A high-speed spectrograph shutter

Device can operate in close-open-close mode. Beam splitter placed behind static-slit assembly allows use of more than one camera. Each frame in particular series may be conveniently varied in exposure time and spacing. This can be done independent of other frames in the series. In ''open'' position, shutter transmits light over wide wavelength range.

Miller, M. H.↗

Image reproduction with interactive graphics

Software application or development in optical image digital data processing requires a fast, good quality, yet inexpensive hard copy of processed images. To achieve this, a Cambo camera with an f 2.8/150-mm Xenotar lens in a Copal shutter having a Graflok back for 4 x 5 Polaroid type 57 pack-film has been interfaced to an existing Adage, AGT-30/Electro-Mechanical Research, EMR 6050 graphic computer system. Time-lapse photography in conjunction with a log to linear voltage transformation has resulted in an interactive system capable of producing a hard copy in 54 sec. The interactive aspect of the system lies in a Tektronix 4002 graphic computer terminal and its associated hard copy unit.

Buckner, J. D.↗

Development of a drive system for a sequential space camera

An electronically commutated dc motor is reported for driving the camera claw and magazine, and a stepper motor is described for driving the shutter with the two motors synchronized electrically. Subsequent tests on the breadboard positively proved the concept, but further development beyond this study should be done. The breadboard testing also established that the electronically commutated motor can control speed over a wide dynamic range, and has a high torque capability for accelerating loads. This performance suggested the possibility of eliminating the clutch from the system while retaining all of the other mechanical features of the DAC, if the requirement for independent shutter speeds and frame rates can be removed. Therefore, as a final step in the study, the breadboard shutter and shutter drive were returned to the original DAC configuration, while retaining the brushless dc motor drive.

Sharpsteen, J. T.↗

Injector Mixing Efficiency Experiments

Various optical diagnostic techniques such as laser induce fluorescence, Raman spectroscopy, laser Doppler velocimetry, and laser light scattering have been employed to study the flowfield downstream of a single injector element in a optically accessible rocket chamber at Penn State for a number o years. These techniques have been used with both liquid and gaseous oxygen at pressures up to 1000 psia which is the limit of the facility. The purpose of the test programs at Penn State were to develop the techniques and to study the flow field from various injector designs. To extend these studies to higher pressure and ultimately to multiple injectors require the capabilities of the Marshall Space Flight Center. These studies will extend the data base available for the various injector designs to higher pressure as well as to determine the interaction between multiple injectors. During this effort the Princeton Instruments ICCD camera was set up and checked out. The functionality of the system has been thoroughly checked and the shutter compensation time was found to be not working. The controller was returned to the manufacturer for warranty repair. The sensitivity has been measured and found to be approximately 60 counts per photon at maximum gain which agrees with the test data supplied by the manufacturer. The actual value depends on wavelength. The Princeton Instruments camera was been installed in a explosion proof tube for use with the rocket combustor. A 35 mm camera was also made ready for taking still photos inside the combustor. A fiber optic was used to transmit the laser light from an argon-ion laser to the rocket combustor for the light scattering images. This images were obtained for a LOX-hydrogen swirl coax injector. Several still photos were also obtained with the 35 mm camera for these firings.

Moser, Marlow D.↗

Global Ultraviolet Imaging Processing for the GGS Polar Visible Imaging System (VIS)

The Visible Imaging System (VIS) on Polar spacecraft of the NASA Goddard Space Flight Center was launched into orbit about Earth on February 24, 1996. Since shortly after launch, the Earth Camera subsystem of the VIS has been operated nearly continuously to acquire far ultraviolet, global images of Earth and its northern and southern auroral ovals. The only exceptions to this continuous imaging occurred for approximately 10 days at the times of the Polar spacecraft re-orientation maneuvers in October, 1996 and April, 1997. Since launch, approximately 525,000 images have been acquired with the VIS Earth Camera. The VIS instrument operational health continues to be excellent. Since launch, all systems have operated nominally with all voltages, currents, and temperatures remaining at nominal values. In addition, the sensitivity of the Earth Camera to ultraviolet light has remained constant throughout the operation period. Revised flight software was uploaded to the VIS in order to compensate for the spacecraft wobble. This is accomplished by electronic shuttering of the sensor in synchronization with the 6-second period of the wobble, thus recovering the original spatial resolution obtainable with the VIS Earth Camera. In addition, software patches were uploaded to make the VIS immune to signal dropouts that occur in the sliprings of the despun platform mechanism. These changes have worked very well. The VIS and in particular the VIS Earth Camera is fully operational and will continue to acquire global auroral images as the sun progresses toward solar maximum conditions after the turn of the century.

Frank, L. A.↗

Method for determining thermo-physical properties of specimens

The square root of the product of thermophysical properties q, c and k, where p is density, c is specific heat and k is thermal conductivity, is determined directly on a test specimen such as a wind tunnel model. The test specimen and a reference specimen of known specific heat are positioned at a given distance from a heat source. The specimens are provided with a coating, such as a phase change coating, to visually indicate that a given temperature was reached. A shutter interposed between the heat source and the specimens is opened and a motion picture camera is actuated to provide a time record of the heating step. The temperature of the reference specimen is recorded as a function of time. The heat rate to which both the test and reference specimens were subjected is determined from the temperature time response of the reference specimen by the conventional thin-skin calorimeter equation.

Jones, R. A.↗

Performance testing of the iX Cameras iSpeed 727 high-speed camera

This work evaluated the iX Cameras iSpeed 727, a commercial CMOS-based continuous- recording high-speed camera. Various parameters of importance in the scheme of accurate time-resolved measurements and photonic quantification have been measured under controlled conditions on the bench, using state-of-the-art instrumentation. We will detail the procedures and results of the tests laid out to measure sensor sensitivity, linearity, signal-to-noise ratio and image lag. We also looked into the electronic shutter performance and accuracy, as exposure time is of particular interest to high-speed imaging. The results of the tests show that this camera matches or exceeds the performance of competing units in most aspects, but that, as is the case for other high-speed camera systems, corrections are necessary to make full use of the image data from a quantitative perspective.

42 ENGINEERING↗

UV Capabilities of the CETUS Multi-Object Spectrometer (MOS) and NUV/FUV Camera

The Cosmic Evolution Through UV Spectroscopy (CETUS) concept enables parallel observations by the UV multiobject spectrometer (MOS) and near-UV/far-UV camera which operate simultaneously but independently with their separate field of views. The near-UV MOS can target up to 100 objects at a time without confusion with nearby sources or background zodiacal light. This multiplexing will allow over 100,000 galaxies to be observed over a typical mission lifetime. The MOS includes a next-generation micro-shutter array (NGMSA), an efficient aspheric Offner-like spectrometer design with a convex grating, and nanotube light traps for suppressing unwanted wavelengths. The NUV/FUV Camera has the capability to image in a range of sub-bands from 115-400 nm at the same time the MOS is operating at 180-350 nm. The UV camera has a similar Offner-like relay, selectable filters, and two separate detectors to optimize observing in either the far-UV (115-175 nm) or the near-UV (180-400 nm) utilizing a CsI Micro-Channel Plate detector (MCP) and a CCD respectively.

The Cosmic Evolution Through UV Spectroscopy (CETU↗

Analytical Tools for Cloudscope Ice Measurement

The cloudscope is a ground or aircraft instrument for viewing ice crystals impacted on a sapphire window. It is essentially a simple optical microscope with an attached compact CCD video camera whose output is recorded on a Hi-8 mm video cassette recorder equipped with digital time and date recording capability. In aircraft operation the window is at a stagnation point of the flow so adiabatic compression heats the window to sublimate the ice crystals so that later impacting crystals can be imaged as well. A film heater is used for ground based operation to provide sublimation, and it can also be used to provide extra heat for aircraft operation. The compact video camera can be focused manually by the operator, and a beam splitter - miniature bulb combination provide illumination for night operation. Several shutter speeds are available to accommodate daytime illumination conditions by direct sunlight. The video images can be directly used to qualitatively assess the crystal content of cirrus clouds and contrails. Quantitative size spectra are obtained with the tools described in this report. Selected portions of the video images are digitized using a PCI bus frame grabber to form a short movie segment or stack using NIH (National Institute of Health) Image software with custom macros developed at DRI. The stack can be Fourier transform filtered with custom, easy to design filters to reduce most objectionable video artifacts. Particle quantification of each slice of the stack is performed using digital image analysis. Data recorded for each particle include particle number and centroid, frame number in the stack, particle area, perimeter, equivalent ellipse maximum and minimum radii, ellipse angle, and pixel number. Each valid particle in the stack is stamped with a unique number. This output can be used to obtain a semiquantitative appreciation of the crystal content. The particle information becomes the raw input for a subsequent program (FORTRAN) that synthesizes each slice and separates the new from the sublimating particles. The new particle information is used to generate quantitative particle concentration, area, and mass size spectra along with total concentration, solar extinction coefficient, and ice water content. This program directly creates output in html format for viewing with a web browser.

Arnott, W. Patrick↗

Camera add-on records time of exposure

Time photograph is taken and is permanently recorded on edge of exposure by compact electronics module that attaches to camera case. Single-chip timing circuit drives LED display, which is imaged on film plane. Normally blanked display is unblanked when shutter switch is activated.

Compton, E. C.↗

Synchronizing Light Pulses With Video Camera

Interface circuit triggers laser or other external source of light to flash in proper frame and field (at proper time) for video recording and playback in "pause" mode. Also increases speed of electronic shutter (if any) during affected frame to reduce visibility of background illumination relative to that of laser illumination.

Kalshoven, James E., Jr.↗

High-speed pulse camera

Miniaturized, 16 mm high speed pulse camera takes spectral photometric photographs upon instantaneous command. The design includes a low-friction, low-inertia film transport, a very thin beryllium shutter driven by a low-inertia stepper motor for minimum actuation time after a pulse command, and a binary encoder.

Lawson, J. R.↗

EOD Facilities Manual. Camera Calibration Laboratory Capabilities

The tests and equipment are described for measuring the exact performance characteristics of camera systems for earth resources, space, and other applications. The tests discussed include: modulation transfer function, field irradiance, veiling glare, T-number tests, shutter speed, spectral transmission, and focal length.

Source record↗

Laser speckle strain and deformation sensor using linear array image cross-correlation method for specifically arranged triple-beam triple-camera configuration

The invention provides a method of triple-beam and triple-sensor in a laser speckle strain/deformation measurement system. The triple-beam/triple-camera configuration combined with sequential timing of laser beam shutters is capable of providing indications of surface strain and structure deformations. The strain and deformation quantities, the four variables of surface strain, in-plane displacement, out-of-plane displacement and tilt, are determined in closed form solutions.

Sarrafzadeh-Khoee, Adel K.↗

DC drive system for cine/pulse cameras

Camera-drive functions are separated mechanically into two groups which are driven by two separate dc brushless motors. First motor, a 90 deg stepper, drives rotating shutter; second electronically commutated motor drives claw and film transport. Shutter is made of one piece but has two openings for slow and fast exposures.

Gerlach, R. H.↗

Computer-Driven Keratometer

Simple optical system measures corneal deformations. Shuttered laser briefly illuminates subject's eye through reticle, projecting concentric rings of light on eye. Reflected by beam splitter and mirror into solid-state video camera, ring pattern compared with reference pattern by computer. Keratometer assists in rapid diagnosis of eye ailments and preparation of cornea for surgery. Unit does not require critical alignment with eye; results more reliable, and easier to use.

Baroth, Edmund C.↗

Mariner 10 star photography

Two identical television cameras, each having a long and short focal-length capability, were carried aboard the spacecraft for the reconnaissance of Venus and Mercury. These telescopes were used in conjunction with a filter-wheel assembly and a focal-plane shutter to provide an image on a slow-scan vidicon tube. The results obtained with this system are discussed, giving attention to aspects of sensitivity and questions related to focal length and geometric distortion.

Thorpe, T. E.↗