Search NASA⌕ Search

SEARCH · Search NASA

Results for “CENTRIFUGE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Centrifugal intensity and duration as countermeasures to soleus muscle atrophy

The effects of artificially induced gravity on the atrophy process of slow-twitch soleus muscle are studied in order to determine whether centrifugation could be an effective countermeasure to nonweight bearing at 1 G. It is observed that the soleus muscle atrophied 32 percent during seven days of nonweight bearing without countermeasures, and centrifugation treatment did not completely prevent atrophy relative to precontrol wet weight of the soleus muscle. Nonweight-bearing groups receiving treatments of 1, 1.5, or 2.6 G had 48, 56, and 65 percent, respectively, of the atrophy observed in a nonweight-bearing-only group compared with the precontrol group. It is concluded that, as a countermeasure to nonweight-bearing-induced atrophy of the soleus muscle, centrifugation at 2.6 G is no more effective than exposure to 1 or 1.5 G.

D'Aunno, Dominick S.↗

Space Station Centrifuge: A Requirement for Life Science Research

A centrifuge with the largest diameter that can be accommodated on Space Station Freedom is required to conduct life science research in the microgravity environment of space. (This was one of the findings of a group of life scientists convened at the University of California, Davis, by Ames Research Center.) The centrifuge will be used as a research tool to understand how gravity affects biological processes; to provide an on-orbit one-g control; and to assess the efficacy of using artificial gravity to counteract the deleterious biological effect of space flight. The rationale for the recommendation and examples of using ground-based centrifugation for animal and plant acceleration studies are presented. Included are four appendixes and an extensive bibliography of hypergravity studies.

Smith, Arthur H.↗

NASA low-speed centrifugal compressor for 3-D viscous code assessment and fundamental flow physics research

A low speed centrifugal compressor facility recently built by the NASA Lewis Research Center is described. The purpose of this facility is to obtain detailed flow field measurements for computational fluid dynamic code assessment and flow physics modeling in support of Army and NASA efforts to advance small gas turbine engine technology. The facility is heavily instrumented with pressure and temperature probes, both in the stationary and rotating frames of reference, and has provisions for flow visualization and laser velocimetry. The facility will accommodate rotational speeds to 2400 rpm and is rated at pressures to 1.25 atm. The initial compressor stage being tested is geometrically and dynamically representative of modern high-performance centrifugal compressor stages with the exception of Mach number levels. Preliminary experimental investigations of inlet and exit flow uniformly and measurement repeatability are presented. These results demonstrate the high quality of the data which may be expected from this facility. The significance of synergism between computational fluid dynamic analysis and experimentation throughout the development of the low speed centrifugal compressor facility is demonstrated.

Hathaway, M. D.↗

Dynamics and stability of a tethered centrifuge in low earth orbit

The three-dimensional attitude dynamics of a spaceborne tethered centrifuge for artificial gravity experiments in low earth orbit is analyzed using two different methods. First, the tethered centrifuge is modeled as a dumbbell with a straight viscoelastic tether, point tip-masses, and sophisticated environmental models such as nonspherical gravity, thermal perturbations, and a dynamic atmospheric model. The motion of the centrifuge during spin-up, de-spin, and steady-rotation is then simulated. Second, a continuum model of the tether is developed for analyzing the stability of lateral tether oscillations. Results indicate that the maximum fluctuation about the 1-g radial acceleration level is less than 0.001 g; the time required for spin-up and de-spin is less than one orbit; and lateral oscillations are stable for any practical values of the system parameters.

Quadrelli, B. M.↗

Research opportunities with the Centrifuge Facility

The Centrifuge Facility on Space Station Freedom will consist of a 2.5-meter diameter Centrifuge accommodating two concentric rings of habitats and providing variable g-forces between 0.01 g and 2.0 g; modular habitats providing housing and lifesupport for rats, mice, and plants; a habitat holding system providing power, water, airflow and other utilities to several modular habitats; and a life sciences glovebox, an isolated work volume accommodating simultaneous operations by at least two scientists and providing lighting, airflow, video and data access, and other experiment support functions. The centrifuge facility will enable long-duration animal and plant microgravity research not previously possible in the NASA flight research program. It will offer unprecedented opportunities for use of on-board 1-g control populations and statistically significant numbers of specimens. On orbit 1-g controls will allow separation of the effects of microgravity from other environmental factors. Its selectable-g and simultaneous multiple-g capabilities will enable studies of gravitational thresholds, the use of artificial gravity as a countermeasure to the effects of microgravity, and ready simulation of Lunar and Martian gravities.

Funk, Glenn A.↗

Numerical modeling of crystal growth on a centrifuge for unstable natural convection configurations

The fluid mechanics associated with crystal growth processes on centrifuges is modeled using 2D and 3D models. Two-dimensional calculations show that flow bifurcations exist in such crystal growth configurations where the ampoule is oriented in the same direction as the resultant gravity vector and a temperature gradient is imposed on the melt. A scaling analysis is formulated to predict the flow transition point from the natural convection dominated regime to the Coriolis force dominated regime. Results of 3D calculations are presented for two thermal configurations of the crystal growth cell: top heated and bottom heated with respect to the centrifugal acceleration. In the top heated configuration, a substantial reduction in the convection intensity within the melt can be attained by centrifuge operations, and close to steady diffusion-limited thermal conditions can be achieved over a narrow range of the imposed microgravity level. In the bottom heated configuration the Coriolis force has a stabilizing effect on fluid motion by delaying the onset of unsteady convection.

Ramachandran, N.↗

Clinostats and Centrifuges: Their Use, Value, and Limitations in Gravitational Biological Research

The present volume addresses physical phenomena and effects associated with clinostat and centrifuge operations as well as their physiological effects. Particular attention is given to the simulation of the gravity conditions on the ground, the internal dynamics of slowly rotating biological systems, and qualitative and quantitative aspects of the fast-rotating clinostat as a research tool. Also discussed are the development and use of centrifuges in gravitational biology, the use of centrifuges in plant gravitational biology and a comparison of ground-based and flight experiment results, the ability of clinostat to mimic the effect of microgravity on plant cells and organs, and the impact of altered gravity conditions on early EGF-induced signal transduction in human epidermal A431 cells.

Halstead, Thora W.↗

A model for the selective amplification of spatially coherent waves in a centrifugal compressor on the verge of rotating stall

A simple model for the stability zones of a low speed centrifugal compressor is developed, with the goal of understanding the driving mechanism for the changes in stalling behavior predicted for, and observed in, the Purdue Low Speed Centrifugal Research Compressor Facility. To this end, earlier analyses of rotating stall suppression in centrifugal compressors are presented in a reduced form that preserves the essential parameters of the model that affect the stalling behavior of the compressor. The model is then used to illuminate the relationship between compressor geometry, expected mode shape, and regions of amplification for weak waves which are indicative of the susceptibility of the system to rotating stall. The results demonstrate that increasing the stagger angle of the diffuser vanes, and consequently the diffusion path length, results in the compressor moving towards a condition where higher-order spatial modes are excited during stall initiation. Similarly, flow acceleration in the diffuser section caused by an increase in the number of diffuser vanes also results in the excitation of higher modes.

Lawless, Patrick B.↗

Experimental and computational investigation of the NASA low-speed centrifugal compressor flow field

An experimental and computational investigation of the NASA Lewis Research Center's low-speed centrifugal compressor (LSCC) flow field was conducted using laser anemometry and Dawes' three-dimensional viscous code. The experimental configuration consisted of a backswept impeller followed by a vaneless diffuser. Measurements of the three-dimensional velocity field were acquired at several measurement planes through the compressor. The measurements describe both the throughflow and secondary velocity field along each measurement plane. In several cases the measurements provide details of the flow within the blade boundary layers. Insight into the complex flow physics within centrifugal compressors is provided by the computational fluid dynamics analysis (CFD), and assessment of the CFD predictions is provided by comparison with the measurements. Five-hole probe and hot-wire surveys at the inlet and exit to the impeller as well as surface flow visualization along the impeller blade surfaces provided independent confirmation of the laser measurement technique. The results clearly document the development of the throughflow velocity wake that is characteristic of unshrouded centrifugal compressors.

Hathaway, Michael D.↗

Centrifugal trapping in the magnetotail

Particles leving the neutral sheet in the distant magnetotail at times display adiabatic trajectory sequences characterized by an inflection toward the equator and subsequent mirroring in its vicinity. We demonstrate that this low-latitude mirroring results primarily from a centrifugal deceleration due to the fast direction-changing E x B drift. This effect which we refer to as 'centrifugal trapping' appears both in guiding centre and full particle treatments. It thus does not directly relate to nonadiabatic motion. However, pitch angle scattering due to nonadiabatic neutral sheet interaction does play a role in reducing the parallel speed of the particles. We show that centrifugal trapping is an important mechanism for the confinement of the slowest (typically below the equatorial E x B drift speed) plasma sheet populations to the midplane vicinity.

Delcourt, D. C.↗

Enhanced Detection of Vibrio Cholerae in Oyster Homogenate Based on Centrifugal Removal of Inhibitory Agents

The disease cholera, caused by Vibrio cholerae, has been associated with consumption of contaminated seafood, including raw oysters. Detection of V. cholerae in foods typically involves blending the oysters, diluting the homogenate in alkaline peptone water (APW), overnight enrichment, and isolation on selective agar. Unfortunately, the oyster homogenate must be diluted to large volumes because lower dilutions inhibit the growth of V. cholerae. The goals of this study were to develop an alternative to large dilutions and to evaluate the basis for the inhibition observed in lower dilutions of oyster homogenates. Centrifugation of oyster homogenates at 10,000 x g for 15 min, followed by enrichment of the resulting pellet in APW, was found to eliminate the inhibition of V. cholerae growth. Inhibition appears not to be due to competing microflora but to a component(s) released when V. cholerae grows in the presence of oyster homogenate. The inhibitory component(s) kills the V. cholerae after the cell concentration reaches > 10(exp 8) cells/mL, rather than initially preventing their growth. The pH also declines from 8.0 to 5.5 during this period; however, the pH decline by itself appears not to cause V. cholerae death. Seven strains of V. cholerae (01 and non-01) and two strains of V. vulnificus were susceptible to the inhibitory agent(s). However, other Vibrio and non-Vibrio species tested were not inhibited by the oyster homogenates. Based on digestion of oyster homogenates with pronase, trypsin and lipase, the inhibitory reaction involves a protein(s). In a preliminary trial with oyster homogenate seeded with 1 cfu/g of V. cholerae, the modified centrifugation technique detected a slightly higher percentage of samples at a 1:10 dilution than the standard FDA Bacteriological Analytical Method (BAM) detected in uncentrifuged oyster homogenate at a 1:100 dilution. V. cholerae in seeded samples could also be detected more frequently by the modified centrifugation method than by PCR at a 1:10 dilution.

Alexander, Donita↗

Unshrouded Centrifugal Turbopump Impeller

The ratio of rocket engine thrust to weight is a limiting constraint in placing more payload into orbit at a low cost. A key component of an engine's overall weight is the turbopump weight, Reducing the turbopump weight can result in significant engine weight reduction and hence, increased delivered payload. There are two main types of pumps: centrifugal and axial pumps. These types of pumps can be further sub-divided into those with shrouds and those without shrouds (unshrouded pumps). Centrifugal pumps can achieve the same pump discharge pressure as an axial pump and it requires fewer pump stages and lower pump weight than an axial pump. Also, with unshrouded centrifugal pumps (impeller), the number of stages and weight can be further reduced. However. there are several issues with regard to using an unshrouded impeller: 1) there is a pump performance penalty due to the front open face recirculation flow; 2) there is a potential pump axial thrust problem from the unbalanced front open face and the back shroud face; and, 3) since test data is very linu'ted for this configuration, there is uncertainty in the magnitude and phase of the rotordynamics forces due to the front impeller passage. The purpose of the paper is to discuss the design of an unshrouded impeller and to examine the design's hydrodynamic performance, axial thrust, and rotordynamics performance. The design methodology will also be discussed. This work will help provide some guidelines for unshrouded impeller design. In particular, the paper will discuss the design of three unshrouded impellers - one with 5 full and 5 partial blades (5+5). one with 6+6 blades and one with 8+8 blades. One of these designs will be selected for actual fabrication and flow test. Computational fluid dynamics (CFD) is used to help design and optimize the unshrouded impeller. The relative pump performance penalty is assessed by comparing the CFD results of the unshrouded impeller with the equivalent shrouded impeller for a particular design. Limited unshrouded - versus - shrouded impeller data from the J-2 pump is used to anchor the CFD. Since no detailed impeller blade force data is available, axial thrust and rotordynamic force predictions are based on the CFD model. For the axial thrust, the impeller front flow passage axial force is integrated from the CFD results and compared to the equivalent shrouded impeller axial force. For the rotordynamics forces, the fluid reaction forces are computed from unsteady flow CFD results using a moving boundary method; the rotor- shaft is moved at several whirl-to-speed frequency ratios to extract the rotordynamics coefficients.

Prueger, George↗

Search for the Centrifugal Barrier in Transient X-Ray Pulsars

During the period 15 April 1997 through 15 April 2000 we have been supported in part by NASA grant NAG5-4115 to pursue a 'Search for the Centrifugal Barrier in Transient X-ray Pulsars' with the Rossi X-Ray Timing Explorer (RXTE). The RXTE observations associated with this research involved monitoring the X-ray intensities and pulse profiles of six transient X-ray pulsars on five different occasions. The goal was to detennine whether the so-called 'centrifugal barrier' effect exists for accretion-powered X-ray pulsars. In this long-postulated effect, accretion onto the neutron star should be inhibited when the accretion rate falls below the point where the magnetospheric boundary lies outside the neutron star's corotation radius. Our RXTE observations yielded detections of two of the six X-ray pulsars under study, but were insufficient, overall, to yield any new insight into the centrifugal barrier effect. The data from the two detected pulsars will be utilized by Professor Deepto Chakrabarty as part of his overall campaign to study the long-term behavior of accretion-powered X-ray sources.

Jefferson, Adrian↗

Peripheral Signals of Food Intake in Response to Low Leptin Levels Induced by Centrifugation

The focus of the study was to examine leptin and other peripheral signals of energy balance, following hypergravity. The study was conducted in two experiments. In experiment 1 rats were centrifuged at either 1.5, 2, or remained at 1 G. During days 8 to 14 of experiment 1, mean body mass of the 1.5 and 2 G groups was significantly (p<0.05) lower than controls. No differences were found in food intake (g/day/100 g body mass). Epididymal fat in the 2 G group was 21% lower than controls and 14% lower than the 1.5 G group. Plasma leptin was reduced from controls in the 1.5 and 2 G groups by 45 and 63%, respectively. A significant correlation was found between G load and urinary catecholamines. In experiment 2, rats were centrifuged at either 1.25, 1.5, or remained at 1 G. During days 8 to 14, body mass and food intake were similar between the 1, 1.25, and 1.5 G groups. Epididymal fat was reduced from controls in the 1.25 (14%) and 1.5 (19%) G groups. Leptin was reduced from controls in the 1.25 (45%) and 1.5 (46%) G groups. No differences were found in urinary epinephrine. Urinary norepinephrine levels were significantly higher than controls in each centrifuge group. During hypergravity exposure, food intake is the result of a complex relationship between multiple pathways, which abates the importance of leptin as a primary signal.

Moran, M. M.↗

Effects of Prolonged Centrifugation on Orthostasis

A feasibility study conducted on the Ames 20-G Human Centrifuge examined how well humans can maintain orthostatic tolerance during and after prolonged exposures to hypergravity. Three adult males lived for periods of 22 hours in the centrifuge while it was at rest (1.00 G), and while it rotated at 9.38 RPM to provide 1.25 G-total at the mean radius of 7.62 m. Two participants also experienced 22-hour habitation sessions at 11.46 RPM, which provided 1.50 G-total. Both before and after each habitation session, the participants were given gradual onset rate (GOR) acceleration profiles at 0.067 G/sec to determine their Gz tolerance. In addition, cardiovascular responses were compared while subjects were supine, siting, and standing at various times during the habitation (stand test), and cardiovascular responsiveness was determined using a lower body negative pressure tilt table (LBNPTT) at the beginning of the experiment and after each session. Post-Pre changes in G tolerance were -0.33 (mean) +/- 0.11 (std. error) Gz for habitation at 1.00 G, -0.02 +/- 0.12 Gz for habitation at 1.25 G, and +0.41 +/- 0.13 Gz for habitation at 1.50 G. Performance on the stand test generally improved with duration of habitation in hypergravity. Our results suggest that habitation in a confined chamber at 1.00 G reduces G tolerance and leads to lowered LBNPTT tolerance. Exposure to increased G in the centrifuge leads to enhanced performance on the stand test, and to increased GOR acceleration tolerance, but only when fluid balance is maintained; when motion sickness and negative fluid balance were observed, G tolerance was reduced. The data indicate that enhanced G tolerance can result from prolonged exposure to hypergravity, but that these changes are complex and depend on multiple underlying physiological processes.

Cohen, Malcolm M..↗

Peripheral Microvascular Responses to Whole-Body Tilting, G(z) Centrifugation, and Lower Body Negative Pressure Stresses in Humans

The response of the cutaneous microcirculation to orthostatic stress varies along the length of the body due to the interaction of central controls with regional responses to local blood pressure. We hypothesize that artificial orthostatic stresses such as Gz centrifugation and LBNP differ from whole-body tilting in terms of the distribution of microvascular blood flow. Cutaneous microvascular flows were measured by laser Doppler flowmetry at the neck, thigh, and leg of 15 normal subjects. Volunteers underwent stepwise head-up tilt (HUT) and short- and long-arm centrifugation protocols from supine control (0 Gz) to 0.2, 0.4, 0.6, 0.8, 1.0, 0.8, 0.6, 0.4, 0.2, and 0 Gz at the feet, for 30-s periods with 10-s transitions between levels. The same subjects underwent a corresponding supine LBNP protocol, up to 100 mmHg (in 20 mmHg increments) and back to zero pressure, which produced transmural pressure across blood vessels in the foot approximately equal to the HUT protocol. In general, application of all orthostatic stresses produced significant flow reductions in the lower body (p less than 0.05) and inconsistent changes in the neck. At low levels of each stress (0.4 Gz, 40 mmHg), LBNP generated the greatest relative reduction in flow in the lower body (-66.9+/-5.7%, thigh; -60.6 +/-5.7%, leg, mean +/- SE). HUT caused a less severe flow reduction than LBNP at the thigh and leg (-39.9 +/- 8.1% and -55.9+/-4.8%), while the effects induced by both forms of centrifugation were the least profound. Higher levels of each stress generally resulted in similar responses. These responses exhibit a consistent relationship to hypothesized changes in local microvascular transmural pressure, suggesting that myogenic and veno-arteriolar reflexes play a significant role in determining microvascular perfusion during orthostatic stress.

Breit, G. A.↗

Effects of Impeller-Diffuser Interaction on Centrifugal Compressor Performance

This research program focuses on characterizing the effect of impeller-diffuser interactions in a centrifugal compressor stage on its performance using unsteady threedimensional Reynolds-averaged Navier-Stokes simulations. The computed results show that the interaction between the downstream diffuser pressure field and the impeller tip clearance flow can account for performance changes in the impeller. The magnitude of performance change due to this interaction was examined for an impeller with varying tip clearance followed by a vaned or vaneless diffuser. The impact of unsteady impeller-diffuser interaction, primarily through the impeller tip clearance flow, is reflected through a time-averaged change in impeller loss, blockage and slip. The results show that there exists a tip clearance where the beneficial effect of the impeller-diffuser interaction on the impeller performance is at a maximum. A flow feature that consists of tip flow back leakage was shown to occur at design speed for the centrifugal compressor stage. This flow phenomenon is described as tip flow that originates in one passage, flows downstream of the impeller trailing edge and then returns to upstream of the impeller trailing edge of a neighboring passage. Such a flow feature is a source of loss in the impeller. A hypothesis is put forth to show that changing the diffuser vane count and changing impeller-diffuser gap has an analogous effect on the impeller performance. The centrifugal compressor stage was analyzed using diffusers of different vane counts, producing an impeller performance trend similar to that when the impeller-diffuser gap was varied, thus supporting the hypothesis made. This has the implication that the effect impeller performance associated with changing the impeller-diffuser gap and changing diffuser vane count can be described by the non-dimensional ratio of impeller-diffuser gap to diffuser vane pitch. A procedure is proposed and developed for isolating impeller passage blockage change without the need to define the region of blockage generation (which may incur a certain degree of arbitrariness). This method has been assessed for its applicability and utility.

Tan, Choon S.↗

Cycle-powered short radius (1.9M) centrifuge: exercise vs. passive acceleration

A human-powered short-arm centrifuge is described. This centrifuge could be used during spaceflight to provide +Gz acceleration while subjects performed exercise, thus supplying two forms of weightlessness countermeasures. Results from a study of cardiovascular responses while using the centrifuge are presented.

NASA Center ARC↗