Search NASASearch

SEARCH · Search NASA

Results for “CLOCK”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Low-Jitter Clock Receivers for Fast Timing Applications

Precision timing is a key requirement for emerging 4D particle tracking, Positron Emission Tomography (PET), beam and fusion plasma diagnostics, and other systems. Time-to-Digital Converters (TDCs) are commonly used to provide digital estimates of the relative timing between events, but the jitter performance of a TDC can be no better than the performance of the circuits that acquire the pulses and deliver them to the TDC. Several clock receiver and distribution circuits were evaluated, and a differential amplifier with resistive loads driving a pseudo-differential clock distribution network, developed using design guidelines for radiation tolerance and cryogenic compatibility, was fabricated as part of three prototypes: an analog front-end testbed chip for high-precision timing pixel readout, a dedicated TDC evaluation chip, and a Low-Gain Avalanche Detector (LGAD) readout circuit. Based on TDC measurements of the prototypes, we infer that the jitter added by the clock receiver and distribution circuits is less than 2.25 ps-rms. This performance meets the requirements of many future precision timing systems. The clock receiver and on-chip pseudo-differential driver were fabricated in commercial 28-nm CMOS technology and occupy 2288 µm 2 .

47 OTHER INSTRUMENTATION

The development of a Kalman filter clock predictor

A Kalman filter based clock predictor is developed, and its performance evaluated using both simulated and real data. The clock predictor is shown to possess a neat to optimal Prediction Error Variance (PEV) when the underlying noise consists of one of the power law noise processes commonly encountered in time and frequency measurements. The predictor's performance is the presence of multiple noise processes is also examined. The relationship between the PEV obtained in the presence of multiple noise processes and those obtained for the individual component noise processes is examined. Comparisons are made with a simple linear clock predictor. The clock predictor is used to predict future values of the time offset between pairs of NPL's active hydrogen masers.

clock predictor

Compact Microwave Mercury Ion Clock for Space Applications

We review progress in developing a small Hg ion clock for space operation based on breadboard ion-clock physics package where Hg ions are shuttled between a quadrupole and a 16-pole rf trap. With this architecture we have demonstrated short-term stability approx.1-2x10(exp -13) at 1 second, averaging to 10-15 at 1 day. This development shows that H-maser quality stabilities can be produced in a small clock package, comparable in size to an ultra-stable quartz oscillator required or holding 1-2x10(exp -13) at 1 second. We have completed an ion clock physics package designed to withstand vibration of launch and are currently building a approx. 1 kg engineering model for test. We also discuss frequency steering software algorithms that simultaneously measure ion signal size and lamp light output, useful for long term operation and self-optimization of microwave power and return engineering data.

navigation

Miniaturized Mercury Ion Clock for Ultrastable Deep Space Applications

We have recently completed a prototype ion-clock physics package based on Hg ions shuttled between a quadrupole and a 16-pole rf trap. With this architecture we have demonstrated short-term stability ~2-3x10-13 at 1 second, averaging to 10-15 at 1 day. This development shows that H-maser quality stabilities can be produced in a small clock package, comparable in size to an ultra-stable quartz oscillator required for holding 1-2x10-13 at 1 second. This performance was obtained in a sealed vacuum configuration where only a getter pump was used to maintain vacuum. The vacuum tube containing the traps has now been under sealed vacuum conditions for nearly 1.5 years with no measurable degradation of ion trapping lifetimes or clock short-term performance. Because the tube is sealed, the Hg source and Neon buffer gas are held indefinitely, for the life of the tube. There is no consumption of Hg in this system unlike in a Cs beam tube where lifetime is often limited by Cs depletion.

mercury ion clocks

New experiments on the effect of clock shifts on homing in pigeons

The effect of clock shifts as an experimental tool for predictably interfering with the homing ability of birds is discussed. Clock shifts introduce specific errors in the birds' sun azimuth compass, resulting in corresponding errors during initial orientation and possibly during orientation enroute. The effects of 6 hour and 12 hour clock shifts resulted in a 90 degree deviation and a 180 degree deviation from the initial orientation, respectively. The method for conducting the clock shift experiments and results obtained from previous experiments are described.

Schmidt-Koenig, K.

Inexpensive programmable computer clock

Clock's computer interface accepts pulses from computer (computer commands) and translates them into control signals for clock, and vice versa. Clock is preset by computer to a fixed number of time pulses, and then started. After fixed number of time pulses has occured, clock reads pulse (via interface) to computer and stops.

Vrancik, J. E.

Clock synchronization experiments performed via the ATS-1 and ATS-3 satellites.

Clock synchronization experiments were carried out May 10 to June 10, 1971, via the ATS-1 and ATS-3 geostationary satellites between the NASA tracking stations at Rosman, N.C., and Mojave, Calif., in order to determine the offset and the relative drift rate between the two station clocks. Pulses at C band with very sharp risetime and of 10 microsec duration were exchanged by the two stations through the dual transponders of the satellites. At each station, a time-interval counter was started by the transmitted pulse and stopped by the pulse received via satellite from the other station. The probable error of the clock offset as measured by the counter is 10 msec. A very long baseline interferometer experiment was also performed between the two stations at the same time and provided independent clock-offset data to check the accuracy of the time-synchronization experiment.

Ramasastry, J.

Government and industry interactions in the development of clock technology

It appears likely that everyone in the time and frequency community can agree on goals to be realized through the expenditure of resources. These goals are the same as found in most fields of technology: lower cost, better performance, increased reliability, small size and lower power. Related aspects are examined in the process of clock and frequency standard development. Government and industry are reviewed in a highly interactive role. These interactions include judgements on clock performance, what kind of clock, expenditure of resources, transfer of ideas or hardware concepts from government to industry, and control of production. Successful clock development and production requires a government/industry relationship which is characterized by long-term continuity, multidisciplinary team work, focused funding and a separation of reliability and production oriented tasks from performance improvement/research type efforts.

Hellwig, H.

Atomic and gravitational clocks

Atomic and gravitational clocks are governed by the laws of electrodynamics and gravity, respectively. While the strong equivalence principle (SEP) assumes that the two clocks have been synchronous at all times, recent planetary data seem to suggest a possible violation of the SEP. Past analysis of the implications of an SEP violation on different physical phenomena revealed no disagreement. However, these studies assumed that the two different clocks can be consistently constructed within the framework. The concept of scale invariance, and the physical meaning of different systems of units, are now reviewed and the construction of two clocks that do not remain synchronous - whose rates are related by a non-constant function beta sub a - is demonstrated. The cosmological character of beta sub a is also discussed.

Canuto, V. M.

Time maintenance of user clocks via the tracking and data relay satellite system

A system is described which uses the Tracking and Data Relay Satellite System (TDRSS) itself to compare the user satellite clock with a clock at the White Sands station that is referenced to Universal Time Coordinated (UTC). No command of the spacecraft by the system is required, and actual on-board clock corrections are made by the spacecraft control center at its discretion. Computer models were constructed using basic orbital parameters for user and TDRS satellites. With only first-order corrections and simple averaging techniques for constant clock rates, error measurement precision of better than one microsecond was obtained. More sophisticated computations should allow considerable improvement over this.

Whitworth, G.

NAVEX: A space shuttle experiment with atomic clocks

A navigation and time transfer experiment (NAVEX) to be flown within the payload of the first German Spacelab mission D-1 is discussed. The objectives of the experiment are to synchronize distant ground stations with an accuracy of better than 10 nsec and to demonstrate one way ranging with an accuracy of better than 30 m. Spread spectrum signals are used and the related technique is tested. On board a Cs and a Rb clock is used. The relativistic effect of these clocks is about -25 microsec per day. On the ground at least two receiving stations and one transmitting-receiving station will be installed. The synchronization of the ground clocks by shuttle signals is compared to those achieved with clock transportations and with GPS measurements. A system description of this experiment is given containing details on the technical concept, the hardware and the planned data evaluation. The present state of the preparatory work is briefly reviewed.

Starker, S.

Search for evidence of a clock related to the solar 154 day complex of periodicities

Evidence that has recently been compiled (Bai and Sturrock 1991) indicates that the enigmatic 154-day periodicity in solar activity may be viewed as part of a complex of periodicities that are approximate multiples of 25.8 days, suggesting that the Sun contains a 'clock' with frequency in the range 440 to 463 nano Hz. The clock may comprise either an oscillator or a rotator, each of which may be either real or virtual. We have reconsidered a previous spectrum analysis of the Zurich sunspot-number sequence by Knight, Schatten, and Sturrock (1979) which revealed a sharp, persistent and significant periodicity with a period of 12.072 days, corresponding to a frequency of about 958.8 nano Hz. This periodicity may be regarded as the (second) upper sideband of the second harmonic (2nu(sub R) + 2nu(sub E)) of a fundamental frequency of 447.7 nano Hz that is clearly within the search band. In this expression, nu(sub R) is the sidereal frequency of the hypothetical rotator and nu(sub E) is the frequency (31.69 nano Hz) of the Earth in its orbital motion around the Sun. In analyzing sunspot area data derived from the Greenwich data set, and on noting that any frequency is defined only to within the Nyquist frequency, we find clear evidence not only for the upper sideband of the second harmonic, but also for the second harmonic (2nu(sub R)) and the lower sideband of the second harmonic (2nu(sub R) - 2nu(sub E)). There is no strong peak at the fundamental frequency in the Greenwich data, but there is in the Zurich sunspot data. The effect of a linear oscillator is, to the lowest order in the amplitude, the same as the combined effect of two rotators of opposite polarities. A rotator that has arbitrary orientation with respect to the ecliptic may influence the outer layers of the Sun and thereby modulate the occurrence of solar activity such as sunspots. By analyzing a simple model, we find that such a rotator would influence surface activity in such a way that the spectrum of a 'signal' (such as the record of sunspots), as seen from the Earth, would contain components with frequencies that are certain integral combinations of nu(sub R) and nu(sub E). The amplitudes of the various components depend sensitively on theta, the angle between the axis of the rotator and the axis of the Earth's orbital motion. This simple model therefore offers a kinematical (but not dynamical) interpretation of the sunspot spectrum. The present analysis, while offering support of our conjectures that the Sun contains a clock that regulates the 154-day complex of periodicities, cannot distinguish between an osillator or a rotator (that might be a traveling wave), nor between a real rotator or a virtual rotator (that might be an apparent traveling wave due to the aliasing effect of an oscillator in a rotating system). Further analysis of sunspot and other data sets will be required to confirm the existence of such clock and (if it is real) to determine its physical nature.

Sturrock, P. A.

Timescale algorithms combining cesium clocks and hydrogen masers

The United States Naval Observatory (USNO) atomic timescale, formerly based on an ensemble of cesium clocks, is now produced by an ensemble of cesium clocks and hydrogen masers. In order to optimize stability and reliability, equal clock weighting has been replaced by a procedure reflecting the relative, time-varying noise characteristics of the two different types of clocks. Correlation of frequency drift is required, and residual drift is avoided by the eventual complete deweighting of the masers.

Lee A. Breakiron

Frequency stability of GPS NAVSTAR block 1 and block 2 on-orbit clocks

Analysis of the frequency stability of the on-orbit NAVSTAR clocks os performed by the Naval Research Laboratory. The frequency stability is presented for sample times of one day to 30 days. Composite frequency stability profiles are presented for Block 1 and Block 2 NAVSTAR clocks. Several NAVSTAR cesium clocks show frequency stabilities of a few parts in 10^(14) for long sample times. Time-domain noise-process analysis shows the dominant noise type to be white frequency noise for sample times of one to ten days. The non-stationary stochastic behavior of one of the cesium clocks, illustrated by its frequency stability history, shows that the frequency stability is not always time-invariant.

Thomas B. Mccaskill

Experimental comparison of time synchronization techniques by means of light signals and clock transport on the rotating earth

An experiment was conducted to investigate the equivalence of two methods of time transfer in a noninertial reference frame: by means of an electromagnetic signal using laser light pulses and by means of the slow ground transport of a hydrogen maser atomic clock. The experiment may also be interpreted as an investigation of whether the one-way speeds of light in the east-west and west-east directions on the rotating earth are the same. The light pulses were sent from a laser coupled to a telescope at the NASA Goddard Optical Research Facility (GORF) in Greenbelt, Maryland to the U.S. Naval Observatory (USNO) in Washington, DC. The optical path was made possible by a 30-cm flat mirror on a water tower near GORF and a 25-cm flat mirror on top of the Washington National Cathedral near USNO. The path length was 26.0 km with an east-west component of 20.7 km. The pulses were reflected back over the same path by a portable array of corner cube reflectors. The transmission and return times were measured with a stationary Sigma Tau hydrogen maser and a University of Maryland event timer at GORF, while the times of reflection were measured with a similar maser and event timer combination carefully transported to USNO. Both timekeeping systems were housed in highly insulated enclosures and were maintained at constant temperatures to within +/- 0.1 C by microprocessor controllers. The portable system was also protected from shock and vibration by pneumatic supports. The difference delta(T) between the directly measured time of reflection according to the portable clock and the time of reflection calculated from the light pulse signal times measured by the stationary clock was determined. For a typical trip delta(T) is less than 100 ps and the corresponding limit on an anisotropy of the one-way speed of light is delta(c/c) is less than 1.5 x 10(exp -6). This the only experiment to date in which two atomic clocks were calibrated at one location, one was slowly transported to the other end of a path, and the times of transmission, reflection, and return of short light pulses sent in different directions along the path were registered.

Nelson, R. A.

Time scale algorithms for an inhomogeneous group of atomic clocks

Through the past 17 years, the time scale requirements at the National Research Council (NRC) have been met by the unsteered output of its primary laboratory cesium clocks, supplemented by hydrogen masers when short-term stability better than 2 x 10(exp -12)tau(sup -1/2) has been required. NRC now operates three primary laboratory cesium clocks, three hydrogen masers, and two commercial cesium clocks. NRC has been using ensemble averages for internal purposes for the past several years, and has a realtime algorithm operating on the outputs of its high-resolution (2 x 10(exp -13) s at 1 s) phase comparators. The slow frequency drift of the hydrogen masers has presented difficulties in incorporating their short-term stability into the ensemble average, while retaining the long-term stability of the laboratory cesium frequency standards. We report on this work on algorithms for an inhomogeneous ensemble of atomic clocks, and on our initial work on time scale algorithms that could incorporate frequency calibrations at NRC from the next generation of Zacharias fountain cesium frequency standards having frequency accuracies that might surpass 10(exp -15), or from single-trapped-ion frequency standards (Ba+, Sr+,...) with even higher potential accuracies. The requirements for redundancy in all the elements (including the algorithms) of an inhomogeneous ensemble that would give a robust real-time output of the algorithms are presented and discussed.

Jacques, C.