Accelerated corrosion testing of cold spray coatings on 304L in chloride environments

Cold spray is an advanced metal manufacturing technique applied across many fields for a wide range of functions. Low heat input and compressive stresses induced into the substrate by the cold spray process makes it a promising choice for protective corrosion resistant coatings. One potential application for cold spray is as a protective coating against corrosion for spent nuclear fuel (SNF) interim dry storage canisters. As these canisters are currently stored at interim storage locations longer than originally intended, chloride induced stress corrosion cracking has been identified as a high priority knowledge gap, specifically with respect to prolonging or extending canister lifetimes ( Teague et al., 2019 ). The high deployability of cold spray, for which nozzles have been developed for application in constrained spaces, in conjunction with beneficial properties inherent to cold spray makes this a good candidate for a corrosion protection coating on SNF canisters. This work explores a pathway to rapidly down-select cold spray coatings for canisters by focusing on the corrosion properties. Specifically, this study examines the corrosion protection abilities of nickel and nickel-based alloy cold spray coatings on 304 L stainless steel in chloride rich environments through electrochemical scans and ferric chloride pitting tests (ASTM G48 Method A). It was shown that the porosity of the coating, the processing gas, material selection, and deformation in the substrate all impact the corrosion behavior of cold spray coatings and are areas where optimization could reduce potential materials degradation, enabling enhanced coatings development.

Karasz, Erin K.↗

Corrosion testing needs and considerations for additively manufactured materials in nuclear reactors

Additive manufacturing (AM) technologies have developed rapidly in recent years, creating new opportunities and challenges for the nuclear industry; however, adoption requires that their corrosion performance be evaluated. Here, we discuss known reactor-specific corrosion issues for multiple reactor types and engineering concerns such as regulations and standards. A review of corrosion studies conducted on select AM alloys informs a discussion on key bulk and surface factors likely to impact corrosion behaviors. Recommendations to assess corrosion performance for AM materials are provided, including management of the unique nature of as-built AM surfaces and the inherent process variability that occurs for AM components.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

A methodology for corrosion testing ODS steels in liquid tin under reactor conditions in HFIR

Liquid metal–based divertor concepts have promising attributes for application in fusion reactors. Liquid tin is being considered as one of those liquid metals due to its excellent thermophysical properties. However, tin is extremely corrosive to steels at elevated temperatures, and the coupled effects of corrosion with neutron irradiation for application in fusion reactors have not been quantified. Researchers at Oak Ridge National Laboratory (ORNL) have designed and irradiated a series of capsules in the High Flux Isotope Reactor (HFIR) to help address gaps in the literature with respect to coupled corrosion and neutron irradiation effects. The capsules are filled with solid tin designed to melt due to the gamma heating in HFIR and allow interaction with the specimens. The capsules contain a SiC thermometer for post-irradiation temperature verification. Five capsules were irradiated in HFIR for 10.5 days, accumulating 0.93 dpa in the FeCrAl specimens. Post-irradiation temperature verification was performed on the SiC thermometers, and temperatures were observed to be higher than what was expected from thermal models. An explanation for the model underprediction is given herein. In conclusion, the capsules described within this article are the first to irradiate liquid metal within the HFIR flux trap and demonstrated the safety basis for continued liquid coolant studies in HFIR.

FeCrAl↗

Electrochemical, Polarization, and Crevice Corrosion Testing of Nitinol 60, A Supplement to the ECLSS Sustaining Materials Compatibility Study

In earlier trials, electrochemical test results were presented for six noble metals evaluated in test solutions representative of waste liquids processed in the Environmental Control and Life Support System (ECLSS) aboard the International Space Station (ISS). Subsequently, a seventh metal, Nitinol 60, was added for evaluation and subjected to the same test routines, data analysis, and theoretical methodologies. The previous six test metals included three titanium grades, (commercially pure, 6Al-4V alloy and 6Al-4V low interstitial alloy), two nickel-chromium alloys (Inconel(RegisteredTrademark) 625 and Hastelloy(RegisteredTrademark) C276), and one high-tier stainless steel (Cronidur(RegisteredTrademark) 30). The three titanium alloys gave the best results of all the metals, indicating superior corrosive nobility and galvanic protection properties. For this current effort, the results have clearly shown that Nitinol 60 is almost as noble as titanium, being very corrosion-resistant and galvanically compatible with the other six metals electrochemically and during long-term exposure. is also quite noble as it is very corrosion resistant and galvanically compatible with the other six metals from both an electrochemical perspective and long-term crevice corrosion scenario. This was clearly demonstrated utilizing the same techniques for linear, Tafel and cyclic polarization, and galvanic coupling of the metal candidate as was done for the previous study. The high nobility and low corrosion susceptibility for Nitinol 60 appear to be intermediate to the nickel/chromium alloys and the titanium metals with indications that are more reflective of the titanium metals in terms of general corrosion and pitting behavior.

Lee, R. E.↗

Thermal barrier coatings: Burner rig hot corrosion test results

A Mach 0.3 burner rig test program was conducted to examine the sensitivity of thermal barrier coatings to Na and V contaminated combustion gases simulating potential utility gas turbine environments. Coating life of the standard ZrO2-12Y2O3/Ni-16.2Cr-5.6Al-0.6Y NASA thermal barrier coating system which was developed for aircraft gas turbines was significantly reduced in such environments. Two thermal barrier coating systems, Ca2SiO4/Ni-16.2Cr-5.6Al-0.6Y and ZrO2-8Y2O3/Ni-16.4Cr-5.1Al-0.15Y and a less insulative cermet coating system, 50 volume percent MgO-50 volume percent Ni-19.6Cr-17.1Al-0.97Y/Ni-16.2Cr-5.6Al-0.6Y, were identified as having much improved corrosion resistance compared to the standard coating.

Hodge, P. E.↗

Thermal barrier coatings - Burner rig hot corrosion test results

A Mach 0.3 burner rig test program was conducted to examine the sensitivity of thermal barrier coatings to Na- and V-contaminated combustion gases simulating potential utility gas turbine environments. Coating life of the standard ZrO2-12Y2O3/Ni-16.2Cr-5.6Al-0.6Y (composition in wt %) NASA thermal barrier coating system which was developed for aircraft gas turbines was significantly reduced in such environments. Two thermal barrier coating systems, Ca2SiO4/Ni-16.2Cr-5.6Al-0.6Y and ZrO2-8Y2O3/Ni-16.4Cr-5.1Al-0.15Y and a less insulative cermet coating system, 50 vol % MgO-50 vol % Ni-19.6Cr-17.1Al-0.97Y/Ni-16.2Cr-5.6Al-0.6Y, were identified as having much improved corrosion resistance compared to the standard coating.

Hodge, P. E.↗

Corrosion Testing Trade Study on Testing Methods in Molten Salts

In assessing molten salt compatibility with structural materials, static testing is often reported because it is easy to conduct. However, in order to assess mass transfer, where material dissolves in the salt in the hot section and may precipitate out of the liquid in colder regions, a flowing salt experiment in a temperature gradient is needed. While a forced convection or pumped loop produces prototypic flowing conditions, it also is a multi-million dollar investment. Among the less expensive dynamic testing options, the thermal convection loop (TCL) was favored during the 1960’s development of molten salt reactor technology. Because the workforce and core facilities are currently available to conduct TCL experiments, it is the least expensive strategy to evaluate candidate structural alloys in flowing molten salt conditions.

36 MATERIALS SCIENCE↗

Static Corrosion Summary: Static Corrosion Testing, Haynes 230 Recession Rate, Chloride Salts

In this project, the best material and processes that we have available now are used build a pump for validation testing and to be able to provide a quotation for a pump for the Gen3 CSP Phase 3 test facility. Enough high temperature and aged material data is collected to be able to safely design a pump with a high level of confidence of good performance. Manufacturing processes for the nano-composite material including spray coating and joining methods are investigated. These processes enable application of this novel material to pump components.