Search NASA⌕ Search

SEARCH · Search NASA

Results for “CESIUM VAPOR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Trigger, an active release experiment that stimulated auroral particle precipitation and wave emissions

The experimental design by which a cesium vapor cloud was suddenly released in order to stimulate auroral particle precipitation is described along with the general results obtained. A drastic increase of the field-aligned charged-particle flux was observed with subsequent particle bursts. It is suggested that low-energy acceleration was due to parallel electric fields created by an instability which was driven by field-aligned currents resulting from the plasma injection. Pitch angle scattering in the deep magnetosphere may account for particle precipitation continuing for 130 sec after release.

Holmgren, G.↗

Early results from Magsat

Papers presented at the May 27, 1981 meeting of the American Geophysical Union concerning early results from the Magsat satellite program, which was designed to study the near-earth magnetic fields originating in the core and lithosphere, are discussed. The satellite was launched on October 30, 1979 into a sun-synchronous (twilight) orbit, and re-entered the atmosphere on June 11, 1980. Instruments carried included a cesium vapor magnetometer to measure field magnitudes, a fluxgate magnetometer to measure field components and an optical system to measure fluxgate magnetometer orientation. Early results concerned spherical harmonic models, fields due to ionospheric and magnetospheric currents, the identification and interpretation of fields from lithospheric sources. The preliminary results confirm the possibility of separating the measured field into core, crustal and external components, and represent significant developments in analytical techniques in main-field modelling and the physics of the field sources.

Langel, R. A.↗

Towards a high-temperature solar electric converter

The concept of an ultrahigh-temperature solar electric heat-engine converter is examined in which an alkali plasma would serve as both the high-temperature collector of solar radiation and as the working fluid for a high-temperature working cycle. The working cycle would be a simple magnetohydrodynamic Rankine cycle. Theoretical and experimental results obtained to date are summarized. These include: (1) an experimental confirmation of the theoretical prediction that a plasma temperature of about 2800 K can be reached through heating cesium vapor by sunlight concentrated to approximately 300 W per sq cm; and (2) the establishment of a theoretical model of the complete solar heated plasma magnetohydrodynamic cycle.

Dunning, G. J.↗

The Magsat mission

The cesium-vapor scalar and fluxgate vector magnetometers aboard the Magsat spacecraft, which has a twilight, sun-synchronous orbit with a 96.76-deg inclination, have together measured the earth's magnetic field magnitude to accuracies better than 2 nT, and the magnitude of each field component to better than 6 nT. The magnetometers are located at the end of a boom to isolate them from the effects of spacecraft fields, and an optical system was used to measure the attitude of the vector magnetometer and sun sensor at the boom relative to the two star cameras of the main spacecraft structure. The data gathered is available from the National Space Science Data Center in several formats and is currently undergoing analysis. Scalar and vector error budget values are given for the spacecraft's five error sources, which include the instrument, position and time errors, digitization noise, attitude errors, and spacecraft fields.

Langel, R.↗

Status of thermoelectronic laser energy conversion, TELEC

A concept known as a thermo-electronic laser energy converter (TELEC), was studied as a method of converting a 10.6 micron CO2 laser beam into electric power. The calculated characteristics of a TELEC seem to be well matched to the requirements of a spacecraft laser energy conversion system. The TELEC is a high power density plasma device which absorbs an intense laser beam by inverse bremsstrahlung with the plasma electrons. In the TELEC process, electromagnetic radiation is absorbed directly in the plasma electrons producing a high electron temperature. The energetic electrons diffuse out of the plasma striking two electrodes which are in contact with the plasma at the boundaries. These two electrodes have different areas: the larger one is designated as the collector, the smaller one is designated as the emitter. The smaller electrode functions as an electron emitter provide continuity of the current. Waste heat is rejected from the collector electrode. An experiment was carried out with a high power laser using a cesium vapor TELEC cell with 30 cm active length. Laser supported plasma were produced in the TELEC device during a number of laser runs over a period of several days. Electric power from the TELEC was observed with currents in the range of several amperes and output potentials of less than 1 volt.

Britt, E. J.↗

Magsat data availability

It is pointed out that a new era in near-earth magnetic field measurements began with NASA's launch of Magsat in October 1979 into a twilight, sun-synchronous orbit with 96.76 deg inclination, 561-km apogee, and 352-km perigee. A cesium vapor and a fluxgate magnetometer were employed to measure the magnetic field. A measurement of the spacecraft attitude to 20 arcseconds was required to achieve 6 nT (nanotesla) accuracy in the component measurements. This was accomplished with the aid of two star cameras on board the spacecraft and a sun sensor attached to the vector magnetometer. Magsat remained in orbit until June 11, 1980. Magsat has conducted the first truly global geomagnetic survey since the studies performed by the Polar Orbiting Geophysical Observatory (POGO) satellites. A global vector survey was provided of the main geopotential field and lower altitude measurements of crustal anomalies were conducted. Details concerning the availability of these data are discussed.

Langel, R. A.↗

Closed cycle MHD power generation experiments in the NASA Lewis Facility

Many modifications were made in the MHD facility. These include a redesign of the MHD duct interior, addition of mixing bars, increased electrical isolation of all the high temperature components from each other and from ground, and experimentation with various cesium seed vaporization and injection techniques. With the exception of the cesium system which needs further improvement the above modifications were quite successful and resulted in improvements in generator performance. The facility was run for a total of 400 hours in the past year, with 70 hours of this operation at temperatures of 2000 K or more with hot generator walls. With the exception of replacing one cracked brick in the MHD channel no repairs were required in the high temperature loop components for the duration of these tests. Uniform Faraday and Hall voltage profiles were obtained and the Faraday open circuit voltage varied from 90 to 100 percent of the ideal uBh. The magnitudes of the measured parameters are: Faraday open circuit voltage approximately 70 V, total Faraday current approximately 20 A, Hall voltage approximately 250 V, power output approximately 300 W, and power density .036 W/cu cm.

Sovie, R. J.↗

Closed cycle MHD power generation experiments in the NASA Lewis facility

Discussion of the performance improvements achieved through some modifications made in the closed cycle MHD facility. These modifications include a redesign of the MHD duct interior, addition of mixing bars, increased electrical isolation, and experimentation with various cesium seed vaporization and injection techniques. Uniform Faraday and Hall voltage profiles were obtained, and the Faraday open circuit voltage varied from 90 to 100% of the ideal uBh.

Sovie, R. J.↗

A shock tube study of line broadening in a temperature range of 6100 to 8300 K

Line widths of the Ca(II) 3968 A and Na(I) 5890 A resonance lines broadened by electric microfields in a plasma were measured. A pressure-driven shock tube was used as the light source. Radiation from the equilibrium region behind the reflected shock wave was studied using a rapid scanning Fabry-Perot interferometer. Electron and argon atom densities of about 8 x 10 to the 16th and 1 x 10 to the 19th/cu cm, respectively, were achieved at the relatively low temperature of around 7500 K by vaporizing a cesium powder that had been added to the shock tube as a solid aerosol in argon gas. The measured line widths were predominantly Stark broadened by the electrons and ions in the plasma, although Doppler, van der Waals, instrument function and optical depth effects had to be taken into account.

Baur, J. F.↗

Frequency standards for VLBI, present and future

During the last several years, J.P.L. has evaluated a number of different types of frequency standards. These evaluations include measurement of environmetal susceptibilities (barometric pressure, humidity, temperature and magnetic field) and evaluation of stability. Data from these tests are presented for quartz oscillators, rubidium vapor standards, cesium beam standards, hydrogen masers (active and passive) and a superconducting cavity stabilized oscillator. Data on reliability and mechanical ruggedness based on actual field use is also presented. A survey of new frequency standards, their likely performance and environmental characteristics is presented.

Sydnor, R. L.↗