Search NASA⌕ Search

SEARCH · Search NASA

Results for “Capacitance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Ultrahigh Temperature Capacitive Pressure Sensor

Robust, miniaturized sensing systems are needed to improve performance, increase efficiency, and track system health status and failure modes of advanced propulsion systems. Because microsensors must operate in extremely harsh environments, there are many technical challenges involved in developing reliable systems. In addition to high temperatures and pressures, sensing systems are exposed to oxidation, corrosion, thermal shock, fatigue, fouling, and abrasive wear. In these harsh conditions, sensors must be able to withstand high flow rates, vibration, jet fuel, and exhaust. In order for existing and future aeropropulsion turbine engines to improve safety and reduce cost and emissions while controlling engine instabilities, more accurate and complete sensor information is necessary. High-temperature (300 to 1,350 C) capacitive pressure sensors are of particular interest due to their high measurement bandwidth and inherent suitability for wireless readout schemes. The objective of this project is to develop a capacitive pressure sensor based on silicon carbon nitride (SiCN), a new class of high-temperature ceramic materials, which possesses excellent mechanical and electric properties at temperatures up to 1,600 C.

Harsh, Kevin↗

Wireless Capacitive Pressure Sensor Operating up to 400 Celcius from 0 to 100 psi Utilizing Power Scavenging

In this paper, a wireless capacitive pressure sensor developed for the health monitoring of aircraft engines has been demonstrated. The sensing system is composed of a Clapp-type oscillator that operates at 131 MHz. The Clapp oscillator is fabricated on a alumina substrate and consists of a Cree SiC (silicon carbide) MESFET (Metal Semiconductor Field Effect Transistors), this film inductor, Compex chip capacitors and Sporian Microsystem capacitive pressure sensor. The resonant tank circuit within the oscillator is made up of the pressure sensor and a spiral thin film inductor, which is used to magnetically couple the wireless pressure sensor signal to a coil antenna placed over 1 meter away. 75% of the power used to bias the sensing system is generated from thermoelectric power modules. The wireless pressure sensor is operational at room temperature through 400 C from 0 to 100 psi and exhibits a frequency shift of over 600 kHz.

Scardelletti, Maximilian C.↗

Wireless Capacitive Pressure Sensor With Directional RF Chip Antenna for High Temperature Environments

This paper presents the design, fabrication and characterization of a wireless capacitive pressure sensor with directional RF chip antenna that is envisioned for the health monitoring of aircraft engines operating in harsh environments. The sensing system is characterized from room temperature (25 C) to 300 C for a pressure range from 0 to 100 psi. The wireless pressure system consists of a Clapp-type oscillator design with a capacitive MEMS pressure sensor located in the LC-tank circuit of the oscillator. Therefore, as the pressure of the aircraft engine changes, so does the output resonant frequency of the sensing system. A chip antenna is integrated to transmit the system output to a receive antenna 10 m away.The design frequency of the wireless pressure sensor is 127 MHz and a 2 increase in resonant frequency over the temperature range of 25 to 300 C from 0 to 100 psi is observed. The phase noise is less than minus 30 dBcHz at the 1 kHz offset and decreases to less than minus 80 dBcHz at 10 kHz over the entire temperature range. The RF radiation patterns for two cuts of the wireless system have been measured and show that the system is highly directional and the MEMS pressure sensor is extremely linear from 0 to 100 psi.

Pressure sensor↗

Characterization of Rapid Charging Events Due to Sheath Capacitance and Impact on the International Space Station Plasma Hazard Process

During an Extravehicular Activity (EVA), if the Extravehicular Mobility Unit (EMU) makes galvanic contact with the International Space Station (ISS), a negative Floating Potential (FP) can lead to an arcing hazard when it exceeds -45.5 V, and a positive FP can produce a DC current high enough to stimulate the astronaut’s muscles (5 mA), and also cause a hazard. The Boeing Space Environments team developed and utilizes a Plasma Interaction Model (PIM) in order to calculate the ISS FP based on the plasma environment, ISS velocity, geomagnetic field, solar array and ISS orientation, and solar array regulation to support EVA planning operations. Presently, the model excludes the sheath capacitance, resulting in the total potential drop being across the dielectric surface of the vehicle. Data from the Floating Potential Measurement Unit (FPMU) show this assumption to be generally true. However, Rapid Charging Events (RCE) are often observed in the FPMU data at eclipse exit when the electron number density, Ne, is low (less than 5(sub e)10 m (exp-3)). During these events, the FP can rise more than 40 V in one to five seconds. There is then a relaxation phase where the FP drops back to the normal FP values. The PIM model is not capable of producing these RCEs. It was thought that the inclusion of the sheath in PIM could improve the charging predictions, particularly as related to RCEs. A parametric study was performed to determine what portion of the measured FP is across the sheath for a range of Ne experienced by the ISS, and if the inclusion of the sheath in PIM is necessary. Results show that the potential drop across the sheath is negligible at times when the N(sub e) is greater than 1(sub e)11 m-3. However, there appears to be a transitional region between 1(sub e)10 m(exp -3) and 1(sub e)11 m(exp -3) where the sheath capacitance becomes more significant. During those conditions the potential drop across the sheath can be larger than the potential drop across the dielectric for short periods (1-5 seconds). These results agree remarkably well with measurements made by the FPMU. The inclusion of the sheath explains why high charging measurements occur when the Ne is low at eclipse exit and even times when the solar arrays are not a significant driver (i.e., potentials often rise as the ISS flies through spread-F). Results also show that the RCEs are not a safety concern because the potential drop across the dielectric surface does not exceed -45.5 V. In that case, the EMU would not arc. This gives high confidence in the low probability of an arcing hazard occurring.

plasma environment↗

Thermal Vacuum Test Correlation of A Zero Propellant Load Case Thermal Capacitance Propellant Gauging Analytics Model

This thesis describes the development and test data validation of the thermal model that is the foundation of a thermal capacitance spacecraft propellant load estimator. Specific details of creating the thermal model for the diaphragm propellant tank used on NASA's Magnetospheric Multiscale spacecraft using ANSYS and the correlation process implemented to validate the model are presented. The thermal model was correlated to within plus or minus 3 degrees Centigrade of the thermal vacuum test data, and was found to be relatively insensitive to uncertainties in applied heat flux and mass knowledge of the tank. More work is needed, however, to refine the thermal model to further improve temperature predictions in the upper hemisphere of the propellant tank. Temperatures predictions in this portion were found to be 2-2.5 degrees Centigrade lower than the test data. A road map to apply the model to predict propellant loads on the actual MMS spacecraft toward its end of life in 2017-2018 is also presented.

Thermal↗

Thermal Vacuum Test Correlation of a Zero Propellant Load Case Thermal Capacitance Propellant Gauging Analytical Model

This thesis describes the development and correlation of a thermal model that forms the foundation of a thermal capacitance spacecraft propellant load estimator. Specific details of creating the thermal model for the diaphragm propellant tank used on NASA's Magnetospheric Multiscale spacecraft using ANSYS and the correlation process implemented are presented. The thermal model was correlated to within plus or minus 3 degrees Celsius of the thermal vacuum test data, and was determined sufficient to make future propellant predictions on MMS. The model was also found to be relatively sensitive to uncertainties in applied heat flux and mass knowledge of the tank. More work is needed to improve temperature predictions in the upper hemisphere of the propellant tank where predictions were found to be 2 to 2.5 C lower than the test data. A road map for applying the model to predict propellant loads on the actual MMS spacecraft toward its end of life in 2017-2018 is also presented.

Gauging↗

Packaged Capacitive Pressure Sensor System for Aircraft Engine Health Monitoring

This paper describes the development of a packaged silicon carbide (SiC) based MEMS pressure sensor system designed specifically for a conventional turbofan engine. The electronic circuit is based on a Clapp-type oscillator that incorporates a 6H-SiC MESFET, a SiCN MEMS capacitive pressure sensor, titanate MIM capacitors, wirewound inductors, and thick film resistors. The pressure sensor serves as the capacitor in the LC tank circuit, thereby linking pressure to the resonant frequency of the oscillator. The oscillator and DC bias circuitry were fabricated on an alumina substrate and secured inside a metal housing. The packaged sensing system reliably operates at 0 to 350 psi and 25 to 540C. The system has a pressure sensitivity of 6.8 x 10E-2 MHzpsi. The packaged system shows negligible difference in frequency response between 25 and 400C. The fully packaged sensor passed standard benchtop acceptance tests and was evaluated on a flight-worthy engine.

Harsh environment↗

Preliminary Results from Propellant Mass Gauging with Electrical Capacitance Tomography

Propellants mass gauging technologies designed to work in an accelerated environment, where the propellant remains settled at one end of the propellant tank, do not work well in a microgravity environment because the propellant is not necessarily settled. While some microgravity mass gauging technologies exist at various TRLs, most of them have major disadvantages. Improvements in microgravity propellant mass gauging will result in improvements to many areas of propellant management, which influences performance and mission assurance. Electrical Capacitance Tomography (ECT) is a sensing technology that is able to reconstruct the liquid distribution inside of a tank, which can then be integrated to obtain mass. ECT mass gauging recently achieved high accuracy in laboratory testing, <0.1% liquid volume measurement error, even during sloshing. While ECT mass gauging will theoretically work during all phases of flight, it had not yet been tested in microgravity. The NASA KSC Launch Services Program, with support from the Flight Opportunities Program, successfully flew an ECT liquid mass gauging system experiment on a Zero-G parabolic flight aircraft. Basics of ECT measurement theory, details of the experiment setup and flights, and preliminary results will be discussed. The preliminary results suggest that, even in the current prototype generation, ECT sensor systems will be useful as a propellant mass gauging technology in both an accelerated and microgravity environment.

mass gauging↗

Preliminary Results From Propellant Mass Gauging in Microgravity with Electrical Capacitance Tomography

This presentation is a shortened and simplified version of the original from Jed Storey intended for usage with an a.i. Solutions' "Lunch-and-learn" audience. It reviews the setup, execution, and some preliminary results from the Electrical Capacitive Tomography experiment conducted by NASA KSC Launch Services Program flown aboard a Zero-G aircraft earlier this year. The original is STRIVES submission 20220010165. Some extra images and videos have been added and some detailed content removed since the purpose of this presentation is less technical than that of it's parent.

mass gauging↗

Propellant Mass Gauging in Microgravity with Electrical Capacitance Tomography

Advancements in microgravity propellant mass gauging will result in improvements to many areas of propellant management, which influences space vehicle performance and mission assurance. Propellant mass gauging technologies designed to work in an accelerated environment, where the propellant remains settled at one end of the propellant tank, do not always work well in a microgravity environment because the propellant is not necessarily settled. While some microgravity mass gauging technologies exist at various stages of development, most of them have major disadvantages. Electrical Capacitance Tomography (ECT) is a sensing technology that is able to reconstruct the liquid distribution inside of a tank, which can then be integrated to obtain mass. While ECT mass gauging will theoretically work during all phases of flight, it had not yet been tested in microgravity. The NASA Kennedy Space Center Launch Services Program, with support from the Flight Opportunities Program, successfully tested an ECT liquid mass gauging system experiment on a parabolic flight aircraft in May 2022. Basics of ECT measurement theory, details of the experiment setup, data processing, ground test results, and the flight test result will be discussed. The results suggest that ECT sensor systems will be useful as a propellant mass gauging technology in both accelerated and microgravity environments.

electrical capacitance tomography↗