Creation of a Weather Drivers Test Suite for Inclusion in ASHRAE Standard 140

Weather conditions are an important boundary condition for building performance simulation (BPS) calculations. For existing test cases in ASHRAE Standard 140 "Method of Test for Evaluating Building Performance Simulation Software" (ANSI/ASHRAE 2020), it was assumed that the software being tested could adequately read and interpret the weather data in the provided standard weather files. As differences between the programs have been reduced and as more programs have shifted to sub-hourly time steps this assumption has become more stretched. To address these concerns a new test suite testing a program's ability to read and interpret the data from a standard weather file was developed. The purpose of the test suite is to test the use of the typical data used from standard weather files.

54 ENVIRONMENTAL SCIENCES

A Cryogenic Fluid System Simulation in Support of Integrated Systems Health Management

Simulations serve as important tools throughout the design and operation of engineering systems. In the context of sys-tems health management, simulations serve many uses. For one, the underlying physical models can be used by model-based health management tools to develop diagnostic and prognostic models. These simulations should incorporate both nominal and faulty behavior with the ability to inject various faults into the system. Such simulations can there-fore be used for operator training, for both nominal and faulty situations, as well as for developing and prototyping health management algorithms. In this paper, we describe a methodology for building such simulations. We discuss the design decisions and tools used to build a simulation of a cryogenic fluid test bed, and how it serves as a core technology for systems health management development and maturation.

cryogenics

CAD-based Energy & Cost Models Prove Affordable Net Zero Energy Performance for WonderWindows + 24" On-center Framing

Windows are thermally the “weakest link” in the building envelope. Increasing the thermal resistance of windows can make buildings more energy efficient and reduce the cost of electricity needed for conditioning the building. The proper design and placement of framing can also help to reduce the thermal bridging that occurs near the window frame area. This study investigates the energy performance of multi-pane acrylic windows fitting 24" on-center framing. Initial parametric analysis is done for a single zone accessory dwelling unit (ADU). Then, an energy model was developed for three types of wood-framed buildings: townhomes, stacked flats and hotels. A whole building energy simulation is performed for each of these building types in hot-humid Houston, mixed-humid New York, and cold-humid Minneapolis climates. The results show up to a 39% reduction in heating, ventilation, and air-conditioning (HVAC) related electricity consumption for the cold climate compared to the Base case which has window and wall properties based on ASHRAE standard 90.1 2019. In the hot climate, a modest increase in electricity consumption was seen due to an increase in cooling electricity demand. The ADU achieved Net Zero Energy performance in all 3 Climate Zones despite having the highest exterior surface area-to-floor area ratio: the ADU also had the highest PV kW to floor area ratio compared to the other multi-story building types. The townhomes, hotel and stacked flats respectively met 73, 52 and 57 % of electrical use in Houston, 71, 48 and 56 % in New York, and 63, 40 and 53 % in Minneapolis from energy produced by rooftop solar. If 400 W solar panels are used instead of 320 W panel used for energy simulation, it is estimated that in the townhomes, hotel and stacked flats rooftop solar can meet 91, 65 and 71 % of electrical use in Houston; 89, 60 and 70% in New York, and 79, 50 and 66 % in Minneapolis. A preliminary evaluation of cost shows that such superior performance can potentially be achieved at less first cost with this 24"on-center solution than conventional construction. All the building types at the three locations used for simulation had net energy use intensity under 20 kBtu/sf/year with 320 W solar panel and under 17 kBtu/sf/year with 400 W solar panel. Further tailoring of building envelope R-values and window solar heat gain to particular Climate Zone locations for each building type shows promise in reducing the HVAC electricity use that comprises almost half of building energy use.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI

Benefits of Dual Fuel Heat Pump Grid-responsive Control: A Model-based Control Optimization Approach Using Building and Equipment Co-simulation

Conventional dual fuel heat pumps lack the intelligent control mechanisms to efficiently manage the switch between heat pump and furnace, leading to sub-optimal energy usage and, in some cases, increased operating costs. To resolve this gap, this study applies optimized control on hybrid heat pumps. With a focus on equipment control strategies, we compare the performances of five spacing heating equipment, including a conventional heat pump (HP), a conventional furnace, a dual fuel heat pump (DFHP) with conventional control, a dual fuel heat pump with smart control, and a novel seamlessly fuel flexible heat pump (SFFHP). While DFHP runs on either gas or electricity at any given moment, SFFHP concurrently consumes gas and electricity by continuously optimizing the proportion of each. In this research, a co-simulation framework is developed by integrating a building envelope model with a physics-based heat pump simulation model to analyze the benefits of grid-responsive controls of DFHP and SFFHP. The model-based optimal controls adjust the operation of the heat pump and gas furnace based on utility price signals and marginal grid emission to minimize utility cost and CO 2 emissions for multiple climate zones, different utility tariffs, and marginal grid emission scenarios. Case studies in Chicago and Los Angeles demonstrate that SFFHP and DFHP, with model-based optimal control, can deliver significant reductions in peak demand, utility cost, and CO 2 emission. In Chicago, SFFHP and smart controlled DFHP yield up to 64.7% and 61.7% utility cost reduction and up to 15.7% and 8.5% CO 2 emission reduction compared to the gas furnace. In Los Angeles, SFFHP and smart controlled DFHP achieve up to 43.6% and 40.1% utility cost reduction and up to 13.8% and 14.1% CO2 emission reduction compared to conventional heat pumps. In conclusion, by leveraging the fuel flexibility nature of dual fuel heat pumps, the model-based control optimization approach makes dual fuel heat pump an attractive option for demand response programs.

Control

High-performance windows improve thermal survivability of occupants during cold snaps

Exposure to low indoor air temperature is a major contributor to temperature-related mortality during extreme cold events, especially when power outages disrupt operation of space heating systems. This study explores the impact of high-performance windows on the thermal resilience of residential buildings during extreme cold weather and grid power outages, as well as their long-term benefits through energy efficiency and reduced risk of property damage. Building performance simulations were conducted for reference residential buildings in three construction vintages and two major U.S. cities located in cold climate zones, considering two types of extreme cold events: short and severe, and long and milder. Our research found that even houses compliant with current energy codes struggle to maintain safe indoor temperatures for more than a few hours during power outages, necessitating rapid evacuations. High-performance windows can extend the thermal survivability time by up to 3.8 days within a 7-day cold snap and significantly reduce risk of bursting frozen water pipes, depending on the building’s insulation and infiltration level, cold event severity, and occupant vulnerability. This extended thermal safety time is crucial in scenarios where reduced mobility complicates emergency responses in senior housing. In addition to boosting thermal resilience, upgrading older homes with high-performance windows can reduce heating energy consumption by over 18% and cooling energy by 15%. Our findings highlight the need to incorporate thermal resilience assessments into new designs or major retrofits, including the use of typical and extreme weather scenarios and advanced technologies like high-performance windows.

Krelling, Amanda F

Deep learning–based digital twins for heat pumps

Heat pumps are effective cooling and heating appliances to save energy in buildings. However, traditional heat pump models are challenging to integrate with building demands in a co-simulation environment because of the nonlinear thermodynamics of refrigerants. Developing digital twin representatives for heat pumps capable of faster calculations with good accuracy is desirable. This study aimed to establish a generic deep learning–based digital twin for heat pumps with a large amount of high-fidelity data. Two refrigerants for two different heat pumps were considered: an air source heat pump with refrigerant R-410A, an air source heat pump with refrigerant CO 2 , a water source heat pump with refrigerant R-410A, and a water source heat pump with refrigerant CO 2 . Furthermore, results showed that the deep learning (long short-term memory) models effectively represented these four heat pumps as a digital twin: (a) accuracy for training and testing showed smaller than 0.02 for heating electricity and heating demands, and (b) the digital twins showed good consistency with original data for heating electricity and heating demands (root mean square errors of less than 0.12 W and 0.19 W, respectively). Therefore, deep learning–based heat pump models can be used in the co-simulation of building mechanical systems.

Air source heat pump

Enhancing occupant behavior representation for interoperability between building information modeling and building energy modeling

Building Performance Simulation (BPS) has been adopted as an essential tool for designing, operating, and retrofitting buildings to optimize energy efficiency throughout the building life cycle. The Green Building XML (gbXML) schema facilitates seamless data exchange between Building Information Modeling (BIM) and Building Energy Modeling (BEM) software tools. However, limited occupant behavior (OB) representation in BIM often leads to inconsistent and inaccurate energy simulation in BEM software. This paper presents 154 systematic enhancements to the existing occupant behavior XML (obXML) schema v1.3.4, initially developed for standardizing OB representation for BEM, to address existing limitations and improve interoperability with BIM models. The enhancements encompass improved integration with BIM models through extended building representations and system operations, expanded support for advanced OB models with additional environmental parameters and mathematical capabilities, and implementation of a standardized model documentation framework. To facilitate seamless data transformation between gbXML and obXML schemas, we developed a publicly available gb-obXML Schema Converter. Three case studies demonstrate the enhanced schema’s capabilities: representation of building information using a two-story office building model, documentation of a window operation behavior model, and validation of the schema converter’s functionality. The enhanced obXML schema v1.4 enables sophisticated modeling of occupant-building interactions while maintaining consistency with industry-standard BIM schemas. The standardized documentation framework facilitates reproducibility and knowledge sharing in the OB research community, while the schema converter automates the integration of building information into OB simulation workflows. These enhancements establish a foundation for more accurate building performance simulation by supporting sophisticated representation of occupant behavior within the BIM-to-BEM simulation workflows.

Chung, Jihoon

EnergyPlus-MCP: A model-context-protocol server for ai-driven building energy modeling

Traditional building energy modeling with the EnergyPlus building performance simulation engine requires domain expertise, programming skills, and intensive manual efforts limiting its effective adoption. This paper introduces EnergyPlus-MCP, the first open-source Model Context Protocol (MCP) server specifically designed for EnergyPlus simulation workflows, establishing a new foundational infrastructure for AI-driven building energy modeling. The MCP server implements a layered architecture with 35 specialized tools spanning model management, editing and analysis, HVAC and other systems configuration inspection, and simulation execution, enabling Large Language Models to interact with EnergyPlus through conversational interfaces. The server addresses critical workflow barriers by automating model validation, streamlining energy efficiency measures modification, and providing intelligent output management with interactive visualization. Through practical demonstrations using a multi-zone building retrofit analysis, we show how the EnergyPlus-MCP server significantly reduces manual efforts while maintaining full simulation rigor. By providing accessible natural language interfaces to sophisticated building energy analysis, this approach enables scalable deployment of simulation expertise across public and private organizations, educational institutions, and research teams, fundamentally transforming traditional building energy modeling practices.

AI

BSDF Data generation for daylight applications: A call for international standardization

Standardized methods for generating angle-dependent, bidirectional, solar-optical properties for complex fenestration systems do not exist, which means that energy and daylight evaluations in building performance simulations often suffer from major inaccuracies. This position paper provides an overview of state-of-the-art data-driven methods for characterizing light scattering properties of fenestration materials and blind systems (e.g. fabrics, metal slats, patterned glazing), validation via laboratory, simulation and field tests, and salient issues in support of standardization of such methods via the International Standardization Organization (ISO). The ISO standard is intended to provide the fundamental underpinnings for recently mandated daylight standards that rely on bidirectional scattering distribution function data for climate-based daylight modelling and building performance simulations.

Geisler-Moroder, D.

ComStock Measure Documentation: High-Efficiency Rooftop Unit

Building on the 3-year End-Use Load Profiles project to calibrate and validate the U.S. Department of Energy's ResStock and ComStock models, this work produces national data sets that enable cities, states, utilities, and other stakeholders to answer a broad range of questions regarding their commercial building stock. ComStock is a highly granular, bottom-up model that uses various data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual subhourly energy consumption of the commercial building stock across the United States. The "baseline" model intends to represent the U.S. commercial building stock as it existed in 2018. The methodology of the baseline model is discussed in the ComStock Reference Documentation. The goal of this work is to develop energy efficiency and demand flexibility measures that cover market-ready technologies and study their mass adoption impact on the baseline building stock. "Measures" refers to various "what-if" scenarios that can be applied to buildings. The results for the baseline and measure scenario simulations are published in public data sets that provide insights into building stock characteristics, operational behaviors, utility bill impacts, and annual and sub-hourly energy usage by fuel type and end use. This report describes the modeling methodology for a single ComStock measure scenario - high-efficiency rooftop unit (RTU) - and briefly introduces key results. The full public data set can be accessed on the Comstock data lake or via the Data Viewer at comstock.nlr.gov. The public data set enables users to create custom aggregations of results for their use case (e.g., filter to a specific county or building type).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI

ComStock Measure Documentation: Variable-Speed Pumps

Building on the 3-year End-Use Load Profiles project to calibrate and validate the U.S. Department of Energy's ResStock and ComStock models, this work produces national data sets that enable cities, states, utilities, and other stakeholders to answer a broad range of questions regarding their commercial building stock. ComStock is a highly granular, bottom-up model that uses various data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual subhourly energy consumption of the commercial building stock across the United States. The "baseline" model intends to represent the U.S. commercial building stock as it existed in 2018. The methodology of the baseline model is discussed in the ComStock Reference Documentation. The goal of this work is to develop energy efficiency and demand flexibility measures that cover market-ready technologies and study their mass adoption impact on the baseline building stock. "Measures" refers to various "what-if" scenarios that can be applied to buildings. The results for the baseline and measure scenario simulations are published in public data sets that provide insights into building stock characteristics, operational behaviors, utility bill impacts, and annual and sub-hourly energy usage by fuel type and end use. This report describes the modeling methodology for a single ComStock measure scenario - variable speed pumps - and briefly introduces key results. The full public data set can be accessed on the ComStock data lake or via the Data Viewer at comstock.nlr.gov. The public data set enables users to create custom aggregations of results for their use case (e.g., filter to a specific county or building type).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI

ComStock Measure Documentation: Fan Static Pressure Reset for Multizone Variable Air Volume Systems

This report assesses the potential for nationwide adoption of a duct static pressure reset in MZ VAV systems in appropriate applications. Building on the 3-year End-Use Load Profiles project to calibrate and validate the U.S. Department of Energy’s ResStock™ and ComStock™ models, this work produces national datasets that enable cities, states, utilities, and other stakeholders to answer a broad range of questions regarding their commercial building stock. ComStock is a highly granular, bottom-up model that uses various data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual sub-hourly energy consumption of the commercial building stock across the United States. The “baseline” model intends to represent the U.S. commercial building stock as it existed in 2018. The methodology of the baseline model is discussed in the ComStock Reference Documentation. The goal of this work is to develop energy efficiency and demand flexibility measures that cover market-ready technologies and study their mass-adoption impact on the baseline building stock. “Measures” refers to various “what-if” scenarios that can be applied to buildings. The results for the baseline and measure scenario simulations are published in public datasets that provide insights into building stock characteristics, operational behaviors, utility bill impacts, and annual and sub-hourly energy usage by fuel type and end use. This report describes the modeling methodology for a single ComStock measure scenario—Fan Static Pressure Reset for Multizone Variable Air Volume (VAV) Systems—and briefly introduces key results. The full public dataset can be accessed on the ComStock data lake or via the Data Viewer at comstock.nrel.gov. The public dataset enables users to create custom aggregations of results for their use case (e.g., filter to a specific county or building type).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI

ComStock Measure Documentation: Thermostat Setbacks During Unoccupied Periods

This report assesses the potential for nationwide adoption of thermostat setbacks in appropriate applications. Building on the 3-year End-Use Load Profiles project to calibrate and validate the U.S. Department of Energy’s ResStock™ and ComStock™ models, this work produces national datasets that enable cities, states, utilities, and other stakeholders to answer a broad range of questions regarding their commercial building stock. ComStock is a highly granular, bottom-up model that uses various data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual sub-hourly energy consumption of the commercial building stock across the United States. The “baseline” model intends to represent the U.S. commercial building stock as it existed in 2018. The methodology of the baseline model is discussed in the ComStock Reference Documentation. The goal of this work is to develop energy efficiency and demand flexibility measures that cover market-ready technologies and study their mass-adoption impact on the baseline building stock. “Measures” refers to various “what-if” scenarios that can be applied to buildings. The results for the baseline and measure scenario simulations are published in public datasets that provide insights into building stock characteristics, operational behaviors, utility bill impacts, and annual and sub-hourly energy usage by fuel type and end use. This report describes the modeling methodology for a single ComStock measure scenario— Thermostat Setbacks During Unoccupied Periods—and briefly introduces key results. The full public dataset can be accessed on the ComStock data lake or via the Data Viewer at comstock.nrel.gov. The public dataset enables users to create custom aggregations of results for their use cases (e.g., filter to a specific county or building type).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI

Virtual Build: Low-Tech Simulations Can be High on IPPD Content

This people-based simulation is a game that can be used to rehearse complex first-time product assembly activities before the chips are down and the pressure is on to perform. Our experiences with this technique resulted in significantly improved manufacturing planning through better communication in an Integrated Product Team environment.

Hilscher, R.

Simulation & Analysis of the Hydronic Shell Retrofit System as a Solution for Deep Energy Retrofits and Electrification of Large Multifamily Housing Communities in Cold Climate

Among 32 million multi-family buildings in the United States, approximately 42% have poor or no insulation. Envelope retrofits of these buildings will provide thermal resiliency and enable a pathway to electrification of space heating systems as a result of improved thermal performance. Hydronic Shell (HS) is a technology which combines an insulated retrofit panel with a heating, ventilation and air-conditioning (HVAC) thus enabling both envelope retrofit and space heating electrification. In this study, we used whole building energy simulation to evaluate energy impact of multi-family building retrofit with hydronic shell system. The simulation was performed for four locations of New York, Syracuse, Chicago and Boston. The results from the simulation showed more than 66% cooling energy reduction and more than 88% heating energy reduction from Hydronic Shell retrofit compared to Baseline building in all four locations. This reduction in energy consumption resulted in up to 219 MT reduction in annual CO2 emission. The cost reduction per floor area achieved from HVAC energy consumption reduction using Hydronic Shell retrofit was 0.66 to 0.99 $\$$/ft 2 . The results also showed higher percentage of heating energy reduction comes from the envelope only retrofit and higher percentage of cooling energy reduction comes from the retrofit HVAC system for the four locations under study.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI

Simulation of probabilistic wind loads and building analysis

Probabilistic wind loads likely to occur on a structure during its design life are predicted. Described here is a suitable multifactor interactive equation (MFIE) model and its use in the Composite Load Spectra (CLS) computer program to simulate the wind pressure cumulative distribution functions on four sides of a building. The simulated probabilistic wind pressure load was applied to a building frame, and cumulative distribution functions of sway displacements and reliability against overturning were obtained using NESSUS (Numerical Evaluation of Stochastic Structure Under Stress), a stochastic finite element computer code. The geometry of the building and the properties of building members were also considered as random in the NESSUS analysis. The uncertainties of wind pressure, building geometry, and member section property were qualified in terms of their respective sensitivities on the structural response.

Shah, Ashwin R.

Wakes from arrays of buildings

Experiments were carried out in a small wind tunnel in which atmospheric flow around buildings was simulated. Arrays of one, two, three, and four model buildings were tested, and wake profiles of velocity and turbulence were measured. The data indicate the effect of the buildings on the wind environment encountered by aircraft during landing or takeoff operations. It was possible to use the results to locate the boundaries of the air regions affected by the obstacles and to recommend preferred arrangements of buildings to maximize light safety.

Logan, E., Jr.