At least 91 records · Page 5

Field Results from Three Campaigns to Validate the Performance of the Miniaturized Laser Heterodyne Radiometer (Mini‐LHR) for Measuring Carbon Dioxide and Methane in the Atmospheric Column

In a collaboration between NASA GSFC and GWU, a low-cost, surface instrument is being developed that can continuously monitor key carbon cycle gases in the atmospheric column: carbon dioxide (CO2) and methane (CH4). The instrument is based on a miniaturized, laser heterodyne radiometer (LHR) using near infrared (NIR) telecom lasers. Despite relatively weak absorption line strengths in this spectral region, spectrallyresolved atmospheric column absorptions for these two molecules fall in the range of 60-80% and thus sensitive and precise measurements of column concentrations are possible. In the last year, the instrument was deployed for field measurements at Park Falls, Wisconsin; Castle Airport near Atwater, California; and at the NOAA Mauna Loa Observatory in Hawaii. For each subsequent campaign, improvement in the figures of merit for the instrument has been observed. In the latest work the absorbance noise is approaching 0.002 optical density (OD) noise on a 1.8 OD signal. An overview of the measurement campaigns and the data retrieval algorithm for the calculation of column concentrations will be presented. For light transmission through the atmosphere, it is necessary to account for variation of pressure, temperature, composition, and refractive index through the atmosphere that are all functions of latitude, longitude, time of day, altitude, etc. For temperature, pressure, and humidity profiles with altitude we use the Modern-Era Retrospective Analysis for Research and Applications (MERRA) data. Spectral simulation is accomplished by integrating short-path segments along the trajectory using the SpecSyn spectral simulation suite developed at GW. Column concentrations are extracted by minimizing residuals between observed and modeled spectrum using the Nelder-Mead simplex algorithm. We will also present an assessment of uncertainty in the reported concentrations from assumptions made in the meteorological data, LHR instrument and tracker noise, and radio frequency bandwidth and describe additional future goals in instrument development and deployment target

meteorological data↗

Lidar Observations of Atmospheric CO2 Column During 2014 Summer Flight Campaigns

Advanced knowledge in atmospheric CO2 is critical in reducing large uncertainties in predictions of the Earth' future climate. Thus, Active Sensing of CO2 Emissions over Nights, Days, and Seasons (ASCENDS) from space was recommended by the U.S. National Research Council to NASA. As part of the preparation for the ASCENDS mission, NASA Langley Research Center (LaRC) and Exelis, Inc. have been collaborating in development and demonstration of the Intensity-Modulated Continuous-Wave (IM-CW) lidar approach for measuring atmospheric CO2 column from space. Airborne laser absorption lidars such as the Multi-Functional Fiber Laser Lidar (MFLL) and ASCENDS CarbonHawk Experiment Simulator (ACES) operating in the 1.57 micron CO2 absorption band have been developed and tested to obtain precise atmospheric CO2 column measurements using integrated path differential absorption technique and to evaluate the potential of the space ASCENDS mission. This presentation reports the results of our lidar atmospheric CO2 column measurements from 2014 summer flight campaign. Analysis shows that for the 27 Aug OCO-2 under flight over northern California forest regions, significant variations of CO2 column approximately 2 ppm) in the lower troposphere have been observed, which may be a challenge for space measurements owing to complicated topographic condition, heterogeneity of surface reflection and difference in vegetation evapotranspiration. Compared to the observed 2011 summer CO2 drawdown (about 8 ppm) over mid-west, 2014 summer drawdown in the same region measured was much weak (approximately 3 ppm). The observed drawdown difference could be the results of the changes in both meteorological states and the phases of growing seasons. Individual lidar CO2 column measurements of 0.1-s integration were within 1-2 ppm of the CO2 estimates obtained from on-board in-situ sensors. For weak surface reflection conditions such as ocean surfaces, the 1- s integrated signal-to-noise ratio (SNR) of lidar measurements at 11 km altitude reached 376, which was equivalent to a 10-s CO2 error 0.33 ppm. For the entire processed 2014 summer flight campaign data, the mean differences between lidar remote sensed and in-situ estimated CO2 values were about -0.013 ppm. These results indicate that current laser absorption lidar approach could meet space measurement requirements for CO2 science goals.

Lin, Bing↗

Parameters Impacting Columnated Granular Soil Pneumatic Seal Performance

The ability of a column of loose granular soil to form a pneumatic seal was investigated by varying the diameter of the soil column, the effective column height, and the level of compaction in the soil. The data generated by this test campaign is intended to inform the design of various volatiles-extracting regolith reactor systems by investigating the viability of sealing system inlets using the soil hopper and feed tube without the use of any mechanical valves. This ‘soil column seal’ concept could be applied regardless of reactor geometry or process. Initial data was collected in ambient lab conditions using both GRC-1 and OB-1a regolith simulants. This data is intended to serve as a baseline –no attempt has been made yet to begin optimizing column parameters to achieve highest possible ∆𝑃.

Jack Stewart↗

Comparison Between Ozone Column Depths and Methane Lifetimes Computed By One- and Three-Dimensional Models at Different Atmospheric O(2) Levels

The calculation of ozone column depth as a function of atmospheric O2concentration has been performed multiple times over the past 40 years using one-dimensional (1-D) photochemical models. Several of these calculations [1–3] have been done by the Kasting group. We refer to the current version of that model as the‘standard’1-D model (see §2). Recently, Cooke et al., henceforth C22 ,performed a similar calculation using a three-dimensional (3-D) coupled chemistry-climate model (WACCM6). They found substantially lower ozone column depths at lower pO2levels. For example, at0.01 times the present atmospheric level (PAL) of O(2), Segura et al. calculated 124 Dobson units(DU), whereas C22 calculated a mean column depth of just 66 DU—almost a factor of two lower. This comparison is shown in figure 1. C22 argued, correctly, that 3-D models should be able to do a better job on this problem than 1-D models because ozone column depths are affected by atmospheric transport, e.g. the Brewer–Dobson circulation in the stratosphere that blows ozone from the tropics towards the poles, as well as vertical transport that carries ozone downward from the stratosphere to the troposphere. Meridional transport is absent in 1-D models, and vertical transport is fixed, so model geometry almost certainly contributes to the observed discrepancies in ozone column depth. The 3-D model also has a variable tropopause height (higher at the equator, lower towards the poles), which is difficult to simulate in one dimension.

Atmospheric chemistry↗

The influence of random packed column parameters on the liquid holdup and interfacial area

Abstract Carbon dioxide capture via solvent absorption in packed columns has emerged as a potential technology to mitigate coal‐fired power plant CO 2 emissions. Parameters, including packing types, solvent properties, and operating conditions, could potentially affect the packed column CO 2 capture efficiency. To understand the importance of those parameters and help packed column optimization, a design of experiments (DoEs) method was proposed to generate input parameter matrix. Combined with multiphase computational fluid dynamics (CFD), the random packed column parameter influence on the liquid holdup and interfacial area can be efficiently investigated. Surrogate‐based sensitivity analysis shows that the solvent flow rate and contact angle are key factors dictating liquid holdup and interfacial area. On the other hand, solvent viscosity has a marginal impact on the interfacial area. The sensitivity scores were calculated for each input parameter to guide the selection of dimensionless numbers for the liquid holdup and interfacial area correlation development.

42 ENGINEERING↗

Minimum reflux calculation for multicomponent distillation in multi‐feed, multi‐product columns: Mathematical model

Abstract Multi‐feed, multi‐product distillation columns are ubiquitous in multicomponent distillation systems. The minimum reflux ratio of a distillation column is directly related to its energy consumption and capital cost. Thus, it is a key parameter for distillation systems design, operation, and comparison. In this series, we present the first accurate shortcut based algorithmic method to determine the minimum reflux condition for any general multi‐feed, multi‐product (MFMP) distillation column separating any ideal multicomponent mixture. The classic McCabe‐Thiele or Underwood method is a special case of this general approach. Compared with existing techniques, this method does not involve any rigorous tray‐by‐tray calculation, nor does it require guessing of key components. In this first part of the series, we present the mathematical model for a general MFMP column, derive constraints for feasible separation and minimum reflux condition, discuss their geometric interpretations, and present an illustrative example to demonstrate the effectiveness of our approach.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Magnetic Sorbent for the Removal of Selenium(IV) from Simulated Industrial Wastewaters: Determination of Column Kinetic Parameters

A novel meso- and microporous tire-derived-carbon support with magnetic iron oxide nanoparticle adsorbents that selectively adsorbs Se(IV) ions from simulated contaminated water has been developed. In this work, the physicochemical characteristics of the composite adsorbent are characterized with respect to porosity and surface area, chemical composition, and microstructure morphology. The kinetics of this composite adsorbent in a fixed-bed setting has been determined. Several column runs were conducted and analyzed by inductively coupled plasma-optical emission spectroscopy (ICP-OES) to determine the concentration gradient vs time. These results were then fit to a pseudo-second order rate law to obtain equilibrium values. Combining calculated equilibrium values with effluent concentration data, enabled the application of the Adams–Bohart model to determine reaction constants and column coefficients. Column parameters obtained from different flow rates and fittings of the Adams–Bohart model were remarkably consistent. These findings enable the application of this sorbent to fixed-bed column systems and opens up further research into mixed pollutants tests with real wastewater and scaling of selenium pollutant removal.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Evaluation of engineered sorbents for the sorption of mercury from contaminated bank soils: a column study

Abstract As a global environmental pollutant, mercury (Hg) threatens our water resources and presents a substantial risk to human health. The rate and extent of immobilization of Hg 2+ (hereafter, Hg) on engineered sorbents (Thiol-SAMMS®, pine biochar, SediMite™, Organoclay™ PM-199, and quartz sand as a control) was evaluated using flow-through column experiments. The effectiveness of the sorbents was based on (1) the percentage of Hg removed in relation to the total amount of Hg passing the sorbent column, and (2) the rate of Hg uptake compared to the nonreactive tracer bromide (Br − ). All sorbents removed Hg to a certain extent, but none of the sorbents removed all the Hg introduced to the columns. Thiol-SAMMS showed the highest mean percentage of Hg removed (87% ± 2.9%), followed by Organoclay PM-199 (71% ± 0.4%), pine biochar (57% ± 22.3%), SediMite (61% ± 0.8%), and the control quartz sand (11% ± 5.6%). Thiol-SAMMS was the only sorbent to exhibit retardation of Hg in comparison to the conservative tracer Br − . For the remaining sorbents, Br − along with low concentrations of Hg were eluted within the first 3 pore volumes, indicating limited retardation of Hg. Overall, removal of Hg by sorbents was substantial, suggesting that sorbents might be suitable for deployment in contaminated environments. High concentrations of DOM leaching from the soil columns likely influenced the speciation of Hg and inhibited sorption to the sorbents. Incomplete removal of Hg by any sorbent suggests that additional optimization is needed to increase efficiency.

54 ENVIRONMENTAL SCIENCES↗

Selective recovery of rare earth elements with ligand-functionalized polymers in fixed-bed adsorption columns

Rare earth elements (REE) are a group of valuable metals with growing demand and broad applications. Mineral ores, the traditional sources of REE, require significant capital investment and their refinement has been a source of environmental contamination. Industrial fluids and natural REE-bearing liquids are potential alternative sources for these metals. This work investigated the performance and REE selectivity of polymer resin beads functionalized with N,N-bis(phosponomethyl)glycine (BPG) for extraction of REE from saline solutions in fixed-bed adsorption columns. Competitive batch adsorption experiments were conducted with various metals (Nd, Gd, Ho, Al, Fe, Co, Ni, Ba, Pb, Th, and U) and the BPG-functionalized resins were up to 137 times more selective for REE than aminated resins. In column experiments, the BPG-functionalized resins preferentially adsorbed heavier metals and REE were strongly retained in the functionalized column, taking 270 times longer than the amine column to reach 10% breakthrough and 128 times longer to reach 50% breakthrough. REE bound to the BPG-functionalized resins were recovered with a dilute HNO3 solution, yielding REE concentrations up to 236 times higher than the influent feedstock. This work provides new insight into the operational performance of novel functionalized adsorbents for recovery of REE from saline fluids.

42 ENGINEERING↗

Implementation and Exploration of Parameterizations of Large-Scale Dynamics in NCAR's Single Column Atmosphere Model SCAM6

A single column model with parameterized large-scale (LS) dynamics is used to better understand the response of steady-state tropical precipitation to relative sea surface temperature under various representations of radiation, convection, and circulation. The large-scale dynamics are parametrized via the weak temperature gradient (WTG), damped gravity wave (DGW), and spectral weak temperature gradient (Spectral WTG) method in NCAR's Single Column Atmosphere Model (SCAM6). Radiative cooling is either specified or interactive, and the convective parameterization is run using two different values of a parameter that controls the degree of convective inhibition. Results are interpreted in the context of the Global Atmospheric System Studies -Weak Temperature Gradient (GASS-WTG) Intercomparison project. Using the same parameter settings and simulation configuration as in the GASS-WTG Intercomparison project, SCAM6 under the WTG and DGW methods produces erratic results, suggestive of numerical instability. However, when key parameters are changed to weaken the large-scale circulation's damping of tropospheric temperature variations, SCAM6 performs comparably to single column models in the GASS-WTG Intercomparison project. The Spectral WTG method is less sensitive to changes in convection and radiation than are the other two methods, performing qualitatively similarly across all configurations considered. Under all three methods, circulation strength, represented in 1D by grid-scale vertical velocity, is decreased when barriers to convection are reduced. This effect is most extreme under specified radiative cooling, and is shown to come from increased static stability in the column's reference radiative-convective equilibrium profile. This argument can be extended to interactive radiation cases as well, though perhaps less conclusively.

54 ENVIRONMENTAL SCIENCES↗

Formaldehyde Column Density Measurements as a Suitable Pathway to Estimate Near-Surface Ozone Tendencies from Space

In support of future satellite missions that aim to address the current shortcomings in measuring air quality from space, NASA's Deriving Information on Surface Conditions from Column and Vertically Resolved Observations Relevant to Air Quality (DISCOVER-AQ) field campaign was designed to enable exploration of relationships between column measurements of trace species relevant to air quality at high spatial and temporal resolution. In the DISCOVER-AQ data set, a modest correlation (r2 = 0.45) between ozone (O3) and formaldehyde (CH2O) column densities was observed. Further analysis revealed regional variability in the O3-CH2O relationship, with Maryland having a strong relationship when data were viewed temporally and Houston having a strong relationship when data were viewed spatially. These differences in regional behavior are attributed to differences in volatile organic compound (VOC) emissions. In Maryland, biogenic VOCs were responsible for approx.28% of CH2O formation within the boundary layer column, causing CH2O to, in general, increase monotonically throughout the day. In Houston, persistent anthropogenic emissions dominated the local hydrocarbon environment, and no discernable diurnal trend in CH2O was observed. Box model simulations suggested that ambient CH2O mixing ratios have a weak diurnal trend (+/-20% throughout the day) due to photochemical effects, and that larger diurnal trends are associated with changes in hydrocarbon precursors. Finally, mathematical relationships were developed from first principles and were able to replicate the different behaviors seen in Maryland and Houston. While studies would be necessary to validate these results and determine the regional applicability of the O3-CH2O relationship, the results presented here provide compelling insight into the ability of future satellite missions to aid in monitoring near-surface air quality.

Surface Conditions from Column and Vertically Reso↗

Automated Machine Learning to Evaluate the Information Content of Tropospheric Trace Gas Columns for Fine Particle Estimates Over India: A Modeling Testbed

India is largely devoid of high-quality and reliable on-the-ground measurements of fine particulate matter (PM 2.5 ). Ground-level PM 2.5 concentrations are estimated from publicly available satellite Aerosol Optical Depth (AOD) products combined with other information. Prior research has largely overlooked the possibility of gaining additional accuracy and insights into the sources of PM using satellite retrievals of tropospheric trace gas columns. We evaluate the information content of tropospheric trace gas columns for PM 2.5 estimates over India within a modeling testbed using an Automated Machine Learning (AutoML) approach, which selects from a menu of different machine learning tools based on the data set. We then quantify the relative information content of tropospheric trace gas columns, AOD, meteorological fields, and emissions for estimating PM 2.5 over four Indian sub-regions on daily and monthly time scales. Our findings suggest that, regardless of the specific machine learning model assumptions, incorporating trace gas modeled columns improves PM 2.5 estimates. We use the ranking scores produced from the AutoML algorithm and Spearman’s rank correlation to infer or link the possible relative importance of primary versus secondary sources of PM 2.5 as a first step toward estimating particle composition. Our comparison of AutoML-derived models to selected baseline machine learning models demonstrates that AutoML is at least as good as user-chosen models. The idealized pseudo-observations (chemical-transport model simulations) used in this work lay the groundwork for applying satellite retrievals of tropospheric trace gases to estimate fine particle concentrations in India and serve to illustrate the promise of AutoML applications in atmospheric and environmental research.

Machine learning↗

Influence of design and operating parameters for additively manufactured intensified packing devices on CO 2 -Absorption column cooling and capture efficiency

Solvent-based CO 2 absorption is technologically a matured CO 2 capture pathway but suffers from: high regeneration energy demand, and solvent temperature rise and decreased capture efficiency caused by the heat of reaction. While research has focused on developing non-aqueous and low-aqueous solvents for decreasing the regeneration energy, the temperature bulge due to exothermic absorption is typically dealt with by cooling the solvent with an external inter-stage heat-exchanger. This approach may increase the overall process footprint, as well as capital and operating costs. Here, the current study explores a process intensification approach by incorporating inside the column an additively manufactured intensified packing device that consists of corrugated plates and internal coolant channels. The corrugated plates provide surface area for mass transfer between gas and liquid, while cooling fluid inside the internal channels removes heat from the exothermic reactive system. Two different intensified devices with specific surface areas of 266 m 2 /m 3 and 359 m 2 /m 3 were designed, manufactured, and tested inside a 2.06-m long and 0.203-m diameter column packed with commercial Mellapak 250Y packing. The device with a lower surface area showed up to 27 % reduction in cooling performance. A steady-state heat transfer model provides good agreement with the experimental column temperature and intra-stage heat removal data. Although a decrease in heat transfer performance was observed for the device with lower surface area, CO 2 capture experiments performed with simulated flue gas and low-aqueous solvent demonstrated that both intensified devices lead to a similar improvement of 12 % in capture efficiency. This study provides an understanding on simplifying the intensified packing device geometry and decreasing the device fabrication cost by 25 % without compromising with the CO 2 absorption performance of the packed column.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Multiple biomarkers highlight the importance of water column processes in treatment wetland organic matter cycling

A suite of biomarkers, including amino acids, pigments, and lignin phenols coupled with high resolution mass spectrometry were used to evaluate differences in the sources and fate of organic matter (OM) in Everglades treatment wetlands as a model for OM cycling in shallow water wetlands. Five components of the system (water column particulate organic matter, vertical traps, flocculent material, periphyton, and surface soil) were assessed for OM transformations down-profile (i.e. water column to soil) and between treatment cells dominated by emergent aquatic vegetation (EAV) and submerged aquatic vegetation (SAV), with comparisons to reference sites that resemble historic Everglades conditions. We found that OM cycling is fundamentally different between EAV and SAV wetlands, and that SAV wetlands have some shared characteristics with similar habitats in the Everglades. Other than locations densely populated by Typha spp., water column particulate organic C was derived from microbial/cryptomonad sources, rather than macroscopic sources (vascular plants and algal mats). Bacterial amino acid biomarkers were positively correlated with amino acid degradation indices and organic P (Po), respectively suggesting that microbial abundance is associated with "fresher" OM, and that further investigation into relationships between microbial biomass and Po is warranted. Overall, this multi-biomarker approach can evaluate the relative "freshness" of OM pools, identify sources of OM, and highlight the importance of water column processes in shallow water wetlands.

treatment wetlands, organic matter, Everglades, am↗

Label-Free Profiling of up to 200 Single-Cell Proteomes per Day Using a Dual-Column Nanoflow Liquid Chromatography Platform

Single-cell proteomics (SCP) has great potential to advance biomedical research and personalized medicine. The sensitivity of such measurements increases with low-flow separations (<100 nL/min) due to improved ionization efficiency, but the time required for sample loading, column washing, and regeneration in these systems can lead to low measurement throughput and inefficient utilization of the mass spectrometer. Herein, we developed a two-column liquid chromatography (LC) system that dramatically increases the throughput of label-free SCP using two parallel subsystems to multiplex sample loading, online desalting, analysis, and column regeneration. The integration of MS1-based feature matching increased proteome coverage when short LC gradients were used. The high-throughput LC system was reproducible between the columns, with a 4% difference in median peptide abundance and a median CV of 18% across 100 replicate analyses of a single-cell-sized peptide standard. An average of 621, 774, 952, and 1622 protein groups were identified with total analysis times of 7, 10, 15, and 30 min, corresponding to a measurement throughput of 206, 144, 96, and 48 samples per day, respectively. When applied to single HeLa cells, we identified nearly 1000 protein groups per cell using 30 min cycles and 660 protein groups per cell for 15 min cycles. Finally, we explored the possibility of measuring cancer therapeutic targets with a pilot study comparing the K562 and Jurkat leukemia cell lines. This work demonstrates the feasibility of high-throughput label-free single-cell proteomics.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Static and Dynamic Intensification of Water–Ethylene Glycol Separation Using a Dividing Wall Column

This paper makes several first-of-a-kind contributions toward “double intensification” (static/dynamic) of distillation systems, focusing in particular on the energy-intensive separation of a mixture of water and ethylene glycols. First, we demonstrate that a dividing wall column (DWC) can be an appropriate choice for separating wide-boiling zeotropic mixtures. Additionally, we show that the conventional DWC configuration where the wall is in the “middle” should be discarded in favor of a less frequently encountered “common-bottom” setup. For the mixture considered, choosing a DWC in lieu of a conventional two-column sequence can lead to over 6% energy cost savings and a 5% reduction in the number of stages compared to the conventional direct sequence two-column counterpart. The second part of this paper focuses on applying the previously introduced concept of dynamic process intensification to the DWC, the first time that such an effort is reported in the literature, to our knowledge. Here, we show that an additional 1.4% energy savings can be unlocked in this way, and confirm the stable operation of the column via dynamic simulation.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A single column separation method for barium isotope analysis of geologic and hydrologic materials with complex matrices

Abstract The increasing significance of barium (Ba) in environmental and geologic research in recent years has led to interest in the application of the Ba isotopic composition as a tracer for natural materials with complex matrices. Most Ba isotope measurement techniques require separation of Ba from the rest of sample prior to analysis. This paper presents a method using readily available materials and disposable columns that effectively separates Ba from a range of geologic and hydrologic materials, including carbonate minerals, silicate rocks, barite, river water, and fluids with high total dissolved solids and organic content such as oil and gas brines, rapidly and without need for an additional cleanup column. The technique involves off-the-shelf columns and cation exchange resin and a two-reagent elution that uses 2.5 N HCl followed by addition of 2.0 N HNO 3 . We present data to show that major matrix elements from almost any natural material are separated from Ba in a single column pass, and that the method also effectively reduces or eliminates isobaric interferences from lanthanum and cerium.

Matecha, R. M.↗

Tank Closure Cesium Removal Ion Exchange Column CST Characterization: SRNL-STI-2024-00072 (Rev.0) pdf

Savannah River Mission Completion (SRMC) recently suspended operation of the Tank Closure Cesium Removal (TCCR) system which utilized an ion exchange (IX) process to remove radioactive cesium from waste supernate. During the demonstration phase, a total of three batches of Tank 10H dissolved salt waste were processed through the original TCCR columns. Subsequently, dissolved salt waste from Tank 9H was processed through TCCR in a phase referred to as TCCR 1A with four new IX columns. All eight columns have now been moved to Interim Safe Storage (ISS). For each batch processed through the TCCR IX columns, SRNL performed a number of analyses on surface and variable depth samples as well as batch equilibrium contact tests (BECT) to determine equilibrium loadings of Cs on the crystalline silicotitanate (CST) IX media. The BECTs were performed by lowering “teabags” containing ~0.1 g of CST each into the tank for a period of at least 10 days. The teabags were then retrieved and sent to SRNL for digestion and analysis.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗