SEARCH · Search NASA
Results for “COULOMB SCATTERING”
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Radiation of an electric charge in the field of a magnetic monopole
We consider the radiation of photons from quarks scattering on color-magnetic monopoles in the quark-gluon plasma. We consider a temperature regime T > or approx. 2T{sub c}, where monopoles can be considered as static, rare objects embedded into matter consisting mostly of the usual 'electric' quasiparticles, quarks and gluons. The calculation is performed in the classical, nonrelativistic approximation and results are compared to photon emission from Coulomb scattering of quarks, known to provide a significant contribution to the photon emission rates from quark-gluon plasma. The present study is a first step towards understanding whether this scattering process can give a sizeable contribution to dilepton production in heavy-ion collisions. Our results are encouraging: by comparing the magnitudes of the photon emission rate for the two processes, we find a dominance in the case of quark-monopole scattering. Our results display strong sensitivity to finite densities of quarks and monopoles.
Physics considerations for laser-plasma linear colliders
Physics considerations for a next-generation linear collider based on laser-plasma accelerators are discussed. The ultra-high accelerating gradient of a laser-plasma accelerator and short laser coupling distance between accelerator stages allows for a compact linac. Two regimes of laser-plasma acceleration are discussed. The highly nonlinear regime has the advantages of higher accelerating fields and uniform focusing forces, whereas the quasi-linear regime has the advantage of symmetric accelerating properties for electrons and positrons. Scaling of various accelerator and collider parameters with respect to plasma density and laser wavelength are derived. Reduction of beamstrahlung effects implies the use of ultra-short bunches of moderate charge. The total linac length scales inversely with the square root of the plasma density, whereas the total power scales proportional to the square root of the density. A 1 TeV center-of-mass collider based on stages using a plasma density of 10{sup 17} cm{sup -3} requires tens of J of laser energy per stage (using 1 {micro}m wavelength lasers) with tens of kHz repetition rate. Coulomb scattering and synchrotron radiation are examined and found not to significantly degrade beam quality. A photon collider based on laser-plasma accelerated beams is also considered. The requirements for the scattering laser energy are comparable to those of a single laser-plasma accelerator stage.
The Cold and Hot Electron Populations, Temperatures and Their Transports in the Edge Plasma of the ORNL CAPRICE ECR Ion Source
The edge plasma of the ORNL CAPRICE ECR ion source is studied by directly measuring, with electrical probes, its local plasma parameters such as plasma density, temperature and electron energy distribution characteristics at different rf power levels, at various pressures, at various axial magnetic field strengths and different distances from the resonant zone. It is found that the edge plasma can be approximated to be bi-Maxwellian, whose characteristics become more pronounced at the more distant positions from the ECR zone, at lower source pressures and at increased magnetic field strengths. These trends are consistently explained in terms of long-range electron-electron and electron-ion Coulomb scattering collisions that occur during the transport of hot electrons from the ECR plasma to the probe and their frequency dependence on electron temperature and density.
Comparison of Carbon and Hi-Z Primary Collimators for the LHC Phase II Collimation System
A current issue with the LHC collimation system is single-diffractive, off-energy protons from the primary collimators that pass completely through the secondary collimation system and are absorbed immediately downbeam in the cold magnets of the dispersion suppressor section. Simulations suggest that the high impact rate could result in quenching of these magnets. We have studied replacing the 60 cm primary graphite collimators, which remove halo mainly by inelastic strong interactions, with 5.25 mm tungsten, which remove halo mainly by multiple coulomb scattering and thereby reduce the rate of single-diffractive interactions that cause losses in the dispersion suppressor.
Prediction of Net Energy Gain in Deuterium-Beam Interactions with an Inertially Confined Plasma
It is shown that deuteron beams incident on compressed, tritium-based plasma targets can undergo beam-fusion reactions at a rate greater than Coulomb scattering for a wide range of beam energies and target temperatures. As a result, energy gains of about 5 are possible. The analysis is carried out by treating the beam ions, target ions, and the electrons as separate fluids. Essential to the attainment of high gain is the inclusion of the contribution to the fusion yield from deuterons that gain scattered energy at the expense of directed energy. The results are confirmed by Monte Carlo simulations equivalent to a Fokker-Planck treatment.
Touschek Lifetime Calculations for NSLS-II
The Touschek effect limits the lifetime for NSLS-II. The basic mechanism is Coulomb scattering resulting in a longitudinal momentum outside the momentum aperture. The momentum aperture results from a combination of the initial betatron oscillations after the scatter and the non-linear properties determining the resultant stability. We find that higher order multipole errors may reduce the momentum aperture, particularly for scattered particles with energy loss. The resultant drop in Touschek lifetime is minimized, however, due to less scattering in the dispersive regions. We describe these mechanisms, and present calculations for NSLS-II using a realistic lattice model including damping wigglers and engineering tolerances.
Quantum calculations of the carrier mobility: Methodology, Matthiessen's rule, and comparison with semi-classical approaches
We discuss carrier mobilities in the quantum Non-Equilibrium Green's Functions (NEGF) framework. We introduce a method for the extraction of the mobility that is free from contact resistance contamination and with minimal needs for ensemble averages. We focus on silicon thin films as an illustration, although the method can be applied to various materials such as semiconductor nanowires or carbon nanostructures. We then introduce a new paradigm for the definition of the partial mobility μ{sub M} associated with a given elastic scattering mechanism “M,” taking phonons (PH) as a reference (μ{sub M}{sup −1}=μ{sub PH+M}{sup −1}−μ{sub PH}{sup −1}). We argue that this definition makes better sense in a quantum transport framework as it is free from long range interference effects that can appear in purely ballistic calculations. As a matter of fact, these mobilities satisfy Matthiessen's rule for three mechanisms [e.g., surface roughness (SR), remote Coulomb scattering (RCS) and phonons] much better than the usual, single mechanism calculations. We also discuss the problems raised by the long range spatial correlations in the RCS disorder. Finally, we compare semi-classical Kubo-Greenwood (KG) and quantum NEGF calculations. We show that KG and NEGF are in reasonable agreement for phonon and RCS, yet not for SR. We discuss the reasons for these discrepancies.
Mobility enhancement in crystalline In-Ga-Zn-oxide with In-rich compositions
The electron mobility of In-Ga-Zn-oxide (IGZO) is known to be enhanced by higher In content. We theoretically investigated the mobility-enhancement mechanism by proposing an In-Ga-Zn-disorder scattering model for an In-rich crystalline IGZO (In{sub 1+x}Ga{sub 1−x}O{sub 3}(ZnO){sub m} (0 < x < 1, m > 0)) thin film. The obtained theoretical mobility was found to be in agreement with experimental Hall mobility for a crystalline In{sub 1.5}Ga{sub 0.5}O{sub 3}(ZnO) (or In{sub 3}GaZn{sub 2}O{sub 8}) thin film. The mechanism specific to In-rich crystalline IGZO thin films is based on three types of Coulomb scattering potentials that originate from effective valence differences. In this study, the In-Ga-Zn-disorder scattering model indicates that the effective valence of the In{sup 3+} ions in In-rich crystalline IGZO thin films significantly affects their electron mobility.
Mobility of the Two-Dimensional Electron Gas in DA-pHEMT Heterostructures with Various δ–n-Layer Profile Widths
The effect of the silicon-atom distribution profile in donor δ-layers of AlGaAs/InGaAs/AlGaAs heterostructures with donor–acceptor doping on the mobility of the two-dimensional electron gas is studied. The parameters of the δ-layer profiles are determined using the normal approximation of the spatial distributions of silicon atoms, measured by secondary-ion mass spectroscopy. It is shown that the standard deviation σ of the δ-layer profile can be reduced from 3.4 to 2.5 nm by the proper selection of growth conditions. Measurements of the magnetic-field dependences of the Hall effect and conductivity show that such a decrease in σ allowed an increase in the mobility of the two-dimensional electron gas in heterostructures by 4000 cm{sup 2}/(V s) at 77 K and 600 cm{sup 2}/(V s) at 300 K. The mobility calculation taking into account filling of the first two size-quantization subbands shows that an increase in the mobility is well explained by a reduction in the Coulomb scattering at ionized donors due to an increase in the effective thickness of the spacer layer with decreasing σ of the δ-layer profile.
Storage Ring Section for a Polarized Gas Target with High Angular Acceptance
In the framework of the FAIR project, the PAX collaboration has suggested new experiments using polarized protons and antiprotons. In order to provide polarized antiprotons, the polarization buildup by spin-dependent attenuation due to nuclear interaction (spin-filtering) must be studied. The goal of these investigations is to understand the physics of the spin-filtering process with stored protons at COSY, and to shed light on the role of polarized electrons for the polarization buildup. Later on, the spin-dependence of the proton-antiproton interaction will be investigated at the Antiproton Decelerator ring (AD) of CERN. In order to carry out these investigations, a storage ring section has to be developed which minimizes the spin-independent losses due to single Coulomb scattering.
Hyperdiffusion of dust particles in a turbulent tokamak plasma
In this work, the effect of plasma turbulence on the trajectories of dust particles is investigated for the first time. The dynamics of dust particles is computed using the ad hoc developed Dust Injection Simulator code, using a 3D turbulent plasma background computed with the TOKAM3X code. As a result, the evolution of the particle trajectories is governed by the ion drag force, and the shape of the trajectory is set by the Stokes number St∝a d /n 0 , with a d the dust radius and n 0 the density at the separatrix. The plasma turbulence is observed to scatter the dust particles, exhibiting a hyperdiffusive regime in all cases. The amplitude of the turbulent spread of the trajectories Δr 2 is shown to depend on the ratio Ku/St, with Ku∝u rms the Kubo number and urms the fluctuation level of the plasma flow. These results are compared with a simple analytical model, predicting Δr 2 ∝(Ku/St) 2 t 3 , or Δr 2 ∝(u rms n 0 /a d ) 2 t 3 . As the dust is heated by the plasma fluxes, thermionic emission sets the dust charge, originally negative, to slightly positive values. This results in a substantial reduction of the ion drag force through the suppression of its Coulomb scattering component. The dust grain inertia is then no longer negligible and drives the transition from a hyperdiffusive regime toward a ballistic one.
SU-E-J-158: Experimental Investigation of Proton Radiography Based On Time-Resolved Dose Measurements
Purpose: To use proton radiography for i) in-vivo range verification of the brain fields of medulloblastoma patients in order to reduce the exit dose to the cranial skin and thus the risk of permanent alopecia; ii) for performing patient specific optimization of the calibration from CT-Hounsfield units to proton relative stopping power in order to minimize uncertainties of proton rang Methods: We developed and tested a prototype proton radiography system based on a single-plane scintillation screen coupled with a fast CCD camera (1ms sampling rate, 0.29x0.29 mm{sup 2} pixel size, 30×30 cm{sup 2} field of view). The method is based on the principle that, for passively scattered beams, the radiological depth of any point in the plateau of a spread-out Bragg-Peak (SOBP) can be inferred from the time-pattern of the dose rate measurements. We performed detector characterization measurements using complex-shape homogeneous phantoms and an Alderson phanto Results: Detector characterization tests confirmed the robustness of the technique. The results of the phantom measurements are encouraging in terms of achievable accuracy of the water equivalent thickness. A technique to minimize the degradation of spatial resolution due to multiple Coulomb scattering is discussed. Our novel radiographic technique is rapid (100 ms) and simultaneous over the whole field. The dose required to produce one radiograph, with the current settings, is ∼3 cG Conclusion: The results obtained with this simple and innovative radiography method are promising and motivate further development of technique. The system requires only a single-plane 2D dosimeter and it uses the clinical beam for a fraction of second with low dose to the patient.
TH-C-19A-01: Analytic Design Method to Make a 2D Planar, Segmented Ion Chamber Water-Equivalent for Proton Dose Measurements
Purpose: Quality Assurance (QA) measurements of proton therapy fields must accurately measure steep longitudinal dose gradients as well as characterize the dose distribution laterally. Currently, available devices for two-dimensional field measurements perturb the dose distribution such that routine QA measurements performed at multiple depths require multiple field deliveries and are time consuming. Methods: A design procedure for a two-dimensional detector array is introduced whereby the proton energy loss and scatter are adjusted so that the downstream dose distribution is maintained to be equivalent to that which would occur in uniform water. Starting with the design for an existing, functional two-dimensional segmented ion chamber prototype, a compensating material is introduced downstream of the detector to simultaneously equate the energy loss and lateral scatter in the detector assembly to the values in water. An analytic formalism and procedure is demonstrated to calculate the properties of the compensating material in the general case of multiple layers of arbitrary material. The resulting design is validated with Monte Carlo simulations. Results: With respect to the specific prototype design considered, the results indicate that a graphite compensating layer of the proper dimensions can yield proton beam range perturbation less than 0.1mm and beam sigma perturbation less than 2% across the energy range of therapeutic proton beams. Conclusion: We have shown that, for a 2D gas-filled detector array, a graphite-compensating layer can balance the energy loss and multiple Coulomb scattering relative to uniform water. We have demonstrated an analytic formalism and procedure to determine a compensating material in the general case of multiple layers of arbitrary material. This work was supported by the US Army Medical Research and Materiel Command under Contract Agreement No. DAMD17-W81XWH-04-2-0022. Opinions, interpretations, conclusions and recommendations are those of the author and are not necessarily endorsed by the US Army.
SU-F-I-54: Spatial Resolution Studies in Proton CT Using a Phase-II Prototype Head Scanner
Purpose: To characterize the modulation transfer function (MTF) of the pre-clinical (phase II) head scanner developed for proton computed tomography (pCT) by the pCT collaboration. To evaluate the spatial resolution achievable by this system. Methods: Our phase II proton CT scanner prototype consists of two silicon telescopes that track individual protons upstream and downstream from a phantom, and a 5-stage scintillation detector that measures a combination of the residual energy and range of the proton. Residual energy is converted to water equivalent path length (WEPL) of the protons in the scanned object. The set of WEPL values and associated paths of protons passing through the object over a 360° angular scan is processed by an iterative parallelizable reconstruction algorithm that runs on GP-GPU hardware. A custom edge phantom composed of water-equivalent polymer and tissue-equivalent material inserts was constructed. The phantom was first simulated in Geant4 and then built to perform experimental beam tests with 200 MeV protons at the Northwestern Medicine Chicago Proton Center. The oversampling method was used to construct radial and azimuthal edge spread functions and modulation transfer functions. The spatial resolution was defined by the 10% point of the modulation transfer function in units of lp/cm. Results: The spatial resolution of the image was found to be strongly correlated with the radial position of the insert but independent of the relative stopping power of the insert. The spatial resolution varies between roughly 4 and 6 lp/cm in both the the radial and azimuthal directions depending on the radial displacement of the edge. Conclusion: The amount of image degradation due to our detector system is small compared with the effects of multiple Coulomb scattering, pixelation of the image and the reconstruction algorithm. Improvements in reconstruction will be made in order to achieve the theoretical limits of spatial resolution.
Quasi-Classical Model of the Static Electrical Conductivity of Heavily Doped Degenerate Semiconductors at Low Temperatures
Germanium, silicon, gallium arsenide, and indium antimonide n-type crystals on the metal side of the insulator–metal transition (Mott transition) are considered. In the quasi-classical approximation, the static (direct current) electrical conductivity and the drift mobility of electrons of the c band, and electrostatic fluctuations of their potential energy and the mobility edge are calculated. It is considered that a single event of the elastic Coulomb scattering of a mobile electron occurs only in a spherical region of the crystal matrix with an impurity ion at the center. The results of calculations using the proposed formulas without using fitting parameters are numerically consistent with experimental data in a wide range of concentrations of hydrogenlike donors at their weak and moderate compensation by acceptors.
Proton minibeam radiation therapy: Experimental dosimetry evaluation
Purpose: Proton minibeam radiation therapy (pMBRT) is a new radiotherapy (RT) approach that allies the inherent physical advantages of protons with the normal tissue preservation observed when irradiated with submillimetric spatially fractionated beams. This dosimetry work aims at demonstrating the feasibility of the technical implementation of pMBRT. This has been performed at the Institut Curie - Proton Therapy Center in Orsay. Methods: Proton minibeams (400 and 700 μm-width) were generated by means of a brass multislit collimator. Center-to-center distances between consecutive beams of 3200 and 3500 μm, respectively, were employed. The (passive scattered) beam energy was 100 MeV corresponding to a range of 7.7 cm water equivalent. Absolute dosimetry was performed with a thimble ionization chamber (IBA CC13) in a water tank. Relative dosimetry was carried out irradiating radiochromic films interspersed in a IBA RW3 slab phantom. Depth dose curves and lateral profiles at different depths were evaluated. Peak-to-valley dose ratios (PVDR), beam widths, and output factors were also assessed as a function of depth. Results: A pattern of peaks and valleys was maintained in the transverse direction with PVDR values decreasing as a function of depth until 6.7 cm. From that depth, the transverse dose profiles became homogeneous due to multiple Coulomb scattering. Peak-to-valley dose ratio values extended from 8.2 ± 0.5 at the phantom surface to 1.08 ± 0.06 at the Bragg peak. This was the first time that dosimetry in such small proton field sizes was performed. Despite the challenge, a complete set of dosimetric data needed to guide the first biological experiments was achieved. Conclusions: pMBRT is a novel strategy in order to reduce the side effects of RT. This works provides the experimental proof of concept of this new RT method: clinical proton beams might allow depositing a (high) uniform dose in a brain tumor located in the center of the brain (7.5 cm depth, the worst scenario), while a spatial fractionation of the dose is retained in the normal tissues in the beam path, potentially leading to a gain in tissue sparing. This is the first complete experimental implementation of this promising technique. Biological experiments are needed in order to confirm the clinical potential of pMBRT.
Large-scale proton radiography with micrometer spatial resolution using femtosecond petawatt laser system
An image of dragonfly with many details is obtained by the fundamental property of the high-energy proton source on a femtosecond petawatt laser system. Equal imaging of the dragonfly and high spatial resolution on the micrometer scale are simultaneously obtained. The head, wing, leg, tail, and even the internal tissue structures are clearly mapped in detail by the proton beam. Experiments show that image blurring caused by multiple Coulomb scattering can be reduced to a certain extent and the spatial resolution can be increased by attaching the dragonfly to the RCFs, which is consistent with theoretical assumptions.