At least 91 records · Page 5

Charge collection and electrical characterization of neutron irradiated silicon pad detectors for the CMS High Granularity Calorimeter

The replacement of the existing endcap calorimeter in the Compact Muon Solenoid (CMS) detector for the high-luminosity LHC (HL-LHC), scheduled for 2027, will be a high granularity calorimeter. It will provide detailed position, energy, and timing information on electromagnetic and hadronic showers in the immense pileup of the HL-LHC. The High Granularity Calorimeter (HGCAL) will use 120-, 200-, and 300-$\mu\textrm{m}$ thick silicon (Si) pad sensors as the main active material and will sustain 1-MeV neutron equivalent fluences up to about $10^{16}~\textrm{n}_\textrm{eq}\textrm{cm}^{-2}$. In order to address the performance degradation of the Si detectors caused by the intense radiation environment, irradiation campaigns of test diode samples from 8-inch and 6-inch wafers were performed in two reactors. Characterization of the electrical and charge collection properties after irradiation involved both bulk polarities for the three sensor thicknesses. Since the Si sensors will be operated at -30 $^\circ$C to reduce increasing bulk leakage current with fluence, the charge collection investigation of 30 irradiated samples was carried out with the infrared-TCT setup at -30 $^\circ$C. TCAD simulation results at the lower fluences are in close agreement with the experimental results and provide predictions of sensor performance for the lower fluence regions not covered by the experimental study. All investigated sensors display 60$\%$ or higher charge collection efficiency at their respective highest lifetime fluences when operated at 800 V, and display above 90$\%$ at the lowest fluence, at 600 V. The collected charge close to the fluence of $10^{16}~\textrm{n}_\textrm{eq}\textrm{cm}^{-2}$ exceeds 1 fC at voltages beyond 800 V.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Test beam performance measurements for the Phase I upgrade of the CMS pixel detector

A new pixel detector for the CMS experiment was built in order to cope with the instantaneous luminosities anticipated for the Phase~I Upgrade of the LHC. The new CMS pixel detector provides four-hit tracking with a reduced material budget as well as new cooling and powering schemes. A new front-end readout chip mitigates buffering and bandwidth limitations, and allows operation at low comparator thresholds. Here in this paper, comprehensive test beam studies are presented, which have been conducted to verify the design and to quantify the performance of the new detector assemblies in terms of tracking efficiency and spatial resolution. Under optimal conditions, the tracking efficiency is $99.95\pm0.05\,\%$, while the intrinsic spatial resolutions are $4.80\pm0.25\,\mu \mathrm{m}$ and $7.99\pm0.21\,\mu \mathrm{m}$ along the $100\,\mu \mathrm{m}$ and $150\,\mu \mathrm{m}$ pixel pitch, respectively. The findings are compared to a detailed Monte Carlo simulation of the pixel detector and good agreement is found.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design, simulation, fabrication, and preliminary tests of 3D CMS pixel detectors for the super-LHC

The Super-LHC upgrade puts strong demands on the radiation hardness of the innermost tracking detectors of the CMS, which cannot be fulfilled with any conventional planar detector design. The so-called 3D detector architectures, which feature columnar electrodes passing through the substrate thickness, are under investigation as a potential solution for the closest operation points to the beams, where the radiation fluence is estimated to reach 10{sup 16} n{sub eq}/cm{sup 2}. Two different 3D detector designs with CMS pixel readout electronics are being developed and evaluated for their advantages and drawbacks. The fabrication of full-3D active edge CMS pixel devices with p-type substrate has been successfully completed at SINTEF. In this paper, we study the expected post-irradiation behaviors of these devices with simulations and, after a brief description of their fabrication, we report the first leakage current measurement results as performed on wafer.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The construction of the phase-1 upgrade of the CMS pixel detector

The innermost layers of the original CMS tracker were built out of pixel detectors arranged in three barrel layers and two forward disks in each endcap. The original CMS detector was designed for the nominal instantaneous LHC luminosity of 1×10 34 cm -2 s -1 . Under the conditions expected in the coming years, which will see an increase of a factor two of the instantaneous luminosity, the CMS pixel detector would have seen a dynamic inefficiency caused by data losses due to buffer overflows. For this reason the CMS collaboration has installed a replacement pixel detector during the recent extended end of year shutdown. The phase-1 upgrade of the CMS pixel detector will operate at high efficiency at an instantaneous luminosity of 2×10 34 cm -2 s -1 with increased detector acceptance and additional redundancy for the tracking, while at the same time reducing the material budget. These goals are achieved using a new read-out chip and modified powering and read-out schemes, one additional tracking layer both in the barrel and in the disks, and new detector supports including a CO 2 based evaporative cooling system, that contribute to the reduction of the material in the tracking volume. This contribution will review the design and technological choices of the phase-1 detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurement of the background in the CMS muon detector in ${p}{p}$-collisions at $\sqrt{s} = 13$ TeV

The CMS detector, including its muon system, has been operating at the CERN LHC in increasingly challenging conditions for about 15 years. The muon detector was designed to provide excellent triggering and track reconstruction for muons produced in proton–proton collisons at an instantaneous luminosity ($\mathcal{L}$) of 1 x 10 34 cm –2 s –1 . During the Run 2 data-taking period (2015–2018), the LHC achieved an instantaneous luminosity of twice its design value, resulting in larger background rates and making the efficient detection of muons more difficult. While some backgrounds result from natural radioactivity, cosmic rays, and interactions of the circulating protons with residual gas in the beam pipe, the dominant source of background hits in the muon system arises from proton–proton interactions themselves. Charged hadrons leaving the calorimeters produce energy deposits in the muon chambers. In addition, high-energy particles interacting in the hadron calorimeter and forward shielding elements generate thermal neutrons, which leak out of the calorimeter and shielding structures, filling the CMS cavern. We describe the method used to measure the background rates in the various muon subsystems. These rates, in conjunction with simulations, can be used to estimate the expected backgrounds in the High-Luminosity LHC. This machine will run for at least 10 years starting in 2029 reaching an instantaneous luminosity of $\mathcal{L}$ = 5 x 10 34 cm –2 s –1 and increasing ultimately to $\mathcal{L}$ = 7.5 x 10 34 cm –2 s –1 . These background estimates have been a key ingredient for the planning and design of the muon detector upgrade.

Tytgat, M. (ORCID:0000000239902074)↗

Study of the B{sub s} meson with forthcoming LHC data at CMS

A study of the properties of the B{sub s} meson decays has been done using a full Monte Carlo simulation of the CMS detector. The CMS pixel detector allows a precise measurement of the B{sub s} decay vertices which are displaced from the proton-proton interaction point. This facilitates a time dependent analysis of the angular correlations between the B{sub s} decay products. In particular, the decay B{sub s{yields}}(J/{psi}){phi}{yields}{mu}{sup +{mu}-}K{sup +}K{sup -} enables measurements of the width difference between heavy and light mass eigenstates. Furthermore, it permits a measurement of the CP violating phase {phi}{sub s} which is sensitive to physics beyond the Standard Model.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Simulation and laboratory test results of 3D CMS pixel detectors for HL-LHC

The CMS pixel detector is the innermost tracking device at the LHC, reconstructing interaction vertices and charged particle trajectories. The current planar sensors located in the innermost layer of the pixel detector will be exposed to very high fluences which will degrade their performances. As a possible replacement for planar pixel sensors in the High Luminosity-LHC (HL-LHC), 3D silicon technology is under consideration due to its expected good performance in harsh radiation environments. Studies are also in progress for using 3D silicon pixel detectors in near-beam proton spectrometers at the LHC. Deep Reactive Ion Etching (DRIE) plays a key role in fabricating 3D silicon detectors in which readout and ohmic electrodes are processed through the silicon substrate instead of being implanted on the silicon surface. 3D pixel devices considered in this study were processed at FBK (Trento, Italy), bump bonded to the CMS pixel readout chip, and characterized in the laboratory. Numerical simulations were also carried out. We report on selected results from laboratory measurements and TCAD simulations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Phase-2 Upgrade of the CMS Data Acquisition

The High Luminosity LHC (HL-LHC) will start operating in 2027 after the third Long Shutdown (LS3), and is designed to provide an ultimate instantaneous luminosity of 7:5 × 10$^{34}$ cm$^{-2}$ s$^{-1}$, at the price of extreme pileup of up to 200 interactions per crossing. The number of overlapping interactions in HL-LHC collisions, their density, and the resulting intense radiation environment, warrant an almost complete upgrade of the CMS detector. The upgraded CMS detector will be read out by approximately fifty thousand highspeed front-end optical links at an unprecedented data rate of up to 80 Tb/s, for an average expected total event size of approximately 8 - 10 MB. Following the present established design, the CMS trigger and data acquisition system will continue to feature two trigger levels, with only one synchronous hardware-based Level-1 Trigger (L1), consisting of custom electronic boards and operating on dedicated data streams, and a second level, the High Level Trigger (HLT), using software algorithms running asynchronously on standard processors and making use of the full detector data to select events for offline storage and analysis. The upgraded CMS data acquisition system will collect data fragments for Level-1 accepted events from the detector back-end modules at a rate up to 750 kHz, aggregate fragments corresponding to individual Level- 1 accepts into events, and distribute them to the HLT processors where they will be filtered further. Events accepted by the HLT will be stored permanently at a rate of up to 7.5 kHz. This paper describes the baseline design of the DAQ and HLT systems for the Phase-2 of CMS.

Badaro, Gilbert↗

The phase-1 upgrade of the CMS pixel detector

The pixel detector of the CMS experiment will be upgraded during the extended end of year shutdown during winter 2016/2017. The upgraded detector will operate at full efficiency at an instantaneous luminosity of 2 × 10 34 cm -2 s -1 with increased detector acceptance and additional redundancy for the tracking, while at the same time reducing the material budget. The design and technological choices will be reviewed, and the status of the construction of the detector and the performance of its components as measured in system tests are discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Forward Pixel Detector for the Phase 2 Upgrade of CMS And Module Testing at UIC

High-Luminosity Large Hadron Collider (HL-LHC) upgrade aims to increase performance. In order to efficiently handle the larger particle flux and increased radiation, an upgrade is planned for the inner Tracker of the Compact Muon Solenoid (CMS) detector, which is located at the innermost part of the CMS. To efficiently reconstruct and track particles, the existing pixel tracker will be upgraded with novel sensors, readout chips, and front-end electronics designed to handle increased data rates. These improvements will allow the detector to track particles more precisely. In the United States, we are working on assembling new sensor modules to be inserted into disks, referred to as TFPX, for installation in the CMS detector for the HL-LHC era. We are currently testing the prototype of TFPX modules to ensure the upgrade is carried out in the best way possible. The University of Ilinois Chicago has been tasked with testing the final versions of the TFPX sensor modules before they are sent to CERN to be installed into the CMS detector. This work is supported by NSF.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Performance of the CMS muon detector and muon reconstruction with proton-proton collisions at $\sqrt{s}=$ 13 TeV

The CMS muon detector system, muon reconstruction software, and high-level trigger underwent significant changes in 2013–2014 in preparation for running at higher LHC collision energy and instantaneous luminosity. The performance of the modified system is studied using proton-proton collision data at center-of-mass energy √s=13 TeV, collected at the LHC in 2015 and 2016. The measured performance parameters, including spatial resolution, efficiency, and timing, are found to meet all design specifications and are well reproduced by simulation. Despite the more challenging running conditions, the modified muon system is found to perform as well as, and in many aspects better than, previously. We dedicate this paper to the memory of Prof. Alberto Benvenuti, whose work was fundamental for the CMS muon detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The CMS Phase-1 Pixel Detector Upgrade

The CMS detector at the CERN LHC features a silicon pixel detector as its innermost subdetector. The original CMS pixel detector has been replaced with an upgraded pixel system (CMS Phase-1 pixel detector) in the extended year-end technical stop of the LHC in 2016/2017. The upgraded CMS pixel detector is designed to cope with the higher instantaneous luminosities that have been achieved by the LHC after the upgrades to the accelerator during the first long shutdown in 2013–2014. Compared to the original pixel detector, the upgraded detector has a better tracking performance and lower mass with four barrel layers and three endcap disks on each side to provide hit coverage up to an absolute value of pseudorapidity of 2.5. This paper describes the design and construction of the CMS Phase-1 pixel detector as well as its performance from commissioning to early operation in collision data-taking.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

CRIC and Rucio integration for CMS Data Management

The Large Hadron Collider (LHC) at CERN smashes protons together at close to the speed of light with seven times the energy of the most powerful accelerators built up to now. Some of the collision energy is turned into mass, creating new particles which are observed in the Compact Muon Solenoid (CMS) particle detector. CMS data is analyzed by scientists around the world to build up a picture of what happened at the heart of the collision. This will help us answer questions such as: ”what is the Universe really made of and what forces act within it?” and ”what gives everything substance?”. All the data produced by the experiment are collected and stored in a distributed system, since it must provide an high throughput and performing access to these data to scientists and physicists spread all over the world. In order to answer the previous questions and many others, CMS users must first obtain a copy of a portion of these data, and then to analyze it, therefore the first challenge is to decide in which storage site to save this duplicate so they can access it as quickly as possible. The second issue is each storage site shares a limited memory space with many CMS users, and each one needs to be assigned to a well defined personal amount of storage to pin data he needs. The main goal of my Summer Internship is to make scalable and automatic this user-site mapping which is based on a preexisting policy, proving a structured and organized algorithm to accomplish this task. Hence we are going to define, and solve, the main challenges encountered, and the technical solution used to generalize the algorithm to handle different policies for different countries.

43 PARTICLE ACCELERATORS↗

Precision Timing with the CMS MIP Timing Detector

The Compact Muon Solenoid (CMS) detector at the CERN Large Hadron Collider (LHC) is undergoing an extensive Phase II upgrade program to prepare for the challenging conditions of the High Luminosity LHC (HL-LHC). A new timing layer is designed to measure minimum ionizing particles (MIPs) with a time resolution of 30 ps and hermetic coverage up to a pseudo-rapidity of |η|=3. This MIP Timing Detector (MTD) will consist of a central barrel region based on LYSO:Ce crystals read out with SiPMs and two end-caps instrumented with radiation-tolerant Low Gain Avalanche Detectors (LGADs). The precision time information from the MTD will reduce the effects of the high levels of pile-up expected at the HL-LHC and will bring new and unique capabilities to the CMS detector. The time information assigned to each track will enable the use of 4D-vertexing which will render a 5-fold pile-up reduction thus recovering the current conditions. Precision timing will also enable new time-based isolations and improved b-tagging algorithms. All of this translates into a 20% gain in effective luminosity when looking at di-Higgs boson events decaying to a pair of b-quarks and two photons. We present the current status and ongoing R&D of the MTD, including implications on the physics reach at the HL-LHC and test beam results.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

CMS: Present status, limitations, and upgrade plans

An overview of the CMS upgrade plans will be presented. A brief status of the CMS detector will be given, covering some of the issues we have so far experienced. This will be followed by an overview of the various CMS upgrades planned, covering the main motivations for them, and the various R&D efforts for the possibilities under study. The CMS detector has been working extremely well since the start of data-taking at the LHC as is evidenced by the numerous excellent results published by CMS and presented at this workshop and recent conferences. Less well documented are the various issues that have been encountered with the detector. In the spirit of this workshop I will cover some of these issues with particular emphasis on problems that motivate some of the upgrades to the CMS detector for this decade of data-taking. Though the CMS detector has been working extremely well and expectations are great for making the most of the LHC luminosity, there have been a number of issues encountered so far. Some of these have been described and while none currently presents a problem for physics performance, some of them are expected to become more problematic, especially at the highest Phase 1 luminosities for which the majority of the integrated luminosity will be collected. These motivate upgrades for various parts of the CMS detector so that the current excellent physics performance can be maintained or even surpassed in the realm of the highest Phase 1 luminosities.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Search for long-lived particles decaying in the CMS muon detectors in proton-proton collisions at s = 13 TeV

A search for long-lived particles (LLPs) decaying in the CMS muon detectors is presented. A data sample of proton-proton collisions at s = 13 TeV corresponding to an integrated luminosity of 138 fb − 1 , recorded at the LHC in 2016–2018, is used. The decays of LLPs are reconstructed as high multiplicity clusters of hits in the muon detectors. In the context of twin Higgs models, the search is sensitive to LLP masses from 0.4 to 55 GeV and a broad range of LLP decay modes, including decays to hadrons, τ leptons, electrons, or photons. No excess of events above the standard model background is observed. The most stringent limits to date from LHC data are set on the branching fraction of the Higgs boson decay to a pair of LLPs with masses below 10 GeV. This search also provides the best limits for various intervals of LLP proper decay length and mass. Finally, this search sets the first limits at the LHC on a dark quantum chromodynamic sector whose particles couple to the Higgs boson through gluon, Higgs boson, photon, vector, and dark-photon portals, and is sensitive to branching fractions of the Higgs boson to dark quarks as low as 2 × 10 − 3 . © 2024 CERN, for the CMS Collaboration 2024 CERN

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Detector upgrade R&D of the CMS Hadronic Endcap and Forward calorimeters

The CMS Hadronic Endcap (HE) and Hadronic Forward (HF) calorimeters cover the pseudorapidity range of from 1.4 to 5 on both sides of the CMS detector, contributing to superior jet and missing transverse energy resolutions. Here we discuss possible upgrade scenarios for both calorimeters. Recent studies revealed abnormally high amplitude signals due to punch through charged particles, mostly muons, producing Cherenkov photons at the HF calorimeter PMT window. Our studies show that these events can be eliminated either by using the timing properties, or replacing the HF PMTs with new generation four anode PMTs. As the integrated luminosity of the LHC increases, the scintillator tiles used in the CMS Hadronic Endcap calorimeter will lose their efficiency. This report outlines two possible radiation hard upgrade scenarios based on replacing the HE scintillators with quartz plates.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗