Search NASA⌕ Search

SEARCH · Search NASA

Results for “CHLORIDE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

An Experimental Study of the Solubility of Rare Earth Chloride Salts (La, Nd, Er) in HCl Bearing Water Vapor from 350 – 425 °C

In this work, the solubilities of the rare earth chlorides REECl 3 , where REE = (La, Nd, Er), were measured in HCl bearing water vapor from 350 – 425°C with water partial pressures ranging from 8 – 170 bar. Solubility data were fit to the Pitzer-Pabalan quasi-chemical model in order to extract thermodynamic parameters for the formation of the gaseous REE-chloride-water clusters REECl 3 (H 2 O) n . The data show that the solubility of the REE chlorides are orders of magnitude higher than salts such as NaCl or CuCl at low water fugacities, despite their sublimation energies being substantially higher. This enhanced solubility is likely due to the high enthalpy associated with binding a single water molecule to form the species REECl 3 (H 2 O), with derived enthalpies ranging from –378 to –465 kJ/mol. Addition of further water molecules to form higher order clusters (n > 1) involves enthalpy changes of ~ -20 kJ/mol, and are in effect thermodynamically suppressed over the temperature range 350 – 425°C. Despite the enhanced solubility of small REECl 3 water clusters, simulations of boiling processes demonstrate that the REE show highly conservative behavior, partitioning strongly into the dense aqueous phase. Not surprisingly, the presence of phosphates in the system makes this effect even more pronounced, completely immobilizing the REE. This would reduce transport in both the vapor and aqueous phase to negligible levels. However, we suggest that vapor phase transport of the REE may play a significant role in systems having a relatively low partial pressure of water (below the saturation point), where the relatively high stability of the first hydrated REE chloride clusters (REECl 3 (H 2 O) and REECl 3 (H 2 O) 2 ) will give a preference for gas transport of the REE relative to other elements. This can likely happen in systems involving a gas/melt exchange in fumarolic exhalations, where water vapor discharges at relatively low (close to atmospheric) pressures.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Investigating the Variation in Solvation Interactions of Choline Chloride-Based Deep Eutectic Solvents Formed Using Different Hydrogen Bond Donors

Choline chloride-based deep eutectic solvents (DESs) have gained widespread recognition as green solvents in catalysis and separation science as their designer properties permit solvation properties to be modulated by the choice of the hydrogen bond donor (HBD) as well as its molar ratio. Despite being one of the most popular classes of DESs, very little is currently understood regarding how their solvation characteristics differ among themselves as well as from other classes of DESs. Previous studies have shown that the catalytic activity, extraction efficiency, and solubilities of natural compounds can be influenced by the type of choline salt and HBD, but no study has systematically related these parameters with its solvation properties. In this study, inverse gas chromatography was employed for the first time to study the individual solvation characteristics of a diverse range of choline chloride and acetate-based DESs composed of amides, diols, organic acids, and carbohydrates. Furthermore, hydrogen bond acidity was found to be a dominant interaction for all DESs, especially those composed of organic acid HBDs. DESs composed of isomers of butane diol and hexane diol as HBDs exhibited higher hydrogen bond basicity and dispersive-type interactions compared to those composed of urea, acetamide, and organic acids with the position of the hydroxyl functional group influencing their solvation interactions. Choline acetate-based DESs exhibited lower dipolarity and stronger hydrogen bond basicity and dispersive-type interactions compared to choline chloride DESs. The solvation models developed in this study were used to interpret and explain DES behavior in previously reported studies involving catalysis, organic synthesis, and extractions demonstrating that the measured solute–solvent interactions can serve to predict the performance of choline chloride-based DESs when used in various applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Materials design of sodium chloride solid electrolytes Na3MCl6 for all-solid-state sodium-ion batteries

All-solid-state sodium-ion batteries have attracted increasing attention owing to the low cost of sodium and the enhanced safety compared to conventional Li-ion batteries. Recently, halides have been considered as promising solid electrolytes (SEs) due to their favorable combination of high ionic conductivity and chemical stability against high-voltage cathode materials. Although a wide variety of lithium chloride SEs, Li 3 MCl 6 , have been developed for high-voltage all-solid-state batteries, only a limited number of sodium chloride SEs have been reported. This study aims to offer a material design insight for the development of sodium chloride SEs through systematic assessment of the phase stability, electrochemical stability, and transport properties of novel Na 3 MCl 6 SEs. Structural calculations indicate that Na 3 MCl 6 exhibits trigonal $P\bar{3}$1c, monoclinic P2 1 /n, and trigonal $R\bar{3}$ phases, and the stable phase of Na 3 MCl 6 is dependent on the type and ionic radius of M. Na 3 MCl 6 typically exhibits a high oxidation potential, demonstrating good electrochemical stability against cathodes. The bond-valence site energy and ab initio molecular dynamics calculations revealed that Na 3 MCl 6 with P2 1 /n and $R\bar{3}$ phases showed low ionic conductivity, while the $P\bar{3}$1c phase slightly improved the ionic conductivity of Na 3 MCl 6 . The formation of Na vacancies by aliovalent substitution considerably increased the ionic conductivity up to four orders of magnitude for pristine Na 3 MCl 6 , exhibiting ~10 –5 S cm –1 for trigonal $P\bar{3}$1c and $R\bar{3}$ phases. The formation of defects could further enhance the ionic conductivity of Na 3 MCl 6 , and the optimization of defect type and ratio can be helpful in developing superionic Na chloride SEs. The material design of Na 3 MCl 6 in this study will provide fundamental guidelines for the development of novel sodium halide SEs for all-solid-state sodium-ion batteries.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Insights into the mechanism of electrochemical chloride oxidation in ethanol from X-ray photoelectron spectroscopy, quiescent solution voltammetry, and rotating ring-disk electrodes

The wide availability of bio-derived alcohols provides the impetus to develop processes that convert them to valuable chemicals. The chloride ion is a redox mediator for electrocatalytic ethanol oxidation to 1,1-diethoxyethane (1,1-DEE) through an ethyl hypochlorite (EtOCl) intermediate, and this paper describes the chloride oxidation reaction (COR) to EtOCl on a glassy carbon (GC) electrode. Voltammetry measurements on a GC electrode in inert acetonitrile solvent combined with ex situ X-ray photoelectron spectroscopy (XPS) establish a Volmer step, where chloride ion from solution chemisorbs and is oxidized. In reactive ethanol solvent, ethanol adsorbs, and analyzing the current response in an LSV experiment supports a two-electron-transfer to form EtOCl, with chemisorption of the regenerated chloride. Koutecký–Levich (K–L) analysis on a rotating ring disk electrode (RRDE) shows that the kinetic rate constant of the COR in ethanol is on the order of 10 −8 cm s −1 , which is five orders of magnitude faster than the direct alcohol oxidation reaction in a kinetically limited regime. This hydrodynamic approach in understanding the electrochemistry of this non-aqueous system extends the possibilities for mediated electrocatalysis in neat alcohol solvents.

Van Daele, Ryan D. [University of Michigan, Ann Ar↗

Importance of nuclear quantum effects on the hydration of chloride ion

Path-integral ab initio molecular dynamics (PI-AIMD) calculations have been employed to probe the nature of chloride ion solvation in aqueous solution. Nuclear quantum effects (NQEs) are shown to weaken hydrogen bonding between the chloride anion and the solvation shell of water molecules. As a consequence, the disruptive effect of the anion on the solvent water structure is significantly reduced compared to what is found in the absence of NQEs. Additionally, the chloride hydration structure obtained from PI-AIMD agrees well with information extracted from neutron scattering data. In particular, the observed satellite peak in the hydrogen-chloride-hydrogen triple angular distribution serves as a clear signature of NQEs. The present results suggest that NQEs are likely to play a crucial role in determining the structure of saline solutions.

36 MATERIALS SCIENCE↗

Lowering the Impedance of Lanthanum Strontium Manganite-Based Electrodes with Lanthanum Oxychloride and Lanthanum Scavenging Chloride Salts

The impact of infiltrating chloride salts on the electrochemical behavior of lanthanum strontium manganite-yttria stabilized zirconia (LSM-YSZ) cathodes was investigated under solid oxide fuel cell operation. Infiltrating a lanthanum chloride solution resulted in the formation of a lanthanum oxychloride (LaOCl) phase. A LaOCl phase also formed by infiltrating an ammonium chloride solution; however, lanthanum was scavenged from the LSM phase to form LaOCl. The third infiltrating solution, a combination of zirconium chloride and yttrium nitrate, formed LaOCl by scavenging lanthanum from LSM and produced YSZ nanoparticles. Electrochemical impedance spectroscopy results suggest that LaOCl improves oxygen adsorption kinetics compared to a baseline LSM-YSZ cathode, reducing the low frequency impedance by 30%. In addition, scavenging lanthanum from LSM improved oxygen ion diffusion polarization as indicated by the observed 40% reduction in high frequency impedance and improved serial ohmic resistance by 19%. Finally, YSZ nanoparticles further reduced the high frequency impedance and ohmic resistance by 45% and 23%, respectively. The findings reveal new strategies for lowering the impedance of LSM-YSZ cathodes.

Taylor, Thomas H.↗

In Situ High-Temperature TEM Observation of Inconel Corrosion by Molten Chloride Salts with N 2 , O 2 , or H 2 O

Here, in situ transmission electron microscopy (TEM) diffraction and imaging techniques are used to monitor and quantify corrosion of Inconel-625 by pure molten chloride salts (MgCl 2 – NaCl – KCl) at 500 °C–800 °C in 1.0 atm inert N 2 or pure O2, or by salts which are controllably hydrated in a high vacuum chamber. The isothermal corrosion rate R in inert N 2 increases from 203 ± 30 μ m year –1 at 700 °C to 463 ± 30 μ m year –1 at 800 °C. An oxygen ambient causes a six-fold increase to R = 1261 ± 170 μ m year –1 at 700 °C. Salt hydration dramatically accelerates corrosion to R > 3 × 10 5 μ m year –1 at 700 °C while it leads to a more moderate R = 95 ± 20 and 486 ± 30 μ m year –1 at 500 °C and 600 °C, respectively. These isothermal corrosion rates indicate that the molten chloride corrosion is significantly accelerated by salt hydration at temperatures above 600 °C, where corrosion is aggravated by increased generation and solubility of corrosive HCl gases. Hence, to reduce rate of corrosion it is important to both avoid incorporation of H 2 O into the system at each stage and ensure proper flushing of the system before increasing the temperature beyond 600 °C. Compositional analysis of the corroded cells indicate that corrosion in O 2 ambient is dominated by oxidation of metals by O 2 gas dissolved in the chloride melt, but corrosion in H 2 O ambients is caused by chlorination of metals by dissolved HCl gas and MgOH + ions. So, to reduce rate of corrosion, steps should be taken to tailor chloride melt compositions that has low solubility for HCl and O 2 . All of our corroded samples exhibit passive-protective oxide layers of Cr, Mg, and Ni. In addition, distinct volatile compounds of Ni, Mo and Cr involving NiCl 2 , (Na,K) 2 MoO 4 and CrO 2 (OH) 2 are detected in N 2 , H 2 O, and O 2 ambients, respectively. We believe that corrosion acceleration can be minimized by minimizing formation of volatile by-products or promoting reactions that could convert these volatile compounds to solid phases, as these volatile compounds led to destruction of protective oxide layers.

14 SOLAR ENERGY↗

Molten Chloride Thermophysical Properties, Chemical Optimization, and Purification

Next-generation concentrating solar power (CSP) technology requires high-temperature heat-transfer fluids and thermal energy storage that can operate in the temperature range of 500°–720°C. This high temperature demands a new chemistry for the heat-transfer fluids that must have high-temperature thermal and chemical stabilities, high energy density, and low corrosion rate on metallic materials used in the heat exchangers, piping, and thermal energy storage tanks. A ternary MgCl 2 -KCl-NaCl chloride-salt system has been proposed to achieve such goals, given its high-temperature thermal stability. The chloride-salt-based systems have been used by the metallurgy industry as the electrolyte to electrolytically extract metallic magnesium. They have also attracted attentions from the nuclear industry for developing the molten salt fast reactors that can operate at close to atmospheric pressure and at higher temperature than traditional light-water reactors. However, the corrosion properties of the ternary salt are not well known. The corrosion mechanism is believed to be correlated to the presence of MgOHCl impurity at the operation temperature. MgOHCl is fundamentally caused by the hygroscopic nature of the MgCl 2 component. Therefore, the first key objective of this project is to understand the nature of the corrosiveness of the ternary chloride-salt system and its prevention by designing new lab-scale purification processes. Because of its importance, a working group called the Chloride Salt Collective across multiple U.S. Department of Energy national laboratories is established to gain experimental agreement on the corrosion behaviors. In addition, water generation during salt dehydration could lead to highly corrosive HCl/water mixture via a hydrolysis process between water and anhydrous MgCl 2 or MgCl 2 hydrates. MgOHCl will eventually be converted to MgO particulates regardless of the chemical path chosen (i.e., by thermal decomposition, chemical purification with an active metal, or electrochemical purification utilizing the reduction power of electron flows). Large MgO particles with high hardness can wear out bearing and bushing and even clog the delicate channels in the primary heat exchanger. Because of this, a second objective is to understand the chemistry behind salt purification and transfer the scientific understanding to a set of engineering know-how for large-scale salt melter design. Because there is limited information on the thermophysical properties and the sensitivity of these properties around the targeted salt composition, a third objective is to measure thermophysical properties relevant to system and component design and support Topic 1 Liquid Pathway development. For example, composition shift due to salt reaction with water can be a potential issue because it can lead to changes of thermophysical properties, such as (1) melting point (or freeze point), which can jeopardize safe operation of the supercritical CO 2 power cycle proposed for next-generation CSP, and (2) heat capacity and density, which can decrease the overall power-generation capability of the plants. The value of the thermal conductivity of the selected salt composition is also a critical criterion for the solar receiver design.

14 SOLAR ENERGY↗

Continuous Particle Monitoring and Removal for Molten Chloride CSP Systems

This report describes the technologies that were developed as part of the Continuous Particle Monitoring and Removal for Molten Chloride CSP Systems project that was funded by the EERE Solar Energy Technologies Office during FY2021. This project consisted of two main tasks: (1) the development electrical resistance tomography (ERT) sensors to provide particle sensing capabilities for CSP-relevant molten chloride salts, and (2) the development of vortex separation technologies to enable efficient removal of particles from the salt. Both of these tasks are crucial because, although the Gen3 CSP chloride heat transfer fluid is inexpensive and can achieve high temperatures, major issues with erosion corrosion and clogging can arise from the presence of MgO particles within the salt. The particle monitoring and removal technologies were both demonstrated over the course of this project. The ERT sensors were able to achieve their performance targets by providing accurate particle concentration measurements over a range from 0.0 to 8.0 wt%. The vortex separators were able to demonstrate separation of particles from molten salt streams, but the separation efficiencies were lower than the targeted level of 90%. With further development and deployment, these technologies will ultimately help to enable successful long-term operations of CSP systems that make use of high-temperature chloride salts.

14 SOLAR ENERGY↗

TEX-Chlorine Assemblies: Highly Enriched Uranium Plates with Sodium Chloride Absorbers Using Polyethylene Moderator and Polyethylene Reflector

This evaluation documents highly enriched uranium (HEU) experimental critical configurations with polyethylene moderators and sodium chloride absorbers conducted as part of the United States Nuclear Criticality Safety Program’s Thermal/Epithermal eXperiments (TEX) program. HEU-MET-MIXED-021 provides the benchmark evaluation of five TEX experiments designed to establish baseline configurations with HEU Jemima plates moderated by high density polyethylene (HDPE). The TEX-HEU experiments were designed to cover five different fission energy regimes by varying the thickness of the interstitial HDPE moderator, with varying fractions of thermal, intermediate, and fast fissions, and to be easily modified to accommodate test materials of interest. HEU-MET-INTER-013 documents the first TEX-HEU variation, incorporating hafnium in seven different experimental configurations. This evaluation covers an additional variant that incorporates absorber plates of compacted high-purity sodium chloride salt. These experiments were motivated by a criticality safety need for validation data for uranium purification by means of electrorefining with chloride salts, especially thermal and intermediate energy configurations resulting from moderator upset conditions, and their design was optimized by matching sensitivity profiles from application cases. All three experimental configurations are judged to be acceptable as benchmark cases. The main parameter varied between the configurations is the thickness of the polyethylene moderators and the sodium chloride absorbers between the HEU plates. Varying the thickness of the polyethylene tunes the neutron energy spectrum between majority thermal (Case 1 and 2) and intermediate (Case 3). The fission fractions, presented in Table 1, are determined calculationally. Case 3 is cross listed as HEU-MET-INTER-014.

42 ENGINEERING↗

Development of a Chlorine Cathode and Anode Basket Assembly for Production of Uranium Chloride

A chlorine cathode has been developed for in situ chlorination of metals, oxides, and oxychlorides in molten chloride electrolytes that could be used to support synthesis of chloride fuel salts for molten salt reactors. The chlorine cathode is designed to electrochemically reduce chlorine gas to generate chloride ions that, when paired with a metal anode, chlorinate that metal as it is oxidized into the salt. The designed porous carbon electrode effectively distributes Cl 2 to the electrode surface and efficiently generates Clions in the molten chloride electrolyte. This report highlights recent improvements made to the electrode assembly, with a focus on operational control of the anode basket stability. Synthesis tests demonstrated the successful chlorination of uranium metal, resulting in 3.6 wt% uranium generated in the LiCl-KCl base salt in 45 minutes, performed in a bench-scale chlorination apparatus. Higher concentrations could be achieved by applying longer chlorination times or increasing the amount of uranium loaded in the anode basket. Overall, the chlorine cathode can be used with an appropriately designed anode to chlorinate uranium in situ for synthesis of molten salt reactor fuel salts.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Aqueous chloride stress corrosion cracking of titanium: A comparison with environmental hydrogen embrittlement

The physical characteristics of stress corrosion cracking of titanium in an aqueous chloride environment are compared with those of embrittlement of titanium by a gaseous hydrogen environment in an effort to help contribute to the understanding of the possible role of hydrogen in the complex stress corrosion cracking process. Based on previous studies, the two forms of embrittlement are shown to be similar at low hydrogen pressures (100 N/sqm) but dissimilar at higher hydrogen pressures. In an effort to quantify this comparison, tests were conducted in an aqueous chloride solution using the same material and test techniques as had previously been employed in a gaseous hydrogen environment. The results of these tests strongly support models based on hydrogen as the embrittling species in an aqueous chloride environment. Further, it is shown that if hydrogen is the causal species, the effective hydrogen fugacity at the surface of titanium exposed to an aqueous chloride environment is equivalent to a molecular hydrogen pressure of approximately 10 N/sqm.

Nelson, H. G.↗

Passive, Direct-Read Monitoring System for Selective Detection and Quantification of Hydrogen Chloride

Monitoring the exposure of an employee to hydrogen chloride or hydrochloric acid in the presence of other acids has been a challenge to the industrial hygiene community. The capability of a device to differentiate the levels of acid vapors would allow for more accurate determinations of exposure and therefore improved occupational health. In this work, a selective direct-read colorimetric badge system was validated for Short Term Exposure Limit (STEL) monitoring of hydrogen chloride. The passive colorimetric badge system consists of a direct reading badge and a color scale. The badge has a coated indicator layer with a diffusive resistance in the shape of an exclamation mark. An exclamation mark will appear if hydrogen chloride is present in the atmosphere at concentrations at or above 2.0 ppm. By using the color scale, the intensity of the color formed on the badge can be further quantified up to 25 ppm. The system was validated according to a protocol based on the NIOSH Protocol for the Evaluation of Passive Monitors. The badge was exposed to relative humidities ranging from 11% to 92%, temperatures ranging from 7 C to 400 C and air velocities ranging from 5 cm/sec to 170 cm/sec. All experiments were conducted in a laboratory vapor generation system. Hydrofluoric acid, nitric acid, sulfuric acid, chlorine, hydrogen sulfide and organic acids showed no effect on the performance of the hydrogen chloride monitoring system. The passive badge and color scale system exceeded the accuracy requirements as defined by NIOSH. At ambient conditions, the mean coefficient of variation was 10.86 and the mean bias was 1.3%. This data was presented previously at the American Industrial Hygiene Conference and Exposition in Toronto, Canada in June 1999.

Chapman, K. B.↗

Effect of Solution pH and Chloride Concentration on Akaganeite Precipitation: Implications for Akaganeite Formation on Mars

Akaganeite (Beta-FeOOH, chloride-containing Fe(III) (hydr)oxide) has been recently discovered on the surface of Mars by the Mars Science Laboratory Curiosity rover in Yellowknife Bay, Gale Crater, Mars [1] and from orbit by the Mars Reconnaissance Orbiter in Robert Sharp crater and Antoniadi basin [2]. However, the mechanism and aqueous environmental conditions of akaganeite formation (e.g., pH and chloride concentration) remain unknown. We have investigated formation of akaganeite through Fe(III) hydrolysis at variable initial pH and chloride concentrations. The formed Fe(III) precipitates were characterized by instruments similar to instruments on Mars robotic spacecraft. Syntheses were performed through hydrolysis of Fe(III) perchlorate with addition of Na cloride (Fe/Cl ratio between 0.5 and 5) and at initial pH of 1.5, 2, 4, 6 and 8 at 90degC. X-ray diffraction analysis revealed formation of akaganeite alone or in mixture with goethite, hematite and ferrihydrite at all initial pHs and Fe/Cl ratio between 0.5 and 2 while akaganeite precipitated only at pH 1.5 and Fe/Cl greater than2. Chloride content of akaganeite was affected by initial pH and decreased from 20-60 mg/g at pH 1.5 to less than 0.1 mg/g at pH 8. The synthesized akaganeite samples were also characterized by Mössbauer and infrared spectroscopy and volatiles were analysed by thermal and evolved gas analysis. The obtained characterization data will be compared to published data from rover and orbital missions [1-3] to determine martian akaganeite composition, crystallinity and formation conditions.

Peretyazhko, T. A.↗

Methods and systems for producing a metal chloride or the like

Systems and methods for producing metal chloride M ICl x from metal M I without the use of HCl and/or Cl 2 gases, including: a bath vessel holding conductive fluid; an anode disposed in the conductive fluid, the anode including metal M.sup.I; a cathode assembly disposed in the conductive fluid, the cathode assembly including a cathode vessel including porous and non-porous portions, the non-porous portion holding sacrificial metal chloride M IICl y substantially separate from metal chloride M ICl x , wherein the cathode assembly includes a center lead disposed within the cathode vessel operable for delivering charge to sacrificial metal chloride M IICl y ; and a power supply coupling the anode and the cathode assembly, the power supply polarized to produce current flow in a direction that causes anodic dissolution of metal M.sup.I into the conductive fluid and deposition of metal M.sup.II within the cathode vessel. The systems and methods apply equally to producing metal halide M IX x .

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Effectiveness of Vapor Corrosion Inhibitors Under Elevated Chloride Conditions for Aboveground Storage Tank Application

The sand quality used to construct the tank pad is an important contributing factor to the rate of corrosion that occurs on the soil-side of the aboveground storage tanks (ASTs) floor plates. Clean sand that meets specific criteria provides the first line of defense for mitigation of tank floor corrosion. However, it has been observed that the sand quality used for some existing tanks differ greatly from the specifications provided in the API 651 standard; this could be partially due to initial sand quality not meeting the specification, and partially due to the environmental effects over time. For example, rain-water intrusion could lead to higher than the specified contents of corrosive species such as chloride. Tank operators are increasingly using vapor corrosion inhibitors (VCIs) either as a stand alone or in combination with cathodic protection (CP) for ASTs to mitigate soil-side corrosion. VCIs are delivered either through-thefloor or injected through the ports in the ring wall. Experimental studies were conducted to evaluate VCIs’ performance at elevated chloride concentrations and to study the effectiveness of the delivery methods under extreme chloride conditions. The experimental work found that VCI performance is robust and not compromised due to high chloride levels, such as 300 ppm or more. The work also showed that the through-the-floor VCI delivery method is more beneficial compared to the through-the-sand-pad method when tank pad corrosivity is elevated.

Shukla, Pavan K.↗

Pozzolanic reactivity of natural pozzolans, ground glasses and coal bottom ashes and implication of their incorporation on the chloride permeability of concrete

It is well understood that the partial replacement of portland cement with pozzolans in sufficient proportions results in improved long-term performance of concrete. However, dwindling availability of the most widely used pozzolan in the construction industry, fly ash, is forecast due to the termination of coal-fired electricity power stations around the world, necessitating the exploration of alternative pozzolans. Experimental investigations are conducted to study the performance of traditional pozzolans such as fly ash, silica fume and natural pozzolans (metakaolin, pumice, perlite and lassenite) together with novel pozzolans, including ground glasses (high-alkali and low-alkali), and ground bottom ash. Twenty-one concrete mixtures are examined for compressive strength, electrical conductivity, electrical resistivity, chloride permeability, and chloride migration coefficient. The reactivity of pozzolans studied is also determined in terms of compressive strength in lime-pozzolan mortar using a modified lime-reactivity test method. Many of the materials tested demonstrate the potential to be used in place of fly ash. However, a wide variation in the performance of these materials is evident which highlights the need for a reliable test to determine the level of reactivity of a pozzolan. The results indicate that the 7-day strength in the modified lime-reactivity test provides a good indication of the pozzolanic reactivity of the material and of how the material can be expected to contribute to the strength and permeability of concrete. The use of electrical resistivity as an indicator of the performance of pozzolans in terms of strength development and chloride penetration resistance when used to partially replace portland cement in concrete is also discussed.

36 MATERIALS SCIENCE↗

Internal insulation and corrosion control of molten chloride thermal energy storage tanks

A chloride-based molten-salt system that uses a ternary blend of MgCl 2 /KCl/NaCl is investigated to provide higher-temperature thermal energy storage capability than conventional nitrate salt-based systems. Despite their high thermal stability and operating temperature, molten chlorides present several challenges, including the design of internal liners to prevent the corrosion and thermal stress of alloy tank shells. This work discusses issues and potential solutions related to containment of molten chloride salt, specifically the optimization of the hot face refractory materials for use as internal liners. Furthermore, three down-selected refractory materials were analyzed with respect to permeation of salt through the material as well as chemical stability during high temperature operation. Through the application of X-ray imaging and electron spectroscopy techniques, highly stable secondary surface phases in equilibrium with the molten salt were identified, as well as time-dependent changes in the salt composition itself.

25 ENERGY STORAGE↗