Search NASA⌕ Search

SEARCH · Search NASA

Results for “CLOTHING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Graphite cloth facilitates vacuum evaporation of silicon monoxide

Woven graphite cloth facilitates the vacuum deposition of thin films of silicon monoxide on substrate surfaces. The cloth serves both as a container and electric heating element for the silicon monoxide. It minimizes and prevents the silicon monoxide particle ejection, provides uniform heat distribution, and cools rapidly by radiation.

Carithers, M. D.↗

Development of a carbon cloth heat post module for thermal vacuum testing of a spinning spacecraft

Development of a high temperature, high power density, isothermal, rapid transient, infrared thermal module is described. The investigation of various alternative approaches is discussed, as well as the rationale leading to the choice of a carbon cloth concept. Evolution of module design configurations and a summary of the development test results are included, along with a detailed description of the final design, which incorporated a black plate emitter radiantly heated by the carbon cloth. The final module configuration met design criteria during a 200-hour thermal vacuum performance test at 1000 F operating temperature without contaminating a solar cell array.

Levine, M. B.↗

Evaluation of a multifiltration water reclamation subsystem to reclaim domestic clothes wash water

An evaluation has been performed of a multifiltration water reclamation subsystem to determine its capability to recover water from domestic clothes wash water. A total of 32.89 kg (72.5 lb) of clothes were washed during eight wash cycles which used 1.4 lb of detergent, 145 gallons of hot water and 133.9 gallons of cold water. Water recovered at a weighted average process rate of 3.81 gallons per hour met the majority of the 23 requirements established for potable water by the U.S. Public Health Service. Average power consumed during this evaluation was approximately 71 watt-hours per gallon of water recovered. Filter replacement, which was required primarily for the control of micro-organisms in the recovered water averaged 4.86 filters per 100 gallons of wash water processed. The subsystem removed approximately 98 percent and virtually 100 percent of the phosphates and surfactants, respectively, from the wash water.

Hall, J. B., Jr.↗

Tests of protective clothing for the safe handling of pressurized lamps

Tests were made to find a clothing material combination for use in handling high-pressure lamps. Monofilament nylon, ballistic nylon, and ballistic felt grouped into various multilayer combinations and chromed leather were positioned around and 30 cm (12 in.) away from exploding high-pressure lamps of different manufacturers and wattages. The results are: (1) 5024 nylon/ballistic felt/5024 nylon in a layered configuration was not penetrated by fragments of lamps as large as 6.5 kW; (2) this layered combination is lightweight and pliable and offers greater mobility and comfort to the user than previous protective clothing; and (3) Lexan plastic 1.6 mm (1/6 in.) thick to be used for face shield material showed no penetration for lamps as large as 20 kW.

Ewashinka, J. G.↗

Clothing and personal hygiene

The biomedical maintenance of astronauts is discussed in terms of personal hygiene. Principal characteristics and general requirements are described which must be followed in perfecting a system of hygienic practices and in devising means to maintain personal hygiene, flight clothing, underwear, bedding, and medical-domestic equipment for manned space flights of varying durations. Factors discussed include: disposable clothing, thermal protection, oral hygiene, cleansing of the skin, and grooming of the hair.

Finogenov, A. M.↗

Carbon Cloth Supports Catalytic Electrodes

Carbon cloth is starting material for promising new catalytic electrodes. Carbon-cloth electrodes are more efficient than sintered-carbon configuration previously used. Are also chemically stable and require less catalyst--an important economic advantage when catalyst is metal such as platinum.

Lu, W. T. P.↗

Effects of bleeder cloth impressions on the use of polar backscatter to detect porosity

The influence of the nature of the composite's surface on ultrasonic polar backscatter measurements for detecting and characterizing porosity in composite laminates is studied, focusing on the effects of bleeder cloth impressions noted by Bar-Cohen (1987). The results indicate that the presence of the bleeder cloth impressions substantially influences the degree of anisotropy. It is found that, for relatively thin samples in which selective time gating is not feasible, the state of the insonified surface and the state of the back surface both influence the received signal.

Handley, S. M.↗

A method for the compensation of the effects of surface cloth impressions on polar backscatter applied to porous epoxy and biaxial graphite/epoxy composites

The anisotropy of polar backscatter from graphite/epoxy composites is a potentially useful parameter for the characterization of porosity levels. However, the effects of release-cloth impressions on measured integrated polar backscatter levels are sufficient to inhibit the detection of porosity with this method. Recently, we developed a theoretical model to predict the frequency distribution of the backscattered power along the high-symmetry directions of release-cloth impressions. This study investigates experimentally the usefulness of limiting the bandwidth to regions not dominated by the scattering from the surface impressions, hence increasing the probability of detecting flaws such as porosity.

Madaras, Eric I.↗

Data on Material Properties and Panel Compressive Strength of a Plastic-bonded Material of Glass Cloth and Canvas

Results are presented of tests for determining the tensile, compressive, and bending properties of a material of plastic-bonding glass cloth and canvas layers. In addition, 10 panel specimens were tested in compression. Although the material is not satisfactory for primary structural use in aircraft when compared on a strength-weight basis with other materials in common use, there appears to be potential strength in the material that will require research for development. These points are considered in some detail in the concluding discussion of the report. An appendix shows that a higher tensile strength can be obtained by changes in the type of weave used in the glass-cloth reinforcement.

MATERIALS, PLASTIC-STRENGTH↗

Exploratory Engine Test of Transpiration-cooled Turbine-rotor Blade with Wire-cloth Shell

Engine tests were made on a transpiration-cooled blade that was fabricated from an internal load-carrying member with an external surface of wire cloth. After operation in the engine, some damage was noted at the tip region of the trailing edge of the blades. On other sections of the blade, the wire cloth did not appear greatly overheated, and it appeared that satisfactory chordwise temperature distribution was provided by orifices in the blade base.

ENGINES, COOLING↗

Properties and processing characteristics of low density carbon cloth phenolic composites

Ply-lift and pocketing are two critical anomalies of carbon cloth phenolic composites (CCPC) in rocket nozzle applications. Ply lift occurs at low temperatures when the A/P and in-plane permeabilities of the composite materials are still very low and in-plane porous paths are blocked. Pocketing occurs at elevated temperatures when in-plane permeability is reduced by the A/P compressive stress. The thermostructural response of CCPC in a rapid heating environment involves simultaneous heat, mass, and momentum transfer along with the degradation of phenolic resin in a multiphase system with temperature- and time-dependent material properties as well as dynamic processing conditions. Three temperature regions represent the consequent chemical reactions, material transformations, and property transitions, and provide a quick qualitative method for characterizing the thermostructural behavior of a CCPC. In order to optimize the FM5939 LDCCP (low density carbon cloth phenolic) for the nozzle performance required in the Advanced Solid Rocket Motor (ASRM) program, a fundamental study on LDCCP materials was conducted. The cured composite has a density of 1.0 +/- 0.5 gm/cc which includes 10 to 25 percent void volume. The weight percent of carbon microballoon is low (7-15 percent). However, they account for approximately one third of the volume and historically their percentages have not been controlled very tightly. In addition, the composite properties show no correlation with microballoon weight percent or fiber properties (e.g. fiber density or fiber moisture adsorption capacity). Test results concerning the ply-lift anomaly in the MNASA motor firings were: (1) Steeper ply angle (shorter path lenght) designs minimized/eliminated by lifting, (2) material with higher void volume ply lifted less frequently, (3) materials with high (greater than 9 percent) microballoon content had a higher rate of ply lifting, and (4) LDCCP materials failed at microballoon-resin interfaces. The objectives of this project are: (1) to investigate the effects of carbon microballoon and cabosil fillers as well as fiber heat treatment on plylift-related mechanical properties, (2) to develop a science-based thermostructural process model for the carbon phenolics. The model can be used in the future for the selection of the improved ASRM materials, (3) to develop the micro-failure mechanisms for the ply-lift initiation and propagation processes during the thermoelastic region of phenolic degradation, i.e. postcuring and devolatilization.

Wang, C. Jeff↗

Waterless Clothes-Cleaning Machine

A waterless clothes-cleaning machine has been developed that removes loose particulates and deodorizes dirty laundry with regenerative chemical processes to make the clothes more comfortable to wear and have a fresher smell. This system was initially developed for use in zero-g, but could be altered for 1-g environments where water or other re sources are scarce. Some of these processes include, but are not limited to, airflow, filtration, ozone generation, heat, ultraviolet light, and photocatalytic titanium oxide.

Johnson, Glenn↗

REACCH - Reactive Electro-Adhesive Capture ClotH Mechanism to Enable Safe Grapple of Cooperative/Non-Cooperative Space Debris

USC’s Space Engineering Research Center (SERC) and the Jet Propulsion Laboratory (JPL) have created a unique “octopus” tentacle end effector for robotic systems that uses formable electro-adhesion (EA) and Gecko adhesion capture cloth material. REACCH, or Reactive Electro-Adhesive Capture ClotH, supports soft capture of objects of any size, shape, surface finish or material on-orbit. To-date SERC/JPL have developed initial tentacles and backing spines that can control the EA/G material. Prototypes with two tentacles have been demonstrated and tested on a 3-DOF air bearing device in 1g in one plane of grip. The results show promise to further develop this new type of grappling mechanism able to make first soft contact with an object, with a technology that merges compliance and control elements for future on-orbit servicing and assembly missions. This paper presents the initial design and test results on this type of system.

Narayanan, Sriram↗

Thermoelectric Heat Pump Clothes Dryer using Secondary Loop Heat Exchangers: Experimental Evaluation

Past work has shown that thermoelectric clothes dryers are capable of much higher efficiency than electric resistance clothes dryers. In an effort to improve performance and reduce material utilization, this work explores a new secondary loop system configuration. In this configuration, heat is transferred between air and the thermoelectric heat pumps via two water loops and two water-to-air fin-tube type heat exchangers. In this work, performance is investigated and analyzed using experimental data.

Patel, Viral K.↗

Performance Modeling of a Thermoelectric Heat Pump Clothes Dryer with Very High Air Flow

Previous research has shown that a clothes dryer heated by thermoelectric (Peltier) heat pumps can be up to 85% more efficient than a conventional electric-resistance dryer. A previous thermoelectric prototype used a conventional dryer’s air flow of 120 ft3/min (0.06 m3/s) and provided about 1,300 W of thermoelectric heating capacity at a heating coefficient of performance (COP) of approximately 1.2. In this work, the performance of a clothes dryer with a very high air flow rate, up to 300 ft3/min (1.14 m3/s), and only 400 W of thermoelectric heating capacity was investigated using a thermohydraulic model. Key aspects of the model were validated experimentally. Results for dry time and efficiency are presented for various air flow and heating rates.

Boudreaux, Philip↗

Selective Removal of Perfluorobutyric Acid Using an Electroactive Ion Exchanger Based on Polypyrrole@Iron Oxide on Carbon Cloth

Perfluorabutyric acid (PFBA) is one classify of perfluoroalkyl and polyfluoroalkyl substances (PFASs), which is applied to wide-spread industry compounds. The removal of PFBA has attracted considerable scientific interest in recent decades because it caused environmental pollutions and human diseases. For removing PFASs from wastewater, the adsorption method has been commonly used for the remediation of PFASs. However, it is usually limited by the inevitable “secondary waster” produced in this treatment process. In this work, PFBA can be removed effectively by synergizing the electrically switched ion exchange (ESIX) and a novel nanostructured ion exchanger. Herein, the nanostructured ion exchanger is designed by coating polypyrrole (PPy) @ Fe 2 O 3 nanoneedle on carbon cloth (PPy@Fe 2 O 3 NN-CC). Overall, results show that PPy@Fe 2 O 3 NN-CC film enhances ion exchange speed and efficiency, which endures its high-capacity adsorption ability and rapid regeneration property, thereby reducing secondary waste. Moreover, ESIX based on PPy@Fe 2 O 3 NN-CC has high selectivity for adsorption of PFBA over Cl - , SO 4 2- and NO 3 - .

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Shielding properties of lead-free protective clothing and their impact on radiation doses

The shielding properties of two different lead-free materials--tin and a compound of 80% tin and 20% bismuth--for protective clothing are compared with those of lead for three typical x-ray spectra generated at tube voltages of 60, 75, and 120 kV. Three different quantities were used to compare the shielding capability of the different materials: (1) Air-kerma attenuation factors in narrow-beam geometry, (2) air-kerma attenuation factors in broad-beam geometry, and (3) ratios of organ and effective doses in the human body for a whole-body irradiation with a parallel beam directed frontally at the body. The thicknesses of tin (0.45 mm) and the tin/bismuth compound (0.41 mm) to be compared against lead correspond to a lead equivalence value of 0.35 mm for the 75 kV spectrum. The narrow-beam attenuation factors for 0.45 mm tin are 54% and 32% lower than those for 0.35 mm lead for 60 and 120 kV; those for 0.41 mm tin/bismuth are 12% and 32% lower, respectively. The decrease of the broad-beam air-kerma attenuation factors compared to lead is 74%, 46%, and 41% for tin and 42%, 26%, and 33% for tin/bismuth and the spectra at 60, 75, and 120 kV, respectively. Therefore, it is recommended that the characterization of the shielding potential of a material should be done by measurements in broad-beam geometry. Since the secondary radiation that is mainly responsible for the shielding reduction in broad-beam geometry is of low penetrability, only more superficially located organs receive significantly enhanced doses. The increase for the dose to the glandular breast tissue (female) compared to being shielded by lead is 143%, 37%, and 45% when shielded by tin, and 35%, 15%, and 39% when shielded by tin/bismuth for 60, 75, and 120 kV, respectively. The effective dose rises by 60%, 6%, and 38% for tin, and 14%, 3% and, 35% for tin/bismuth shielding, respectively.

61 RADIATION PROTECTION AND DOSIMETRY↗