Search NASA⌕ Search

SEARCH · Search NASA

Results for “COMPACT COMMISSIONS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

CUORE: The first bolometric experiment at the ton scale for rare decay searches

Here, the Cryogenic Underground Observatory for Rare Events (CUORE) is the first bolometric experiment searching for neutrinoless double beta decay that has been able to reach the 1-ton scale. The detector consists of an array of 988 TeO 2 crystals arranged in a cylindrical compact structure of 19 towers. The construction of the experiment and, in particular, the installation of all towers in the cryostat was completed in August 2016 and data taking started in spring 2017. In this contribution the achievement of the commissioning phase and the performance of the detector and the cryostat during the first physics run will be presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

An all permanent magnet electron cyclotron resonance ion source for heavy ion therapy

A high charge state all permanent Electron Cyclotron Resonance ion source, Lanzhou All Permanent ECR ion source no. 3-LAPECR3, has been successfully built at IMP in 2012, which will serve as the ion injector of the Heavy Ion Medical Machine (HIMM) project. As a commercial device, LAPECR3 features a compact structure, small size, and low cost. According to HIMM scenario more than 100 eμA of C{sup 5+} ion beam should be extracted from the ion source, and the beam emittance better than 75 π*mm*mrad. In recent commissioning, about 120 eμA of C{sup 5+} ion beam was got when work gas was CH{sub 4} while about 262 eμA of C{sup 5+} ion beam was obtained when work gas was C{sub 2}H{sub 2} gas. The design and construction of the ion source and its low-energy transportation beam line, and the preliminary commissioning results will be presented in detail in this paper.

43 PARTICLE ACCELERATORS↗

Experimental setups for FEL-based four-wave mixing experiments at FERMI

The recent advent of free-electron laser (FEL) sources is driving the scientific community to extend table-top laser research to shorter wavelengths adding elemental selectivity and chemical state specificity. Both a compact setup (mini-TIMER) and a separate instrument (EIS-TIMER) dedicated to four-wave-mixing (FWM) experiments has been designed and constructed, to be operated as a branch of the Elastic and Inelastic Scattering beamline: EIS. The FWM experiments that are planned at EIS-TIMER are based on the transient grating approach, where two crossed FEL pulses create a controlled modulation of the sample excitations while a third time-delayed pulse is used to monitor the dynamics of the excited state. This manuscript describes such experimental facilities, showing the preliminary results of the commissioning of the EIS-TIMER beamline, and discusses original experimental strategies being developed to study the dynamics of matter at the fs–nm time–length scales. In the near future such experimental tools will allow more sophisticated FEL-based FWM applications, that also include the use of multiple and multi-color FEL pulses.

Bencivenga, Filippo↗

AMiBA: cluster Sunyaev-Zel'dovich effect observations with the expanded 13-element array

The Yuan-Tseh Lee Array for Microwave Background Anisotropy (AMiBA) is a co-planar interferometer array operating at a wavelength of 3 mm to measure the Sunyaev–Zel’dovich effect (SZE) of galaxy clusters at arcminute scales. The first phase of operation—with a compact 7-element array with 0.6 m antennas (AMiBA-7)—observed six clusters at angular scales from 5{sup ′} to 23{sup ′}. Here, we describe the expansion of AMiBA to a 13-element array with 1.2 m antennas (AMiBA-13), its subsequent commissioning, and cluster SZE observing program. The most noticeable changes compared to AMiBA-7 are (1) array re-configuration with baselines ranging from 1.4 m to 4.8 m, allowing us to sample structures between 2{sup ′} and 10{sup ′}, (2) 13 new lightweight carbon-fiber-reinforced plastic (CFRP) 1.2 m reflectors, and (3) additional correlators and six new receivers. Since the reflectors are co-mounted on and distributed over the entire six-meter CFRP platform, a refined hexapod pointing error model and phase error correction scheme have been developed for AMiBA-13. These effects—entirely negligible for the earlier central close-packed AMiBA-7 configuration—can lead to additional geometrical delays during observations. Our correction scheme recovers at least 80 ± 5% of the point-source fluxes. We, therefore, apply an upward correcting factor of 1.25 to our visibilities to correct for phase decoherence, and a ±5% systematic uncertainty is added in quadrature with our statistical errors. We demonstrate the absence of further systematics with a noise level consistent with zero in stacked uv-visibilities. From the AMiBA-13 SZE observing program, we present here maps of a subset of 12 clusters with signal-to-noise ratios above five. We demonstrate combining AMiBA-7 with AMiBA-13 observations on Abell 1689, by jointly fitting their data to a generalized Navarro–Frenk–White model. Our cylindrically integrated Compton-y values for five radii are consistent with results from the Berkeley-Illinois-Maryland Array, the Owens Valley Radio Observatory, the Sunyaev–Zel’dovich Array, and the Planck Observatory. We also report the first targeted SZE detection toward the optically selected cluster RCS J1447+0828, and we demonstrate the ability of AMiBA SZE data to serve as a proxy for the total cluster mass. Finally, we show that our AMiBA-SZE derived cluster masses are consistent with recent lensing mass measurements in the literature.

79 ASTRONOMY AND ASTROPHYSICS↗

Migration to a fully-integrated control room - 349

The nuclear industry is faced with a pressing need to reduce operating costs in order to remain competitive with other forms of electric generation. While current industry initiatives are focused on incremental gains by streamlining work processes and reducing worker burdens, very few, if any, involve significant reductions in the base workload of a nuclear plant. Migration to a fully-integrated control room affords just such an opportunity. This report describes an NPP digital instrumentation and control (I and C) system design, along with its corresponding human systems interface (HSI) design, which achieves high plant availability, while selectively applying digital equipment redundancy and integrating traditional I and C system partitions, to minimize the digital equipment needed, and thereby minimize initial installation costs and ongoing operations and maintenance (O and M) costs. An additional key component of digital equipment minimization is optimization of the digital interface to conventional plant sensors and controlled plant devices (e.g., pumps, valves), which requires no disturbance to plant cables and results in eliminating thousands of electro-mechanical relay control components. The design is rooted in the highly integrated digital technology applied to the most recent advanced light water reactors under United States (U.S.) Nuclear Regulatory Commission (NRC) design certification review and approval. While this design employs technology from new plants, that technology has been adapted to the modernization of current operating NPPs. Hence, the highly integrated digital I and C and HSI design is referred to as the compact control room digital modernization (CDM). Along with minimal digital equipment, the corresponding HSI design employs compact operator workstations with visual display units (VDU) and soft controls for both the main control room (MCR) and remote shutdown room (RSR), to immediately improve human performance and ultimately facilitate operating staff reduction. Some advanced light water reactors have demonstrated this staff reduction through full scope simulator testing of normal and abnormal plant conditions, with U.S. licensed operating crews from currently-operating U.S. plants. Digital equipment minimization, compact operator workstations, and optimized plant component interfaces that require no disturbance to field cables, also facilitate implementation of the CDM over multiple phases, most of which can be conducted during normal refueling shutdown windows. This phased implementation method includes a novel transition of the I and C, MCR and RSR with an operations centered focus. This paper presents the CDM design, along with qualitative cost/benefit comparisons to currently operating plants with conventional analog I and C and HSI technology; this generation of I and C/HSI is referred to as a conventional control room (CCR). A CCR also includes NPPs that have been upgraded with digital systems, but retain the current partitions between plant I and C systems (i.e., no I and C integration) and retain the current plant system to control board configuration of current NPP control rooms. Even though these comparisons are qualitative, a compelling case is presented for the CDM. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Commissioning of the Delta Polarizing Undulator at LCLS

The Linac Coherent Light Source (LCLS) generates linearly polarized, intense, high-brightness x-ray pulses from planar fixed-gap undulators. While the fixed-gap design supports a very successful and tightly controlled alignment concept, it provides only limited taper capability (up to 1% through canted pole and horizontal position adjustability) and lacks polarization control. The latter is of great importance for soft x-ray experiments. A new 3.2-m-long compact undulator (based on the Cornell University Delta design) has been developed and installed in place of the last LCLS undulator segment (U33) in October 2014. This undulator provides full control of the polarization degree and K value. Used on its own, it produces fully polarized radiation in the selected state (linear, circular or elliptical) but at low intensity. To increase the output power by orders of magnitude, the electron beam is micro-bunched by several (~10) of the upstream LCLS undulator segments operated in the linear FEL regime. As unavoidable by-product, this microbunching process produces moderate amounts of horizontally linear polarized radiation which mixes with the radiation produced by the Delta undulator. This unwanted radiation component has been greatly reduced by the reverse taper configuration, as suggested by E. Schneidmiller and M. Yurkov. Full elimination of the linear polarized component was achieved through spatial separation combined with transverse collimation. The paper describes these and other methods tested during commissioning. It also presents results of polarization measurements showing high degrees of circular polarization in the soft x-ray wavelength range (500 eV - 1500 eV).

43 PARTICLE ACCELERATORS↗

Preliminary Reporting of Thermophysical Property Measurements for the Ghareb Formation

Accurate knowledge of thermophysical properties of rock is vital to develop meaningful models of high level nuclear waste emplacement scenarios. The Israel Atomic Energy Commission is considering storing high level nuclear waste in the Ghareb formation, a porous kerogen bearing chalk. Sandia is supporting this effort with an evolving lab- based geomechanics testing program. We have completed measurements of thermal properties up to 275C and room temperature hydrostatic compaction measurements. We report thermal conductivity, thermal diffusivity, specific heat, and mass loss from our thermal measurements, and we report bulk moduli and porosity loss from our compaction measurements. These values are crucial for the numerical models to simulate heat transfer and formation compressibility around a heat generating repository.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Beamline for E-beam processing at UITF

Electron beam irradiation is a method that has shown a good potential to reduce several pollutants in wastewater. One of the main challenges towards wider adoption of this method is the need for compact, reliable, cost-effective, high-power accelerators. Jefferson Lab is working on the design and prototyping of accelerator components, based on superconducting radio-frequency (SRF) technology, aiming at accelerators for industrial applications. The LDRD project aimed at designing, procuring, installing, and commissioning a beamline at the Upgraded Injector Test Facility (UITF) accelerator to allow electron-beam irradiation studies of different materials, beginning with wastewater. The availability of such beamline allows exploring the ability of electron-beam radiation to reduce or eliminate so-called “forever chemicals” that can be found in wastewater or industrial sites. After successful commissioning, the beamline was used to irradiate wastewater samples with different concentrations of 1,4-dioxane, in collaboration with Hampton Roads Sanitation District (HRSD).

42 ENGINEERING↗

The upgrade and re-validation of the Compact Muon Solenoid Electromagnetic Calorimeter Control and Safety Systems during the Second Long Shutdown of the Large Hadron Collider at CERN

The Electromagnetic Calorimeter (ECAL) is one of the subdetectors of the Compact Muon Solenoid (CMS), a general-purpose particle detector at the CERN Large Hadron Collider (LHC). The CMS ECAL Detector Control System (DCS) and the CMS ECAL Safety System (ESS) have supported the detector operations and ensured the detector’s integrity since the CMS commissioning phase, more than 10 years ago. Over this long period, several changes to both systems were necessary to correct issues, extend functionality and keep them in-line with current hardware technologies and the evolution of software platforms. Due to the constraints imposed on significant changes to a running system, major hardware and software upgrades were therefore deferred to the second LHC Long Shutdown (LS2). This paper presents the architectures of the CMS ECAL control and safety systems, discusses the ongoing and planned upgrades, details implementation processes and validation methods and highlights the expectations for the post-LS2 systems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Compton transmission polarimeter for DC and SRF electron photo-injectors

The production of high-current and intense spin polarized electron beams is of great importance in electron-based facilities. Tests are planned to produce such beams in 2023 using GaAs-based photocathodes installed in the Brookhaven National Lab RHIC Coherent electron Cooling superconducting radiofrequency (SRF) photogun [1]. A fast and efficient electron polarimeter operating in the MeV energy range is required to measure the beam spin polarization. While Mott polarimeters provide larger measured asymmetries, a Compton Transmission polarimeter is well suited in the few MeV energy range. In this work, we report on a relatively compact and cost-effective Compton transmission polarimeter which has been built and calibrated at Jefferson Lab (JLab). First, we present the design of the polarimeter radiator, polarized target analyzing magnet, BGO detector assembly and data acquisition system. Next, results of a two-week commissioning study performed at the JLab Upgraded Injector Test Facility will be described. Here, a well-known polarized electron beam produced from a bulk GaAs photocathode in a dc high-voltage photogun was first measured in a 180 keV Mott scattering polarimeter, then used to characterize and calibrate the Compton transmission polarimeter as a function of the polarized target magnetization and beam properties. Finally, we report an effective analyzing power of the Compton polarimeter and compare experimental results with those produced via Geant4 simulations.

Blume, G.↗

A Compton transmission polarimeter for DC and SRF electron photo-injectors

The production of high-current and intense spin polarized electron beams is of great importance in electron-based facilities. Tests are planned to produce such beams in 2023 using GaAs-based photocathodes installed in the Brookhaven National Lab RHIC Coherent electron Cooling superconducting radiofrequency (SRF) photogun [1]. A fast and efficient electron polarimeter operating in the MeV energy range is required to measure the beam spin polarization. While Mott polarimeters provide larger measured asymmetries, a Compton Transmission polarimeter is well suited in the few MeV energy range. In this work, we report on a relatively compact and cost-effective Compton transmission polarimeter which has been built and calibrated at Jefferson Lab (JLab). First, we present the design of the polarimeter radiator, polarized target analyzing magnet, BGO detector assembly and data acquisition system. Next, results of a two-week commissioning study performed at the JLab Upgraded Injector Test Facility will be described. Here, a well-known polarized electron beam produced from a bulk GaAs photocathode in a dc high-voltage photogun was first measured in a 180 keV Mott scattering polarimeter, then used to characterize and calibrate the Compton transmission polarimeter as a function of the polarized target magnetization and beam properties. Finally, we report an effective analyzing power of the Compton polarimeter and compare experimental results with those produced via Geant4 simulations.

Blume, G.↗

First hydrogen operation of NIO1: Characterization of the source plasma by means of an optical emission spectroscopy diagnostic

NIO1 (Negative Ion Optimization 1) is a compact and flexible radio frequency H{sup −} ion source, developed by Consorzio RFX and INFN-LNL. The aim of the experimentation on NIO1 is the optimization of both the production of negative ions and their extraction and beam optics. In the initial phase of its commissioning, NIO1 was operated with nitrogen, but now the source is regularly operated also with hydrogen. To evaluate the source performances, an optical emission spectroscopy diagnostic was installed. The system includes a low resolution spectrometer in the spectral range of 300-850 nm and a high resolution (50 pm) one, to study, respectively, the atomic and the molecular emissions in the visible range. The spectroscopic data have been interpreted also by means of a collisional-radiative model developed at IPP Garching. Besides the diagnostic hardware and the data analysis methods, the paper presents the first plasma measurements across a transition to the full H mode, in a hydrogen discharge. The characteristic signatures of this transition in the plasma parameters are described, in particular, the sudden increase of the light emitted from the plasma above a certain power threshold.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characteristics of Fuel Articles for Irradiation Testing in INL-TREAT and MIT-NRL

To obtain valuable data that will help in the design and commissioning of the Transformational Challenge Reactor, a series of graded, increasingly complex irradiation tests are planned that will demonstrate the feasibility of advanced manufactured reactor core components. In the first irradiation test, conventionally- fabricated uranium nitride tristructural isotropic (UN TRISO) fuel kernels will be embedded into compacts that are fabricated using advanced manufacturing methods. These compacts are to be irradiated at Massachusetts Institute of Technology’s Nuclear Reactor Laboratory and Idaho National Laboratory’s Transient Reactor Test Facility. This report presents the characteristics of the proposed samples and experiments.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Compact, portable, automatic sample changer stick for cryostats and closed-cycle refrigerators

Beamlines are facilities that produce and deliver highly focused and intense beams of radiation, typically x rays, synchrotron radiation, or neutrons, for scientific research purposes. Millions of dollars are spent annually to maintain and operate these scientific beamlines, oftentimes running continuously between cycles. To reduce human intervention and improve productivity, mechanical sample changers are often commissioned for use. Designing sample changers is difficult because mechanical parts can be bulky, expensive, and challenging to design for instruments with low volume access, high radiation, and cryogenic environments. We present a portable and inexpensive sample changer stick that can hold and manipulate up to four samples, specifically designed for use with cryogenic closed-cycle refrigerators. The sample changer stick enables rapid and efficient exchange of samples without manual intervention, and is compatible with standard sample mounts such as vanadium cans. The sample changer stick includes a motorized rotation and lancing mechanism, which enables the precise positioning of each sample in the neutron beam, while ensuring compatibility with the operating temperatures and vacuum conditions required for closed-cycle refrigerators. The design has been successfully tested at the VISION beamline at the Spallation Neutron Source. The mechanical action and software controls are detailed. Furthermore, the sample changer stick is a valuable tool for scientists working with cryogenic closed-cycle refrigerators.

36 MATERIALS SCIENCE↗

Hofmann Stability Charts Revisited for PIP-II: From Classical Theory to Assumption-Free and ML-Driven Maps

The Hofmann stability chart remains a standard for visualizing parametric resonances in space-charge–dominated linacs, but its use typically relies on non-oscillatory Vlasov dispersion relations with simplifying assumptions (continuous focusing, KV phase space, linear optics, limited transverse–longitudinal coupling). We revisit the chart for the PIP-II linac along three tracks. (1) We reproduce the conventional maps in the (νz/νx, νx/ν0x) plane for relevant εz/εx, providing a validated reference. (2) We remove key assumptions by deriving stability surfaces directly from multi-particle tracking with realistic lattice discreteness, RF defocusing, solenoid/quad optics, and bunched-beam dynamics; local tunes and early-time growth rates are estimated from envelope oscillations and projected to the same coordinates. These assumption-reduced maps recover the canonical stopbands while revealing shifts and broadenings driven by tune modulation, non-KV distributions, and transverse–longitudinal coupling at PIP-II intensities. (3) We train a compact machine-learning surrogate that emulates the growth surface from zero-current optics, tune depression, emittance ratio, bunching factor, and selected lattice descriptors, enabling rapid scans and online working-point selection. We compare the three representations on representative PIP-II sections and discuss implications for commissioning guard bands, resonance avoidance, and routine operations.

Pathak, Abhishek [Fermilab] (ORCID:000000021704208↗

Environmental impacts of lighting technologies - Life cycle assessment and sensitivity analysis

With two regulations, 244/2009 and 245/2009, the European Commission recently put into practice the EuP Directive in the area of lighting devices, aiming to improve energy efficiency in the domestic lighting sector. This article presents a comprehensive life cycle assessment comparison of four different lighting technologies: the tungsten lamp, the halogen lamp, the conventional fluorescent lamp and the compact fluorescent lamp. Taking advantage of the most up-to-date life cycle inventory database available (ecoinvent data version 2.01), all life cycle phases were assessed and the sensitivity of the results for varying assumptions analysed: different qualities of compact fluorescent lamps (production phase), different electricity mixes (use phase), and end-of-life scenarios for WEEE recycling versus municipal solid waste incineration (disposal phase). A functional unit of 'one hour of lighting' was defined and the environmental burdens for the whole life cycle for all four lamp types were calculated, showing a clearly lower impact for the two gas-discharge lamps, i.e. the fluorescent and the compact fluorescent lamp. Differences in the product quality of the compact fluorescent lamps reveal to have only a very small effect on the overall environmental performance of this lamp type; a decline of the actual life time of this lamp type doesn't result in a change of the rank order of the results of the here examined four lamp types. It was also shown that the environmental break-even point of the gas-discharge lamps is reached long before the end of their expected life-span. All in all, it can be concluded that a change from today's tungsten lamp technology to a low-energy-consuming technology such as the compact fluorescent lamp results in a substantial environmental benefit.

54 ENVIRONMENTAL SCIENCES↗

Commissioning & Characterization of Magnetized Gridded Thermionic Electron Source

Collaborative efforts to design and fabricate a magnetized gridded thermionic electron source have been conducted between Xelera and Jefferson Lab. Commissioning and characterization of an electron gun fabricated by Xelera was performed to benchmark the viability of future electron source designs and capabilities. The work involved simulation, installation, trouble-shooting, modifications of the design, commissioning, characterization, and magnetization of the electron beam produced. A specially designed cavity as well as novel diagnostic tools and methods were developed, implemented, and experimentally tested. Finally, the gun was used to demonstrate a previously unachieved current of magnetized electron beam from a gridded thermionic source of this uniquely compact size. This thesis addresses the following scientific and technological challenges: building a compact gridded thermionic electron source, producing high current magnetized electron beam, and demonstrating novel characterization measurements for magnetized beam.

Stefani, Mark↗

Electron cyclotron resonance ion sources in use for heavy ion cancer therapy

The use of electron cyclotron resonance (ECR) ion sources for producing ion beams for heavy ion cancer therapy has been established for more than ten years. After the Heavy Ion Medical Accelerator (HIMAC) at Chiba, Japan started therapy of patients with carbon ions in 1994 the first carbon ion beam for patient treatment at the accelerator facility of GSI was delivered in 1997. ECR ion sources are the perfect tool for providing the required ion beams with good stability, high reliability, and easy maintenance after long operating periods. Various investigations were performed at GSI with different combinations of working gas and auxiliary gas to define the optimal beam conditions for an extended use of further ion species for the dedicated Heidelberg Ion Beam Therapy (HIT) facility installed at the Radiological University Hospital Heidelberg, Germany. Commercially available compact all permanent magnet ECR ion sources operated at 14.5 GHz were chosen for this facility. Besides for {sup 12}C{sup 4+} these ion sources are used to provide beams of {sup 1}H{sub 3}{sup 1+}, {sup 3}He{sup 1+}, and {sup 16}O{sup 6+}. The final commissioning at the HIT facility could be finished at the end of 2006.

43 PARTICLE ACCELERATORS↗