Cold-air study of the effect on turbine stator blade aerodynamic performance of coolant ejection from various trailing-edge slot geometries. 1: Experimental results

Trailing-edge slot configurations were investigated in a two-dimensional cascade of turbine stator blades. The trailing-edge slots were incorporated into blades with round trailing edges. The five blade configurations investigated included blades with two different trailing-edge thicknesses and four different slot widths. The results of the investigation showed that there was, in general, a significant increase in primary-air efficiency due to the coolant flow, the increase varying with slot configuration. For the five configurations tested, the average percent change in primary-air efficiency per percent coolant flow varied almost linearly from zero to about 1.4 percent over a range of coolant- to primary-air exit-velocity ratios between 0 and 1.2. However, for different configurations there was considerable deviation from the average values in the lower range of exit velocity ratios.

Prust, H. W., Jr.↗

Analysis of metal temperature and coolant flow with a thermal-barrier coating on a full-coverage-film-cooled turbine vane

The potential benefits of combining full-coverage film cooling with a thermal-barrier coating were investigated analytically for sections on the suction and pressure sides a high-temperature, high-pressure turbine vane. Metal and ceramic coating temperatures were calculated as a function of coating thickness and coolant flow. With a thermal-barrier coating, the coolant flows required for the chosen sections were half those of an uncoated design, and the metal outer temperatures were simultaneously reduced by over 111 K (200 F). For comparison, transpiration cooling was also investigated. Full-coverage film cooling of a coated vane required more coolant flow than did transpiration cooling.

Meitner, P. L.↗

Film-cooling effectiveness with developing coolant flow through straight and curved tubular passages

The data were obtained with an apparatus designed to determine the influence of tubular coolant passage curvature on film-cooling performance while simulating the developing flow entrance conditions more representative of cooled turbine blade. Data comparisons were made between straight and curved single tubular passages embedded in the wall and discharging at 30 deg angle in line with the tunnel flow. The results showed an influence of curvature on film-cooling effectiveness that was inversely proportional to the blowing rate. At the lowest blowing rate of 0.18, curvature increased the effectiveness of film cooling by 35 percent; but at a blowing rate of 0.76, the improvement was only 10 percent. In addition, the increase in film-cooling area coverage ranged from 100 percent down to 25 percent over the same blowing rates. A data trend reversal at a blowing rate of 1.5 showed the straight tubular passage's film-cooling effectiveness to be 20 percent greater than that of the curved passage with about 80 percent more area coverage. An analysis of turbulence intensity detain the mixing layer in terms of the position of the mixing interface relative to the wall supported the concept that passage curvature tends to reduce the diffusion of the coolant jet into the main stream at blowing rates below about. Explanations for the film-cooling performance of both test sections were made in terms differences in turbulences structure and in secondary flow patterns within the coolant jets as influenced by flow passage geometry.

Papell, S. S.↗

Analysis of coolant entrance boundary shape of porous region to control cooling along exit boundary

A cooled porous region has a plane surface exposed to a specified spatially varying heat flux. The coolant leaves the region through this surface, and it is desired to control the flow distribution to maintain a specified uniform surface temperature. This is accomplished by having the coolant entrance surface shaped to provide in the region the necessary variation of path length and, hence, flow resistance. The surface shape at the coolant entrance is found by solving a Cauchy boundary value problem. An exact solution is obtained that will deal with a wide variety of heating distributions for both two- and three-dimensional shapes.

Siegel, R.↗

Flow boiling with enhancement devices for cold plate coolant channel design

The use of flow boiling for thermal energy transport is intended to provide an alternative for accommodating higher heat fluxes in commercial space systems. The objectives are to: (1) examine the variations in both the mean and local (axial and circumferential) heat transfer coefficients for a circular coolant channel with either smooth walls, spiral fins, or both spiral fins and a twisted tape; (2) examine the effects of channel diameter and subcooling; and (3) develop an improved reduction analysis and/or suggest possible heat transfer correlation of the present data. Freon-11 is the working fluid. Two-dimensional (circumferential and axial) wall temperature distributions were measured for coolant channels with the above noted internal geometries. The flow regimes which are being studied are: (1) single phase; (2) subcooled flow boiling; and (3) stratified flow boiling. The inside diameter of all test sections is near 1.0 cm. Cicumferentially averaged heat transfer coefficients at several axial locations were obtained for selected coolant channels for a mass velocity of 210 kg/sq m s, an exit pressure of 0.19 MPa (absolute), and an inlet subcooling of 20.8 C. Overall (averaged over the entire channel) heat transfer coefficients were compared for the above channel geometries. This comparison showed that the channel with large pitch spiral fins had higher heat transfer coefficients at all power levels.

Boyd, Ronald D., Sr.↗

Subcooled freon-11 flow boiling in top-heated finned coolant channels with and without a twisted tape

An experimental study was conducted in top-heated finned horizontal tubes to study the effect of enhancement devices on flow boiling heat transfer in coolant channels. The objectives are to examine the variations in both the mean and local (axial and circumferential) heat transfer coefficients for circular coolant channels with spiral finned walls and/or spiral fins with a twisted tape, and improve the data reduction technique of a previous investigator. The working fluid is freon-11 with an inlet temperature of 22.2 C (approximately 21 C subcooling). The coolant channel's exit pressure and mass velocity are 0.19 M Pa (absolute) and 0.21 Mg/sq. ms, respectively. Two tube configurations were examined; i.e., tubes had either 6.52 (small pitch) or 4.0 (large pitch) fins/cm of the circumferential length (26 and 16 fins, respectively). The large pitch fins were also examined with a twisted tape insert. The inside nominal diameter of the copper channels at the root of the fins was 1.0 cm. The results show that by adding enhancement devices, boiling occurs almost simultaneously at all axial locations. The case of spiral fins with large pitch resulted in larger mean (circumferentially averaged) heat transfer coefficients, h sub m, at all axial locations. Finally, when twisted tape is added to the tube with large-pitched fins, the power required for the onset of boiling is reduced at all axial and circumferential locations.

Smith, Alvin↗

Computation of Space Shuttle high-pressure cryogenic turbopump ball bearing two-phase coolant flow

A homogeneous two-phase fluid flow model, implemented in a three-dimensional Navier-Stokes solver using computational fluid dynamics methodology is described. The application of the model to the analysis of the pump-end bearing coolant flow of the high-pressure oxygen turbopump of the Space Shuttle main engine is studied. Results indicate large boiling zones and hot spots near the ball/race contact points. The extent of the phase change of the liquid oxygen coolant flow due to the frictional and viscous heat fluxes near the contact areas has been investigated for the given inlet conditions of the coolant.

Chen, Yen-Sen↗

The cryogenic on-orbit liquid analytical tool (COOLANT) - A computer program for evaluating the thermodynamic performance of orbital cryogen storage facilities

The United States plans to establish a permanent manned presence at the Space Station Freedom in low earth orbit (LEO) and then carry out exploration of the solar system from this base. These plans may require orbital cryogenic propellant storage depots. The COOLANT program has been developed to analyze the thermodynamic performance of these depots to support design tradeoff studies. It was developed as part of the Long Term Cryogenic Storage Facility Systems Study for NASA/MSFC. This paper discusses the program structure and capabilities of the COOLANT program. In addition, the results of an analysis of a 200,000 lbm hydrogen/oxygen storage depot tankset using COOLANT are presented.

Taylor, W. J.↗

Thermal stratification potential in rocket engine coolant channels

The potential for rocket engine coolant channel flow stratification was computationally studied. A conjugate, 3-D, conduction/advection analysis code (SINDA/FLUINT) was used. Core fluid temperatures were predicted to vary by over 360 K across the coolant channel, at the throat section, indicating that the conventional assumption of a fully mixed fluid may be extremely inaccurate. Because of the thermal stratification of the fluid, the walls exposed to the rocket engine exhaust gases will be hotter than an assumption of full mixing would imply. In this analysis, wall temperatures were 160 K hotter in the turbulent mixing case than in the full mixing case. The discrepancy between the full mixing and turbulent mixing analyses increased with increasing heat transfer. Both analysis methods predicted identical channel resistances at the coolant inlet, but in the stratified analysis the thermal resistance was negligible. The implications are significant. Neglect of thermal stratification could lead to underpredictions in nozzle wall temperatures. Even worse, testing at subscale conditions may be inadequate for modeling conditions that would exist in a full scale engine.

Kacynski, Kenneth J.↗

Inverse design of a proper number, shapes, sizes, and locations of coolant flow passages

During the past several years we have developed an inverse method that allows a thermal cooling system designer to determine proper sizes, shapes, and locations of coolant passages (holes) in, say, an internally cooled turbine blade, a scram jet strut, a rocket chamber wall, etc. Using this method the designer can enforce a desired heat flux distribution on the hot outer surface of the object, while simultaneously enforcing desired temperature distributions on the same hot outer surface as well as on the cooled interior surfaces of each of the coolant passages. This constitutes an over-specified problem which is solved by allowing the number, sizes, locations and shapes of the holes to adjust iteratively until the final internally cooled configuration satisfies the over-specified surface thermal conditions and the governing equation for the steady temperature field. The problem is solved by minimizing an error function expressing the difference between the specified and the computed hot surface heat fluxes. The temperature field analysis was performed using our highly accurate boundary integral element code with linearly varying temperature along straight surface panels. Examples of the inverse design applied to internally cooled turbine blades and scram jet struts (coated and non-coated) having circular and non-circular coolant flow passages will be shown.

George S. Dulikravich↗

Effects of coolant parameters on steady state temperature distribution in phospheric-acid fuel cell electrode

The influence of thermophysical properties and flow rate on the steady-state temperature distribution in a phosphoric-acid fuel cell electrode plate was experimentally investigated. An experimental setup that simulates the operating conditions prevailing in a phosphoric-acid fuel cell stack was used. The fuel cell cooling system utilized three types of coolants to remove excess heat generated in the cell electrode and to maintain a reasonably uniform temperature distribution in the electrode plate. The coolants used were water, engine oil, and air. These coolants were circulated at Reynolds number ranging from 1165 to 6165 for water; 3070 to 6864 for air; and 15 to 79 for oil. Experimental results are presented.

Alkasab, K. A.↗

Chimera grids in the simulation of three-dimensional flowfields in turbine-blade-coolant passages

When computing flows inside geometrically complex turbine-blade coolant passages, the structure of the grid system used can affect significantly the overall time and cost required to obtain solutions. This paper addresses this issue while evaluating and developing computational tools for the design and analysis of coolant-passages, and is divided into two parts. In the first part, the various types of structured and unstructured grids are compared in relation to their ability to provide solutions in a timely and cost-effective manner. This comparison shows that the overlapping structured grids, known as Chimera grids, can rival and in some instances exceed the cost-effectiveness of unstructured grids in terms of both the man hours needed to generate grids and the amount of computer memory and CPU time needed to obtain solutions. In the second part, a computational tool utilizing Chimera grids was used to compute the flow and heat transfer in two different turbine-blade coolant passages that contain baffles and numerous pin fins. These computations showed the versatility and flexibility offered by Chimera grids.

Stephens, M. A.↗

Computing Flows Of Coolants In Turbomachines

Coolant Passage Flow (CPF) computer code developed to predict accurately coolant flow and heat transfer inside turbomachinery cooling passages (either radial or axial blading). Computes flow in one-inlet/one-outlet passage of any shape. Calculates rate of flow of coolant, temperature, pressure, velocity, and heat-transfer coefficients along passage. Integrates one-dimensional momentum and energy equations along defined flow path, taking into account change in area, addition or subtraction of mass, pumping, friction, and transfer of heat. Written in FORTRAN IV.

Meitner, P. L.↗

Flow in serpentine coolant passages with trip strips

Under the subject contract, an effort is being conducted at Scientific Research Associates, Inc. (SRA) to obtain flow field measurements in the coolant passage of a rotating turbine blade with ribbed walls, both in the stationary and rotating frames. The data obtained will be used for validation of computational tools and assessment of turbine blade cooling strategies. The configuration of the turbine blade passage model is given, and the measuring plane locations are given. The model has a four-pass passage with three 180 turns. This geometry was chosen to allow analyses of the velocity measurements corresponding to the heat transfer results obtained by Wagner. Two passes of the passage have a rectangular cross-section of 1.0 in x 0.5 in. Another two passes have a square cross-section of 0.5 in x 0.5 in. Trips with a streamwise pitch to trip height (P/e) = 5 and trip height to coolant passage width (e/Z) = 0.1, were machined along the leading and trailing walls. These dimensions are typical of those used in turbine blade coolant passages. The trips on these walls are staggered by the half-pitch. The trips are skewed at +/- 45 deg, and this allows the effect of trip orientation to be examined. Experiments will be conducted with flow entering the model through the 1.0 in x 0.5 in rectangular passage (Configuration C) and the 0.5 in x 0. 5 in square passage (Configuration D) to examine the effect of passage aspect ratio. Velocity measurements were obtained with a Reynolds number (Re) of 25,000, based on the hydraulic diameter of and bulk mean velocity in the half inch square passage. The coordinate system used in presenting the results for configurations C and D, respectively, is shown. The first, second and third passes of the passage will be referred to as the first, second and third passages, respectively, in later discussion. Streamwise distance (x) from the entrance is normalized by the hydraulic diameter (D). Vertical (y) and tangential (z) distances are normalized by the half passage height (H) and width (Z), respectively. The x coordinate and U component are positive in the streamwise direction. The y coordinate and V component are positive against gravity. The z coordinate and W component are positive in the direction of rotation. The velocities are normalized by the bulk mean velocity (Ub) of 3.44 m/s based on the half-inch square passage. The contours of the 1.0 in x 0.5 in and 0.5 in x 0.5 in passages were evaluated from 11 x 30 and 9 x 30 measurement grids, respectively.

Tse, D. G.-N.↗

Numerical Simulation of Non-Rotating and Rotating Coolant Channel Flow Fields

Future generations of ultra high bypass-ratio jet engines will require far higher pressure ratios and operating temperatures than those of current engines. For the foreseeable future, engine materials will not be able to withstand the high temperatures without some form of cooling. In particular the turbine blades, which are under high thermal as well as mechanical loads, must be cooled. Cooling of turbine blades is achieved by bleeding air from the compressor stage of the engine through complicated internal passages in the turbine blades (internal cooling, including jet-impingement cooling) and by bleeding small amounts of air into the boundary layer of the external flow through small discrete holes on the surface of the blade (film cooling and transpiration cooling). The cooling must be done using a minimum amount of air or any increases in efficiency gained through higher operating temperature will be lost due to added load on the compressor stage. Turbine cooling schemes have traditionally been based on extensive empirical data bases, quasi-one-dimensional computational fluid dynamics (CFD) analysis, and trial and error. With improved capabilities of CFD, these traditional methods can be augmented by full three-dimensional simulations of the coolant flow to predict in detail the heat transfer and metal temperatures. Several aspects of turbine coolant flows make such application of CFD difficult, thus a highly effective CFD methodology must be used. First, high resolution of the flow field is required to attain the needed accuracy for heat transfer predictions, making highly efficient flow solvers essential for such computations. Second, the geometries of the flow passages are complicated but must be modeled accurately in order to capture all important details of the flow. This makes grid generation and grid quality important issues. Finally, since coolant flows are turbulent and separated the effects of turbulence must be modeled with a low Reynolds number turbulence model to accurately predict details of heat transfer.

Rigby, David L.↗

Performance of the Extravehicular Mobility Unit (EMU) Airlock Coolant Loop Remediation (A/L CLR) Hardware - Final

An EMU water processing kit (Airlock Coolant Loop Recovery -- A/L CLR) was developed as a corrective action to Extravehicular Mobility Unit (EMU) coolant flow disruptions experienced on the International Space Station (ISS) in May of 2004 and thereafter. A conservative duty cycle and set of use parameters for A/L CLR use and component life were initially developed and implemented based on prior analysis results and analytical modeling. Several initiatives were undertaken to optimize the duty cycle and use parameters of the hardware. Examination of post-flight samples and EMU Coolant Loop hardware provided invaluable information on the performance of the A/L CLR and has allowed for an optimization of the process. The intent of this paper is to detail the evolution of the A/L CLR hardware, efforts to optimize the duty cycle and use parameters, and the final recommendations for implementation in the post-Shuttle retirement era.

Steele, John W.↗

International Space Station Active Thermal Control Sub-System On-Orbit Pump Performance and Reliability Using Liquid Ammonia as a Coolant

The International Space Station (ISS) contains two Active Thermal Control Sub-systems (ATCS) that function by using a liquid ammonia cooling system collecting waste heat and rejecting it using radiators. These subsystems consist of a number of heat exchangers, cold plates, radiators, the Pump and Flow Control Subassembly (PFCS), and the Pump Module (PM), all of which are Orbital Replaceable Units (ORU's). The PFCS provides the motive force to circulate the ammonia coolant in the Photovoltaic Thermal Control Subsystem (PVTCS) and has been in operation since December, 2000. The Pump Module (PM) circulates liquid ammonia coolant within the External Active Thermal Control Subsystem (EATCS) cooling the ISS internal coolant (water) loops collecting waste heat and rejecting it through the ISS radiators. These PM loops have been in operation since December, 2006. This paper will discuss the original reliability analysis approach of the PFCS and Pump Module, comparing them against the current operational performance data for the ISS External Thermal Control Loops.

Morton, Richard D.↗

Wrought FeCrAl alloy (C26M) cladding behavior and burst under simulated loss-of-coolant accident conditions

Cladding burst experiments for FeCrAl cladding were performed in the Severe Accident Test Station facility at Oak Ridge National Laboratory. These experiments were simulated using the BISON fuel performance code to better understand the cladding plastic behavior and failure under simulated loss-of-coolant accident conditions. 3D cladding surface boundary conditions were generated using composite axial and azimuthal profiles from experiment thermocouple data. To improve the simulation analysis capabilities in BISON for cladding burst behavior, new thermal creep, plasticity, and failure stress models specific to C26M, a wrought FeCrAl alloy, were developed and implemented. Initial cladding burst results indicated a general underprediction in the failure temperature of the six cladding burst simulations versus the observed failure temperatures. Close investigation of the experiment timing versus the underlying tensile test data revealed that, compared with the tensile specimens, the cladding tubes did not experience the same long holding time at high temperatures. New tensile tests were performed at high temperatures using a temperature ramp similar to the simulated loss-of-coolant accident experiments. These new tensile curves showed an approximately 80% increase in the ultimate tensile strength of the C26M alloy, indicating that a holding time of 10 min at 700 °C and 800 °C allows annealing to change the material microstructure. Using the updated tensile properties, the burst temperatures and stresses from the simulations showed remarkable agreement with the experimental results. This study was then extended by varying the initial pressure to highlight the burst temperature difference between standard Zircaloy-4 and C26M cladding under equivalent conditions. The results show that C26M has a burst temperature that is approximately 70–130 K greater than that of Zircaloy-4. In conclusion, these modeling predictions can be further improved by collecting high-temperature tensile data for C26M beyond the temperature ranges used in this work.