Search NASA⌕ Search

SEARCH · Search NASA

Results for “CIRCULATORY SYSTEM”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Radiation Hazard Detector

NASA technology has made commercially available a new, inexpensive, conveniently-carried device for protection, of people exposed to potentially dangerous levels of microwave radiation. Microwaves are radio emissions of extremely high frequency. They can be hazardous but the degree of hazard is not yet well understood. Generally, it is believed that low intensity radiation of short duration is not harmful but that exposure to high levels can induce deep internal burns, affecting the circulatory and nervous systems, and particularly the eyes. The Department of Labor's Occupational Safety and Health Administration (OSHA) has established an allowable safe threshold of exposure. However, people working near high intensity sources of microwave energy-for example, radar antennas and television transmitters-may be unknowingly exposed to radiation levels beyond the safe limit. This poses not only a personal safety problem but also a problem for employers in terms of productivity loss, workman's compensation claims and possible liability litigation. Earlier-developed monitoring devices which warn personnel of dangerous radiation levels have their shortcomings. They can be cumbersome and awkward to use while working. They also require continual visual monitoring to determine if a person is in a dangerous area of radiation, and they are relatively expensive, another deterrent to their widespread adoption. In response to the need for a cheaper and more effective warning system, Jet Propulsion Laboratory developed, under NASA auspices, a new, battery-powered Microwave Radiation Hazard Detector. To bring the product to the commercial market, California Institute Research Foundation, the patent holder, granted an exclusive license to Cicoil Corporation, Chatsworth, California, an electronic components manufacturer.

Source record↗

On a basic model of circulatory, fluid, and electrolyte regulation in the human system based upon the model of Guyton

A detailed description of Guyton's model and modifications are provided. Also included are descriptions of several typical experiments which the model can simulate to illustrate the model's general utility. A discussion of the problems associated with the interfacing of the model to other models such as respiratory and thermal regulation models which is prime importance since these stimuli are not present in the current model is also included. A user's guide for the operation of the model on the Xerox Sigma 3 computer is provided and two programs are described. A verification plan and procedure for performing experiments is also presented.

White, R. J.↗

A predictive model of human performance.

An attempt is made to develop a model describing the overall responses of humans to exercise and environmental stresses for prediction of exhaustion vs an individual's physical characteristics. The principal components of the model are a steady state description of circulation and a dynamic description of thermal regulation. The circulatory portion of the system accepts changes in work load and oxygen pressure, while the thermal portion is influenced by external factors of ambient temperature, humidity and air movement, affecting skin blood flow. The operation of the model is discussed and its structural details are given.

Walters, R. F.↗

Evaluation of dual-tip micromanometers during 21-day implantation in goats

Investigative research efforts using a cardiovascular model required the determination of central circulatory haemodynamic and arterial system parameters for the evaluation of cardiovascular performance. These calculations required continuous beat-to-beat measurement of pressure within the four chambers of the heart and great vessels. Sensitivity and offset drift, longevity, and sources of error for eight 3F dual-tipped micromanometers were determined during 21 days of implantation in goats. Subjects were instrumented with pairs of chronically implanted fluid-filled access catheters in the left and right ventricles, through which dual-tipped (test) micromanometers were chronically inserted and single-tip (standard) micromanometers were acutely inserted. Acutely inserted sensors were calibrated daily and measured pressures were compared in vivo to the chronically inserted sensors. Comparison of the pre- and post-gain calibration of the chronically inserted sensors showed a mean sensitivity drift of 1.0 +/- 0.4% (99% confidence, n = 9 sensors) and mean offset drift of 5.0 +/- 1.5 mmHg (99% confidence, n = 9 sensors). Potential sources of error for these drifts were identified, and included measurement system inaccuracies, temperature drift, hydrostatic column gradients, and dynamic pressure changes. Based upon these findings, we determined that these micromanometers may be chronically inserted in high-pressure chambers for up to 17 days with an acceptable error, but should be limited to acute (hours) insertions in low-pressure applications.

Non-NASA Center↗

NASA Human Research Program Space Radiation Program Element

The goal of the NASA Human Research Program's Space Radiation Program Element is to ensure that crews can safely live and work in the space radiation environment. Current work is focused on developing the knowledge base and tools required for accurate assessment of health risks resulting from space radiation exposure including cancer and circulatory and central nervous system diseases, as well as acute risks from solar particle events. Division of Space Life Sciences (DSLS) Space Radiation Team scientists work at multiple levels to advance this goal, with major projects in biological risk research; epidemiology; and physical, biophysical, and biological modeling.

Chappell, Lori↗

Hemodynamic Responses to Head and Neck Cooling

Personal thermoregulatory systems which provide head and neck cooling are used in the industrial and aerospace environments to alleviate thermal stress. However, little information is available regarding the physiologic and circulatory changes produced by routine operation of these systems. The objective of this study was to measure the scalp temperature and circulatory responses during use of one commercially available thermal control system. The Life Support Systems, Inc. Mark VII portable cooling system and a liquid cooling helmet were used in this study. Two EEG electrodes and one skin temperature transducer were placed on the anterior midline of the scalp to measure the scalp blood and temperature. Blood flow was measured using a bipolar impedance rheograph. Ten subjects, seated in an upright position at normal room temperature, were tested at high, medium, moderate, moderate-low and low coolant temperatures. Scalp blood flow was recorded continuously using a computer data acquisition system with a sampling frequency of 200 Hz. Scalp temperature and cooling helmet Inlet temperature was logged periodically during the test period. This study quantifies the effect of head cooling upon scalp temperature and blood flow. These data may also be used to select operational specifications of the head cooling system for biomedical applications such as the treatment of migraine headaches, scalp cooling during chemotherapy, and cooling of multiple sclerosis patients.

Ku, Yu-Tsuan E.↗

User's instructions for the whole-body algorithms

The design of an algorithm that provides for the simulation of long and short term biological stresses is reported. The physiological responses of models representing circulatory, respiratory, cardiovascular, and thermoregulatory systems during space flight simulation are described.

Grounds, D. J.↗

Analysis of head-down tilt as an analog of weightlessness using a methematical simulation model

Antiorthostasis or head down tilt of a moderate degree was used as a ground based analog of weightless space flight to study headward fluid shifts, decreased plasma volume, orthostatic intolerance and muscular skeletal degradation. A mathematical model was used to help interpret these observations. The model proved most valuable for these studies was originally developed as a description of the major circulatory, fluid and electrolyte control systems. Two different experimental studies are employed to validate the model. The first is a 24 hour head down tilt study and the second is a 7 day head down bed rest study. The major issues addressed include the reduction in plasma volume, the dynamic changes of venous pressure and cardiac output, the extent of central hypervolemia during long term zero g exposure, the existence of an early diuresis, the mechanisms which alter the renal regulating hormones during the short term and long term periods, the significance of potassium loss on other zero g responses, and the role of transcapillary filtration in adjusting fluid shifts. The use of mathematical models as an interpretive and analysis technique for experimental research for space life science is illustrated.

Leonard, J. I.↗

Operational Characteristics of Four Commercially Available Personal Cooling Vests

Personal thermoregulatory systems which provide chest cooling are used in the industrial and aerospace environments to alleviate thermal stress. However, little information is available regarding the physiologic and circulatory changes produced by routine operation of these systems. The objectives of this study were to compare the effectiveness of two passive and two active cooling vests, and to measure the body temperature and circulatory changes produced by each cooling vest configuration. The MicroClimate Systems and the Life Enhancement Tech(LET) lightweight liquid cooling vests, the Steele Vest and LET's Zipper Front Garment were used to cool the chest region of 11 male and 10 female subjects (25 to 55 yr.) in this study. Calf, forearm and finger blood flows were measured using a tetrapolar impedance rheograph. The subjects, seated in an upright position at normal room temperature (approx.21 C), were tested for 60 min. with the cooling system operated at its maximum cooling capacity. Blood flows were recorded continuously using a computer data acquisition system with a sampling frequency of 250 Hz. Oral, right and left ear temperatures and cooling system parameters were logged manually every 5 min. Arm, leg, chest and rectal temperatures; heart rate; respiration; and an activity index were recorded continuously on a URI Inc. Biolog ambulatory monitor. In general, the male and female subjects' rectal and ear temperature responses to cooling were similar for all vest configurations tested. Oral temperatures during the recovery period were significantly (P<0.05) lower than during the control period, approx.0.2 - 0.5 C, for both men and women wearing any of the four different garments. The corresponding car temperatures were significantly (P<0.05) decreased approx.0.2 - 0.3 C by the end of the recovery period. Compared to the control period, no significant differences were found in rectal temperatures during cooling and recovery periods. These results show that all vest configurations elicit a similar thermal response in both male and female subject groups. However, subject population variance was rather large and may have masked differences between the vests. One vest may prove more effective than another for a given individual, and experience is the only means of determining this.

Ku, Yu-Tsuan E.↗

Biomedical Application of Aerospace Personal Cooling Systems

Personal thermoregulatory systems which are used by astronauts to alleviate thermal stress during extravehicular activity have been applied to the therapeutic management of multiple sclerosis. However, little information is available regarding the physiologic and circulatory changes produced by routine operation of these systems. The objectives of this study were to compare the effectiveness of two passive and two active cooling vests and to measure the body temperature and circulatory changes produced by each cooling vest configuration. The MicroClimate Systems and the Life Enhancement Tech(LET) lightweight liquid cooling vests, the Steele Vest and LET's Zipper Front Garment were used to cool the chest region of 10 male and female subjects (25 to 55 yr.) in this study. Calf, forearm and finger blood flows were measured using a tetrapolar impedance rheograph. The subjects, seated in an upright position at normal room temperature (approx.22C), were tested for 60 min. with the cooling system operated at its maximum cooling capacity. Blood flows were recorded continuously using a computer data acquisition system with a sampling frequency of 250 Hz. Oral, right and left ear temperatures and cooling system parameters were logged manually every 5 min. Arm, leg, chest and rectal temperatures; heart rate; respiration; and an activity index were recorded continuously on a U.F.I., Inc. Biolog ambulatory monitor. In general, the male and female subjects' oral and ear temperature responses to cooling were similar for all vest configurations tested. Oral temperatures during the recovery period were significantly (P<0.05) lower than during the control period, approx. 0.2 - 0.5C, for both men and women wearing any of the four different garments. The corresponding ear temperatures were significantly (P<0.05) decreased approx.0.2 - 0.4C by the end of the recovery period. Compared to the control period, no significant differences were found in rectal temperatures during cooling and recovery periods.

Ku, Yu-Tsuan E.↗

Static, noise, and transition tests of a combined-surface-blowing V/STOL lift/propulsion system

Efficient thrust vectoring and high levels of circulatory lift were obtained in tests of a half model V/STOL airplane by using a type of externally blown jet flap in which the jet exhaust from wing-mounted cruise fans is directed over both upper and lower surfaces of a flapped wing. Approximately 90% thrust recovery with 87 deg of thrust vectoring was achieved under static conditions using 89 deg of trailing edge flap deflection. The approximately 10% loss appears to be associated primarily with pressure losses due to the flap brackets or slot entries. The jet induced lift was shown to be 55% of the theoretical value for a fullspan jet-flapped wing, even though only 27.5% of the wingspan was immersed in the jet. Steady rate of descent capability in excess of 1,000 feet per minute is predicted. The possibility of significant aerodynamic-noise cancelling when blowing over both surfaces at high velocities is indicated.

Schoen, A. H.↗

Operational Characteristics of Two Commercially Available Personal Cooling Vests

Personal thermoregulatory systems which provide chest cooling are used in the industrial and aerospace environments to alleviate thermal stress. However, little information is available regarding the physiologic and circulatory changes produced by routine operation of these systems. The objectives of this study were to compare the effectiveness of two passive cooling vests, and to measure the body temperature and circulatory changes produced by each cooling vest configuration. A Life Enhancement Technologies, (LET) ice vest garment and a Steele, Inc. vest were used to cool the chest region of 11 male subjects (25 to 55 yr) in this study. Calf, forearm and finger blood flows were measured using a tetrapolar impedance rheograph. The subjects, seated in an upright position at normal room temperature (approximately 21 C) were tested for 60 min. with the cooling system operating at its maximum cooling capacity. Blood flows were recorded continuously using a computer data acquisition system with a sampling frequency of 250 Hz. Oral, right and left ear temperatures and cooling system parameters were logged manually every 5 min. Arm, leg, chest and rectal temperatures; heart rate; respiration; and an activity index were recorded continuously on a U.F.I., Inc. Biolog ambulatory monitor. No significant differences were found in either the oral or ear temperature responses to the two vests. However, the rectal and mean skin temperatures at the end of the cooling period were both significantly lower (P less than 0.05), approximately 0.2 and 1.9 C, respectively for the LET vest than for the Steele garment. These data show that different vest configurations may produce different thermal responses in healthy male subjects which should be considered in the use of these cooling garments.

Ku, Yu-Tsuan E.↗

Spaceflight Biospecimen Sharing in Support of Science Discovery and Exploration

For decades, NASA and international partners have flown non-human biological experiments in space to understand the effects of spaceflight and address potential biological hazards. Sending organisms into space is a costly endeavor which makes space-flown biological specimens a valuable resource. To enable maximum scientific return, samples not required by the Principal Investigators are harvested and collected mostly by NASA’s Space Biology Biospecimen Sharing Program. These specimens are collected according to well-established SOPs that maintain quality and integrity. The specimens are then preserved, archived, and made available to the international scientific community through NASA’s Institutional Scientific Collection (ISC) at Ames Research Center (ARC). The ISC-ARC biospecimens and descriptive metadata are findable and accessible for request through the Life Sciences Data Archive (LSDA). The NASA ISC-ARC currently stores over 32,000 specimens from Shuttle, International Space Station, and ground-based investigations (spaceflight analog experiments involving either hindlimb unloading, centrifugation, or partial weight-bearing study designs). Tissues are predominantly from mice and rats, though samples are also available from bacteria and quail. The specimens include tissues from many physiological systems including musculoskeletal, neurosensory, reproductive, respiratory, circulatory, and digestive. Tissues are stored at -80°C, -20°C, +4°C, or ambient and preserved in various fixatives. Descriptive metadata is available for all samples. Historically, these tissues have been used for a wide range of analyses, including histology, genomics, and transcriptomics. Plans are underway to expand the ISC-ARC beyond the mostly-rodent contents, to include a space-relevant microbial culture collection including bacteria, fungi, and yeast. This expansion of the ISC-ARC will now involve identifying and standardizing best practices for microbial curations. To ensure safe long-term storage of microbial isolates, a microbiology laboratory will be dedicated for identification, cell culture, and lyophilization. Awarding of tissue to public science investigators has resulted in 33 publications since 2011, with 48 requests being submitted since 2016. Of note, NASA GeneLab has been awarded ISC-ARC biospecimens in the past few years. GeneLab processes the biospecimens to generate various levels of ‘omics’ data, which are published on GeneLab’s open access online platform for bioinformatics analysis and visualization. This has helped a systems biology community grow around the processed-biospecimens’ datasets, resulting in many new publications and insights. Websites: https://www.nasa.gov/ames/research/space-biosciences/isc-bsp ; https://lsda.jsc.nasa.gov/Biospecimen

Ryan T. Scott↗

Description, validation, and modification of the Guyton model for space-flight applications. Part A. Guyton model of circulatory, fluid and electrolyte control. Part B. Modification of the Guyton model for circulatory, fluid and electrolyte control

The mathematical model that has been a cornerstone for the systems analysis of space-flight physiological studies is the Guyton model describing circulatory, fluid and electrolyte regulation. The model and the modifications that are made to permit simulation and analysis of the stress of weightlessness are described.

Leonard, J. I.↗

NASA Institutional Scientific Collection and Biospecimen Sharing Program at Ames Research Center

For decades, NASA and their international partners have flown and conducted non-human biological experiments in space to understand the effects of spaceflight and address potential biological hazards. It is imperative to understand the basic science and health risks associated with spaceflight, along with developing countermeasures, as humanity ventures back to the Moon, and then to Mars and beyond. Sending organisms into space is a costly endeavor which makes space-flown biological specimens a valuable resource. To enable maximum scientific return, samples not required by the Principal Investigators are harvested, preserved and archived in NASA’s Institutional Scientific Collection (ISC) at Ames Research Center (ARC). These specimens are collected according to well-established SOPs that maintain their quality and integrity. To enable new discoveries, the samples are then made available to the international scientific community through NASA’s Biospecimen Sharing Program (BSP). The NASA ISC currently stores over 32,000 specimens from Shuttle, International Space Station and ground-based investigations. Tissues are predominantly from mice and rats, though samples are also available from bacteria and quail. The specimens include tissues from all biological systems including musculoskeletal, neurosensory, reproductive, respiratory, circulatory, and digestive and are stored at -80°C, -20°C, +4°C, or ambient. Descriptive metadata is available for all samples. Historically, these tissues have been used for a wide range of analyses, including histology, genomics, and transcriptomics. Also available through the ISC are tissue from NASA’s Space Radiation Laboratory. To study the effects of space radiation, researchers irradiate biological specimens and unused samples are made available through the LSDA. These biospecimens and data are made available through the public Life Sciences Data Archive (LSDA) website to promote basic discovery, pre-clinical and clinical science. Visit the NASA ISC-BSP website for more information. Websites: https://lsda.jsc.nasa.gov/ ; https://www.nasa.gov/ames/research/space-biosciences/isc-bsp

Space Flown Biospecimens↗

NASA Institutional Scientific Collection and Biospecimen Sharing Program at Ames Research Center

For decades, NASA and their international partners have flown and conducted non-human biological experiments in space to understand the effects of spaceflight and address potential biological hazards. It is imperative to understand the basic science and health risks associated with spaceflight, along with developing countermeasures, as humanity ventures back to the Moon, and then to Mars and beyond. Sending organisms into space is a costly endeavor which makes space-flown biological specimens a valuable resource. To enable maximum scientific return, samples not required by the Principal Investigators are harvested, preserved and archived in NASA’s Institutional Scientific Collection (ISC) at Ames Research Center (ARC). These specimens are collected according to well-established SOPs that maintain their quality and integrity. To enable new discoveries, the samples are then made available to the international scientific community through NASA’s Biospecimen Sharing Program (BSP). The NASA ISC currently stores over 32,000 specimens from Shuttle, International Space Station and ground-based investigations. Tissues are predominantly from mice and rats, though samples are also available from bacteria and quail. The specimens include tissues from all biological systems including musculoskeletal, neurosensory, reproductive, respiratory, circulatory, and digestive and are stored at -80°C, -20°C, +4°C, or ambient. Descriptive metadata is available for all samples. Historically, these tissues have been used for a wide range of analyses, including histology, genomics, and transcriptomics. Also available through the ISC are tissue from NASA’s Space Radiation Laboratory. To study the effects of space radiation, researchers irradiate biological specimens and unused samples are made available through the LSDA. These biospecimens and data are made available through the public Life Sciences Data Archive (LSDA) website to promote basic discovery, pre-clinical and clinical science. Visit the NASA ISC-BSP website for more information.

Space Flown Biospecimens↗

Physiologic Responses Produced by Active and Passive Personal Cooling Vests

Personal thermoregulatory systems which provide chest cooling are used in the industrial and aerospace environments to alleviate thermal stress. However, little information is available regarding the physiologic and circulatory changes produced by routine operation of these systems. The objectives of this study were to document and compare the subjects' response to three cooling vests in their recommended configurations. The Life Enhancement Tech (LET) lightweight active cooling vest with cap, the MicroClimate Systems Change of Phase garment (MCS), and the Steele Vest were each used to cool the chest regions of 12 male and 8 female Healthy subjects (21 to 69 yr.) in this study. The subjects, seated in an upright position at normal room temperature (approx. 22 C), were tested for 60 min. with one of the cooling garments. The LET active garment had an initial coolant fluid inlet temperature of 60 F, and was ramped down to 50 F. Oral, right and left ear canal temperatures were logged manually every 5 min. Arm, leg, chest and rectal temperatures; heart rate; and respiration were recorded continuously on a U.F.I., Inc. Biolog ambulatory monitor. For men, all three vests had similar, significant cooling effects. Decreases in the average rectal temperature, oral temperature, and ear canal temperatures were approximately 0.2 C, 0.2 C and 0.1 C, respectively. In contrast to the men, the female subjects wearing the MCS and Steel vests had similar cooling responses in which the core temperature remained elevated and oral and ear canal temperatures did not drop. The LET active garment cooled most of the female subjects in this study; rectal, oral and ear temperature decreased about 0.2 C, 0.3 C and 0.3 C, respectively. These results show that the garment configurations tested do not elicit a similar thermal response in all subjects. A gender difference is evident. The LET active garment configuration was most effective in decreasing temperatures of the female subjects; the MCS vest was least effective. For male subjects, the three vests appear to be more nearly equivalent. The active garment system under study included a cooling cap, which may account for some of the difference in response.

Ku, Yu-Tsuan E.↗