Assessment of Sodium Thermal Stratification Models Utilizing the TSTF Benchmark

As a result of certain transient scenarios, a thermally stratified layer of liquid sodium can develop in the bulk coolant volumes of a sodium-cooled fast reactor (SFR). In addition to the effects a stratification layer has on the temperature of the heat transport system, a stratification layer can also influence the transition to and establishment of natural circulation flow, which plays an important role in passive cooling and the inherent safety of a pool-type SFR. Therefore, the ability to accurately capture thermal stratification phenomena is important when demonstrating the safety basis of a pool-type SFR during transient sequences. The present work assesses various computational models with different fidelities in their ability to predict thermal stratification in the upper plenum of an SFR. Each computational model will be assessed using the data generated at the Thermal Stratification Test Facility (TSTF) located at the University of Wisconsin-Madison. Using measured flow rate and inlet temperature data, the measured temperature distributions of the tests are compared to the predictions of the lumped volume-based models in SAS4A/SASSYS-1, a 1D-based model in SAM, and a 3-D computational fluid dynamics (CFD) model using STAR-CCM+. The relative performance of the various computational methods is assessed with respect to key metrics such as bulk coolant temperature distribution and plenum exit temperature. A total of eight tests are analyzed, covering different combinations of flow rates (3 and 10 GPM) and upper internal structure (UIS) configurations (none, solid, porous, and open) The perfect mixing model of SAS4A/SASSYS-1 provides the highest accuracy when the flow rate is high and there is no UIS in the test vessel, as high flow rate injection promotes thermal mixing of the sodium in the test vessel. For most of the analyzed tests, the stratified volume model of SAS4A/SASSYS-1 is able to predict the delay in the outlet temperature drop and temperature distribution in the test vessel by a small number of layers to represent thermal stratification. However, the stratified volume model can only simulate a maximum of three temperature layers within a volume and when a layer approaches the elevation of the outlet, the predicted outlet temperature can demonstrate rapid, non-physical changes. The 1-D axial mixing model of SAM provides results that agree reasonably well with the measured data in the prediction of the temporal evolution of the outlet temperature with the exception of the case with a high flow rate and no UIS. The SAM 1-D model has a similar level of accuracy to CFD results when it comes to predicting the outlet temperature. CFD shows overall good agreement in predicting the temperature distribution in the test vessel and outlet temperature. As CFD can model the test vessel geometry in detail, it performs well in the cases of complex geometries such as tests that included a UIS and internal flow through the UIS resulting in active mixing of the coolant in the test vessel. Each of the models discussed in the present work has the potential to be useful during the various stages of reactor design, analysis, and licensing. The lumped-volume approach can be applied for fast turnaround safety calculations to obtain overall reactor behavior during transients. The 1-D models provide improved accuracy when stratification is expected for a relatively low increase in the computational cost. The CFD model can be utilized for confirmatory analysis of the 1-D model, when experimental measurements are not available.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

CFD modeling and simulation for corrosive wear of refractory in molten slag

The development of high-wear resistant refractories having minimal production costs is facilitated by characterizing the wear mechanisms associated with their corrosive wear. Static cup testing is a commonly used method for comparing the corrosion resistance performance of two or more refractory materials. Although the static cup test conditions are not as severe as dynamic tests, this study shows that the thermal gradient present within the system during heating and cooling stages serves to generate movement of the slag leading to mechanical wear. The thermal gradient within the refractory, and between the slag and the refractory, occurs during the ramp stage of the test and lasts until the soaking stage is reached bringing the system to a thermal equilibrium. Using computational fluid dynamics (CFD) capabilities embedded within ANSYS software, this study modelled and quantified the convection currents within the slag and associated shear stresses generated on the refractory walls due to the thermal gradient. A traditional ladle furnace was employed as a case study to verify the results of the studied CFD model. The corrosion rate of the refractory lining was found to depend on the mass transfer coefficient of the refractory dissolution into the slag, and a velocity term which governs the extent of corrosion at any given location. This velocity term is a function of slag viscosity, as well as the concentration gradient and/or temperature gradient at the triple points. In this study, wall shear stress was used as a reliable proxy for identifying high-velocity regions prone to excessive corrosive wear. Elevated wall shear stress near the slag/air and slag/molten steel interfaces align with observed corrosion grooves, which reflects the intensified corrosive wear at these locations.

Ramteke, Rajat Rajat Durgesh Ramteke [University o↗

CFD-trained ANN Model for Approximating Near-occupant Condition in Real-time Simulations

The main drawback of Computational Fluid Dynamics (CFD) simulations has been the time and resource consuming nature which is not suitable for real-time applications. In this work, we first generated numerous CFD models of a given indoor space to obtain airspeed, temperature, and mean radiant temperature near an occupant as training data. Several artificial neural networks (ANN) models were trained using this CFD simulated data to approximate near real-time environmental conditions for a given occupant. This trained ANN model approach is a part of a real-time simulation of building operations using a combination of software and real hardware (HVAC equipment) approaches. The preliminary results suggest that the CFD- generated training data and the trained ANN model can accurately approximate such conditions in a real-time application, a method that has great potential in building simulation and building digital twin areas of research.

Zhang, Yun↗

A whole-core steady-state thermal-hydraulic model for annular fuel type fluoride-salt-cooled reactors

A whole-core, steady-state thermal-hydraulic model is developed for the fluoride-salt-cooled small modular advanced high-temperature reactor (SmAHTR) that employs an annular fuel configuration. This pre-conceptual reactor design by Oak Ridge National Laboratory (ORNL) has the annular fuel and moderator pins arranged in a hexagonal layout. The FLiBe coolant flows from the bottom to the top of the core, parallel to the hexagonal bundle. The fuel and moderator pins in the core are discretized into finite volumes and the 3-D heat conduction equation is solved to obtain the temperature profile. Inter-fuel assembly conduction is also addressed. For this fuel assembly configuration, the coolant flows through two distinct regions – the hexagonal pin bundle and the annulus between the fuel pin and the tie rod. The fluid flow through the hexagonal bundles is modeled using the subchannel approach, in which the coolant region is discretized into corner, edge and interior subchannels and the resulting conservation equations are systematically solved. The 1-D mass, momentum and energy equations are solved for the annulus channels between the fuel pin and the tie rod. Pertinent closure models from the literature are employed to close the system of equations. We also performed a preliminary code-to-code comparison between the present model and a CFD model.. The resulting thermal-hydraulic model can provide temperature, flow rate and pressure drop profiles for the different solid and fluid regions throughout the entire core. Whole-core thermal-hydraulic results for a representative power profile are presented and discussed.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Non-Idealities in Lab-Scale Kinetic Testing: A Theoretical Study of a Modular Temkin Reactor

The Temkin reactor can be applied for industrial relevant catalyst testing with unmodified catalyst particles. It was assumed in the literature that this reactor behaves as a cascade of continuously stirred tank reactors (CSTR). However, this assumption was based only on outlet gas composition or inert residence time distribution measurements. The present work theoretically investigates the catalytic CO2 methanation as a test case on different catalyst geometries, a sphere, and a ring, inside a single Temkin reaction chamber under isothermal conditions. Axial gas-phase species profiles from detailed computational fluid dynamics (CFD) are compared with a CSTR and 1D plug-flow reactor (PFR) model using a sophisticated microkinetic model. In addition, a 1D chemical reactor network (CRN) model was developed, and model parameters were adjusted based on the CFD simulations. Whereas the ideal reactor models overpredict the axial product concentrations, the CRN model results agree well with the CFD simulations, especially under low to medium flow rates. This study shows that complex flow patterns greatly influence species fields inside the Temkin reactor. Although residence time measurements suggest CSTR-like behavior, the reactive flow cannot be described by either a CSTR or PFR model but with the developed CRN model.

Wehinger, Gregor D. (ORCID:0000000217743391)↗

Assessment of Thermal Stratification in Versatile Test Reactor Transients

The Versatile Test Reactor (VTR) is a fast-spectrum test reactor currently being developed in the United States under the direction of the US Department of Energy. The conceptual design of the 300 MWth pool-type sodium-cooled fast reactor (SFR) has been led by the US National Laboratories in collaboration with General Electric-Hitachi and Bechtel National Inc. Safety performance analysis for the VTR conceptual design is being performed with the systems thermal-hydraulics (SYSTH) module of the SAS4A/SASSYS-1 liquid-metal reactor safety analysis code system. Since the current model of the VTR employs a simple perfect mixing model for large plena like the hot pool, it is not able to predict temperature variations that may develop during the transient. Prior work simulating the response of SFRs to postulated events like the Protected Station Blackout (PSBO) has shown that the phenomenon of thermal stratification, where stable thermal layers accumulate in the hot pool, may delay the transition to natural circulation and thus impact the predicted transient progression. Thus, an effort has begun to model this transient by integrating a Computational Fluid Dynamics (CFD) model of the hot pool into the SAS4A/SASSYS-1 model of the Primary Heat Transport System during the simulation of the PSBO event. A three-dimensional Volume-Of-Fluid CFD model of the VTR hot pool has been developed for the co-simulation of SAS4A/SASSYS-1 with CFD. In this work, the standalone SAS4A/SASSYS-1 calculation and the standalone CFD calculation based on the SAS4A/SASSYS-1 calculation result were produced on the Idaho National Laboratory High Performance Computing cluster, SAWTOOTH. At this time, only the standalone CFD and SAS4A/SASYS-1 simulation results are provided.

99 GENERAL AND MISCELLANEOUS↗

Solid–liquid separation of lignocellulosic sugars from biomass by rotating ceramic disc filtration

In many biomass conversion processes, the separation of cellulosic sugars from residual, lignin-rich solids is a critical step, and achieving high recovery yields of sugars by conventional tangential crossflow and vacuum filtration is challenged by the presence of biomass solids, which rapidly foul filters, resulting in decreased throughput. Considering the performance limitations of traditional filtration methods, dynamic filtration, which generates high shear at the membrane surface to decrease fouling, is emerging as a viable alternative for demanding solid–liquid separations. For high solids separations, there is little available information regarding the performance, limitations, and energy consumption of dynamic filtration. To that end, here we characterized the performance of a dynamic filtration module, specifically a rotating ceramic disc (RCD) filter, for the aseptic recovery of cellulosic sugars from biomass solids following pretreatment and enzymatic hydrolysis. We show how RCD rotational velocity and percent biomass solids impact the filter throughput. Additionally, we used computational fluid dynamics (CFD) simulations to estimate the shear rate at the membrane surface and to visualize hydrodynamic profiles within the module. With the combined CFD simulations and experimental results, we estimated the energy demand and operating expenses for a viable dynamic filtration system operating with a lignocellulosic feed slurry. Our results indicate that an RCD filter can achieve ≥95% recovery of sugars and produce a retentate slurry containing 12 wt% insoluble solids with low energy consumption (a 2.2-fold improvement over cross-flow filtration) and low operating costs ($\$$0.06 per kg sugars). These results show a viable path towards operationally reliable, energy efficient, and cost-effective separations of sterilized cellulosic sugars from biomass solids and highlight the potential of dynamic filtration systems for challenging solid–liquid separations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Co-optimized Mixed-Mode Engine and Fuel Demonstrator for Improved Fuel Economy while Meeting Emissions Requirements

Progressively increasing regulatory demands on fuel economy and future global emission standards have led to a focus on advanced engine development to improve overall engine efficiency and fulfill emission requirements. Low temperature combustion (LTC) and gasoline compression ignition (GCI) are promising technologies to achieve these goals and have the advantage of using existing refinery infrastructure and subsequent economies of scale for a robust energy supply. By applying spark ignition (SI) for cold start, LTC for low load operations, and GCI for medium to high load operations, a multimode GCI engine concept was proposed and the fuel formation was co-optimized to maximize fuel economy improvement potential while maintaining ULEV 70 emissions standards. HATCI has successfully demonstrated the feasibility of this multimode GCI engine concept, and confirmed the fuel economy improvement over the baseline SI engine by simulating the FTP75 vehicle drive cycle. In this report, the technical approaches, multimode engine control, and engine test results of both steady state and transitions, CFD modeling, fuel testing, and FTP75 drive cycle simulation results are summarized, followed with technical challenges observed, and recommendations for possible follow-up studies.

02 PETROLEUM↗

Visualization of post-detonation fireball flowfields and comparison to CFD modeling

Visualization of flow structures within post-detonation fireballs has been performed for benchmark validation of numerical simulations. Custom pressed PETN explosives with a 12-mm diameter hemispherical form factor were used to produce a spherically symmetric post-detonation flow with low soot yield. Hydroxyl-radical planar laser induce fluorescence (OH-PLIF) was employed to visualize the structure ranging from approximately 10 μs to 35 μs after shock breakout from the explosive pellet. Fireball simulations were performed using the HyBurn Computational Fluid Dynamics (CFD) package. Experimental OH-PLIF results were compared to synthetic OH-PLIF from post-processing of CFD simulations. From the comparison of experimental and synthetic OH-PLIF images, CFD is shown to replicate much of the flow structure observed in the experiments, revealing potential differences in turbulent length scales and OH kinetics. Furthermore, results provide significant advancement in experimental resolution of these harsh turbulent combustion environments and validate physical models thereof.

Detonator↗

Involute Working Group – Validation of CFD Turbulence Models for Steady-State Safety Analysis

There are three research reactors in the world having fuel plates curved as circle-involute (a spiral generated around a circle): The Oak Ridge National Laboratory (ORNL) High Flux Isotope Reactor (HFIR) located in Tennessee, U.S.A. [ORNL, 2018]; The Laue-Langevin Institute (ILL) High Flux Reactor (RHF) located in Grenoble, France [ILL, 2018]; and, The Technical University of Munich (TUM) Research Neutron Source Heinz Maier-Leibnitz (FRM II) located in Garching, Germany [TUM, 2018]. All three reactors are currently using Highly Enriched Uranium (HEU, 235U/U ≥ 20 wt. %) as fuel and all three are actively engaged in activities to convert to Low Enriched Uranium (LEU, 235U/U < 20 wt. %) fuel. More information on these reactors can be found in Section two. For various reasons, these reactors have expressed interest in using Computational Fluid Dynamics (CFD) tools to perform their Steady-State Thermal-Hydraulic (SSTH) safety calculations. Using CFD tools for SSTH analysis represents generally a significant departure from traditional methods and requires thorough verification and validation (V&V) to be accepted by regulators. This is why Argonne National Laboratory (ANL) and the involute reactors formed an informal group to help each other in this endeavor. This so-called Involute Working Group (IWG) aims at supporting the qualification of CFD tools for SSTH safety calculations. Activities include benchmarking, code-to-code comparison, Verification and Validation (V&V) as well as technical support. More information on the IWG and the reasons why involute-plate reactors are interested in CFD can be found in Section three. The present study aims at testing three turbulence models commonly implemented in commercial software (namely K-Epsilon, K-Omega and Reynolds-Stress) and assessing their relevance for involute-plate reactor application. An experiment performed by Gambill and Bundy in 1961 was performed to measure heat transfer coefficients in conditions prototypic of the HFIR reactor [Gambill, 1961]. More details on this experiment are provided in Section four. Based on the information available, CFD models of this experiment have been created and the experimental results have been compared to the ones obtained with these CFD models. CFD models and the results of this comparison are provided in Section five.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Mild hybridisation of turboprop engine with high-power-density integrated electric drives

Here this paper shares with the aerospace community a case study of turboprop mild hybridisation using a recently developed integrated drive system in the University of Nottingham, UK, within the ACHIEVE project under EU H2020 CleanSky 2 program (project No. 737814). The developed drive system enables green taxiing of a turboprop aircraft while on the ground with its engine off, and as an electrical generator when the turboprop is in the air. The entire system is designed to be able to integrate within the power auxiliary gear box (PAGB) of a turboprop aircraft. Some of the key features of the developed system include a high-speed permanent magnet machine (up to 14,200rpm) with dual three-phase design, SiC-based high power density (11.8kW/L for the power converter, 35.3kW/L and 7.2kW/kg for the machine active parts), integrated cooling design for high-temperature operation (>130°C ambient temperature), fault tolerance consideration with dual channel operation capabilities and sensorless control for entire operational conditions. This paper is giving an overview of the design process of the electrical machine, power converters, and its cooling of the entire drive. Numerical analysis (FEM and CFD) and some experimental results are presented to demonstrate the effectiveness and the desired performance of the developed integrated drive system.

42 ENGINEERING↗

Effect of the J-Shaped Wind Turbine Airfoil Opening Ratio and Thickness on the Performance of Symmetrical Airfoils

Abstract In this work, the effect of the inner opening ratio on the J-shaped airfoils aerodynamic performance was studied and documented for symmetrical airfoils. Three different airfoil thicknesses were investigated: small (NACA0008), medium (NACA0015), and large (NACA0024). For each airfoil thickness, effects of three inner opening ratios were analyzed: one-third, one-half, and two-thirds. The performance of each opening ratio was compared with the performance of the solid airfoil “zero opening ratio” for different angles of attack between 5 deg and 20 deg. All designs were simulated using the computational fluid dynamics (CFD) technology against experimental results for solid NACA4412 airfoil in the University of Wisconsin-Milwaukee (UWM) wind tunnel facility and other published experimental data. It was found that large eddy simulation yields accurate solutions with a smaller number of mesh cells compared to the k–ω turbulence model but with much longer computational time. The lift-to-drag ratio for all studied airfoils has a maximum value for solid airfoils compared to those equipped with openings. For airfoils equipped with 00.00% opening ratio “solid,” NACA0015 airfoil has the maximum lift-to-drag ratio. Furthermore, it was found that NACA0008 equipped with a 33.33% opening ratio has the best performance of all studied J-shaped airfoils.

Energy & Fuels↗

Coupling a Lagrangian–Eulerian Spark-Ignition (LESI) model with LES combustion models for engine simulations

In the United States transportation sector, Light-Duty Vehicles (LDVs) are the largest energy consumers and CO 2 emitters. Electrification of LDVs is posed as a potential solution, but SI engines can still contribute to decarbonization. Car manufacturers have turned to unconventional engine operation to increase the efficiency of Spark-Ignition (SI) engines and reduce the carbon emissions of their fleets. Dilute, lean, and stratified-charge engine operation has the potential for engine efficiency improvements at the expense of increased cyclic variability and combustion instability. At such demanding engine conditions, the spark ignition event is key for flame initiation and propagation and for enhanced combustion stability. Reliable and accurate spark ignition models can help design ignition systems that reduce cyclic variability. Multiple computational spark-ignition models exist that perform well under conventional conditions, but the underlying physics needs to be expanded, for unconventional engine operation. In this paper, a hybrid Lagrangian–Eulerian Spark-Ignition (LESI) model is coupled with different turbulent flame propagation models for engine simulations. LESI relies on Lagrangian arc tracking and Eulerian energy deposition. The LESI model is coupled with the Well-Stirred Reactor (WSR), Thickened Flame Model (TFM), and g-equation model and used to simulate several cycles of a Direct-Injection Spark-Ignition (DISI) engine using a commercial Computational Fluid Dynamics (CFD) engine solver. The results showcase the successful coupling of LESI with the combustion models. Global engine metrics, such as pressure and Apparent Heat Release Rate (AHRR), for each simulation setup are compared to experimental engine results, for validation. In addition, results highlight the successful prediction of spark channel movement by comparing simulation images to experimental optical engine images. Finally, the successful coupling of LESI to combustion models, making it a usable model in the engine modeling community, is emphasized and future development details are discussed.

33 ADVANCED PROPULSION SYSTEMS↗

Assessing the Impact of a Novel TBC Material on Heat Transfer in a Spark Ignition Engine through 3D CFD-FEA Co-Simulation Routine

Thermal barrier coatings (TBCs) have been of interest since the 1970s for application in internal combustion (IC) engines. Thin TBCs exhibit a temperature swing phenomenon wherein wall temperatures dynamically respond to the transient working-gas temperature throughout the engine cycle, thus reducing the temperature difference driving the heat transfer. Determining these varying wall temperatures is necessary to evaluate and study the effect of coatings on wall heat transfer. This study focuses on developing a 3D computational fluid dynamics (CFD)-finite element analysis (FEA) coupled simulation, or co-simulation, routine to determine the wall temperatures of a piston coated with a thin TBC layer subject to spark ignition combustion heat flux. A CONVERGE 3D-CFD model was used to simulate the combustion process in a single-cylinder, light-duty experimental spark ignition (SI) engine. Transient piston heat transfer analysis was conducted using ABAQUS, a FEA package, under the simulated combustion heat flux load. The effect of the temperature swing phenomenon due to this TBC layer was observed in a CFD simulation by implementing the FEA results as the piston thermal boundary conditions. The boundary conditions were passed between the CFD and FEA tools until a quasi-steady state solution was achieved. Furthermore, a reduction in wall heat transfer was observed due to a reduced temperature difference between the wall and the working gas.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Preliminary Modeling of Triply Periodic Minimal Surface (TPMS) Structures with RELAP5-3D

This poster goes over preliminary work performed on modeling triply periodic minimal surfaces (TPMS) with RELAP5-3D. The poster starts off with the need for advanced nuclear fuel designs for future reactors, and how TPMS are being researched for this purpose. There is then a focus on what a TPMS is and then moves onto the motivation for why this geometry is being modeled and looked into. The methodology is then shown for how data from different experiments will be used for pre-test predictions and eventual creation of empirical coefficients and multipliers to be used in models. Then there is a show of how data would be compared between the experimental tests, CFD, and RELAP5-3D values. The results from the simulations and comparisons are then presented to show how the CFD and RELAP5-3D compare to each other currently, with no experimental data to compare to for one test model. Results from the second test model are also presented to show that there is stability in the solving of that model.

42 - ENGINEERING↗

Assessment of the 3420 Building Filtered Exhaust Stack Sampling Probe Location: Stack Verification Following Fan and Air Blender Additions

The Pacific Northwest National Laboratory (PNNL) 3420 Building, which is part of the Physical Sciences Facility (PSF), houses radiological capabilities that results in the requirement that emissions monitoring must be conducted for potential radionuclides in the exhaust air discharge of this building. The air monitoring system is required to conform to Title 40 of the Code of Federal Regulations part 61 (40 CFR 61) Subpart H, which in turns requires a sampling probe in the exhaust stream to conform to the criteria of American National Standards Institute / Health Physics Society (ANSI/HPS) N13.1-2011, Sampling and Monitoring Releases of Airborne Radioactive Substances from the Stack and Ducts of Nuclear Facilities. To support the air emissions permit for the 3420 Building on the PNNL campus, stack testing that used computational fluid dynamics (CFD) modeling as a surrogate stack and verification tests of velocity uniformity and flow angle on the retrofitted facility stack was performed. The ANSI/HPS N13.1-2011 criteria for the air monitoring probe location are that velocity uniformity, gaseous tracer uniformity, and particulate tracer uniformity must be less than or equal to 20%COV. Furthermore, no point in the sampling location may have a gaseous tracer concentration that varies from the mean concentration by more than 30%. Additionally, the flow angle at the sampling location must not be more than 20°. The CFD modeling of the stack, as reported by Recknagle et al. (2018) demonstrated that the stack meets the criteria at the probe location. The velocity uniformity and flow angle results from the 3420 stack verification tests, performed in October 2020, demonstrated that the CFD model results may be used to support the qualification of the stack sampling location. The measured velocity uniformity verification test result was 1.4%COV. This value is well within the uniformity criterion, which is that the velocity uniformity be =20%COV. Additionally, this value is well within the criterion that the actual stack measurement must be within 5% of the surrogate stack result of 2.1%COV when all four fans were operating. Additionally, the measured average flow angle at the 3420 stack monitor location was 15.5 degrees. Although this is higher than expected based on the CFD model, the result is =20 degrees, so the criterion is met. Based on these stack verification test results, the reconfigured 3420 Building filtered exhaust stack meets the qualification criteria given in the ANSI/HPS N13.1-2011 standard. Further changes to the system configuration or operating conditions that are outside the bounds described in this and the CFD report (Recknagle et al., 2018) may require additional tests and additional analysis to determine compliance with the standard.

3420 Building↗

A multiphase flow model of water droplets dielectrophoretic-induced air dehumidification phenomena

Air humidity in indoor spaces plays a critical role in human comfort and health. Dehumidification systems are used for building humidity controls, but they can take significant energy consumption, especially in geographic locations with high outdoor humidity and warm climates. Consequently, there is a growing demand for innovative dehumidification processes that consume minimal energy. Dielectrophoretic air dehumidification represents one such promising approach. However, it has not garnered significant attention due to the absence of engineering models and simulation tools capable of evaluating its performance and limitations at large-scale airflows. A new numerical multiphase CFD model, which is also experimentally validated, is developed in a customized Reacting Foam solver based on OpenFOAM® version 9. The newly developed model seeks to decrease substantial energy consumption and lower costs by leveraging the dielectrophoretic phenomenon to regulate moisture levels in the air. The solver integrates a hybrid Eulerian-Lagrangian framework to track the droplet's trajectory and growth rate while solving the continuum equations for the moist air. An electrospray produces electrically charged droplets, which grow during their in-flight trajectories as water vapor condenses onto their surfaces. The role of electrostatic forces in promoting vapor condensation within a high-gradient electrical field is investigated, and the dielectrophoretic vapor nucleation process on charged water droplets is discussed. The CFD model was validated against results from the literature and from proof-of-concept experiments conducted by the authors, which showed a 2 % air dehumidification with a single electrospray and airflow rate of 5 cubic feet per minute. The simulation results indicated that augmenting the number of electrically charged spray droplets increased the dehumidification of the air to 25 %. The initial mean droplet diameter, the orientation of the injector and relative humidity significantly influence the assessment of dehumidification. As a result, scaling up this approach to larger airflow volumes is identified as a potential future research direction.

42 ENGINEERING↗

Prototype Modeling for a Light-Trapping Planar-Cavity Enclosed Particle Solar Receiver

Concentrating solar thermal (CST) systems present a promising avenue for affordable and reliable energy production. Solar receivers are key components that determine the efficiency and longevity of these systems. Particle-based solar receivers have emerged as a compelling alternative to traditional technologies, offering several advantages that address limitations in current CST systems. This is especially true as next-generation CST technologies target applications including electricity generation, thermochemical processes, and industrial process heat, many of which necessitate higher operating temperatures than current commercial molten salt systems. Molten-salt thermal energy storage (TES) systems, commonly used in CSP, face challenges related to freezing and corrosion. Particle-based TES systems, in contrast, do not experience these issues, as particles are stable at high temperatures, exceeding 1000 degrees Celsius. This capability allows for a wider range of applications, including those requiring higher temperatures for industrial processes and efficient electricity generation. A novel innovation in particle-based solar receiver technology is the light-trapping planar cavity receiver (LTPCR) configuration developed by NREL. The LTPCR design consists of small cavity-like structures using opaque planar surfaces, enabling efficient capture and absorption of solar energy. A high incident flux concentration at the cavity aperture is absorbed on the receiver walls, and subsequently transferred to particles on the inside of cavities. The particles flow through the system, forming a fluidized bed inside of the receiver panels, effectively capturing the absorbed solar heat. Air is used as a fluidizing medium in this process to enhance particle heat transfer and mixing. The effectiveness of this design lies in its ability to manage solar flux conditions and ensure high solar-to-thermal receiver efficiency. A 100-kW prototype is currently being tested at the King Saud University in Saudi Arabia to assess the receiver performance. A range of modeling analyses for the optical, thermal, and mechanical effects were conducted to assess the performance of the receiver under on-sun conditions. The solar flux resulting from the KSU heliostat field was modeled using NREL SolTrace software and produced up to 600 kW/m2 at the receiver aperture. The solar flux absorbed on the receiver walls was then used within a computational fluid dynamics (CFD) model to predict wall temperature distributions along with radiation and convection loss. A two-phase CFD model was developed for the fluidized bed of silica sand inside the receiver panels to predict local wall-to-particle heat transfer coefficients, particle temperature distributions, and outlet temperature of the particles. We have also conducted analyses to understand the thermomechanical behavior of these innovative enclosed light-trapping solar receivers optimized for particle heating. We used finite element analysis (FEA) to predict the receiver's performance using temperature distributions obtained from CFD and based on the resulting stress profiles, evaluated creep-fatigue damage with a goal of achieving a 30-year service life. Analysis showed a significant impact of the particle-to-wall heat transfer coefficients (HTCs) on receiver performance, with higher HTCs resulting in reduced stress and increased lifespan. For instance, when using Inconel 740H, increasing the HTC from 800 W/m2 K to 1400 W/m2 K increased the creep life from 4,000 hours to over 100,000 hours. This highlights the importance of understanding and optimizing heat transfer in the design of high-efficiency receivers.