Search NASA⌕ Search

SEARCH · Search NASA

Results for “CHIP”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Towards a Generic and Adaptive System-On-Chip Controller for Space Exploration Instrumentation

This paper introduces one of the first efforts conducted at NASA’s Jet Propulsion Laboratory (JPL) to develop a generic System-on-Chip (SoC) platform to control science instruments that are proposed for future NASA missions. The SoC platform is named APEX-SoC, where APEX stands for Advanced Processor for space Exploration, and is based on a hybrid Xilinx Zynq that combines an FPGA and an ARM Cortex-A9 dual-core processor on a single chip. The Zynq implements a generic and customizable on-chip infrastructure that can be reused with a variety of instruments, and it has been coupled with a set of off-chip components that are necessary to deal with the different instruments. We have taken JPL’s Compositional InfraRed Imaging Spectrometer (CIRIS), which is proposed for NASA icy moons missions, as a use-case scenario to demonstrate that the entire data processing, control and interface of an instrument can be implemented on a single device using the on-chip infrastructure described in this paper. We show that the performance results achieved in this preliminary version of the instrumentation controller are sufficient to fulfill the science requirements demanded to the CIRIS instrument in future NASA missions, such as Europa.

embedded system↗

NEPP Evaluation of Automotive Grade Tantalum Chip Capacitors

Automotive grade tantalum (Ta) chip capacitors are available at lower cost with smaller physical size and higher volumetric efficiency compared to military/space grade capacitors. Designers of high reliability aerospace and military systems would like to take advantage of these attributes while maintaining the high standards for long-term reliable operation they are accustomed to when selecting military-qualified established reliability tantalum chip capacitors (e.g., MIL-PRF-55365). The objective for this evaluation was to assess the long-term performance of off-the-shelf automotive grade Ta chip capacitors (i.e., manufacturer self-qualified per AEC Q-200). Two (2) lots of case size D manganese dioxide (MnO2) cathode Ta chip capacitors from 1 manufacturer were evaluated. The evaluation consisted of construction analysis, basic electrical parameter characterization, extended long-term (2000 hours) life testing and some accelerated stress testing. Tests and acceptance criteria were based upon manufacturer datasheets and the Automotive Electronics Council's AEC Q-200 qualification specification for passive electronic components. As-received a few capacitors were marginally above the specified tolerance for capacitance and ESR. X-ray inspection found that the anodes for some devices may not be properly aligned within the molded encapsulation leaving less than 1 mil thickness of the encapsulation. This evaluation found that the long-term life performance of automotive grade Ta chip capacitors is generally within specification limits suggesting these capacitors may be suitable for some space applications.

Automotive↗

Testing of the ISS’s Charcoal HEPA Integrated Particle Scrubber (CHIPS) Filters to Ascertain an Efficiency Curve and Most Penetrating Particle Size

High air quality is a top priority in hermetically sealed environments, such as the International Space Station (ISS). Aerosol particulate filtration on the ISS is achieved via 21 HEPA filters. Traditional HEPA filters have an efficiency of 99.97%, but HEPA filters aboard the ISS have been found to achieve 99.99% efficiency. This may be due to the flight-grade HEPA filters chosen or, less likely, that they are combined with activated charcoal filters for siloxane removal in a combination referred to as Charcoal HEPA Integrated Particle Scrubbers (CHIPS) filters. All filters have a Most Penetrating Particle Size (MPPS), but, until now, the MPPS and efficiency curve of the CHIPS filters was not known. The efficiency curve of the CHIPS filters was ascertained at NASA Glenn Research Center through standard salt crystal aerosolization. This method was selected over aerosolized oil droplets due to a desire to preserve the filter’s function for further testing. The CHIPS filters were tested as they are oriented on the ISS (activated charcoal filter followed by a flight-grade HEPA filter), with the HEPA portion alone, and with the activated charcoal portion alone. The results of this experiment are generally useful but can be especially useful for the microbiology and Environmental Control and Life Support Systems (ECLSS). This is due to microbial contamination being a potential concern in the air revitalization systems on the ISS. Knowing the MMPS of the CHIPS filters, in conjunction with levels of airborne microbes, is useful for predicting which and how many microbes are likely to get through the HEPA filters that sit in the beginning of the ISS airstream. It may also be useful to other groups at NASA to know how many particulates are able to pass through high-efficiency filtration, and even for healthcare cleanrooms and other air purification pursuits.

A Nicolas Whitlock↗

Simulating Alpha Particles Incident on MKID Chips for Quantum Sensitivity Analysis

Superconducting quantum devices, such as microwave kinetic inductance detectors (MKIDs), are highly sensitive instruments used in quantum computing and advanced sensing technologies. However, their extreme sensitivity also makes them vulnerable to background noise from natural sources like radiation. One significant contributor to this noise is alpha particles emitted by 210Po, a radon decay daughter that accumulates on surfaces near the detector. This project investigates how alpha particles emitted from 210Po interact with MKID chips. These particles can deposit energy on the detector surface, disrupting its operation and generating false signals. Understanding the energy and behavior of these particles is crucial for improving the design and reliability of quantum devices. To explore this, we first modeled the decay chain starting from 210Pb to 210Po using differential equations. This allowed us to predict how the activity of alpha-emitting isotopes changes over time, reaching a steady state after about two years. Next, we simulated alpha particle interactions with the MKID chip using the Geant4 software toolkit. We built a detailed computer model of the detector housing, including the copper lid where alpha particles originate, the silicon chip, and a thin aluminum sensor layer. Alpha particles were emitted isotropically from just beneath the copper lid’s surface, mimicking natural decay conditions. The simulation tracked how these particles deposit energy on the chip, generating electron-hole pairs and phonons. The results provide insight into the behavior of the resultant electron-hole pairs and phonons, giving us a clear understanding of the energy deposition distribution on the chip. This work supports efforts to mitigate background noise in superconducting sensors, advancing their use in quantum computing and sensitive physics experiments.

Hall, Matthew [Fermilab; UCLA]↗

Size, shape and flow characterization of ground wood chip and ground wood pellet particles

Size, shape and density of biomass particles influence their transportation, fluidization, rates of drying and thermal decomposition. Pelleting wood particles increases the particle density and reduces the variability of physical properties among biomass particles. In this study, pine chips prepared for pulping and commercially produced pine pellets were ground in a hammer mill using grinder screens of 3.2, 6.3, 12.7 and 25.4mmperforations. Pellets consumed about 7 times lower specific grinding energy than chips to produce the same size of particles. Grinding pellets produced the smaller particles with narrower size distribution than grinding chips. Derived shape factors in digital image analysis showed that chip particles were rectangular and had the aspect ratios about one third of pellet particles. Pellet particles were more circular shape. The mechanical sieving underestimated the actual particle size and did not represent the size of particles correctly. Instead, digital imaging is preferred. Angle of repose and compressibility tests represented the flow properties of ground particles. Pellet particles made a less compacted bulk, had lower cohesion and did flow easier in a pile of particles. In conclusion, particle shape affected the flow properties more than particle size

09 BIOMASS FUELS↗

Discrete element modeling of deformable pinewood chips in cyclic loading test

The design of efficient lignocellulosic biomass feedstock systems is challenging, as current laboratory characterization and design methods were developed primarily for fine powders with relatively low compressibility. Here, the discrete element method (DEM) is gaining prominence as an alternative method for modeling the bulk flow and transport of particulate materials in hoppers and feeders. However, prior DEM simulations investigating the flow of wood chips modeled the particles as simple rigid geometries such as spheres, rods or blocks, and neglected the effects of particle deformability and irregular shapes. As a consequence, those simplified DEM models may not provide enough key diagnosis to help improve the design of biomass feeding and handling equipment. This work presents a bonded-sphere DEM approach for characterizing the mechanical behavior of bulk flexible, deformable pinewood chips in a cyclic stress loading test. Clustered spheres that can bend and twist via elastic bonds are used to model irregular-shape particles in real pinewood chip samples. An axial compression tester, which contains 0.06 million bonded-sphere particles (1.35 million spheres) in a quarter cylinder, is simulated with a domain size similar to the experiments. With careful calibration, the simulations have delivered the bulk densities and the bulk moduli of elasticity that are in good agreement with those measured in the corresponding experiments. However, it is also been found challenging for the present DEM model to accurately predict the overall stress-strain behavior of bulk pinewood chips, especially the large sustained plastic deformation during unloading. Additional numerical tests have shown that the adjustment in certain contact parameters (e.g. bond stiffness) can lead to profound solution improvement, but meanwhile will induce extra challenges such as increased computing time. Future work will include an elasto-plastic particle bond model to enhance the simulation fidelity.

42 ENGINEERING↗

Open-systems Architecture of a Standardized Command Interface Chip-set for Switching and Control of a Spacecraft Power Bus

This viewgraph presentation reviews the architecture of the The CIA-AlA chip-set is a set of mixed-signal ASICs that provide a flexible high level interface between the spacecraft's command and data handling (C&DH) electronics and lower level functions in other spacecraft subsystems. Due to the open-systems architecture of the chip-set including an embedded micro-controller a variety of applications are possible. The chip-set was developed for the missions to the outer planets. The chips were developed to provide a single solution for both the switching and regulation of a spacecraft power bus. The Open-Systems Architecture allows for other powerful applications.

power switch slice (PSS)↗

Design and characterization of Ion sources for CHIP-TRAP

At Central Michigan University, we are developing a high-precision Penning trap mass spectrometer (CHIP-TRAP) for precise mass measurements with stable and long-lived isotopes. Ions will be produced using external ion sources and then transported to the Penning trap at low energy using electrostatic ion optics. Ion sources that will be utilized with CHIP-TRAP include a laser ablation ion source (LAS) that has already been commissioned, and a low current Penning ion trap (PIT) source that is currently being developed. The LAS enables ion production from solid targets via ablation and ionization with a high-powered laser pulse. The PIT source is a novel Penning ionization gauge (PIG) type source, consisting of a 0.55 T NdFeB ring magnet, cylindrical Penning trap, and low current thermal electron emitter that enables ion production via electron impact ionization of gaseous samples. For both ion sources, small bunches of ~100 – 1000 ions can be produced from a minimal sample of source material. Finally, the ion bunches are then transported along the CHIP-TRAP beamline, where time-of-flight mass filtering can be performed before they are captured in the CHIP-TRAP Penning traps.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A versatile and low-cost chip-to-world interface: enabling ICP-MS characterization of isotachophoretically separated lanthanides on a microfluidic device

Microfluidics offer novel and state-of-the-art pathways to process materials. Microfluidic systems drastically reduce timeframes and costs associated with traditional lab-scale efforts in the area of analytical sample preparations. The challenge arises in effectively connecting microfluidics to off-chip analysis tools to accurately characterize samples after treatment on-chip. Here, a fused silica microfluidic device (MFD) is connected to a fused-silica capillary in order to create a world-to-chip connection between the MFD and an inductively coupled plasma mass spectrometer (ICP-MS). Specifically, this is demonstrated by utilizing isotachophoresis (ITP) on a microfluidic chip to separate samples containing up to 14 lanthanides into elementally pure bands. The separated sample is successfully transferred across a 7 nL dead space at the microchip-capillary junction, such that separation resolution is maintained and even increased through the interface and into the ICP-MS, where the elemental composition of the separated sample is analysed. Lanthanide samples of varying composition are detected using ICP-MS, demonstrating this versatile and cost-effective approach that does not degrade the separation quality achieved on the MFD. This simple and inexpensive connection enables fast, low-cost sample preparation immediately prior to injection into an ICP-MS or other analytical instruments.

Lackey, Hope E.↗

Analysis of structure-property gradients in orthogonally machined chips and workpiece subsurface

Production of machined surfaces with optimized mechanical properties requires fundamental process-structure-property knowledge. In this paper, we focus on structure-property gradients in orthogonally cut OFHC Copper chips and the workpiece subsurface. We utilize orientation imaging microscopy and statistical spatial correlation metrics to quantify the microstructure. Constitutive elastic-plastic properties of the workpiece subsurface and chips are measured using spherical nanoindentation. Analysis of the data reveals significant structure and property gradients in both regions. Differences and similarities in structure and property gradients near the workpiece surface and tool-chip interface, and in the chip middle are discussed and explained.

42 ENGINEERING↗

Lab-on-a-chip platforms for quantification of multicellular interactions in bone remodeling

Highlights: • Microchips are developed for stimulating bone cells and quantifying activity. • A chip permits osteocyte loading and soluble signal analysis. • A chip enables quantification of bone resorption and formation. • This model may remove spatial and temporal limitations of existing systems. • This microfluidic approach shows promise for future discovery in the bone field. Researchers have been using lab-on-a-chip systems to isolate factors for study, simulate laboratory analysis and model cellular, tissue and organ level processes. The technology is increasing rapidly, but the bone field has been slow to keep pace. Novel models are needed that have the power and flexibility to investigate the elegant and synchronous multicellular interactions that occur in normal bone turnover and in disease states in which remodeling is implicated. By removing temporal and spatial limitations and enabling quantification of functional outcomes, the platforms should provide unique environments that are more biomimetic than single cell type systems while minimizing complex systemic effects of in vivo models. This manuscript details the development and characterization of lab-on-a-chip platforms for stimulating osteocytes and quantifying bone remodeling. Our platforms provide the foundation for a model that can be used to investigate remodeling interactions as a whole or as a standard mechanotransduction tool by which isolated activity can be quantified as a function of load.

60 APPLIED LIFE SCIENCES↗

Optically Transparent Thin-Film Electrode Chip for Spectroelectrochemical Sensing

The electrochemical and spectroelectrochemical applications of an optically transparent thin film electrode chip are investigated. The working electrode is composed of indium tin oxide (ITO); the counter and quasi-reference electrodes are composed of platinum. The stability of the platinum quasi-reference electrode is modified by coating it with a planar, solid state Ag/AgCl layer. The Ag/AgCl reference is characterized with scanning electron microscopy and energy-dispersive X-ray spectroscopy. Open circuit potential measurements indicate that the potential of the planar Ag/AgCl electrode varies a maximum of 20 mV over four days. Cyclic voltammetry measurements show that the electrode chip is comparable to a standard electrochemical cell. Randles-Sevcik analysis of 10 mM K3[Fe(CN)6] in 0.1 M KCl using the electrode chip shows a diffusion coefficient of 1.59 × 10-6 cm2/s, in comparison to the standard electrochemical cell value of 2.38 × 10-6 cm2/s. By using the electrode chip in an optically transparent thin layer electrode (OTTLE), the spectroelectrochemical modulation of [Ru(bpy)3]2+ florescence was demonstrated, achieving a detection limit of 36 nM.

Ag/AgCl↗

Online monitoring of solutions within microfluidic chips: simultaneous Raman and UV-Vis absorption spectroscopies

Microfluidics is an appealing analytical tool in the global effort to close the nuclear fuel cycle. Using a microfluidic chip permits analysis of greatly reduced sample volumes compared to what is necessary for traditional analytical methods. There is a commensurate reduction in disposal volume and cost. Development of spectroscopic methods practicable on the microscale are necessary to take advantage of the microchip configuration. This study uses simultaneously applied UV-vis and micro-Raman spectroscopies adapted to function on the microscale to analyze in situ both the Nd3+ (UV-vis active) and HNO3 (Raman active) concentrations in the same sample. An adjustable translation platform was designed to hold the micro-Raman probe above and perpendicular to the chip face, and the UV-vis probe in the plane of the chip. These complimentary spectral techniques when processed through multivariate PLS (Partial Least Squares) models gave an accurate picture of the widely varying solution concentrations as a function of time for each solution component. Solution matrix effects can drastically alter analyte signatures as measured by both UV-vis absorbance and Raman spectroscopy. PLS methods successfully modeled these spectral changes and accurately measured concentrations of components of interest within the microfluidic chip.

on-line monitoring, microfluidics, Raman, UV-vis↗

Low cost and massively parallel force spectroscopy with fluid loading on a chip

Current approaches for single molecule force spectroscopy are typically constrained by low throughput and high instrumentation cost. Herein, a low-cost, high throughput technique is demonstrated using microfluidics for multiplexed mechanical manipulation of up to ~4000 individual molecules via molecular fluid loading on-a-chip (FLO-Chip). The FLO-Chip consists of serially connected microchannels with varying width, allowing for simultaneous testing at multiple loading rates. Molecular force measurements are demonstrated by dissociating Biotin-Streptavidin and Digoxigenin-AntiDigoxigenin interactions along with unzipping of double stranded DNA of varying sequence under different dynamic loading rates and solution conditions. Rupture force results under varying loading rates and solution conditions are in good agreement with prior studies, verifying a versatile approach for single molecule biophysics and molecular mechanobiology. FLO-Chip enables straightforward, rapid, low-cost, and portable mechanical testing of single molecules that can be implemented on a wide range of microscopes to broaden access and may enable new applications of molecular force spectroscopy.

42 ENGINEERING↗

An on-chip phased array for non-classical light

Abstract Quantum science and technology can offer fundamental enhancements in sensing, communications and computing. The expansion from wired to wireless links is an exciting prospect for quantum technologies. For classical technologies, the advent of phased arrays enabled directional and adaptive wireless links by manipulating electromagnetic waves over free space. Here we demonstrate a phased array system on a chip that can receive, image and manipulate non-classical light over free space. We use an integrated photonic-electronic system with more than 1000 functional components on-chip to detect squeezed light. By integrating an array of 32 sub-wavelength engineered metamaterial antennas, we demonstrate a direct free-space-to-chip interface for reconfigurable quantum links. On the same chip, we implement a large-scale array of quantum-limited coherent receivers that can resolve non-classical signals simultaneously across 32 channels. With coherent readout and manipulation of these signals, we demonstrate 32-pixel imaging and spatially configurable reception of squeezed light over free space. Our work advances wireless quantum technologies that could enable practical applications in quantum communications and sensing.

Science & Technology - Other Topics↗

Optical pumping of deep traps in AlGaN/GaN-on-Si HEMTs using an on-chip Schottky-on-heterojunction light-emitting diode

In this work, by using an on-chip integrated Schottky-on-heterojunction light-emitting diode (SoH-LED) which is seamlessly integrated with the AlGaN/GaN high electron mobility transistor (HEMT), we studied the effect of on-chip light illumination on the de-trapping processes of electrons from both surface and bulk traps. Surface trapping was generated by applying OFF-state drain bias stress, while bulk trapping was generated by applying positive substrate bias stress. The de-trapping processes of surface and/or bulk traps were monitored by measuring the recovery of dynamic on-resistance R{sub on} and/or threshold voltage V{sub th} of the HEMT. The results show that the recovery processes of both dynamic R{sub on} and threshold voltage V{sub th} of the HEMT can be accelerated by the on-chip SoH-LED light illumination, demonstrating the potentiality of on-chip hybrid opto-HEMTs to minimize the influences of traps during dynamic operation of AlGaN/GaN power HEMTs.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A broadband single-chip transceiver for multi-nuclear NMR probes

In this article, we present an integrated broadband complementary metal-oxide semiconductor single-chip transceiver suitable for the realization of multi-nuclear pulsed nuclear magnetic resonance (NMR) probes. The realized single-chip transceiver can be interfaced with on-chip integrated microcoils or external LC resonators operating in the range from 1 MHz to 1 GHz. The dimension of the chip is about 1 mm{sup 2}. It consists of a radio-frequency (RF) power amplifier, a low-noise RF preamplifier, a frequency mixer, an audio-frequency amplifier, and fully integrated transmit-receive switches. As specific example, we show its use for multi-nuclear NMR spectroscopy. With an integrated coil of about 150 μm external diameter, a {sup 1}H spin sensitivity of about 1.5 × 10{sup 13} spins/Hz{sup 1/2} is achieved at 7 T.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

System-on-chip upgrade of millimeter-wave imaging diagnostics for fusion plasma

Monolithic, millimeter wave “system-on-chip” technology has been employed in chip heterodyne radiometers in a newly developed Electron Cyclotron Emission Imaging (ECEI) system on the DIII-D tokamak for 2D electron temperature and fluctuation diagnostics. The system employs 20 horn-waveguide receiver modules each with customized W-band (75–110 GHz) monolithic microwave integrated circuit chips comprising a W-band low noise amplifier, a balanced mixer, a ×2 local oscillator (LO) frequency doubler, and two intermediate frequency amplifier stages in each module. Compared to previous quasi-optical ECEI arrays with Schottky mixer diodes mounted on planar antennas, the upgraded W-band array exhibits >30 dB additional gain and 20× improvement in noise temperature; an internal eight times multiplier chain is used to provide LO coupling, thereby eliminating the need for quasi-optical coupling. The horn-waveguide shielding housing avoids out-of-band noise interference on each module. The upgraded ECEI system plays an important role for absolute electron temperature and fluctuation measurements for edge and core region transport physics studies. An F-band receiver chip (up to 140 GHz) is under development for additional fusion facilities with a higher toroidal magnetic field. Visualization diagnostics provide multi-scale and multi-dimensional data in plasma profile evolution. Finally, a significant aspect of imaging measurement is focusing on artificial intelligence for science applications.

47 OTHER INSTRUMENTATION↗