Search NASA⌕ Search

SEARCH · Search NASA

Results for “Calibration methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Application of Indirect Quantification of 133mXe to Calibration of HPGe Detector

The INL Noble Gas Laboratory provides intercomparison samples for the noble gas analysis laboratories as part of the CTBTO PrepCom IMS. Xe-133m is one of the four relevant radionuclides in nuclear explosion monitoring. Without commercially available Xe-133m calibration standards laboratories must create and improve calibration methods. Improvements in calibration methods at the INL NGL benefit the CTBTO PrepCom through better certified values for Xe-133m intercomparison samples. Calibration of High Purity Germanium detectors for Xe-133m quantification is complicated by the coexistence of Xe-133 in samples under analysis. Xe-133 is typically produced in larger quantities, has higher gamma emission probabilities, and its gammas are detected more efficiently than Xe-133m. Xe-133m activity of samples can be indirectly inferred through the 133:133m activity ratio of a batch of material, and the Xe-133 counts in the assay of a small aliquot of the same material. This indirect quantification method can be leveraged to perform detector calibrations for quantification of Xe-133m. Calibrations can be performed by inferring the Xe-133m to certify the sample, and direct counting to determine detector efficiency. A comparison of method results will be shown.

133mXe↗

Improved in situ spring constant calibration for colloidal probe atomic force microscopy

In colloidal probe atomic force microscopy (AFM) surface forces cannot be measured without an accurate determination of the cantilever spring constant. The effective spring constant k depends upon the cantilever geometry and therefore should be measured in situ; additionally, k may be coupled to other measurement parameters. For example, colloidal probe AFM is frequently used to measure the slip length b at solid/liquid boundaries by comparing the measured hydrodynamic force with Vinogradova slip theory (V-theory). However, in this measurement k and b are coupled, hence, b cannot be accurately determined without knowing k to high precision. In this paper, a new in situ spring constant calibration method based upon the residuals, namely, the difference between experimental force-distance data and V-theory is presented and contrasted with two other popular spring constant determination methods. In this residuals calibration method, V-theory is fitted to the experimental force-distance data for a range of systematically varied spring constants where the only adjustable parameter in V-theory is the slip length b. The optimal spring constant k is that value where the residuals are symmetrically displaced about zero for all colloidal probe separations. This residual spring constant calibration method is demonstrated by studying three different liquids (n-decanol, n-hexadecane, and n-octane) and two different silane coated colloidal probe-silicon wafer systems (n-hexadecyltrichlorosilane and n-dodecyltrichlorosilane).

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

TU-FG-BRB-01: Dual Energy CT Proton Stopping Power Ratio Calibration and Validation with Animal Tissues

Purpose: The conversion of Hounsfield Unit (HU) to proton stopping power ratio (SPR) is a main source of uncertainty in proton therapy. In this study, the SPRs of animal tissues were measured and compared with prediction from dual energy CT (DECT) and single energy CT (SECT) calibrations. Methods: A stoichiometric calibration method for DECT was applied to predict the SPR using CT images acquired at 80 kVp and 140 kVp. The dual energy index was derived based on the HUs of the paired spectral images and used to calculate the SPRs of the materials. Tissue surrogates with known chemical compositions were used for calibration, and animal tissues (pig brain, liver, kidney; veal shank, muscle) were used for validation. The materials were irradiated with proton pencil beams, and SPRs were deduced from the residual proton range measured using a multi-layer ion chamber device. In addition, Gafchromic EBT3 films were used to measure the distal dose profiles after irradiation through the tissue samples and compared with those calculated by the treatment planning system using both DECT and SECT predicted SPRs. Results: The differences in SPR between DECT prediction and measurement were −0.31±0.36% for bone, 0.47±0.42% for brain, 0.67±0.15% for liver, 0.51±0.52% for kidney, and −0.96±0.15% for muscle. The corresponding results using SECT were 3.1±0.12%, 1.90±0.45%, −0.66±0.11%, 2.33±0.21%, and −1.70±0.17%. In the film measurements, average distances between film and calculated distal dose profiles were 0.35±0.12 mm for DECT calibration and −1.22±0.12 mm for SECT calibration for a beam with a range of 15.79 cm. Conclusion: Our study indicates that DECT is superior to SECT for proton SPR prediction and has the potential to reduce the range uncertainty to less than 2%. DECT may permit the use of tighter distal and proximal range uncertainty margins for treatment, thereby increasing the precision of proton therapy.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Neutron monitoring systems including gamma thermometers and methods of calibrating nuclear instruments using gamma thermometers

A method of calibrating a nuclear instrument using a gamma thermometer may include: measuring, in the instrument, local neutron flux; generating, from the instrument, a first signal proportional to the neutron flux; measuring, in the gamma thermometer, local gamma flux; generating, from the gamma thermometer, a second signal proportional to the gamma flux; compensating the second signal; and calibrating a gain of the instrument based on the compensated second signal. Compensating the second signal may include: calculating selected yield fractions for specific groups of delayed gamma sources; calculating time constants for the specific groups; calculating a third signal that corresponds to delayed local gamma flux based on the selected yield fractions and time constants; and calculating the compensated second signal by subtracting the third signal from the second signal. The specific groups may have decay time constants greater than 5.times.10.sup.-1 seconds and less than 5.times.10.sup.5 seconds.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Evaluation of Automated Model Calibration Techniques for Residential Building Energy Simulation

This simulation study adapts and applies the general framework described in BESTEST-EX (Judkoff et al 2010) for self-testing residential building energy model calibration methods. BEopt/DOE-2.2 is used to evaluate four mathematical calibration methods in the context of monthly, daily, and hourly synthetic utility data for a 1960's-era existing home in a cooling-dominated climate. The home's model inputs are assigned probability distributions representing uncertainty ranges, random selections are made from the uncertainty ranges to define 'explicit' input values, and synthetic utility billing data are generated using the explicit input values. The four calibration methods evaluated in this study are: an ASHRAE 1051-RP-based approach (Reddy and Maor 2006), a simplified simulated annealing optimization approach, a regression metamodeling optimization approach, and a simple output ratio calibration approach. The calibration methods are evaluated for monthly, daily, and hourly cases; various retrofit measures are applied to the calibrated models and the methods are evaluated based on the accuracy of predicted savings, computational cost, repeatability, automation, and ease of implementation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Evaluation of Automated Model Calibration Techniques for Residential Building Energy Simulation

This simulation study adapts and applies the general framework described in BESTEST-EX (Judkoff et al 2010) for self-testing residential building energy model calibration methods. BEopt/DOE-2.2 is used to evaluate four mathematical calibration methods in the context of monthly, daily, and hourly synthetic utility data for a 1960's-era existing home in a cooling-dominated climate. The home's model inputs are assigned probability distributions representing uncertainty ranges, random selections are made from the uncertainty ranges to define "explicit" input values, and synthetic utility billing data are generated using the explicit input values. The four calibration methods evaluated in this study are: an ASHRAE 1051-RP-based approach (Reddy and Maor 2006), a simplified simulated annealing optimization approach, a regression metamodeling optimization approach, and a simple output ratio calibration approach. The calibration methods are evaluated for monthly, daily, and hourly cases; various retrofit measures are applied to the calibrated models and the methods are evaluated based on the accuracy of predicted savings, computational cost, repeatability, automation, and ease of implementation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

High precision tilt stage as a key element to a universal test mirror for characterization and calibration of slope measuring instruments

The ultimate performance of surface slope metrology instrumentation, such as long trace profilers and auto-collimator based deflectometers, is limited by systematic errors that are increased when the entire angular range is used for metrology of significantly curved optics. At the ALS X-Ray Optics Laboratory, in collaboration with the HZB/BESSY-II and PTB (Germany) metrology teams, we are working on a calibration method for deflectometers, based on a concept of a universal test mirror (UTM) [V. V. Yashchuk et al., Proc. SPIE 6704, 67040A (2007)]. Potentially, the UTM method provides high performance calibration and accounts for peculiarities of the optics under test (e.g., slope distribution) and the experimental arrangement (e.g., the distance between the sensor and the optic under test). At the same time, the UTM calibration method is inherently universal, applicable to a variety of optics and experimental arrangements. In this work, we present the results of tests with a key component of the UTM system, a custom high precision tilt stage, which has been recently developed in collaboration with Physik Instrumente, GmbH. The tests have demonstrated high performance of the stage and its capability (after additional calibration) to provide angular calibration of surface slope measuring profilers over the entire instrumental dynamic range with absolute accuracy better than 30 nrad. The details of the stage design and tests are presented. We also discuss the foundation of the UTM method and calibration algorithm, as well as the possible design of a full scale UTM system.

47 OTHER INSTRUMENTATION↗

Performance of b-jet identification in the ATLAS experiment

The identification of jets containing b hadrons is important for the physics programme of the ATLAS experiment at the Large Hadron Collider. Several algorithms to identify jets containing b hadrons are described, ranging from those based on the reconstruction of an inclusive secondary vertex or the presence of tracks with large impact parameters to combined tagging algorithms making use of multi-variate discriminants. An independent b-tagging algorithm based on the reconstruction of muons inside jets as well as the b-tagging algorithm used in the online trigger are also presented. The b-jet tagging efficiency, the c-jet tagging efficiency and the mistag rate for light flavour jets in data have been measured with a number of complementary methods. The calibration results are presented as scale factors defined as the ratio of the efficiency (or mistag rate) in data to that in simulation. In the case of b jets, where more than one calibration method exists, the results from the various analyses have been combined taking into account the statistical correlation as well as the correlation of the sources of systematic uncertainty.

43 PARTICLE ACCELERATORS↗

Characterization of electron microscopes with binary pseudo-random multilayer test samples

Verification of the reliability of metrology data from high quality X-ray optics requires that adequate methods for test and calibration of the instruments be developed. For such verification for optical surface profilometers in the spatial frequency domain, a modulation transfer function (MTF) calibration method based on binarypseudo-random (BPR) gratings and arrays has been suggested and and proven to be an effective calibration method for a number of interferometric microscopes, a phase shifting Fizeau interferometer, and a scatterometer. Here we describe the details of development of binarypseudo-random multilayer (BPRML) test samples suitable for characterization of scanning (SEM) and transmission (TEM) electron microscopes. We discuss the results of TEM measurements with the BPRML test samples fabricated from a WiSi{sub 2}/Si multilayer coating with pseudo-randomly distributed layers. In particular, we demonstrate that significant information about the metrological reliability of the TEM measurements can be extracted even when the fundamental frequency of the BPRML sample is smaller than the Nyquist frequency of the measurements. The measurements demonstrate a number of problems related to the interpretation of the SEM and TEM data. Note that similar BPRML testsamples can be used to characterize X-ray microscopes. Corresponding work with X-ray microscopes is in progress.

36 MATERIALS SCIENCE↗

AutoCCS: automated collision cross-section calculation software for ion mobility spectrometry–mass spectrometry

Abstract Motivation Ion mobility spectrometry (IMS) separations are increasingly used in conjunction with mass spectrometry (MS) for separation and characterization of ionized molecular species. Information obtained from IMS measurements includes the ion’s collision cross section (CCS), which reflects its size and structure and constitutes a descriptor for distinguishing similar species in mixtures that cannot be separated using conventional approaches. Incorporating CCS into MS-based workflows can improve the specificity and confidence of molecular identification. At present, there is no automated, open-source pipeline for determining CCS of analyte ions in both targeted and untargeted fashion, and intensive user-assisted processing with vendor software and manual evaluation is often required. Results We present AutoCCS, an open-source software to rapidly determine CCS values from IMS-MS measurements. We conducted various IMS experiments in different formats to demonstrate the flexibility of AutoCCS for automated CCS calculation: (i) stepped-field methods for drift tube-based IMS (DTIMS), (ii) single-field methods for DTIMS (supporting two calibration methods: a standard and a new enhanced method) and (iii) linear calibration for Bruker timsTOF and non-linear calibration methods for traveling wave based-IMS in Waters Synapt and Structures for Lossless Ion Manipulations. We demonstrated that AutoCCS offers an accurate and reproducible determination of CCS for both standard and unknown analyte ions in various IMS-MS platforms, IMS-field methods, ionization modes and collision gases, without requiring manual processing. Availability and implementation https://github.com/PNNL-Comp-Mass-Spec/AutoCCS. Supplementary information Supplementary data are available at Bioinformatics online. Demo datasets are publicly available at MassIVE (Dataset ID: MSV000085979).

47 OTHER INSTRUMENTATION↗

Technical Note: Improving proton stopping power ratio determination for a deformable silicone-based 3D dosimeter using dual energy CT

Purpose: The aim of this study was to investigate whether the stopping power ratio (SPR) of a deformable, silicone-based 3D dosimeter could be determined more accurately using dual energy (DE) CT compared to using conventional methods based on single energy (SE) CT. The use of SECT combined with the stoichiometric calibration method was therefore compared to DECT-based determination. Methods: The SPR of the dosimeter was estimated based on its Hounsfield units (HUs) in both a SECT image and a DECT image set. The stoichiometric calibration method was used for converting the HU in the SECT image to a SPR value for the dosimeter while two published SPR calibration methods for dual energy were applied on the DECT images. Finally, the SPR of the dosimeter was measured in a 60 MeV proton by quantifying the range difference with and without the dosimeter in the beam path. Results: The SPR determined from SECT and the stoichiometric method was 1.10, compared to 1.01 with both DECT calibration methods. The measured SPR for the dosimeter material was 0.97. Conclusions: The SPR of the dosimeter was overestimated by 13% using the stoichiometric method and by 3% when using DECT. If the stoichiometric method should be applied for the dosimeter, the HU of the dosimeter must be manually changed in the treatment planning system in order to give a correct SPR estimate. Using a wrong SPR value will cause differences between the calculated and the delivered treatment plans.

07 ISOTOPE AND RADIATION SOURCES↗

Characterization of Electron Microscopes with Binary Pseudo-random Multilayer Test Samples

Verification of the reliability of metrology data from high quality X-ray optics requires that adequate methods for test and calibration of the instruments be developed. For such verification for optical surface profilometers in the spatial frequency domain, a modulation transfer function (MTF) calibration method based on binary pseudo-random (BPR) gratings and arrays has been suggested [1] and [2] and proven to be an effective calibration method for a number of interferometric microscopes, a phase shifting Fizeau interferometer, and a scatterometer [5]. Here we describe the details of development of binary pseudo-random multilayer (BPRML) test samples suitable for characterization of scanning (SEM) and transmission (TEM) electron microscopes. We discuss the results of TEM measurements with the BPRML test samples fabricated from a WiSi2/Si multilayer coating with pseudo-randomly distributed layers. In particular, we demonstrate that significant information about the metrological reliability of the TEM measurements can be extracted even when the fundamental frequency of the BPRML sample is smaller than the Nyquist frequency of the measurements. The measurements demonstrate a number of problems related to the interpretation of the SEM and TEM data. Note that similar BPRML test samples can be used to characterize X-ray microscopes. Corresponding work with X-ray microscopes is in progress.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Second ARM Aerosol Chemical Speciation Monitor Users’ Meeting Report

The aerosol chemical speciation monitor (ACSM) was developed to adapt the technology of the aerosol mass spectrometer (AMS) to routine, long-term, standalone monitoring. The calculation of particulate mass concentration from ACSM data requires the measurement of the response of the instrument to aerosol of specific size and composition as well as assumptions about the instrument response based on laboratory measurements and field experience acquired over more than two decades of operation of AMS and a decade of operation of the ACSM. Three parameters in the concentration calculations that are particularly important are the NO3 response factor (RFNO3), relative ionization efficiency (RIE), and the collection efficiency (CE). The values of RFNO3 and RIEs are determined from calibration, however the jump calibration method previously used in calibration can result in errors in the RIE for sulfate. This has been corrected by implementing a continuous calibration method. The default collection efficiency is 0.5. This has been shown to result in mass loadings that do not agree with mass determinations from other instruments because of effects of composition on the vaporization of the particles. The previous work of investigators addressing this issue is discussed. After preliminary work on ACSM and scanning mobility particle sizer (SMPS) data from the U.S. Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) user facility Southern Great Plains (SGP) observatory collected in late 2016 and 2017 produced a parameterization of composition dependent collection efficiency very different from the results of previous studies, SMPS data were examined and we determined that there was significant mass that the instrument did not capture because the particles with diameters larger than 465 nm are not counted by this instrument. Data for the ultra-high-sensitivity aerosol spectrometer (UHSAS), SMPS, and ACSM are available for nearly all of 2019. The data from UHSAS and SMPS collected in 2019 were compared. We found that the UHSAS data has particle counts and total volumes significantly less than measured by the condensation particle counter (CPC) and SMPS. The SMPS data were extended by fitting the average volume distribution with a log normal curve and using this relationship to estimate a mass value for the SMPS over extended diameter range. The extended SMPS mass values result in a CDCE parameterization that is in better agreement with the results of other investigators, but is still different from other formulations. The working group recommends that the ACSM data be processed with a collective efficiency (CE)=1, that this be documented clearly in the metadata, and the use of the default CE of 0.5 or a formulation of composition-dependent collection efficiencies (CDCE) chosen by the user should be implemented based on the ammonium nitrate mass fraction. This is clearly necessary for the wintertime SGP ACSM data because of the high nitrate concentrations.

47 OTHER INSTRUMENTATION↗

Evolutions and Calibrations of Long Gamma-Ray-burst Luminosity Correlations Revisited

Luminosity correlations of long gamma-ray bursts (GRBs) are extensively proposed as an effective complementarity to trace the Hubble diagram of the universe at high redshifts, which is of great importance to explore properties of dark energy. Recently, several empirical luminosity correlations have been statistically proposed from GRB observations. However, to treat a GRB as the distance indicator, there are two key issues: the redshift evolution of luminosity correlations and their calibrations. In this paper, we choose the Amati relation, the correlation between the peak spectra energy and the equivalent isotropic energy of GRBs (E{sub p}--E{sub iso}) as an example and find that the current GRB data set implies that there could be a evolution of the luminosity correlation with respect to the redshift. Therefore, we propose an extended Amati relation with two extra redshift-dependent terms to correct the redshift evolution of the GRB relation. Second, we carefully check the reliability of the calibration method using the low-redshift GRB data. Importantly, we find that the low-redshift calibration method does not take whole correlations between Ω{sub m} and coefficients into account. Neglecting this correlation information can break the degeneracies and obtain the biased constraint on Ω{sub m}, which is very sensitive to values of parameters for the calibration. A small shift in the parameters of the “calibrated” relation could significantly change the final constraint on Ω{sub m} in the low-redshift calibration method. Finally, we simulate several GRB samples with different statistical errors and find that, in order to correctly recover the fiducial value of Ω{sub m}, using the low-redshift calibration method, we need a large number of GRB samples with high precisions.

79 ASTRONOMY AND ASTROPHYSICS↗

A method to calibrate measurement instruments to optimize the spectrometer optics for experiment E94-107 at JLab

A method to calibrate measurement instruments through the fulfillment of physical laws is described. This method is particularly well suited to determine and/or improve magnetic spectrometer optics databases as well as to establish the best resolution achievable with them. Here, this method was applied to obtain the best resolution achievable in the excitation and binding energy spectra of several hypernuclei produced in the experiment E94-107 performed at JLab, allowing us to obtain sub-MeV resolutions.

47 OTHER INSTRUMENTATION↗

Method to calibrate fission chambers in Campbelling mode

Fission chambers are neutron detectors which are widely used to instrument experimental reactors such as material testing reactors or zero power reactors. In the presence of a high level mixed gamma and neutron flux, fission chambers can be operated in Campbelling mode (also known as 'fluctuation mode' or 'mean square voltage mode') to provide reliable and precise neutron related measurements. Fission chamber calibration in Campbelling mode (in terms of neutron flux) is usually done empirically using a calibrated reference detector. A major drawback of this method is that calibration measurements have to be performed in a neutron environment very similar to the one in which the calibrated detector will be used afterwards. What we propose here is a different approach based on characterizing the fission chamber response in terms of fission rate. This way, the detector calibration coefficient is independent from the neutron spectrum and can be determined prior to the experiment. The fissile deposit response to the neutron spectrum can then be assessed independently by other means (experimental or numerical). In this paper, the response of CEA made miniature fission chambers in Campbelling mode is studied. We use a theoretical model of the signal to calculate the calibration coefficient. Input parameters of the model come from statistical distribution of individual pulses. Supporting measurements have been made in the CEA Cadarache zero power reactor MINERVE and results are compared to an empirical Campbelling mode calibration. The tested fission chamber calibration coefficient is about 2 10{sup -26} A{sup 2}/Hz/(c/s). Both numerical and empirical methods give consistent results, however a deviation of about 15 % was observed. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Method to calibrate fission chambers in Campbelling mode

Fission chambers are neutron detectors which are widely used to instrument experimental reactors such as material testing reactors or zero power reactors. In the presence of a high level mixed gamma and neutron flux, fission chambers can be operated in Campbelling mode (also known as 'fluctuation mode' or 'mean square voltage mode') to provide reliable and precise neutron related measurements. Fission chamber calibration in Campbelling mode (in terms of neutron flux) is usually done empirically using a calibrated reference detector. A major drawback of this method is that calibration measurements have to be performed in a neutron environment very similar to the one in which the calibrated detector will be used afterwards. What is proposed here is a different approach based on characterizing the fission chamber response in terms of fission rate. This way, the detector calibration coefficient is independent from the neutron spectrum and can be determined prior to the experiment. The fissile deposit response to the neutron spectrum can then be assessed independently by other means (experimental or numerical). In this paper, the response of CEA-made miniature fission chambers in Campbelling mode is studied. A theoretical model of the signal is used to calculate the calibration coefficient. The model's input parameters come from statistical distribution of individual pulses. Supporting measurements were made in the CEA Cadarache zero power reactor MINERVE and results are compared to an empirical Campbelling mode calibration. The tested fission chamber calibration coefficient is roughly 2*10{sup -26} A{sup 2}/Hz/(c/s). Both numerical and empirical methods give consistent results, however a deviation of about 15% was observed. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

An Expectation-Maximization Method for Calibrating Synchronous Machine Models

The accuracy of a power system dynamic model is essential to its secure and efficient operation. Lower confidence in model accuracy usually leads to conservative operation and lowers asset usage. To improve model accuracy, this paper proposes an expectation-maximization (EM) method to calibrate the synchronous machine model using phasor measurement unit (PMU) data. First, an extended Kalman filter (EKF) is applied to estimate the dynamic states using measurement data. Then, the parameters are calculated based on the estimated states using maximum likelihood estimation (MLE) method. The EM method iterates over the preceding two steps to improve estimation accuracy. The proposed EM method’s performance is evaluated using a single-machine infinite bus system and compared with a method where both state and parameters are estimated using an EKF method. Sensitivity studies of the parameter calibration using EM method are also presented to show the robustness of the proposed method for different levels of measurement noise and initial parameter uncertainty.

EM Algorithms↗