Search NASASearch

SEARCH · Search NASA

Results for “CORROSION RESISTANCE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Fabrication and Testing of Solid-Solution Strengthened Corrosion Resistant Alloys For Service in Molten Fluoride Environments

The demand for higher system thermal efficiencies requires the operation of power generation cycles and heat conversion systems at progressively higher temperatures. As the system operating temperature increases, existing materials may not provide adequate mechanical properties or environmental compatibility or both. There is an increasing commercial interest in the development and deployment of liquid-fueled Molten Salt Reactors (MSRs). Hastelloy®N, the highest performing candidate MSR structural alloy, is not capable of operations at temperatures above 700°C, thus limiting the performance of these systems. Using an Integrated Computational Materials Engineering (ICME)-approach and small laboratory scale heats, ORNL developed a class of patented alloys covered by U.S. Patent 9,435,011 B2, “Creep-resistant, Cobalt-free alloys for high temperature, liquid-salt heat exchanger systems,” similar to Hastelloy®N in that they are primarily solid solution strengthened. In contrast to precipitation strengthened alloys, the microstructure of solid solution alloys and hence the high temperature mechanical properties are stable for extended periods of time allowing long reactor operating life. The new alloys have shown to possess good resistance to liquid fluorides at temperatures up to 850°C and have significantly improved creep properties when compared to Hastelloy®N. The purpose of the CRADA project was for ORNL to collaborate with Haynes International- a materials producer, MetalTek International- a foundry, and Kairos Power – an advanced reactor developer – to scale-up selected alloys, evaluate their properties, and identify one solid solution strengthened alloy that can meet the property requirements for the reactor being developed by Kairos Power and other similar liquid fluoride-salt cooled reactors. As part of the project, eight alloys were down-selected and fabricated in larger industrial scale heats by Haynes International. Resistance to molten salt was evaluated in flowing FLiNaK and FLiBe by Kairos Power using their Rotating Cage Loop (RCL) system. Accounting for iron deposition during these tests, the new alloys displayed very low net mass change showing excellent corrosion performance in molten salt. Creep properties evaluated at ORNL were found to be better than that of Hastelloy®N and 316 stainless steel. Long-term stabilities of the alloys evaluated by Haynes International showed that these alloys have excellent thermal stability in the temperature range 704.4-815.6°C, with the change in strength and ductility being less than 10-15% after a 4000-hour exposure at 815.6°C. Autogenously Gas Tungsten Arc Welding (GTAW) welded samples showed less than 10% change in yield strength / ultimate tensile strength / total elongation compared to the basemetal, indicating that the alloys have excellent weldability. Three parts were successfully investment-cast using one alloy with very little voiding showing feasibility of fabricating parts using the casting process. This project enabled extensive interaction between the material producer Haynes International, casting supplier MetalTek, and reactor developer Kairos Power. This facilitated testing of materials and components produced using the newly developed alloys by the end-user. This allowed the generation of critical dataset required for down-selection of a few promising alloys for further development. This data is also currently being shared with other reactor designers for them to evaluate the suitability of this alloy for their reactor design. The availability of this alloy will ultimately enable the design and development and deployment of MSRs with increased temperature of operation and thus, improved efficiencies.

36 MATERIALS SCIENCE

Corrosion-Resistant Non-Carbon Electrocatalyst Supports for PEFCS

Insufficient durability of commercial catalysts is a persistent issue for PEFC applications.1 Herein, Pt on Nb-doped-TiO 2 is reported as a highly durable electrocatalyst on which the direct 4-electron reduction of oxygen to water is more facile compared to Pt/C. All performance metrics are reported comparing Pt/Nb-TiO2 with a 15% Pt loading, against a commercial Pt/C catalyst (46.5% Pt loading, Tanaka, K. K.). Nb-doped-TiO 2 with high surface area and high electronic conductivity was synthesized using the supercritical fluid method. Initially, the durability of the catalyst was characterized using accelerated stability tests (ASTs) involving 10,000 high potential cycles (DOE/FCCJ protocol) and the Pt/Nb-TiO 2 was found to retain 78% of its initial electrochemically active surface area (ECSA) compared to the 57.6 % retained by Pt/C. These observations were in excellent agreement with previous reports that the Pt particle size of Pt/C grew from 2nm to 8nm during the AST protocol along with severe corrosion and amorphization of the carbon surface.2, 3 TEM and XPS studies of the Pt-Nb-doped-TiO 2 catalyst showed that the Pt particle size grew from 3nm to 6nm and the Nb(IV) and Ti(III) in the support were oxidized to Nb(V) and Ti(IV) after the durability test. Thus, the improvement in Pt/Nb-TiO 2 ECSA retention was attributed to the lower extent of particle growth and lack of oxidative support loss upon oxidation as compared to Pt/C. The oxygen reduction reaction (ORR) performance was characterized by linear polarization using a rotating disk electrode (RDE). The electrochemical surface areas of Pt/Nb-TiO 2 and Pt/C were found to be 48m2·g -1 and 83m2·g -1 respectively, and the mass activity for the ORR at 0.9V vs. RHE were found to be 150 mA·mg-1Pt and 124 mA·mg-1Pt respectively. The improved mass activity on Pt/Nb-TiO 2 was attributed to strong metal support interaction (SMSI) between the Nb-TiO 2 support and the Pt catalyst based on the 625 meV decrease in the binding energy of the Pt4f x-ray photo-electron spectroscopy (XPS) peaks of Pt/Nb-TiO 2 compared to Pt/C. To quantify the impact of the SMSI, a kinetic model was applied to calculate the elementary reaction rate constants for the various steps of the ORR on both catalysts. The reaction rate constant (k1) for the direct 4-electron transfer pathway to produce H 2 O was significantly larger in Pt/Nb-TiO 2 as compared to Pt/C. Thus, the reduction in the electron binding energy as observed in the XPS was found to aid the facile filling of the higher energy 2p orbitals of O 2 thereby leading to improved 4-electron transfer kinetics and improved overall activity.

08 HYDROGEN

Effective Corrosion-Resistant Single-Atom Alloy Catalyst on HfO 2 -Passivated BiVO 4 Photoanode for Durable (≈800 h) Solar Water Oxidation

Green hydrogen (H 2 ) production from solar water splitting necessitates photoelectrodes with superior photoelectrochemical (PEC) activity and durability. However, surface defects and photocorrosion instability—especially at high potentials—limit PEC performance and stability. Herein, the prototypical bismuth vanadate (BiVO 4 ) photoanode is used to demonstrate a holistic approach to improve photocurrent density and long-term stability. In this approach, high surface-area nanostructuring of BiVO 4 is combined with barium (Ba) doping with semi-crystalline hafnium oxide (HfO 2 ) surface passivation and single-atom nickel platinum (NiPt) catalysts. The introduction of Ba 2+ ions into BiVO 4 increases the concentration of conductive V 4+ ions or the ratio of V 4+ ions to oxygen vacancies, avoiding V 5+ dissolution during water oxidation. The semi-crystalline HfO 2 , which serves as a passivation layer, prevents BiVO 4 photocorrosion by suppressing harmful chemical reactions when holes are transferred to the electrolyte. The synergistic use of isolated single-atom and Ni-Pt coordination improves charge transfer at the photoanode/electrolyte interface, leading to enhanced PEC kinetics and stability. As a result, a photoelectrode is demonstrated with ≈6.5 mA cm -2 at 1.23 V versus a reversible hydrogen electrode (RHE) and continuous operation for 800 h with a negligible degradation rate. This work provides a promising approach to improve photoanodes for PEC H 2 production.

08 HYDROGEN

Corrosion resistant hot melt adhesive to bind metals

Hot melt adhesives (HMAs) play an important role in many industries, and their demand is expected to grow. HMAs don't require any solvents, and their application results in the formation of strong bonds with the substrate upon cooling within seconds. These properties differentiate them from liquid glues and make them preferable for practical application. Currently, commercial HMAs are used in bonding lightweight materials such as paper, polymers, and cartons, and have limited usage in areas necessitating the bonding of heavier objects like metals. Here, in this study, we report a design and testing of versatile platform comprising an ion-coordinating polymer and ionic fillers for performance optimization and understanding of structure–property relationships, enabling the rational design of HMAs with improved adhesion to metal surfaces. All-atom Molecular dynamics (MD) simulations and various characterization methods are used to elucidate the adhesion mechanism in model composite system containing polyethylene oxide mixed with chemically diverse salt particles. The maximum adhesion strength is found in composites with Al(OH) 3 and FeCl 3 fillers. Interestingly, the presence of Al(OH) 3 also provides a multifunctional anticorrosion property as measured electrochemically using the Tafel method. The discovered path to formulations with improved adhesion to metal surfaces constitutes an important step toward advancing HMAs for use in the structural and semi-structural metal work domain.

Adhesive and cohesive forces

Rolling-element fatigue life of AMS 5749 corrosion resistant, high temperature bearing steel

The rolling element fatigue lives of AMS 5749 and AISI M-50 were compared in tests run in the five ball fatigue tester and the rolling contact fatigue tester. The effects of double vacuum melting and retained austenite on the life of AMS 5749 were determined in five ball fatigue tests. The double vacuum melting process consisted of induction vacuum melting followed by vacuum arc remelting (VIM-VAR). In the five ball tests, VIM-VAR AMS 5749 gave lives at least six times that of VIM-VAR AISI M-50. Similar tests in the rolling contact fatigue tester showed no significant difference in the lives of the two materials. The rolling element fatigue life of VIM-VAR AMS 5749 was at least 14 times that of vacuum induction melted AMS 5749. A trend toward increased rolling element fatigue life with decreased retained austenite is apparent, but the confidence that all experimental differences are significant is not great.

Parker, R. J.

Study of etchants for corrosion-resistant metals, space shuttle external tank

Acceptable etchant concentrations and application and removal procedures for etching austenitic stainless steel, nickel base alloys, and titanium alloys (annealed) employed on the external tank were formulated. The etchant solutions were to be capable of removing a minimum of 0.4 mils of surface material in less than one hour.

Simmons, J. R.

Thermal barrier coatings for thermal insulation and corrosion resistance in industrial gas turbine engines

Four thermal barrier coatings were subjected to a 500-hour gas turbine engine test. The coatings were two yttria stabilized zirconias, calcium ortho silicate and calcium meta titanate. The calcium silicate coating exhibited significant spalling. Yttria stabilized zirconia and calcium titanate coatings showed little degradation except in blade leading edge areas. Post-test examination showed variations in the coating due to manual application techniques. Improved process control is required if engineering quality coatings are to be developed. The results indicate that some leading edge loss of the coating can be expected near the tip.

Vogan, J. W.

Acid Solutions for Etching Corrosion-Resistant Metals

New study characterized solutions for etching austenitic stainless steels, nickel-base alloys, and titanium alloys (annealed). Solutions recommended for use remove at least 0.4 mil of metal from surface in less than an hour. Solutions do not cause intergranular attack on metals for which they are effective, when used under specified conditions.

Simmons, J. R.

Coated Aluminized Film Resists Corrosion

Commercially available corrosion-protection coating allows less costly metals - aluminum in particular used in heat-reflecting films for thermal barriers. Previously, such films had to incorporate gold as reflective layer to withstand humidity, moisture, and salt spray without corroding. This protective coating prevents corrosion of metalized films during evironmental exposure yet remains flexible, thermally stable and clear.

Rockoff, H. J.

Heated Aluminum Tanks Resist Corrosion

Simple expedient of heating foam-insulated aluminum alloy tanks prevents corrosion by salt-laden moisture. Relatively-small temperature difference between such tank and surrounding air will ensure life of tank is extended by many years.

Johnson, L. E.

Corrosion resistant coating

A method of coating a substrate with an amorphous metal is described. A solid piece of the metal is bombarded with ions of an inert gas in the presence of a magnetic field to provide a vapor of the metal which is deposited on the substrate at a sufficiently low gas pressure so that there is formed on the substrate a thin, uniformly thick, essentially pinhole-free film of the metal.

Khanna, S. K.

A comparison of corrosion-resistant steel (18 percent chromium - 8 percent nickel) and aluminum alloy (24st)

In the selection of materials for aircraft application, it is not enough to make the selection on a strength-weight basis alone. A strength-weight comparison is significant but other factors must be considered, for while a material with a high ratio of strength to weight may be perfectly satisfactory for one use, it may be totally unfitted for another. It is essential, among other things, that the probable nature, magnitude, and direction of the principal stresses be given special consideration. The following analysis has therefore been made with this in mind. An attempt has been made to cover insofar as possible the major, but not all the points, that a designer would consider in the use of "18-8", as it is commonly referred to, and 24ST aluminum alloy, as applied to aircraft. 24ST was selected for this comparison as it has practically replaced 17ST for aircraft construction and it appears to have the best combination of properties of the alloys now available for this purpose. The cost of fabrication has not been considered.

Sullivan, J E