Search NASA⌕ Search

SEARCH · Search NASA

Results for “CALORIMETERS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Low-energy calibration of SuperCDMS HVeV cryogenic silicon calorimeters using Compton steps

Cryogenic calorimeters for low-mass dark matter searches have achieved sub-eV energy resolutions, driving advances in both low-energy calibration techniques and our understanding of detector physics. The energy deposition spectrum of gamma rays scattering off target materials exhibits step-like features, known as Compton steps, near the binding energies of atomic electrons. Here, we demonstrate a successful use of Compton steps for sub-keV calibration of cryogenic silicon calorimeters, utilizing four SuperCDMS High-Voltage eV-resolution detectors operated with 0 V bias across the crystal. This new calibration at 0 V is compared with the established high-voltage calibration using optical photons. The comparison indicates that the detector response at 0 V is about 30% weaker than expected, highlighting challenges in detector response modeling for low-mass dark matter searches.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Beam Test Results of the RADiCAL—A Radiation Hard Innovative EM Calorimeter

High-performance calorimetry conducted at future hadron colliders, such as the FCC-hh, poses a significant challenge for applying current detector technologies due to unprecedented beam luminosities and radiation fields. Solutions include developing scintillators that are capable of separating events at the sub-fifty picosecond level while also maintaining performance after extreme and constant neutron and ionizing radiation exposure. The radiation-hard innovative calorimeter (RADiCAL) is an approach that incorporates radiation tolerant materials in a sampling “shashlik”-style calorimeter configuration, using quartz capillaries filled with organic liquid or polymer-based wavelength shifters embedded in layers of tungsten plates and lutetium-yttrium oxyorthosilicate (LYSO) crystals. Here, this novel design intends to address the priority research directions (PRD) for calorimetry listed in the DOE basic research needs (BRN) workshop for high energy physics (HEP) instrumentation. Here we report preliminary results from an experimental run at the Fermilab Test Beam Facility (FTBF) in June 2022. These tests demonstrate that the RADiCAL concept is capable of ¡50 ps timing resolution.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

ADRIANO2 Calorimeter Performance from 2022 Test Beams

A novel high-granularity dual-readout calorimetric technique was developed as part of the T1604 collaboration. The ADRIANO2 Calorimeter Prototype consists of a pair of optically isolated, small sized tiles made of scintillating plastic and lead glass. Čerenkov light from the lead glass are exploited to for high resolution timing measurements, while high granularity from scintillating plastic can be used to probe the spatial component of the particle shower. This setup works for excellent energy resolution and particle detection for REDTOP as it is crucial for a calorimeter to detect the decay products of eta/eta-prime mesons. Measurements were collected on ADRIANO2 between February to December 2022 to evaluate the detector performance at Fermilab’s Test Beam Facility. The key metrics extracted from my analysis are the detector’s efficiency for various tile configuration and light-yield which will then be used as parameters for an upgraded REDTOP monte-carlo simulation campaign. An in-depth analysis of ADRIANO2 performance are detailed in this presentation.

43 PARTICLE ACCELERATORS↗

Design and assembling status of the Mu2e electromagnetic calorimeter mechanical structures

The muon-to-electron conversion (Mu2e) experiment at Fermilab will search for the Charged Lepton Flavour Violating neutrino-less coherent conversion of a muon into an electron in the field of an aluminum nucleus. The observation of this process would be the unambiguous evidence of physics beyond the Standard Model. The detector has been designed as a state-of-the-art crystal calorimeter and employs 1348 pure Cesium Iodide (CsI) crystals readout by UV-extended silicon photosensors and fast front-end and digitization electronics. A design consisting of two identical annular matrices (named disks ) positioned at the relative distance of 70 cm, downstream the aluminum target along the muon beamline, satisfies the Mu2e physics requirements. The hostile Mu2e operational conditions, in terms of radiation levels (total ionizing dose of 12 krad and a neutron fluence of 5 10^{10} n/cm2 @ 1 MeVeq (Si)/y), magnetic field intensity (1 T) and vacuum level (10−4 Torr) have posed tight constraints on the design of the detector mechanical structures and materials choice. The support structure of the two 674 crystal matrices employs two aluminum hollow rings and parts made of open- cell vacuum-compatible carbon fiber. The photosensors and service front-end electronics for each crystal are assembled in a unique mechanical unit inserted in a machined copper holder. The 674 units are supported by a machined plate made of vacuum-compatible plastic material. The plate also integrates the cooling system made of a network of copper lines flowing a low temperature radiation-hard fluid and placed in thermal con- tact with the copper holders. The data acquisition electronics is hosted in aluminum custom crates positioned on the external lateral surface of the two disks. The crates also integrate the electronics cooling system. In this poster we will review the constraints on the calorimeter mechanical structures, the technological choices, and the status of assembling at Fermilab.

Pasciuto, D.↗

Simulating the CMS High Granularity Calorimeter with ML

Detector simulation is a key component of physics analysis and related activities in CMS. In the upcoming High Luminosity LHC era, simulation will be required to use a smaller fraction of computing in order to satisfy resource constraints. At the same time, CMS will be upgraded with the new High Granularity Calorimeter (HGCal), which requires significantly more resources to simulate than the existing CMS calorimeters. This computing challenge motivates the use of generative machine learning models as surrogates to replace full physics-based simulation. We study the application of state-of-the-art diffusion models to simulate particle showers in the CMS HGCal. We will discuss methods to overcome the challenges posed by the high-dimensional, irregular geometry of the HGCal. The quality of the showers produced by the diffusion model will be assessed by comparison to the full GEANT4-based simulation. The increase in simulation throughput will be quantified and methods to accelerate the diffusion model inference will also be discussed.

Amram, Oz↗

A new active base of photomultiplier R4125 designed for the PbWO4 calorimeter

This paper presents the design, performance, and results of the radiation tests of an active base for Hamamatsu R4125 photomultiplier tube. The active base was designed at Jefferson Lab and comprises of a high voltage divider and an on-board amplifier. The photomultiplier with the active base is used to detect light from lead tungstate scintillating crystals of the forward electromagnetic calorimeter of the GlueX detector. The active base amplifier allows to operate the tube at lower high voltage and thus to limit the photomultiplier anode current to a few micro ampereres at the maximum counter rate of 1 MHz counter, while retaining the dynamic range of output signals. The performance of calorimeter modules instrumented with the active base was studied using detector prototypes positioned into the beam of photons. The key performance parameters such as the linearity, high-rate capability, and the energy resolution verified that the active base design meets the detector specifications

Somov, Alexander [Thomas Jefferson National Accele↗

Dual Readout in Homogenous Inorganic Scintillators for Precision Calorimeters

Homogeneous inorganic scintillator-based calorimeters are the gold standard for electromagnetic energy resolution, but often degrade the hadronic energy resolution achievable at colliders. By incorporating the dual readout technique, we seek to improve the hadronic energy resolution of these calorimeters through the measurement and separation of the scintillation and Cherenkov light in hadronic showers. In April 2024, CalVision performed single-crystal tests using the electron test beam at DESY. Using a single delay line technique for waveform analysis, sufficient cerenkov light can be extracted to fully capitalize on the dual readout technique. This talk will present the results of PWO, BGO, BSO, PbF2, and two novel scintillating glasses.

Anderson, Thomas [Virginia U.]↗

Detector architecture and data flow of the CMS HGCAL Phase-2 Endcap Calorimeter Upgrade

The CMS High Granularity Calorimeter (HGCAL) is the Phase-2 endcap calorimeter upgrade for the High-Luminosity Large Hadron Collider, designed to provide precise spatial, energy, and timing measurements in a high-radiation, high-pileup environment. This work presents an overview of the HGCAL assembly process, detector architecture, and end-to-end data flow. The data flow goes from signal generation in silicon sensors and scintillator tiles through front-end electronics, optical transmission, and back-end data acquisition. The study highlights how the integrated detector, electronics, and readout systems enable efficient event reconstruction and support the physics objectives of the HL-LHC.

Osei Boakye, Prince [Grambling State U.]↗

Assembly and Testing of Scintillator Tile Modules for the CMS High-Granularity Calorimeter Upgrade

The High-Granularity Calorimeter (HGCAL), part of the upgrade to the Compact Muon Solenoid (CMS) experiment, employs silicon and scintillator tile modules in the endcaps to maintain detector performance during the High-Luminosity Large Hadron Collider (HL-LHC) era, scheduled to operate from 2030 to 2040. The upgraded calorimeter will provide highly segmented three-dimensional imaging, energy measurements, and precise timing for particle shower reconstruction. Approximately half of the HGCal plastic scintillator tile modules (1,834 total) will be assembled at Fermilab using an automated pick-and-place (PnP) machine. Following assembly, each tile module undergoes quality control (QC) procedures such as electrical validation, thermal testing, and physics validation using cosmic rays. This poster/talk presents the QC procedures and results from the tile module production in 2026, demonstrating the performance and quality of the assembled tile modules.

Bazimya, Jean Luc [Grambling State U.]↗

The Readout Electronics of the Mu2e Electromagnetic Calorimeter

The Mu2e electromagnetic calorimeter has been designed to measure ~100 MeV electrons with energy resolution σE/E <10%, time resolution σt < 500ps and position resolution σx < 1cm. The detector is composed of 1348 un-doped CsI crystals coupled to two large area Silicon Photomultipliers (SiPMs). Each SiPM is connected to a Front End Electronics (FEE) chip which hosts the shaping amplifier and the high voltage linear regulator. A group of 20 FEE is controlled by one Mezzanine Board (MB) which transmits the amplified signals to one Digitizer ReAdout Controller board (DiRAC). The DiRAC samples the waveforms at 200 MHz with 12-bit ADCs, packs the data according to the Mu2e custom format and transmits them to the event builder through an optical transceiver. To limit the number of pass-through connectors and the length of the cables, the readout and digitization electronics is located inside the detector cryostat and close to the interaction target. The boards will have to sustain a neutron fluence of about 5x10 10 n/cm 2 @ 1 MeVeq (Si)/y and a Total Ionizing Dose of about 12 krad, while working into a 1T magnetic field and a vacuum of 10 (-4) Torr. This harsh operational environment has made the electronics design challenging and required an extended campaign of tests to select and qualify the employed electronic components. In this paper we report on the board architecture and design, on the qualification of the prototypes, as well as on the results of the first vertical slice test of the Mu2e calorimeter.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Mu2e Calorimeter

The EM CsI crystals and SiPM readout calorimeter of the Mu2e experiment is fully assembled, with all components completed and tested; the mechanical structure is fully built, with a complete integration and test of all the analog sensors and electronics. The digital electronics is being produced and installed. We summarise the Calorimeter characteristics and the assembly status, as well as the move, installation and commissioning plans of the final disks in the Mu2e hall.

Borrel, L. [Caltech]↗

Performance of the AstroPix Prototype Module for the Barrel Imaging Calorimeter at the ePIC Detector and in Space-Based Payloads

AstroPix is a high-voltage CMOS (HV-CMOS) monolithic active pixel sensor originally developed to enable precision gamma-ray imaging and spectroscopy in the medium-energy regime (~100 keV–100 MeV) based on the groundwork laid by ATLASpix and MuPix. It features a 500 μm pixel pitch, in-pixel amplification and digitization, and low power consumption (~3-4 mW/cm2), making it scalable for large-area, multilayer telescope detector planes. The detectors have a designed dynamic range of 25 keV to 700 keV. With these features, AstroPix meets the requirements of future space-based high-energy telescopes and the imaging layers of the Barrel Imaging Calorimeter (BIC) in the Electron-Proton/Ion Collider (ePIC) detector at the future Electron-Ion Collider (EIC). For the space-based payload, AstroPix is being integrated into sounding rocket and balloon payloads to demonstrate the technical readiness of the devices. For BIC, AstroPix-based imaging layers interleaved within the lead/scintillating-fiber (Pb/SciFi) sampling calorimeter provide granular shower imaging, enabling key performance features such as electron/pion or gamma/neutral pion separation. As part of the ongoing detector R&D efforts, we have been testing various AstroPix_v3 configurations: the single chip, a quad-chip assembly, a three-layer stack of quad chips, and a 9-chip module that represents the smallest prototype unit of the BIC imaging layer. This presentation will highlight recent performance test results from these AstroPix detector configurations.

Kim, Bobae (ORCID:0000000295396815)↗

Porting HEP Parameterized Calorimeter Simulation Code to GPUs

The High Energy Physics (HEP) experiments, such as those at the Large Hadron Collider (LHC), traditionally consume large amounts of CPU cycles for detector simulations and data analysis, but rarely use compute accelerators such as GPUs. As the LHC is upgraded to allow for higher luminosity, resulting in much higher data rates, purely relying on CPUs may not provide enough computing power to support the simulation and data analysis needs. As a proof of concept, we investigate the feasibility of porting a HEP parameterized calorimeter simulation code to GPUs. We have chosen to use FastCaloSim, the ATLAS fast parametrized calorimeter simulation. While FastCaloSim is sufficiently fast such that it does not impose a bottleneck in detector simulations overall, significant speed-ups in the processing of large samples can be achieved from GPU parallelization at both the particle (intra-event) and event levels; this is especially beneficial in conditions expected at the high-luminosity LHC, where extremely high per-event particle multiplicities will result from the many simultaneous proton-proton collisions. We report our experience with porting FastCaloSim to NVIDIA GPUs using CUDA. A preliminary Kokkos implementation of FastCaloSim for portability to other parallel architectures is also described.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Perspectives on the Calibration of CNN Energy Reconstruction in Highly Granular Calorimeters

We present a study which shows encouraging stability of the response linearity for a simulated high granularity calorimeter module reconstructed by a CNN model to miscalibration, bias, and noise effects. Our results also show an intuitive, quantifiable relationship between these factors and the calibration parameters. We trained a CNN model to reconstruct energy in the calorimeter module using simulated single-pion events; we then observed the response of the model under various miscalibration, bias, and noise conditions that affected the model input. From these data, we estimated linear response models to calibrate the CNN. We also quantified the relationship between these factors and the calibration parameters by regression analysis.

Akchurin, Nural↗

GNN-based end-to-end reconstruction in the CMS Phase 2 High-Granularity Calorimeter

We present the current stage of research progress towards a one-pass, completely Machine Learning (ML) based imaging calorimeter reconstruction. The model used is based on Graph Neural Networks (GNNs) and directly analyzes the hits in each HGCAL endcap. The ML algorithm is trained to predict clusters of hits originating from the same incident particle by labeling the hits with the same cluster index. We impose simple criteria to assess whether the hits associated as a cluster by the prediction are matched to those hits resulting from any particular individual incident particles. The algorithm is studied by simulating two tau leptons in each of the two HGCAL endcaps, where each tau may decay according to its measured standard model branching probabilities. The simulation includes the material interaction of the tau decay products which may create additional particles incident upon the calorimeter. Using this varied multiparticle environment we can investigate the application of this reconstruction technique and begin to characterize energy containment and performance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

ADRIANO2 Calorimeter performance from 2022 Prototypes

A novel high-granularity dual-readout calorimetric technique was developed as part of the T1604 collaboration research program. The building block of ADRIANO2 Calorimeter consists of a pair of optically isolated, small sized tiles made of scintillating plastic and lead glass. The two components of the dual-readout energy compensation technique. Furthermore,Cˇerenkovlightfromtheleadglassareexploitedtoforhighresolutiontimingmeasurements,whilehigh granularity from scintillating plastic can be used to probe the spatial component of the particle shower. This setup works for excellent energy resolution and particle identification for REDTOP as it is crucial for a calorimeter to detect and identify the decay products of eta/eta-prime mesons. Measurements were collected on several ADRIANO2 prototypes between February to December 2022 to evaluate the detector performance. The key metrics extracted from the analyses are presented in this paper are the efficiencies and light-yi eld for various tile configurations. The measured values will be used as input parameters for improved REDTOP Montecarlo simulation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Enhancing ICARUS and REDTOP Software and Hardware: Event Generator Interface Development and Calorimeter Tile Prototype

ICARUS (Imaging Cosmic And Rare Underground Signals) is a liquid argon time projection chamber (LArTPC) detector that pursues the sterile neutrino, which relies on accurate simulations of neutrino-argon interactions. REDTOP (Rare Eta Decays To Observe new Physics) is a proposed low-energy, high-intensity meson factory designed to explore rare $\eta$/$\eta'$ meson decays and probe physics beyond the Standard Model. As a next-generation experiment, this requires both accurate simulations and innovative detector technologies. This project contributes to both ICARUS, from a simulation perspective, and REDTOP, from both a simulation and detection perspective, through the event generation of lepton-nucleon interactions and the physical enhancement of the calorimeter technology within the REDTOP detector. We developed an interface between ACHILLES (A CHIcago Land Lepton Event Simulator), a theory-driven lepton-level event generator, and GENIE, a robust event generator framework used for neutrino physics. By incorporating the precise theoretical cross-section calculations of ACHILLES into the experimental realism of GENIE, the interface allows for improved accuracy of neutrino-nucleon simulations, which can be adapted for the proton beam specifications of the REDTOP meson factory as well as for the ICARUS experiment. In parallel, we developed an improved prototype for the ADRIANO2 (A Dual Readout Integrally Active Non-segmented Option) dual-readout calorimeter tiles for the REDTOP detector. To improve the efficiency of the lead-glass tiles trapping Cherenkov light for energy reconstruction and particle identification, we optimized the application of a highly reflective coating. Through viscosity and thickness control, masking, and a custom spray technique, we refined the coating process to reduce surface defects and improve light yield. Together, these efforts strengthen the ICARUS neutrino program and REDTOP's capability of detecting rare decay events.

Visser, Erin [Michigan State U.] (ORCID:0009000184↗

CaloTrilogy: Toward a Breakthrough in One-Step, End-to-End, Physics-Guided Shower Generation for Modern Calorimeters

High-precision calorimeter simulation at current and future colliders imposes rapidly growing computational demands, motivating the development of machine-learning surrogates for traditional Monte Carlo tools such as Geant4. Flow matching and diffusion-based generative models have become leading approaches for high-dimensional fast simulation because of their sample quality, but typically require ${\cal O}(100)$ function evaluations at inference and often rely on auxiliary networks to constrain global observables, compromising streamlined end-to-end generation. We introduce a unified framework that improves the balance between speed, shower quality, and physics fidelity. The method combines: (i) an average velocity field integrator that enables sampling in one or a few evaluations; (ii) a learned generative prior in shower space, constructed from data rather than random noise; and (iii) physics-guided loss terms that impose inductive biases on key observables during training. These elements are training time regularizers, preserving end-to-end inference with no additional cost. With only one or a few evaluation steps, the model achieves shower quality competitive with state-of-the-art flow and diffusion approaches, tested on several public high granularity calorimeter datasets. The results demonstrate inter-layer shower structure consistent with the underlying physics, providing a strong candidate for future fast simulation workflows.

Jiang, Cheng [Edinburgh U.]↗