Search NASA⌕ Search

SEARCH · Search NASA

Results for “COUNTING RATES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

High-resolution imaging X-ray detector

The paper describes an X-ray detector using microchannel plates as a photocathode surface and imaging photoelectron multiplier, and a crossed wire grid as a two-dimensional position-sensitive detector. The position resolution is 10 microns. The crossed wire grid consists of 100-micron-diam wires on 200-micron centers. Position sensing is accomplished by electronic interpolation to 1/20 of the wire spacing. The quantum efficiency of the microchannel plates varies from 29% at 0.28 keV to 5% at 3 keV. This detector will provide second-of-arc X-ray imaging in the focal plane of the 342.9-cm focal length grazing-incidence telescope being prepared for the HEAO-B observatory. By addition of suitable photocathodes, it can be used for single-photon imaging light detection in the UV, visible, and near-IR-ranges. In all cases, it gives a very low dark counting rate, allows timing of individual events to 1 microsec or less, and can handle counting rates up to 10,000 per sec.

Kellogg, E.↗

The MIT/OSO 7 catalog of X-ray sources - Intensities, spectra, and long-term variability

This paper is a summary of the observations of the cosmic X-ray sky performed by the MIT 1-40-keV X-ray detectors on OSO 7 between October 1971 and May 1973. Specifically, mean intensities or upper limits of all third Uhuru or OSO 7 cataloged sources (185 sources) in the 3-10-keV range are computed. For those sources for which a statistically significant (greater than 20) intensity was found in the 3-10-keV band (138 sources), further intensity determinations were made in the 1-15-keV, 1-6-keV, and 15-40-keV energy bands. Graphs and other simple techniques are provided to aid the user in converting the observed counting rates to convenient units and in determining spectral parameters. Long-term light curves (counting rates in one or more energy bands as a function of time) are plotted for 86 of the brighter sources.

Markert, T. H.↗

Spectra of solar proton ground level events using neutron monitor and neutron moderated detector recordings

Recordings on relativistic solar flare protons observed at Sanae, Antarctic, show that the percentage increase in counting rates of the neutron moderated detector (4NMD) is larger than the percentage increase in counting rates of the 3NM64 neutron monitor. These relative increases are described by solar proton differential spectra j sub s(P) = AP(beta). The power beta is determined for each event and the hardnesses of the temporal variations of beta, found for the ground level events (GLE) of 7 May, 1978 and 22 November, 1977.

Stoker, P. H.↗

Interstellar Pickup Hydrogen Observations from the Pioneer 10 and 11 Plasma Analyzers

The Pioneer 10 and 11 Ames plasma analyzers included off-angle integrating counters used for the first exploration of magnetospheric plasmas at Jupiter and Saturn. When summed over multi-day intervals during interplanetary cruise, at times of relatively constant solar wind speed during 1972 to 1977, the resulting count rates show a dependence on acceptance energies of the plasma analyzer deflection plates. The count rates could be produced by energetic charged particles, solar wind protons moving at a large angle to the bulk flow, and interstellar pickup ions. We interpret the more energetic of two peaks that are sometimes observed as the signature of interstellar pickup hydrogen. This peak is located at just below twice the solar wind speed (V(sub SW)), when near 3 AU heliocentric distance, decreasing to just above V(sub SW) as the heliocentric distance increases. Also, in the 8 to 12 AU range of heliocentric distances, we identify the pickup hydrogen signature as a shelf that ends at an edge located below 2V(sub SW). During these observations, the spacecraft longitude relative to the upstream interstellar flow changes roughly from 25 deg, to 155 deg at the larger heliocentric distance. The peak at the smaller heliocentric distances is most consistent with a velocity distribution that is a shell in phase space, with limited thickening as the pickup ions are assimilated into the solar wind flow.

Mihalov, J. D.↗

South Atlantic Anomaly Entry and Exit as Measured by the X-Ray Timing Explorer

The Rossi X-ray Timing Explorer (RXTE) carries instruments that must switch off high voltages (HV) when passing through the South Atlantic Anomaly (SAA). The High Energy X-ray Timing Experiment (HEXTE) contains a particle monitor that detects the increased particle flux associated with the SAA and autonomously reduces its voltage. The Proportional Counter Array (PCA) relies on uplinked predictions of SAA entry/exit times based on ephemeris data provided by the Flight Dynamics Facility. A third instrument, the All-Sky Monitor (ASM) also uses a predicted SAA model to reduce voltage when passing through the SAA. Data collected from the HEXTE particle monitor, as well as other instrument readings near the times of SAA entry/exit offer the potential for refining models of the boundaries of the SAA. The SAA has an increased particle flux which causes high rates of detection in the RXTE instruments designed to observe x-rays. The high counting rates could degrade the PCA if HV is not reduced during SAA passages. On the other hand, PCA downtime can be minimized and the science return can be optimized by having the best possible model of the SAA boundary. Thus, the PCA team planned an extensive effort during in-orbit checkout to utilize both the HEXTE particle monitor data and instrument counting rates to refine the model of the SAA boundary. The times of SAA entry and exit are compared with the definitive epemeris to determine the precise location (latitude and longitude) of the SAA boundary. Over time, the SAA and its perimeter were mapped. The RXTE Science Operations Center is continuously working to feed back the results of this effort into the science scheduling process, improving the SAA model as it affects the RXTE instruments, thus obtaining more accurate estimates of the SAA entry/exit times.

Smith, Evan↗

Low noise and conductively cooled microchannel plates

Microchannel plate (MCP) dynamic range has recently been enhanced for both very low and very high input flux conditions. Improvements in MCP manufacturing technology reported earlier have led to MCPs with substantially reduced radioisotope levels, giving dramatically lower internal background-counting rates. An update is given on the Galileo low noise MCP. Also, new results in increasing the MCP linear counting range for high input flux densities are presented. By bonding the active face of a very low resistance MCP (less than 1 megaohm) to a substrate providing a conductive path for heat transport, the bias current limit (hence, MCP output count rate limit) can be increased up to two orders of magnitude. Normal pulse-counting MCP operation was observed at bias currents of several mA when a curved-channel MCP (80:1) was bonded to a ceramic multianode substrate; the MCP temperature rise above ambient was less than 40 C.

Feller, W. B.↗

Studies of cluster X-ray sources - Size measurements

An examination is conducted of the nine weaker sources in the list of Kellogg et al. (1973) which are well enough observed to be listed in the 3U catalog compiled by Giacconi et al. (1974). The cluster sizes are presented in a table and chi-square plots versus derived core radius and background counting rate are shown in a graph. X-ray luminosities calculated from the 3U catalog counting rates are presented as a function of X-ray size.

Kellogg, E.↗

A photon-counting multichannel spectrometer

A multichannel detector system is described in which the positions of individual photon events in a high-gain image intensifier are decoded in the output of a video detector. The high-gain intensifier consists of a pair of three-stage electrostatic image-tube assemblies each containing three fiber-optically-coupled tubes potted in a rugged package with an internal high-voltage supply. Operation of the electrooptical system is discussed along with the pulse-detection process and the operation of the spectrograph in which the image-tube assembly is mounted. It is noted that the spectrometer detects 1.0 count/sec per A for an object of magnitude 13.0 at the peak of its response in the visual band when no light is lost on the slit, that a 10% coincidence correction is reached at an overall count rate of 860 per sec, and that the response follows an exponential law up to count rates of about 4000 per sec. The measured spectrum of the Seyfert galaxy NGC 5548 is provided as an example of the raw data produced by the instrument on a 1.5 meter telescope.

Shectman, S. A.↗

Variability of X-ray emission from OB stars

The variability in soft X-ray emission of 12 OB stars is studied. Two different methods of analysis, one more suitable for detecting short-term variations, the other aimed at detecting long time-scale variations, are applied to all stars in the sample. The long-term variability analysis shows that Cyg-OB2 8A Zeta Pup and Delta Ori exhibit significant count rate variations between different data sections. Similar variations are marginally detected in 15 Mon; the count rate variations for the other eight stars are consistent with statistical fluctuations. The light curve of Cyg-OB2 8A suggests the existence of two different emission levels. The short-term variability analysis detects marginal variability in Tau Sco with an effective amplitude of about 30 percent and a time scale of about 50 s. The upper limits to the effective short-term variability amplitude for all other sample stars are in the 10-30 percent range.

Collura, A.↗

The results from the X ray bremsstrahlung experiment of Project Trigger

Analysis of the bremsstrahlung X-ray data produced the following conclusions. The counting rate observed before the explosion was an expected normal quiet background. An unexpected increase in the counting rate below 20 keV was observed after the explosion, which may have been an effect of the explosion. A significant 0.13-H2 peak in the power spectral density of the X-ray flux was observed, which is interpreted as evidence for a particle-wave-particle interaction involving a bounce resonance stimulated by the explosion. Dispersed continuation of this interaction may have been responsible for delayed long-term precipitation.

Bering, E. A.↗

ROSAT observations of X-ray-selected active galactic nuclei

We have observed sample of six optically faint, X-ray-selected active galactic nuclei with the Roentgen Satellite (ROSAT) Position Sensitive Proportional Counter (PSPC). These objects represents a sample of soft and hard spectrum sources; all were observed previously with the Einstein X-Ray Observatory. Included in this sample is EO132.8-4111, whose soft X-ray and ultraviolet flux distributions bear a striking resemblance to that of Mrk 841, but whose relative hard X-ray emission is much less than that of Mrk 841. The spectra are all fitted satisfactorily with single power-law models and their spectral indices (with one exception) agree with those estimated from the Einstein Image Propotional Counter (IPC) observations. Tests of short-term variability are carried out, with all sources showing constant count rates over the period of their ROSAT observations. Some sources do, however, show significant changes in count rate when compared to previous Einstein data taken a decade earlier.

Thompson, R. J., Jr.↗

A Catalog of Terrestrial Gamma-Ray Flashes Observed with the Fermi- Gamma-Ray Burst Monitor: The First Sixteen Months of Operation

The Gamma-ray Burst Monitor (GBM) on the Fermi Gamma-ray Space Telescope Observatory (Fermi) has been detecting on the average about one terrestrial gamma-ray flash every four weeks. This catalog presents the basic characteristics of observed TGFs from the beginning of the Fermi-GBM operation in 2008 July until 2009 October. The thick bismuth germanate (BGO) scintillation detectors of the GBM system have observed photon energies from TGFs at energies above 30 MeV. It is found that the TGF pulses are typically shorter than previously reported, and in several cases less than 0.2ms. Extremely high counting rates are encountered ~200kcps or higher per detector during portions of some TGFs. These high rates require considerable corrections (with inherent assumptions) to the observed data in order to derive the true counting rates.

Fishman, Gerald J.↗

Improved Detection System Description and New Method for Accurate Calibration of Micro-Channel Plate Based Instruments and Its Use in the Fast Plasma Investigation on NASA's Magnetospheric MultiScale Mission

The Fast Plasma Investigation (FPI) on NASAs Magnetospheric MultiScale (MMS) mission employs 16 Dual Electron Spectrometers (DESs) and 16 Dual Ion Spectrometers (DISs) with 4 of each type on each of 4 spacecraft to enable fast (30 ms for electrons; 150 ms for ions) and spatially differentiated measurements of the full 3D particle velocity distributions. This approach presents a new and challenging aspect to the calibration and operation of these instruments on ground and in flight. The response uniformity, the reliability of their calibration and the approach to handling any temporal evolution of these calibrated characteristics all assume enhanced importance in this application, where we attempt to understand the meaning of particle distributions within the ion and electron diffusion regions of magnetically reconnecting plasmas. Traditionally, the micro-channel plate (MCP) based detection systems for electrostatic particle spectrometers have been calibrated using the plateau curve technique. In this, a fixed detection threshold is set. The detection system count rate is then measured as a function of MCP voltage to determine the MCP voltage that ensures the count rate has reached a constant value independent of further variation in the MCP voltage. This is achieved when most of the MCP pulse height distribution (PHD) is located at higher values (larger pulses) than the detection system discrimination threshold. This method is adequate in single-channel detection systems and in multi-channel detection systems with very low crosstalk between channels. However, in dense multi-channel systems, it can be inadequate. Furthermore, it fails to fully describe the behavior of the detection system and individually characterize each of its fundamental parameters. To improve this situation, we have developed a detailed phenomenological description of the detection system, its behavior and its signal, crosstalk and noise sources. Based on this, we have devised a new detection system calibration method that enables accurate and repeatable measurement and calibration of MCP gain, MCP efficiency, signal loss due to variation in gain and efficiency, crosstalk from effects both above and below the MCP, noise margin, and stability margin in one single measurement. More precise calibration is highly desirable as the instruments will produce higher quality raw data that will require less post-acquisition data correction using results from in-flight pitch angle distribution measurements and ground calibration measurements. The detection system description and the fundamental concepts of this new calibration method, named threshold scan, will be presented. It will be shown how to derive all the individual detection system parameters and how to choose the optimum detection system operating point. This new method has been successfully applied to achieve a highly accurate calibration of the DESs and DISs of the MMS mission. The practical application of the method will be presented together with the achieved calibration results and their significance. Finally, it will be shown that, with further detailed modeling, this method can be extended for use in flight to achieve and maintain a highly accurate detection system calibration across a large number of instruments during the mission.

detection system↗

Array-scale performance of TES X-ray Calorimeters Suitable for Constellation-X

Having developed a transition-edge-sensor (TES) calorimeter design that enables high spectral resolution in high fill-factor arrays, we now present array-scale results from 32-pixel arrays of identical closely packed TES pixels. Each pixel in such an array contains a Mo/Au bilayer with a transition temperature of 0.1 K and an electroplated Au or Au/Bi xray absorber. The pixels in an array have highly uniform physical characteristics and performance. The arrays are easy to operate due to the range of bias voltages and heatsink temperatures over which solution better than 3 eV at 6 keV can be obtained. Resolution better than 3 eV has also been obtained with 2x8 time-division SQUID multiplexing. We will present the detector characteristics and show spectra acquired through the read-out chain from the multiplexer electronics through the demultiplexer software to real-time signal processing. We are working towards demonstrating this performance over the range of count rates expected in the observing program of the Constellation-X observatory. We mill discuss the impact of increased counting rate on spectral resolution, including the effects of crosstalk and optimal-filtering dead time.

Kilbourne, C. A.↗

MASS CONTENT AND DYNAMICAL STATE OF 3 OPTICALLY SELECTED HIGH-Z CLUSTERS

As part of our analysis of the Chandra and XMM-Newton observations of the high redshift, optically selected cluster ElS0954-2023/22, we have identified Chandra sources in the field and measured their count rate and fluxes. From the 15 ksec Chandra ACIS-S observation, we detected eleven X-ray sources. Their positions and count rates are listed below. Our analysis also shows faint diffuse emission associated with the optically identified cluster. This information was used in a joint analysis of the XMM-Newton observation of the cluster emission to determine the luminosity and temperature of the diffuse cluster gas.

Mushotzky, Richard F.↗

Miniature Focusing Time-of-Flight Mass Spectrometer

An improved miniature time-of-flight mass spectrometer has been developed in a continuing effort to minimize the sizes, weights, power demands, and costs of mass spectrometers for such diverse applications as measurement of concentrations of pollutants in the atmosphere, detecting poisonous gases in mines, and analyzing exhaust gases of automobiles. Advantageous characteristics of this mass spectrometer include the following: It is simple and rugged. Relative to prior mass spectrometers, it is inexpensive to build. There is no need for precise alignment of its components. Its mass range is practically unlimited Relative to prior mass spectrometers, it offers high sensitivity (ability to measure relative concentrations as small as parts per billion). Its resolution is one dalton (one atomic mass unit). An entire mass spectrum is recorded in a single pulse. (In a conventional mass spectrometer, a spectrum is recorded mass by mass.) The data-acquisition process takes only seconds. It is a lightweight, low-power, portable instrument. Although time-of-flight mass spectrometers (TOF-MSs) have been miniaturized previously, their performances have not been completely satisfactory. An inherent adverse effect of miniaturization of a TOF-MS is a loss of resolution caused by reduction of the length of its flight tube. In the present improved TOF-MS, the adverse effect of shortening the flight tube is counteracted by (1) using charged-particle optics to constrain ion trajectories to the flight-tube axis while (2) reducing ion velocities to increase ion flight times. In the present improved TOF-MS, a stream of gas is generated by use of a hypodermic needle. The stream of gas is crossed by an energy-selected, pulsed beam of electrons (see Figure 1). The ions generated by impingement of the electrons on the gas atoms are then focused by three cylindrical electrostatic lenses, which constitute a segmented flight tube. After traveling along the flight tube, the ions enter a charged-particle detector. The output of the detector is fed to a counting circuit to obtain data on the counting rate as a function of time. Inasmuch as time of flight is directly proportional to the ion mass, a plot of the counting rate versus time of flight is equivalent to a mass spectrum (see Figure 2).

Kanik, Isik↗

Self-scanned anode array with a microchannel plate electron multiplier - The SSANACON

A photoelectron counting detector utilizing a 128-element linear self-scanned anode array to collect the output of a dual microchannel plate electron multiplier is described. The operation of the detector, its spatial resolution and detection efficiency, and radiation behavior are discussed. The low-noise detector was developed for the Mariner Jupiter/Saturn mission UV spectrometer, and offers a large dynamic range and count rate of 0.003 per anode-sec. It can measure simultaneously two spatially separated signals differing by more than six orders of magnitude in count rate.

Broadfoot, A. L.↗

Phase space distribution of halo particles and detection of WIMPS

We calculate the velocity distribution of halo particles using realistic models for the density profiles of the Galactic disk, spheroid, and halo components. We get the resulting velocity distribution, which is different from the Maxwellian distribution of isothermal halo. We investigate the consequences concerning the time averaged count rate and the amplitude of the annual modulation in WIMPS detection experiments. Compared to the previous estimate based on the Maxwellian distribution, the time averaged count rate is up to 40 percent larger. On the other hand, the amplitude of the annual modulation is up to a factor of two larger.

Ryu, Dongsu↗