Search NASA⌕ Search

SEARCH · Search NASA

Results for “COLLECTOR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Flat-plate collector performance determined experimentally with a solar simulator

The NASA is constructing a new office building at Langley Research Center that will utilize solar energy for heating and cooling. A collector technology program is described which includes testing collectors in an indoor facility under simulated solar radiation. Tests have been conducted on five collectors to date and performance data are presented. The collector performance obtained with the solar simulator will be correlated with data obtained by conducting tests outdoors at Lewis.

Vernon, R. W.↗

Outdoor flat-plate collector performance prediction from solar simulator test data

Solar collector performance data obtained from tests with a simulator was modified for real-life conditions. The data obtained with the simulator was corrected for the variable conditions of ambient temperature, wind, incident angle, flow rate, etc., that are encountered outdoors. Modification of simulator data was accomplished by combining experiment with theory. The technique was demonstrated by application to a spectrally selective and a nonselective type of collector. This kind of modified simulator collector performance data should be valuable in solar systems analysis and for collector performance ranking based on all-day calculated conditions.

Simon, F. F.↗

Development of flat-plate solar collectors for the heating and cooling of buildings

The relevant design parameters in the fabrication of a solar collector for heating liquids were examined. The objective was to design, fabricate, and test a low-cost, flat-plate solar collector with high collection efficiency, high durability, and requiring little maintenance. Computer-aided math models of the heat transfer processes in the collector assisted in the design. The preferred physical design parameters were determined from a heat transfer standpoint and the absorber panel configuration, the surface treatment of the absorber panel, the type and thickness of insulation, and the number, spacing and material of the covers were defined. Variations of this configuration were identified, prototypes built, and performance tests performed using a solar simulator. Simulated operation of the baseline collector configuration was combined with insolation data for a number of locations and compared with a predicted load to determine the degree of solar utilization.

Ramsey, J. W.↗

Outdoor flat-plate collector performance prediction from solar simulator test data

This paper describes how collector performance obtained from test data with a simulator can be modified for real-life conditions. The approach taken is to correct the performance data obtained with the simulator for the variable conditions of ambient temperature, wind, incident angle, flow rate, etc., that are encountered in outdoor conditions. Modification of simulator data is accomplished by combining experiment with theory. The technique is demonstrated by application to a spectrally selective and a nonselective type of collector. This kind of modified simulator collector performance data should be valuable in solar systems analyses and for collector performance ranking based on all-day calculated conditions.

Simon, F. F.↗

Silicon crystal as a low work function collector

A test vehicle with a low work function collector which can be incorporated in a thermionic converter was constructed from standard vacuum components including an ultrahigh vacuum ion pump. The collector assembly was fabricated by diffusion bonding a (100) oriented silicon single crystal to a molybdenum block. The silicon surface was treated with cesium and oxygen to produce an NEA-type condition and the results were tested by photoemission and work function measurements. An n-type silicon collector was successfully activated to a work function of 1.0 eV, which was verified by photoemission spectral yield measurements. The stability test of an activated surface at elevated temperatures was conducted in the range from room temperature to 619 K, which was slightly lower than the designed collector temperature of 700 K. The work function measurements clearly demonstrated that the behavior of cesium replenishment on the activated Si surface was similar in nature to that of a metallic surface; that is, the loss of cesium by thermal desorption could be compensated by maintaining an adequate vapor pressure of cesium.

Chang, K. H.↗

An analysis for designing solar concentrator-collector configurations

An analysis for predicting the heat flux distribution on collectors in the focal region of solar concentrators has been formulated. The analysis is rather general and can consider limb darkening effects, collector placement errors, concentrator optical errors, and concentrator pointing errors. By coupling finite differencing techniques and heating requirements to this analysis, it can also be used to design concentrators that give prescribed heating on the collector surface. Illustrative results are presented. It is concluded that the concentrator and collector should be designed as a unit and that concentrator configurations that are more desirable than the paraboloid and cylindrical parabola can be designed.

Mcdermit, J. H.↗

Experimental performance of a small size two stage depressed collector for a 4.8-9.6 GHz high performance TWT

Three simple small size two stage depressed collectors were designed and experimentally evaluated in conjunction with a 330 to 520 watt CW, 4.8 to 9.6 GHz traveling wave tube (TWT). Each of the three designs produced a minimum collector efficiency of 80.0 percent considering saturated TWT operation at the maximum of output frequency and at band edges. The highest minimum collector efficiency produced was 80.5 percent with a two stage depressed collector of 4.8 cm diameter by 7 cm high internal dimensions.

Ramins, P.↗

Design, fabrication, testing, and delivery of a solar energy collector system for residential heating and cooling

A low cost flat plate solar energy collector was designed for the heating and cooling of residential buildings. The system meets specified performance requirements, at the desired system operating levels, for a useful life of 15 to 20 years, at minimum cost and uses state-of-the-art materials and technology. The rationale for the design method was based on identifying possible material candidates for various collector components and then selecting the components which best meet the solar collector design requirements. The criteria used to eliminate certain materials were: performance and durability test results, cost analysis, and prior solar collector fabrication experience.

Holland, T. H.↗

Summer performance results obtained from simultaneously testing ten solar collectors outdoors

Ten solar collectors were simultaneously tested outdoors. Efficiency data were correlated using a method that separates solar variables (flux, incident angle) from the desired performance parameters (heat loss, absorbtance, transmittance) which are unique to a given collector design. Tests were conducted on both clear and moderately cloudy days. Correlating data in the above manner, a 2-glass, black paint collector exhibited a decrease in efficiency of 5 percentage points relative to the baseline data for an exposure time of 2 years, 4 months. Condensation on the collector glazing was thought to be a contributing factor in this efficiency change.

Miller, D. R.↗

Thermionic converter performance with oxide collectors

Thermionic converters using a variety of metal oxide collector surfaces have been fabricated and tested. Both work function and power output data are presented and evaluated. Oxides of barium, strontium, zinc, tungsten and titanium have been incorporated into a variable spacing converter. Tungsten oxide was found to give the highest converter performance and to furnish oxygen for the emitter at the same time. Oxygenated emitters operate at reduced cesium pressure with an increase in electrode spacing. Electron spectroscopy for chemical analysis (ESCA) performed on several tungsten oxide collectors showed cesium penetration of the oxide layer, possibly forming a cesium tungstate bronze. Titanium oxide showed high performance but did not furnish oxygen for the emitter; strontium oxide, in the form of a sprayed layer, appeared to dissociate in the presence of cesium. Sprayed coatings of barium and zinc oxides produced collector work functions of about 1.3 eV, but had excessive series resistance. Lanthanum hexaboride, in combination with oxygen introduced through a silver tube, and cesium produced a low work function collector and better than average performance.

Lieb, D.↗

Considerations in the development of a high performance per unit cost solar collector

A flat plate collector employing a mild steel, pressure-expanded absorber plate has been developed. It is capable of energy output levels commensurate with the requirements of driving an absorption refrigeration system while operating at efficiency levels in the 35-40% range. Selective absorber surfaces of black chrome over nickel and black copper over copper were analyzed and prototype collectors containing each type of absorber plating were fabricated and tested for performance. Criteria applied to the cost effectiveness analysis of the collector included both the energy output per unit area and the collector fabrication cost per unit area.

Sims, W. H.↗

A fixed tilt solar collector employing reversible vee-trough reflectors and vacuum tube receivers for solar heating and cooling systems

The usefulness of vee-trough concentrators in improving the efficiency and reducing the cost of collectors assembled from evacuated tube receivers was studied in the vee-trough/vacuum tube collector (VTVTC) project. The VTVTC was analyzed rigorously and various mathematical models were developed to calculate the optical performance of the vee-trough concentrator and the thermal performance of the evacuated tube receiver. A test bed was constructed to verify the mathematical analyses and compare reflectors made out of glass, Alzak and aluminized FEP Teflon. Tests were run at temperatures ranging from 95 to 180 C. Vee-trough collector efficiencies of 35 to 40% were observed at an operating temperature of about 175 C. Test results compared well with the calculated values. Predicted daily useful heat collection and efficiency values are presented for a year's duration of operation temperatures ranging from 65 to 230 C. Estimated collector costs and resulting thermal energy costs are presented. Analytical and experimental results are discussed along with a complete economic evaluation.

Selcuk, M. K.↗

Collation of quarterly reports on air flat plate collectors

The solar 2 air flat plate collectors are described. The development and fabrication of a prototype air flat plate collector subsystem containing 320 square feet of collector area are described. Three instrumented panels were completely assembled with glazing and insulation. Manufacture of the last seven prototype collectors was completed in October 1977.

Source record↗

Indoor test for thermal performance evaluation of the Solaron (air) solar collector

The test procedure used and the results obtained from an evaluation test program, conducted to obtain thermal performance data on a Solaron double glazed air solar collector under simulated conditions in a solar simulator are described. A time constant test and incident angle modifier test were also conducted to determine the transient effect and the incident angle effect on the collector. These results and the results of the collector load test are also discussed. The Solaron collector absorber plate is made of 24-gage steel, the coating is baked-on black paint, the cover consists of two sheets of 1/8-inch low-iron tempered glass, and the insulation is one thickness of 3 5/8-inch fiberglass batting.

Source record↗

Owens-Illinois liquid solar collector materials assessment

From the beginning, it was noted that the baseline drawings for the liquid solar collector exhibited a distinct weakness concerning materials specification where elastomers, plastics, and foam insulation materials were utilized. A relatively small effort by a competent design organization would alleviate this deficiency. Based on results obtained from boilout and stagnation tests on the solar simulator, it was concluded that proof testing of the collector tubes prior to use helps to predict their performance for limited service life. Fracture mechanics data are desirable for predicting extended service life and establishing a minimum proof pressure level requirement. The temperature capability of this collector system was increased as the design matured and the coating efficiency improved. This higher temperature demands the use of higher temperature materials at critical locations in the collector.

Nichols, R. L.↗

MSFC Assessment of Owens-Illinois SUNPAK Collector Problems

An in-depth assessment is presented of problems encountered with the Owens-Illinois SUNPAK collector installed in several ERDA solar system demonstration sites. Analysis and independent tests of the collector in the MSFC Solar Simulator where the system failure conditions were duplicated are included. The basic design of the SUNPAK collector was shown to be sound; however, material limitations dictate that near-term applications constraints be recognized by system designers. MSFC recommendations were presented to ERDA in March 1977. Subsequent retrofit activity by Owens-Illinois appears to have been effective in demonstrating the integrity of the SUNPAK collector.

Wiesenmaier, B. L.↗

Simple, economical solar collector

Hot air solar collector designed for economy and simplicity is assembled from only three parts: (1) molded urethane foam body, (2) flat sheet metal collector panel and (3) transparent cover. Large arrays may be assembled by inserting male fittings of each collector into female fitting of adjacent collector.

Anthony, K.↗

Performance after weathering of a liquid solar collector

Results from retesting of liquid solar collector described in "Performance evaluation of liquid collector" (M-FS-23931), after long term exposure to natural weathering indicate no detectable degradation in collector performance and no visable deterioration in appearance of collector. Supporting data and pretest/post test efficiency comparison are included.

Source record↗