Search NASA⌕ Search

SEARCH · Search NASA

Results for “CONCENTRATOR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

The role of electron concentration in softening and hardening of ternary molybdenum alloys

An investigation was conducted to determine softening and hardening behavior in ternary Mo alloys and to correlate these effects with electron concentration. Results showed that the hardness behavior of ternary Mo alloys could be correlated with results anticipated from binary data based upon expressions involving the number of s + d electrons contributed by the solute elements. It was further shown that combining alloying elements at concentrations that produce the maximum amount of softening in Mo does not result in additive softening in ternary Mo alloys. Once a critical electron concentration is exceeded, only alloy hardening is observed. A comparison of hardness behavior with literature data on Hall coefficient and magnetic susceptibility for W-Re alloys showed that hardness minima occur at Re concentrations where minima are observed for the physical property measurements. These observations, and the correlation of hardness with electron concentration, support the hypothesis that alloy softening in Group VI metals is an intrinsic characteristic of these metals and that electron concentration plays the dominant role in controlling hardness.

Stephens, J. R.↗

An analysis for designing solar concentrator-collector configurations

An analysis for predicting the heat flux distribution on collectors in the focal region of solar concentrators has been formulated. The analysis is rather general and can consider limb darkening effects, collector placement errors, concentrator optical errors, and concentrator pointing errors. By coupling finite differencing techniques and heating requirements to this analysis, it can also be used to design concentrators that give prescribed heating on the collector surface. Illustrative results are presented. It is concluded that the concentrator and collector should be designed as a unit and that concentrator configurations that are more desirable than the paraboloid and cylindrical parabola can be designed.

Mcdermit, J. H.↗

Segregation of acid plume pixels from background water pixels, signatures of background water and dispersed acid plumes, and implications for calculation of iron concentration in dense plumes

Two files of data, obtained with a modular multiband scanner, for an acid waste dump into ocean water, were analyzed intensively. Signatures were derived for background water at different levels of effective sunlight intensity, and for different iron concentrations in the dispersed plume from the dump. The effect of increased sunlight intensity on the calculated iron concentration was found to be relatively important at low iron concentrations and relatively unimportant at high values of iron concentration in dispersed plumes. It was concluded that the basic equation for iron concentration is not applicable to dense plumes, particularly because lower values are indicated at the very core of the plume, than in the surrounding sheath, whereas radiances increase consistently from background water to dispersed plume to inner sheath to innermost core. It was likewise concluded that in the dense plume the iron concentration would probably best be measured by the higher wave length radiances, although the suitable relationship remains unknown.

Bahn, G. S.↗

Reduction of intensity variations on a photovoltaic array with compound parabolic concentrators

The reduction of nonuniformities in the intensity distribution of light focused on a photovoltaic array by a compound parabolic concentrator is investigated. The introduction of small distortions into the surfaces of the reflector in order to diffuse the incident collimated light to fill the angular acceptance of the concentrator is calculated by means of ray tracing to decrease the irradiance nonuniformity at the cost of a lowered effective concentration of the concentrator. Measurements of the intensity distribution on a scale test model in terrestrial sunlight with corrugated aluminized mylar reflectors are shown to be in good agreement with the ray tracing results. A two-stage concentrator consisting of a focusing primary and a nonimaging secondary is also shown to result in a fairly uniform intensity distribution except in the case of a 4-deg incidence angle, which may be corrected by the introduction of distortions into one or both concentration stages.

Greenman, P.↗

Variation of Local Liquid-Water Concentration About and Ellipsoid of Fineness Ratio 5 Moving in a Droplet Field

Trajectories of water droplets about an ellipsoid of revolution with a fineness ratio of 5 (which often approximates the shape of an aircraft fuselage or missile) were computed with the aid of a differential analyzer. Analyses of these trajectories indicate that the local concentration of liquid water at various points about an ellipsoid in flight through a droplet field varies considerably and under some conditions may be several times the free-stream concentration. Curves of the local concentration factor as a function of spatial position were obtained and are presented in terms of dimensionless parameters Re(sub 0) (free-stream Reynolds number) and K (inertia), which contain flight and atmospheric conditions. These curves show that the local concentration factor at any point is very sensitive to change in the dimensionless parameters Re(sub 0) and K. These data indicate that the expected local concentration factors should be considered when choosing the location of, or when determining antiicing heat requirements for, water- or ice-sensitive devices that protrude into the stream from an aircraft fuselage or missile. Similarly, the concentration factor should be considered when choosing the location on an aircraft of instruments that measure liquid-water content or droplet-size distribution in the atmosphere.

Dorsch, Robert G.↗

Ambient airborne solids concentrations including volcanic ash at Hanford, Washington sampling sites subsequent to the Mount St. Helens eruption

Airborne solids concentrations were measured on a near daily basis at two Hanford, Washington sites after the eruption of Mount St. Helens on May 18, 1980. These sites are about 211 km east of Mount St. Helens. Collected airborne solids included resuspended volcanic ash plus normal ambient solids. Average airborne solids concentrations were greater at the Hanford meteorological station sampling site which is 24 km northwest of the Horn Rapids dam sampling site. These increased concentrations reflect the sampling site proximity to greater ash fallout depths. Both sites are in low ash fallout areas although the Hanford meteorological station site is closer to the greater ash fallout areas. Airborne solids concentrations were decreased by rain, but airborne solids concentrations rapidly increased as surfaces dried. Airborne concentrations tended to become nearly the same at both sampling sites only for July 12 and 13.

Sehmel, G. A.↗

Relative potentials of concentrating and two-axis tracking flat-plate photovoltaic arrays for central-station applications

The purpose of this study is to assess the relative economic potentials of concenrating and two-axis tracking flat-plate photovoltaic arrays for central-station applications in the mid-1990's. Specific objectives of this study are to provide information on concentrator photovoltaic collector probabilistic price and efficiency levels to illustrate critical areas of R&D for concentrator cells and collectors, and to compare concentrator and flat-plate PV price and efficiency alternatives for several locations, based on their implied costs of energy. To deal with the uncertainties surrounding research and development activities in general, a probabilistic assessment of commercially achievable concentrator photovoltaic collector efficiencies and prices (at the factory loading dock) is performed. The results of this projection of concentrator photovoltaic technology are then compared with a previous flat-plate module price analysis (performed early in 1983). To focus this analysis on specific collector alternatives and their implied energy costs for different locations, similar two-axis tracking designs are assumed for both concentrator and flat-plate options.

Borden, C. S.↗

Designing generalized conic concentrators for conventional optical systems

Generalized nonimaging concentrators can be incorporated into conventional optical systems in situations where flux concentration rather than imaging is required. The parameters of the concentrator for maximum flux concentration depend on the design of the particular optical system under consideration. Rationale for determining the concentrator parameters is given for one particular optical system and the procedure used for calculation of these parameters is outlined. The calculations are done for three concentrators applicable to the optical system.

Eichhorn, W. L.↗

Stress concentration around a small circular hole in the HiMAT composite plate

Anisotropic plate theory is used to calculate the anisotropic stress concentration factors for a composite plate (AS/3501-5 graphite/epoxy composite, single ply or laminated) containing a circular hole. This composite material is used on the highly maneuverable aircraft technology (HiMAT) vehicle. It is found that the anisotropic stress concentration factor could be greater or less than 3 (the stress concentration factor for isotropic materials), and that the locations of the maximum tangential stress points could shift with the change of fiber orientation with respect to the loading axis. The effect of hole size on the stress concentration factor is examined using the Point Stress Criterion and the Averaged Stress Criterion. The predicted stress concentration factors based on the two theories compared fairly well with the measured values for the hole size 0.3175 cm (1/8 in). It is also found that through the lamination process, the stress concentration factor could be reduced drastically, indicating an improvement in structural performance.

Ko, W. L.↗

High-performance deployable structures for the support of high-concentration ratio solar array modules

A study conducted on high-performance deployable structures for the support of high-concentration ratio solar array modules is discussed. Serious consideration is being given to the use of high-concentration ratio solar array modules or applications such as space stations. These concentrator solar array designs offer the potential of reduced cost, reduced electrical complexity, higher power per unit area, and improved survivability. Arrays of concentrators, such as the miniaturized Cassegrainian concentrator modules, present a serious challenge to the structural design because their mass per unit area (5.7 kg/square meters) is higher than that of flexible solar array blankets, and the requirement for accurate orientation towards the Sun (plus or minus 0.5 degree) requires structures with improved accuracy potentials. In addition, use on a space station requires relatively high structural natural frequencies to avoid deleterious interactions with control systems and other large structural components. The objective here is to identify and evaluate conceptual designs of structures suitable for deploying and accurately supporting high-concentration ratio solar array modules.

Mobrem, M.↗

Structural concepts for large solar concentrators

The Sunflower large solar concentrator, developed in the early 1970's, is a salient example of a high-efficiency concentrator. The newly emphasized needs for solar dynamic power on the Space Station and for large, lightweight thermal sources are outlined. Existing concepts for high efficiency reflector surfaces are examined with attention to accuracy needs for concentration rates of 1000 to 3000. Concepts using stiff reflector panels are deemed most likely to exhibit the long-term consistent accuracy necessary for low-orbit operation, particularly for the higher concentration ratios. Quantitative results are shown of the effects of surface errors for various concentration and focal-length diameter ratios. Cost effectiveness is discussed. Principal sources of high cost include the need for various dished panels for paraboloidal reflectors and the expense of ground testing and adjustment. A new configuration is presented addressing both problems, i.e., a deployable Pactruss backup structure with identical panels installed on the structure after deployment in space. Analytical results show that with reasonable pointing errors, this new concept is capable of concentration ratios greater than 2000.

Hedgepeth, John M.↗

Stress concentration around circular hole in a composite material specimen representative of the X-29A forward-swept wing aircraft

The theory of anisotropic elasticity was used to evaluate the anisotropic stress concentration factors of a composite laminated plate containing a small circular hole. This advanced composite material was used to manufacture the X-29A forward swept wing. Observe that the usual isotropic material stress concentration factor is three. However, for composite material, it was found that the anisotropic stress concentration factor is no longer constant, and that the locations of maximum tangential stress points could shift by changing the fiber orientation with respect to the loading axis. The analysis showed that through the lamination process, the stress concentration factor could be drastically reduced, and therefore the structural performance could be improved. Both the mixture rule approach and the constant strain approach were used to calculate the stress concentration factor. The results predicted by the mixture rule approach were about 20 percent deviate from the experimental data. However, the results predicted by the constant strain approach matched the testing data very well. This showed the importance of the inplane shear effect on the evaluation of stress concentration factor for the X-29A composite plate.

Yeh, Hsien-Yang↗

Development of a dome Fresnel lens/gallium arsenide photovoltaic concentrator for space applications

A novel photovoltaic concentrator system is currently being developed. Phase I of the program, completed in late 1986, produced a conceptual design for the concentrator system, including an array weight and performance estimates based on optical, electrical, and thermal analyses. Phase II of the program, just underway, concerns the fabrication and testing of prototype concentrator panels of the design. The concentrator system uses dome Fresnel lenses for optical concentration; gallium arsenide concentrator cells for power generation; prismatic cell covers to eliminate gridline obscuration losses; a backplane radiator for heat rejection; and a honeycomb structure for the deployable panel assembly. The conceptual design of the system, its anticipated performance, and its estimated weight are reported.

O'Neill, Mark J.↗

Technology development program for an advanced microsheet glass concentrator

Solar Dynamic Space Power Systems are candidate electrical power generating systems for future NASA missions. One of the key components in a solar dynamic power system is the concentrator which collects the sun's energy and focuses it into a receiver. In 1985, the NASA Lewis Research Center initiated the Advanced Solar Dynamic Concentrator Program with funding from NASA's Office of Aeronautics and Space Technology (OAST). The objectives of the Advanced Concentrator Program is to develop the technology that will lead to lightweight, highly reflective, accurate, scaleable, and long lived (7 to 10 years) space solar dynamic concentrators. The Advanced Concentrator Program encompasses new and innovative concepts, fabrication techniques, materials selection, and simulated space environmental testing. The Advanced Microsheet Glass Concentrator Program, a reflector concept, that is currently being investigated both in-house and under contract is discussed.

Richter, Scott W.↗

Conceptual design of a self-deployable, high performance parabolic concentrator for advanced solar-dynamic power systems

A summary is presented of the concentrator conceptual design work performed under a NASA-funded project. The design study centers around two basic efforts: conceptual design of a self-deploying, high-performance parabolic concentrator; and materials selection for a lightweight, shape-stable concentrator. The primary structural material selected for the concentrator is PEEK/carbon fiber composite. The deployment concept utilizes rigid gore-shaped reflective panels. The assembled concentrator takes a circular shape with a void in the center. The deployable solar concentrator concept is applicable to a range of solar dynamic power systems of 25 kWe to more than 75 kWe.

Dehne, Hans Joachim↗

Electron temperature and concentration in a thermal atomic oxygen source

A thermal atomic oxygen source for materials screening was built for NASA by Boeing Aerospace. The objective here was to use a microwave interferometer and Langmuir probe to characterize the electron concentration in this thermal atomic oxygen source. Typical operating conditions in the thermal atomic oxygen source were found to produce electron concentrations that were well below the detection threshold of the interferometer (10(exp 8) cm (sup -3)). The researchers calibrated (with the interferometer) the Langmuir probe at an artificially high plasma density and then used the circular and the square Langmuir probes to measure the low electron concentrations that exist during materials exposure tests. Electron concentration was measured as a function of power and position. The electrons were lost to the walls through ambipolar diffusion, and their concentration was accurately described by an equation. The electron concentration was proportional to power squared and decayed exponentially with distance.

Pedrow, Patrick Dennis↗

Effects of off-axis radiation on reflective concentrating systems for space power

Off-axis incident radiation, resulting from misalignment of a concentrator relative to incident solar flux, can potentially result in high flux concentrations at positions other than the design focal point. It is suggested that the impact of these concentrations should be considered when choosing materials and thermal control strategies for structures adjacent to the concentrator. A numerical (ray tracing) analysis of the effects of off-axis radiation on the proposed solar concentrator for the Space Station Freedom is performed. The magnitude and position of the reflected flux peaks are identified for a matrix of off-axis angles and target distances. The principles of geometric optics are presented to illustrate that the results of the numerical study are justified, and these results are explained in terms of these basic optical principles. A method that allows prediction of the reflected flux field for a generalized parabolic reflective concentrating system is presented.

Campbell, J. S.↗

NASA team algorithm for sea ice concentration retrieval from Defense Meteorological Satellite Program special sensor microwave imager - Comparison with Landsat satellite imagery

The present study describes the validation of the the NASA team algorithm for the determination of sea ice concentrations from the Defense Meteorological Satellite Program special sensor microwave imager (SSM/I). A total of 28 cloud-free Landsat scenes were selected to permit validation of the passive microwave ice concentration algorithm for a range of ice concentrations and ice types. The sensitivity of the NASA team algorithm to the selection of locally and seasonally adjusted algorithm parameters is discussed. Mean absolute differences between SSM/I and Landsat ice concentrations are within 1 percent during fall using local and global tie points (standard deviations of the difference are +/-3.1 and +/-6.2 percent, respectively). In areas with greater amounts of nilas and young ice, the NASA team algorithm was found to underestimate ice concentrations by as much as 9 percent. It is inferred that the standard deviation between SSM/I and Landsat ice concentrations decreases from +/-7 to +/-5 percent with local tie points compared to the global ones for spring and fall.

Steffen, Konrad↗