Search NASA⌕ Search

SEARCH · Search NASA

Results for “COMPRESSORS - RADIAL FLOW”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

A methodology to develop multi-physics dynamic fuel cell system models validated with vehicle realistic drive cycle data

Fuel cell (FC) technology has been identified as a technically attractive solution to decarbonize the transportation sector, especially for heavy-duty vehicles. In this context, the industry and the scientific community are in need of advanced fuel cell systems (FCS) models that are able to replicate real -world operating conditions. Due to the scarcity of said models in the open literature, this study aimed to develop a comprehensive methodology to calibrate and validate multi -physics dynamic FCS models. Therefore, the key contribution of this paper is the detailed description of the calibration process for each component and the calibration order. The specific focus here was to accurately describe the behavior of the FC stack as well as the cathode, anode, and cooling circuits of the balance of plant. The model was calibrated with the aid of experimental data from a Toyota Mirai FC electric vehicle, which was predominantly retrieved from the vehicle's Controller Area Network (CAN) bus system thereby negating the need for major intrusion into the powertrain system. The validation process was deemed successful with the model being able to truthfully replicate the characteristics of the FC vehicle operated on the World-wide harmonized Light duty Test Cycle (WLTC) 3b and US06 driving cycle. The time -resolved physical parameters such as the cathode pressure, mass flow, or the FC stack temperature were captured with high fidelity, while the overall performance parameters such as the H2 consumption in the stack and the system, and the compressor energy consumption were predicted accurately with a deviation lower than 0.47%, 1.75% and 1.89% with respect to the experimental data, respectively.

Lopez-Juarez, Marcos↗

Numerical Investigation of Two-Stage Vapor Compression System with Simultaneous Vapor and Liquid Injection

Two-stage vapor compression systems can be advantageous over single-stage systems by providing improved system performance, lower discharge temperature and reduced throttling losses. These systems employ various intermediate configurations, such as liquid injection and vapor injection. This paper presents a configuration for a R1234ze(E) two-stage air-conditioning system using a turbo compressor with two injection ports, one for vapor injection and the second for liquid injection. The liquid injection is used to cool the motor and electronics. A component-based representation and solution approach was used to simulate the two-stage compression system with simultaneous vapor and liquid injection at steady state. The turbo compressor was represented using a customized performance map. The condenser and the evaporator were modeled using finite-volume approach. A parametric study was conducted to assess the impact of the following three variables on the system performance: vapor injection ratio, condenser air flow rate, and discharge pipe pressure drop. The simulation results show that as the vapor injection ratio increased, the system performance undergoes a tradeoff between an enhanced subcooling effect (and thus enhanced unit refrigeration capacity) and a decreased suction mass flow rate. Maximum COP occurs when the vapor injection ratio was 0.1. The results also show that as the condenser air flow rate increased, both the capacity and power consumption (including fan power) increased monotonically, and COP increased first and then decreased. At 75% load, the COP improvement at the optimum flow rate was marginally less than 0.5%. Lastly, higher discharge pipe pressure drop increased the discharge pressure. It showed very small effect on the overall system performance at the condition selected for the current study.

component-based steady-state simulation↗

Control methods for mitigating flow oscillations in a supercritical CO 2 recompression closed Brayton cycle

A dynamic model of a 10 MWe supercritical CO 2 (sCO 2 ) recompression closed Brayton power generation cycle is used to investigate control methods for mitigating oscillations in flow conditions and power demand load, especially as the load ramp rate is increased and the load setpoint is more closely tracked. The focus is on control of the main compressor inlet temperature (MCIT) since oscillations are prompted by the strong nonlinearities in sCO 2 fluid properties near the critical point and by changes in system inventory for efficient load management. In this study, the oscillatory behavior during load ramping is first shown and then two potential control solutions for substantially reducing oscillations are given: 1) the use of the main compressor inlet guide vanes (IGV) and 2) bypassing a portion of the sCO 2 around the cooler to maintain the MCIT. These control methods reduce the effect of cycle feedback from interactions between the MCIT and load. When implementing either control method, a load setpoint ramp of 7.5%/min was maintainable while achieving closer load setpoint tracking with limited oscillations. Finally, the impact of sensor noise on the control was examined since derivative action was used in the IGV and cooler sCO 2 bypass control. Finally, while some effect was evident, signal noise was not problematic to the control.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Thermal Hydraulic Modeling of an Advanced Nuclear Reactor using open-source MOOSE tools

The aim of this study is to develop model of a small High Temperature Gas cooled Reactor (HTGR) including the balance of plant. This microreactor produces electricity using the thermal power of the nuclear reaction. This work utilizes the MOOSE Multiphysics simulation tools, which are mainly developed at Idaho National Laboratory (INL, Idaho, United States of America). Its thermal-hydraulics and Heat conduction Modules are used to study the fluids behavior in the primary loop and power conversion system and their interactions with the heating structures. More specifically, one verifies that the temperatures, pressures and mass flow rates of the fluids in both loops are consistent and that, at the same time, all the power transfers occur as expected. Moreover, the various mechanical components characteristics (turbine, compressor, pump) are adapted to the reactor operating conditions. This first analysis is conducted using simplified and one-dimensional model for the core. Ultimately, the obtained results are used to build a higher fidelity core model. This step aims to verify that the initial simplified simulation is consistent with the three-dimensional core modeling. In addition, the calculated material temperatures are checked. This study provides a fairly complete model of the thermal hydraulic phenomena for a particular design of High Temperature Gas cooled Reactor.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Experimental Evaluation of a High-Performance Cold-Climate Heat Pump Using Tandem Vapor-Injection Compressors

A high-performance cold-climate heat pump (CCHP) was developed and experimentally validated through comprehensive laboratory and field testing. The system utilized two equal-size tandem vapor-injection (VI) compressors with an inter-stage flash tank to improve efficiency and capacity retention under subfreezing conditions. Laboratory testing was conducted on a 3-ton prototype in a controlled environmental chamber equipped with calibrated thermocouples, refrigerant-side mass flow and pressure transducers, and precision airflow measurement for energy balance verification. The prototype achieved heating coefficients of performance (COPs) of 4.4 at 47 °F, 3.1 at 17 °F, and 2.0 at –13 °F, while maintaining 88% of its rated heating capacity at –13°F. These results confirm strong low-temperature performance and indicate the potential for significant reductions in electric resistance backup use. A field prototype was installed and monitored in a residential building in Fairbanks, Alaska, during a heating season. Instrumentation included real-time power, temperature, and refrigerant state measurements to evaluate performance under dynamic outdoor conditions. The heat pump operated reliably down to –30 °F, delivering 75% of its rated heating capacity with a COP of 1.8, while maintaining stable operation, effective defrost control, and indoor comfort without auxiliary heating. The combined laboratory and field results demonstrate that the tandem VI compressor configuration provides a practical and energy-efficient approach for residential heat pumps designed for cold and very cold climate regions.

Hu, Yifeng [ORNL] (ORCID:0000000242875185)↗

Engine system and method including first and second turbochargers

An engine system includes an internal combustion engine having an intake passage, a first set of combustion chambers, a second set of combustion chambers, a first exhaust passage fluidly connected to the first set of combustion chambers, and a second exhaust passage fluidly connected to the second set of combustion chambers. The engine system includes a first turbocharger including a first compressor and a first turbine. The engine system also includes a second turbocharger including a second compressor and a second turbine, the second compressor connected in series with the first compressor, and the second turbine being in fluid communication with the second exhaust passage. The first and second turbines are connected in parallel such that the first turbine only receives exhaust flow from the first set of combustion chambers, and the second turbine only receives exhaust flow from the second set of combustion chambers.

Lusardi, Christopher↗

Engine and fuel cell system including first and second turbochargers

An engine system includes an internal combustion engine, a fuel cell system, a first turbocharger and a second turbocharger. The internal combustion engine has an intake passage, and a first exhaust passage fluidly connected to the first set of combustion chambers. The first turbocharger has a first compressor and a first turbine. The second turbocharger has a second compressor and a second turbine, the second compressor connected in series with the first compressor, and the second turbine being in fluid communication with the second exhaust passage. The first and second turbines are connected in parallel such that the first turbine only receives exhaust flow from the fuel cell system, and the second turbine only receives exhaust flow from the internal combustion engine.

Lusardi, Christopher↗

Development of Real-Time System Identification to Detect Abnormal Operations in a Gas Turbine Cycle

Here, we present a novel online system identification methodology for monitoring the performance of power systems. This methodology was demonstrated in a gas turbine recuperated power plant designed for a hybrid configuration. A 120-kW Garrett microturbine modified to test dynamic control strategies for hybrid power systems designed at the National Energy Technology Laboratory (NETL) was used to implement and validate this online system identification methodology. The main component of this methodology consists of an empirical transfer function model implemented in parallel to the turbine speed operation and the fuel control valve, which can monitor the process response of the gas turbine system while it is operating. During fully closed-loop operations or automated control, the output of the controller, fuel valve position, and the turbine speed measurements were fed for a given period of time to a recursive algorithm that determined the transfer function parameters during the nominal condition. After the new parameters were calculated, they were fed into the transfer function model for online prediction. The turbine speed measurement was compared against the transfer function prediction, and a control logic was implemented to capture when the system operated at nominal or abnormal conditions. To validate the ability to detect abnormal conditions during dynamic operations, drifting in the performance of the gas turbine system was evaluated. A leak in the turbomachinery working fluid was emulated by bleeding 10% of the airflow from the compressor discharge to the atmosphere, and electrical load steps were performed before and after the leak. This tool could detect the leak 7 s after it had occurred, which accounted for a fuel flow increase of approximately 15.8% to maintain the same load and constant turbine speed operations.

algorithms↗

Method and apparatus for reduction of water re-evaporation in a dedicated dehumidifier/water heater

An apparatus that includes a refrigeration circuit that includes an evaporator, a first condenser and a compressor. The apparatus includes a refrigerant-water heat exchanger that includes a second condenser fluidly coupled to the refrigeration circuit. A control valve is operatively connected to the refrigeration circuit to direct flow of refrigerant through at least one of the first condenser during a dehumidification mode and the second condenser during a water heating mode. A damper is disposed on an upwind side of the evaporator, the damper being operable to reduce airflow across the evaporator during a ventilation mode.

42 ENGINEERING↗

Method and apparatus for reduction of water re-evaporation in a dedicated dehumidifier/water heater

An apparatus that includes a refrigeration circuit that includes an evaporator, a first condenser and a compressor. The apparatus includes a refrigerant-water heat exchanger that includes a second condenser fluidly coupled to the refrigeration circuit. A control valve is operatively connected to the refrigeration circuit to direct flow of refrigerant through at least one of the first condenser during a dehumidification mode and the second condenser during a water heating mode. A damper is disposed on an upwind side of the evaporator, the damper being operable to reduce airflow across the evaporator during a ventilation mode.

Uselton, Robert B.↗

Direct Expansion Heat Pump Using High Glide Low GWP Refrigerant

Next generation of refrigerants require drastically lower global warming potential (GWP). The refrigerant mixtures, with a GWP < 150, e.g., R-457A, etc., tend to have significant temperature glide, which prefer multi-row, cross counter flow configuration. Typical heat pump operation reverses the refrigerant flow direction, compared to the air flow, from cooling mode to heating mode. It is difficult to configurate cross counter-flow heat exchangers in heat pumps. We invented an innovative configuration, having check valve assembly to maintain uniform cross counter flow configuration in both cooling and heat modes, which optimizes the performance of a high temperature slide refrigerant mixture, i.e. R-457A. Based on it, we developed a laboratory prototype, using a 2-stage compressor, achieved a cooling SEER (cooling seasonal energy efficiency rating) of 16.0 (cooling seasonal COP of 4.69) and a heating HSPF (heating seasonal performance factor) > 9.5 (heating seasonal COP of 2.78). The unit was tested in an extensive ambient condition, heating operation from 5˚F to 62˚F (-15˚C to 16.7˚C); cooling operation from 82˚F to 95˚F (27.8˚C to 35˚C). The paper will introduce the system configuration, heat exchanger dimensions and laboratory investigations.

Shen, Bo↗

Low global warming potential (GWP) refrigerant supermarket refrigeration system modeling and its application

As an environmentally friendly low global warming potential (GWP) refrigerant, Carbon dioxide (CO 2 ) has continuously gained popularity and research attention as alternative refrigerant for supermarket refrigeration system. In this paper, to fulfill the increasing need of accurate Low-GWP supermarket refrigeration models for development of supervisory level control and optimization strategies, a high fidelity model is developed for CO 2 transcritical supermarket refrigeration system which includes compressor rack of low temperature (LT) compressors and medium temperature (MT) compressors, air-cooled gas cooler, evaporator, expansion valves and other auxiliary equipment. A resistance-capacity model structure is proposed to simulate the display cases. Semi-thermodynamic models are proposed to estimate reciprocating compressors volumetric efficiency and power consumption. Furthermore the zone modeling approach is used for evaporator simulation, and air-cooled gas cooler is modeled with distributed modeling method. The expansion valve simulation is based on orifice flow model. To calibrate these models, both manufacture performance data and experimental data are used. The experiments are conducted with a full instrumental CO 2 supermarket refrigeration system installed in Oak Ridge National Lab Flexible Research Platform (FRP). The simulation model can predict the system performance, including power consumption, cooling capacity, mass flow rate, temperature, and pressure, with high accuracy (within ±4%) compared to experimental data. In addition, this developed model has been used to create the system optimum high side pressure for high side expansion valve control, and to generate wide operating range simulation data for developing the batter-equivalent commercial refrigeration system model which can be used in grid interactive control development.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

High-temperature seals for supercritical carbon-dioxide (sCO 2 ) turbines (Final Report)

This is the final report for project DE-FE0031924 titled “High-temperature seals for supercritical carbon-dioxide (sCO 2 ) turbines.” The report provides a summary of the entire project efforts from October 2020 through December 2024 including the high-temperature commercial dry gas seal (DGS) tests and thermal modeling of Task 2, as well as the high-temperature, large-diameter seal design and high-temperature tests of large-diameter seals in Task 3. A key outcome of Task 2 was the testing completion of specially instrumented commercial DGS in the GE-SwRI Apollo sCO 2 compressor (27,000 rpm). Test data from the DGS showed elevated temperatures upwards of 350 o F, which are close to the higher operating temperature limit of the DGS. The temperature measurements provide insight into the expected thermal loads on DGS operating in high-speed sCO 2 compressor and provided test data for validation of an in-house thermal model of the compressor/seal. Under Task 2.0, this report also presents the development of a steady-state conjugate heat-transfer model of the DGS operating in the sCO 2 compressor – a first of its kind model for modeling heat transfer of sCO 2 in an actual operating compressor. The findings of the thermal model show a reasonable match between temperature predictions of the model and the measured temperature data, also pointing out the validity of the approach and assumptions made in modeling the flows, heat transfer coefficients and windage modeling in the rig. Under Task 3.0, this report presents the preliminary design of a large-diameter hybrid face seal (14 inch and 26-inch diameter) for field testing in a land-based GE turbine. The preliminary seal design effort presented in this report under project DE-FE0031924 builds on the development and successful laboratory testing for such large diameter hybrid face seal under the prior DE-FE0024007 project. Key aspects of seal fluid analyses with CFD, mechanical design considerations and assembly considerations in a land-based turbine are presented. Finally, under Task 3.0, this report also presents the continued high-temperature testing of the 14-inch diameter hybrid face seal developed previously under the DE-FE0024007 program. Specifically, test data demonstrating successful non-contact seal operation and seal effective leakage of 0.001-inch with seal inlet temperatures above 700 o F are presented in this report. Successful hybrid seal operation in a laboratory environment for a large diameter (14-inch) seal at temperatures above 700 o F is a major technological milestone for this technology.

01 COAL, LIGNITE, AND PEAT↗

An Update on the Status of a Reduced Flow Test of a 10MW 700°C sCO2 Integrally Geared Compander

. In order to maintain viability as a future power-generating technology, concentrating solar power (CSP) must reduce its levelized cost of electricity (LCOE). One component of solving this problem is reducing the cost of the power block while simultaneously increasing the efficiency of the thermodynamic cycle. One disruptive technology that has the promise to accomplish this is supercritical CO2 based power cycles. These cycles are conceptually similar to steam cycles; however, they have substantially smaller turbomachinery at equivalent power while also delivering more efficiency at turbine inlet temperatures of 500-700 degrees Celsius. This paper will summarize the current status of a US Department of Energy project to develop machinery to support a 10 MW sCO2 power cycle. The team of Southwest Research Institute® (SwRI®) and Hanwha Power Systems America, proposed to develop an integrally-geared (IG) compressor-expander (compander) for use in a nominal 10 MW-scale concentrated solar power (CSP) supercritical carbon dioxide (sCO2) plant application. This integrally-geared compander (IGC) comprises multiple pinion shafts interconnected on a single bull gear to create a compact package, and utilizes a low-cost, low-speed driver. In addition, the integrally geared architecture allows each pinion to operate at different rotational speeds to optimize performance and easily allow for inter-stage cooling and turbine re-heat to further enhance both stage and cycle efficiency. The close integration of all turbomachinery elements into a single integrally-geared (IG) machine creates a design that lends itself to power block modularization, which makes it suitable for waste heat recovery, fossil fuel power plants, and especially CSP applications. As part of the commercialization of this technology, it is necessary to reduce risk by validation testing of key components. In the current work, the focus is developing a test loop to enable safe testing of the main compressor stage across a wide range of operating conditions, and to validate the mechanical integrity of the turbine at full pressure, temperature, and speed. Developing a test loop for sCO2 requires balancing a number of design alternatives that impact cost, lead time, safety, and performance. The current work discusses the design process for the reduced flow test loop for the compander, and supporting documentation supporting the viability of the test loop

wilkes, jason↗

Fuel driven near isothermal compressor

A gas compressor system includes a compression liquid holding tank in fluid communication with a combustion tank. A combustible fluid is directed to the combustion tank. An ignition system is provided for igniting the combustible fluid. A compression liquid flows between the liquid holding tank, the combustion tank, and a compression tank. A compressible gas is provided in the compression tank. The ignition of the combustible fluid drives the compression liquid from the combustion tank to the compression tank, compressing the compressible liquid. An HVAC&R system and a method of compressing gas are also disclosed.

Momen, Ayyoub Mehdizadeh↗

Multi-Split Variable Refrigerant Flow (VRF) System Building Energy Simulations Using Performance Maps

Multi-split variable refrigerant flow (VRF) systems are highly energy-efficient HVAC (heating, ventilation and air conditioning) technologies that connect a single outdoor unit to multiple independent indoor terminal units using a common refrigerant circuit and a variable-speed compressor. Building energy simulations that incorporate VRF systems help model their unique operational characteristics and predict energy consumption in specific building designs. Traditionally, EnergyPlus models these systems by employing multiple sets of performance curves to characterize both individual terminal units and the outdoor unit. However, producing these curves is labor intensive and error prone, and they often do not capture all the key input and output variables. This paper introduces a novel approach that uses multi-dimensional performance maps to model VRF systems in building environments for space cooling. In this approach, performance maps are developed at the component level—separately for the outdoor unit and for each indoor terminal. The new modeling method is validated within EnergyPlus via a Python plug-in that contains a simple solver loop to coordinate the component-level, indoor, and outdoor unit maps. Furthermore, because performance maps can span more variables than traditional performance curves, they offer the opportunity to implement advanced controls, such as enhanced dehumidification and compressor modulation. A VRF air conditioner’s hardware system was modeled using the DOE/ORNL Heat Pump Design Model, which was automated to produce extensive performance maps for both the indoor and outdoor units.

Shen, Bo [ORNL] (ORCID:0000000336600393)↗

Experimental results of a magnetically coupled piezoelectric actuator to relieve microchannel heat exchanger maldistribution

Refrigerant maldistribution is a common issue in microchannel heat exchangers. Refrigerant maldistribution can have significant negative effects on the heat transfer performance and increase the pressure drop, leading to increased superheat temperature at the outlet and increased compressor work, lowering system efficiency. In this work, a novel piezoelectric-driven magnetic actuator (PEDMA) was fabricated and inserted into the inlet header of the microchannel evaporator, with the goal of improving the non-uniformity of the flow distribution by regulating the flow in the header to the microchannels. Two prototype PEDMA designs were tested and showed significant impact on the refrigerant flow in the region of actuation. In the first design, the experimental data showed superheat reductions up to 9 °C when the individual channel temperatures were measured. The second design redistributed the refrigerant such that a 1% increase in capacity was calculated for the whole heat exchanger without significantly impacting the heating efficiency. The experimental results demonstrate the successful operation of the PEDMA devices and represent a new method of active flow distribution control which is based on a simple design with minimal additional energy consumption, and which can be inserted into microchannel heat exchanger headers to potentially relieve the refrigerant maldistribution.

42 ENGINEERING↗

Multi-physics Modeling of Radiative Heat Transfer and Fluid Flow for the Reactor Cavity Cooling System

High-temperature gas-cooled reactors (HTGRs) are notable for their high thermal efficiency and potential for combined heat and power applications. These reactors are particularly appealing due to their advanced passive safety features. HTGRs utilize passive safety systems that function without requiring active components like pumps or compressors during emergencies. These reactor designs depend on a Reactor Cavity Cooling System (RCCS) to manage decay heat removal from the reactor pressure vessel (RPV) during accident conditions. The RCCS consists of vertical rectangular channels known as "risers" or riser ducts positioned around the RPV. These risers receive heat from the RPV through both convective and radiative heat transfer mechanisms. Understanding the interplay of multiple physical phenomena, such as fluid dynamics, heat transfer, and neutron interactions, is essential for the effective design and operation of nuclear reactors, particularly for systems like the RCCS. Multi-physics simulations provide a comprehensive approach to studying these interactions, offering detailed insights and enhancing accuracy. They are especially important in RCCS designs, where the interaction between radiative and convective heat transfer can significantly impact system performance. By leveraging multi-physics simulations, complex reactor behaviors can be modeled without compromising the fidelity of the underlying physical processes. This work aims to establish a robust methodology for coupling multiple physical processes in an air-cooled RCCS. By focusing on validating this multi-physics approach, the study involves designing test cases that simulate various conditions to verify the numerical models employed. The outcomes of this research will provide critical insights for accurately modeling and optimizing complex nuclear systems like the RCCS.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗