, the facility was closed and posted; the necessary personnel were notified; and controls were instituted for ingress and egress of the building. On March 17, 2011, IH performed an extensive sampling event involving the entire warehouse in accordance with NSTec Organization Procedure OP-P250.004, Sampling Procedures. Analysis of the results from this exercise illustrated that toxic metal contamination was ubiquitous throughout the warehouse section of this building but did not extend into the office, restroom, and break room areas. On March 22, 2011, a planning meeting was held with Environment, Safety, Health & Quality management; Operations & Infrastructure (O&I) mangement; Facility Management; Occupational Medicine; O&I Operations; and IH. After a brief discussion concerning the salient facts of the surface sample results, it was agreed that the facility and its contents required cleaning. The facility would then be re-sampled to verify cleanliness and suitability for re-occupancy. On April 18, 2011, warehouse cleanup activites began. On July 5, 2011, upon receipt of the results from the last cleaned section, the cleanup operations were concluded. The building was statistically determined to be clean; thus, it could be reoccupied and the warehouse operations could resume immediately.

54 ENVIRONMENTAL SCIENCES↗

Non Linear Step By Step Seismic Response and the Push Over Analysis Comparison of a Reinforced Concrete of Ductile Frames 25 Level Building

Based on a ductile frames 25 level building, a non-linear analysis with increased monotonically lateral loads (Push-Over) was made in order to determine its collapse and its principal responses were compared against the time-history seismic responses determined with the SCT-EW-85 record. The seismic-resistance design and faced to gravitational loads was made according to the Complementary Technical Norms of Concrete Structures Design (NTC-Concrete) and the NTC-Seismic of the Mexico City Code (RDF-04), satisfying the limit service states (relative lateral displacement between story height maximum relations, story drifts {<=}0.012) and failure (seismic behavior factor, Q = 3). The compressible (soft) seismic zone III{sub b} and the office use type (group B) were considered. The non-lineal responses were determined with nominal and over-resistance effects. The comparison were made with base shear force-roof lateral displacement relations, global distribution of plastic hinges, failure mechanics tendency, lateral displacements and story drift and its distribution along the height of the building, local and global ductility demands, etc. For the non-linear static analysis with increased monotonically lateral loads, was important to select the type of lateral forces distribution.

58 GEOSCIENCES↗

naturf: a package for generating urban parameters for numerical weather modeling

The Neighborhood Adaptive Tissues for Urban Resilience Futures tool (NATURF) is a Python workflow that generates files readable by the Weather Research and Forecasting (WRF) model. NATURF uses geopandas and hamilton to calculate 132 building parameters from shapefiles with building footprint and height information. These parameters can be collected and used in many formats, and the primary output is a binary file configured for input to WRF. This workflow is a flexible adaptation of the National/World Urban Database and Access Portal Tool (NUDAPT/WUDAPT) that can be used with any study area at any spatial resolution. The climate modeling community and urban planners can identify the effects of building/neighborhood morphology on the microclimate using the urban parameters and WRF-readable files produced by NATURF. More information on the urban parameters calculated can be found in the documentation.

54 ENVIRONMENTAL SCIENCES↗

Building morphologies of the USA structures database; a gauntlet feature set

In recent years there has been a proliferation of methods and data to extract building footprints from satellite imagery. However there has been very little effort to provide additional insight about these buildings beyond their spatial location and shape. Features derived from their geometries can be used to better characterize these buildings which are critical for further research and development. In this work a set of 65 unique features for every building for more than 131 million buildings covering the US has been developed. This rich feature dataset will enable researchers, policymakers and various agencies to derive additional building characteristics like height, occupancy type, and help to gain valuable and new insights of the built environment.

Environmental sciences↗