Reassessing Wind Potential Estimates for India: Economic and Policy Implications

We assess developable on-shore wind potential in India at three different hub-heights and under two sensitivity scenarios – one with no farmland included, the other with all farmland included. Under the “no farmland included” case, the total wind potential in India ranges from 748 GW at 80m hub-height to 976 GW at 120m hub-height. Under the “all farmland included” case, the potential with a minimum capacity factor of 20 percent ranges from 984 GW to 1,549 GW. High quality wind energy sites, at 80m hub-height with a minimum capacity factor of 25 percent, have a potential between 253 GW (no farmland included) and 306 GW (all farmland included). Our estimates are more than 15 times the current official estimate of wind energy potential in India (estimated at 50m hub height) and are about one tenth of the official estimate of the wind energy potential in the US.

17 WIND ENERGY↗

Utility-Scale Solar Data Update (2020 Edition) [Slides]

Berkeley Lab’s 2020 update of utility-scale solar data and trends provides an overview of key trends in the U.S. market, with a focus on 2019. Highlights of this year’s update include: More than 4.5 GWAC of utility-scale solar (i.e., ground-mounted solar projects larger than 5 MWAC) achieved commercial operations in 2019, bringing cumulative capacity to 29 GWAC. Projects are spread across all 10 regions that we track, though more heavily concentrated in the sunniest regions. The median installed cost of projects that came online in 2019 fell to $\$$1.4/WAC ($\$$1.2/WDC), down 20% from 2018 and down by more than 70% from 2010. 77% of projects and 88% of capacity added in 2019 used single-axis tracking. Average capacity factors range from 17% in the least-sunny regions to 30% where it is sunniest. Single-axis tracking adds roughly five percentage points to capacity factor in the regions with the strongest solar resource. Nationwide average levelized power purchase agreement (PPA) prices fell to $\$$24/MWh in 2019, down 17% from 2018 and more than 80% since 2010. Thirty-nine projects (totaling 4.2 GWAC) in our PPA price sample include battery storage (totaling 2.3 GWAC and 9.5 GWh). In the “lower 48” states, a number of these recent PV+battery PPAs have been inked in the mid-$\$$20/MWh range (levelized in 2019 dollars).Not including the 30% investment tax credit (ITC), the median levelized cost of energy (LCOE) from utility-scale PV has declined by 85% since 2010, to $\$$40/MWh in 2019. When the 30% ITC is included within the LCOE calculation, the median LCOE closely tracks the median PPA price over time. In higher-penetration markets like CAISO, the value of solar has been declining, but falling PPA prices have largely kept pace, preserving solar's net value. At the end of 2019, there were nearly 370 GW of solar in interconnection queues from all 7 ISOs and 30 additional utilities across the country. Nearly a third of this proposed solar capacity is paired with battery storage.

14 SOLAR ENERGY↗

Front-End Engineering Design (FEED) Study for a Carbon Capture Plant Retrofit to a Natural Gas-Fired Gas Turbine Combined Cycle Power Plant (2x2x1 Duct-Fired 758-MWe Facility with F Class Turbines)

A comprehensive front-end engineering design (FEED) study has been undertaken by Bechtel National Inc. (Bechtel) for locating a post-combustion capture and compression (PCC) unit at Panda’s Sherman natural gas–combined cycle (NGCC) power plant in Sherman, Texas. This is described in the unredacted FEED Study report (Attachment 1) with all supporting documents, numbering over 150. The Study Report is publicly available. Sizing of the PCC plant is based on treating an amount of flue gas equivalent to that produced when generating 420 MW, which is approximately 68% of the total flue gas emitted by the NGCC power plant operating at guarantee condition with duct burners off. A reduced power plant capacity factor was used for sizing the PCC plant because the gas turbines at the site often operate at reduced load due to the high penetration of renewable power in the ERCOT region. The cost of carbon capture is primarily driven by capital cost (and therefore is highly sensitive to capacity factor). Sizing the capture unit so that when used it is nearly always operating at full capacity is critical to the economic viability of the proposed investment.

03 NATURAL GAS↗

Analysis of Nuclear Fuel Cycle Data

Electricity generated using nuclear power accounted for 18.9% of all electricity consumed in the United States in 2021, putting it in third place behind natural gas (38%) and coal (22%) power plants. Nuclear power plants boast a significantly higher uptime or capacity factor—90% and above—compared to 49.1% for coal fired power plants and 56.6% for natural gas power plants. Renewable energy sources, such as solar photovoltaic (PV) and wind electricity, have lower capacity factors: 24.9% and 36.3%, respectively. In addition, nuclear power is cleaner than both coal and natural gas fired power plants. With the passing of the 2022 Inflation Reduction Act, significant tax credits will be claimed by producers of hydrogen with well-to-gate greenhouse gas (GHG) emissions below 0.45 kg CO 2e /kg H 2 . This has sparked interest in using clean sources of electricity, including nuclear power, to generate H 2 via water electrolysis. As uranium is a primary fuel for modern nuclear power plants, the upstream emissions from nuclear fuel production greatly impact the GHG emissions related to all nuclear power end use. Therefore, it is important to accurately determine the upstream emissions associated with the nuclear fuel cycle of nuclear power production in the United States. In this analysis, the nuclear fuel cycle was separated into distinct steps to allow better understanding of the chemical and energy inputs at each step of the fuel cycle. This also provides details of the GHG emissions at each step in the nuclear fuel cycle. The transportation distance for each step of the fuel cycle was updated to account for the locations of uranium processing facilities along the supply chain of the current U.S. nuclear power plants. Finally, all the updated values were incorporated into Argonne National Laboratory’s Greenhouse Gases, Regulated Emissions, and Energy Use in Technologies (GREET) model.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Transmission Benefits of Co-Locating Concentrating Solar Power and Wind

In some areas of the U.S. transmission constraints are a limiting factor in deploying new wind and concentrating solar power (CSP) plants. Texas is an example of one such location, where the best wind and solar resources are in the western part of the state, while major demand centers are in the east. The low capacity factor of wind is a compounding factor, increasing the relative cost of newtransmission per unit of energy actually delivered. A possible method of increasing the utilization of new transmission is to co-locate both wind and concentrating solar power with thermal energy storage. In this work we examine the benefits and limits of using the dispatachability of thermal storage to increase the capacity factor of new transmission developed to access high quality solar andwind resources in remote locations.

14 SOLAR ENERGY↗

Larger Turbines and the Future Cost of Wind Energy (Poster)

The move to larger turbines has been observed in the United States and around the world. Turbine scaling increases energy capture while reducing general project infrastructure costs and landscape impacts, each of which of can reduce the cost of wind energy. However, scaling in the absence of innovation, can increase turbine costs. The ability of turbine designers and manufacturers to continue toscale turbines, while simultaneously reducing costs, is an important factor in long-term viability of the industry. This research seeks to better understand how technology innovation can allow the continued development of larger turbines on taller towers while also achieving lower cost of energy. Modeling incremental technology improvements identified over the past decade demonstrates that costreductions on the order of 10%, and capacity factor improvements on the order of 5% (for sites with annual mean wind speed of 7.25 m/s at 50m), are achievable for turbines up to 3.5 MW. However, to achieve a 10% cost reduction and a 10% capacity factor improvement for turbines up to 5 MW, additional technology innovations must be developed and implemented.

17 WIND ENERGY↗

Forecastability as a Design Criterion in Wind Resource Assessment: Preprint

This paper proposes a methodology to include the wind power forecasting ability, or 'forecastability,' of a site as a design criterion in wind resource assessment and wind power plant design stages. The Unrestricted Wind Farm Layout Optimization (UWFLO) methodology is adopted to maximize the capacity factor of a wind power plant. The 1-hour-ahead persistence wind power forecasting method is used to characterize the forecastability of a potential wind power plant, thereby partially quantifying the integration cost. A trade-off between the maximum capacity factor and the forecastability is investigated.

17 WIND ENERGY↗

Nuclear Energy Response in the EMF27 Study

The nuclear energy response for mitigating global climate change across eighteen participating models of the EMF27 study is investigated. Diverse perspectives on the future role of nuclear power in the global energy system are evident in the broad range of nuclear power contributions from participating models of the study. In the Baseline scenario without climate policy, nuclear electricity generation and shares span 0 – 66 EJ/ year and 0 - 25% in 2100 for all models, with a median nuclear electricity generation of 39 EJ/year (1,389 GWe at 90% capacity factor) and median share of 9%. The role of nuclear energy increased under the climate policy scenarios. The median of nuclear energy use across all models doubled in the 450 ppm CO2e scenario with a nuclear electricity generation of 67 EJ/year (2,352 GWe at 90% capacity factor) and share of 17% in 2100. The broad range of nuclear electricity generation (11 – 214 EJ/year) and shares (2 - 38%) in 2100 of the 450 ppm CO2e scenario reflect differences in the technology choice behavior, technology assumptions and competitiveness of low carbon technologies. Greater clarification of nuclear fuel cycle issues and risk factors associated with nuclear energy use are necessary for understanding the nuclear deployment constraints imposed in models and for improving the assessment of the nuclear energy potential in addressing climate change.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Flexing the Limits of Land-Based Wind Turbine Rotor Growth

The Big Adaptive Rotor (BAR) project works to design and enable the next generation of land-based wind turbines with rotors that stretch 206 meters (m) in diameter, which will increase capacity factors by 10% or more over a typical land-based turbine. These high-energy-capture turbines have lower specific-power ratings, meaning they have larger rotors relative to the size of their generator, which helps them capture more wind and perform better at lower wind speeds, thereby increasing the turbine capacity factor. High-energy-capture turbines with larger rotors have many advantages, but the length and width of their blades creates transportation challenges that must be overcome to make true on the adage, bigger is better.

wind, big, adaptive, rotor↗

Effects of the U.S. inflation reduction act on SMR economics

The U.S. Inflation Reduction Act (IRA) of 2022 provides a wide array of tax credits and other incentives for low-carbon energy. The technology-neutral clean generation production tax credit (PTC) (Section 45Y of the U.S. Internal Revenue Code) and the technology-neutral investment tax credit (ITC) (Section 48E) lower the net cost of new electricity generation projects with zero or negative greenhouse gas emission rates. We evaluate the impact of the IRA legislation—specifically the PTC and ITC—on the cost-competitiveness of small modular reactors (SMRs). We use the Argonne Low-carbon Energy Analysis Framework (A-LEAF) model to calculate the capacity factor of an SMR with a range of hypothetical variable operating and maintenance (O&M) costs in the Electric Reliability Council of Texas (ERCOT) electricity market. We selected ERCOT for market modeling because of its competitive structure, available data, and extensive use in prior literature. We use a discounted cash flow model to calculate the SMR’s net present value based on the market prices and capacity factors from A-LEAF, hypothetical ranges of capital and variable O&M costs, and other input parameters, with or without the IRA tax credits. We determine the SMR owner’s optimal choice of PTC or ITC for the hypothetical ranges of capital and variable O&M costs. We also evaluate potential shifts in the SMR owner’s optimal choice of PTC or ITC based on historical patterns of nuclear capital cost overruns in the United States. We also assess the sensitivity of our results to longer PTC period and electricity prices from the New England market, which tend to be higher than electricity prices in ERCOT. We find that even with the IRA tax credits, only SMRs with low capital and variable O&M costs would be economically feasible in the low-price ERCOT market scenario modeled. A longer PTC period and higher-price market such as New England, however, would significantly expand the economic feasibility of SMRs in the United States.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

A Systematic Framework for Projecting the Future Cost of Offshore Wind Energy

Offshore wind costs are expected to decline rapidly in the short and medium term future as the industry grows and gains experience in manufacturing, installing, and operating commercial scale projects. Estimating the future costs of offshore wind energy is critical for evaluating the technology's economic performance, how it can fit into a broader clean energy economy, and how R&D investment can be allocated to advance the technology. We present a newly developed approach for forecasting these costs which focuses on an empirically-derived learning rate for capital costs and prescribed cost and performance improvements for operational costs and capacity factor. We establish baseline costs for a series of reference fixed-bottom and floating projects in 2021 and project cost trajectories to 2035, presenting both an average cost trajectory as well as describing the range of potential future costs associated with site-specific cost variations and uncertainty in the estimate of the learning rate. We also conduct sensitivity analyses showing the impact of different global deployments by 2035 and variations in the prescribed operational costs and capacity factors. The results show that fixed-bottom and floating offshore wind capital costs could decrease to around $\$$2,400/kW and $\$$3,300/kW by 2035, respectively, with ranges of $\$$2,100/kW - $\$$2,750/kW for fixed-bottom projects and $\$$2,850/kW - $\$$5,500/kW for floating projects. The levelized cost of energy of fixed-bottom and floating wind projects could decrease to $\$$53.1/MWh and $\$$63.9/MWh by 2035, with ranges of $\$$48.4/MWh - $\$$59.7/MWh for fixed-bottom projects and $\$$46.5/MWh - $\$$99.9/MWh for floating projects. By presenting the uncertainty associated with the forecast we provide a transparent description of the spectrum of potential cost trajectories for offshore wind.

17 WIND ENERGY↗

Cycle Evaluations of Reversible Chemical Reactions for Solar Thermochemical Energy Storage in Support of Concentrating Solar Power Generation Systems

The production and storage of thermochemical energy is a possible route to increase capacity factors and reduce the Levelized Cost of Electricity from concentrated solar power generation systems. In this paper, we present the results of cycle evaluations for various thermochemical cycles, including a well-documented ammonia closed-cycle along with open- and closed-cycle versions of hydrocarbon chemical reactions. Among the available reversible hydrocarbon chemical reactions, catalytic reforming-methanation cycles are considered; specifically, various methane-steam reforming cycles are compared to the ammonia cycle. In some cases, the production of an intermediate chemical, methanol, is also included with some benefit being realized. The best case, based on overall power generation efficiency and overall plant capacity factor, was found to be an open cycle including methane-steam reforming, using concentrated solar energy to increase the chemical energy content of the reacting stream, followed by combustion to generate heat for the heat engine.

10 SYNTHETIC FUELS↗

Development of a High-Concentration, Low-Cost Parabolic Trough System for Baseload CSP Generation (Phase II Final Report)

The SkyTrough DSP will advance the state-of-the-art in parabolic troughs for utility applications, with a larger aperture, higher operating temperature, and lower cost. The goal of this project was to develop a parabolic trough collector that enables solar electricity generation in the 2020 marketplace for a 216MWe nameplate baseload power plant. This plant requires an LCOE of 9¢/kWhe, given a capacity factor of 75%, a fossil fuel limit of 15%, a fossil fuel cost of $\$$6.75/MMBtu, $\$$25.00/kWht thermal storage cost, and a domestic installation corresponding to Daggett, CA. The result of our optimization was a trough design of larger aperture and operating temperature than has been fielded in large, utility scale parabolic trough applications: 7.6m width x 150m SCA length (1,118m 2 aperture), with four 90mm diameter × 4.7m receivers per mirror module and an operating temperature of 500°C. The results from physical modeling in the System Advisory Model indicate that, for a capacity factor of 75%: The LCOE will be 8.87¢/kWhe. SkyFuel examined the design of almost every parabolic trough component from a perspective of load and performance at aperture areas from 500 to 2,900m 2 . Aperture-dependent design was combined with fixed quotations for similar parts from the commercialized SkyTrough product, and established an installed cost of $\$$130/m 2 in 2020. This project was conducted in two phases. Phase I was a preliminary design, culminating in an optimum trough size and further improvement of an advanced polymeric reflective material. This phase was completed in October of 2011. Phase II has been the detailed engineering design and component testing, which culminated in the fabrication and testing of a single mirror module. Phase II is complete, and this document presents a summary of the comprehensive work.

14 SOLAR ENERGY↗

Conceptual Design of Pulverized Coal Electricity Generating Units for Flexible Operation

This National Energy Technology Laboratory (NETL) study addresses the conceptual design of greenfield pulverized coal (PC) plants intended for flexible rather than high capacity factor baseload operation. The United States has plentiful, low-cost natural gas resources - studies of aggressive decarbonization scenarios of the US energy sector suggest that the variability of carbon-free power can be economically addressed using dispatchable natural gas-fueled generation. Globally, natural gas resources are not as plentiful or low cost; consequently, some regions of the world are anticipated to continue to rely upon coal generation, even as they pursue decarbonization efforts. To support the increased utilization of variable renewable generation in these coal-dependent regions, plant designs must target low-capacity factor coal plants with increased emphasis on flexibility attributes such as start-up times, ramp rates, minimum load, and part-load heat rates. While much work has been performed on the improvement of the flexibility for existing coal plants originally designed for baseload service, little public literature exists on clean sheet design for flexible operation. This conceptual design study aims to define the features, performance characteristics, and costs for greenfield coal plants intended for flexible operation. Quantifying these characteristics provides critical information required by utility owners, grid planners, energy market modelers, and energy policy decision makers in coal-dependent regions of the world to better understand how coal-fired power plants can support a transition to low carbon generation.

20 FOSSIL-FUELED POWER PLANTS↗

The Potential Role of Concentrating Solar Power within the Context of DOE's 2030 Solar Cost Targets

For solar electricity generating technologies to be cost competitive at a large scale with conventionally generated electricity, cost reductions are needed for both concentrating solar power (CSP) and solar photovoltaic (PV) systems. In 2011, the U.S. Department of Energy (DOE) established solar cost targets that corresponded to reducing CSP and PV prices by approximately 75% in order to achieve a levelized cost of electricity (LCOE) of $0.06 per kilowatt-hour (kWh) for both utility-scale PV and high-capacity factor CSP-TES systems in 2020. Utility-scale PV achieved its 2020 cost target in 2017, and recent estimates for the LCOE of CSP-TES with a molten-salt power tower system are approximately $0.10/kWh for projects that are expected to come online in 2020, which represents a substantial reduction since 2010 - when the LCOE for CSP-TES was around $0.21/kWh. To continue the momentum for cost reductions in solar technologies, DOE recently established cost targets for 2030 that would make solar one of the lowest-cost sources of new electricity in the United States. For CSP-based systems, the new targets correspond to an LCOE in 2030 of $0.05/kWh for a dispatchable, high-capacity factor CSP-TES plant configuration. This aggressive target would have been unimaginable a decade ago. However, building on the previously described reduction in CSP-TES costs over the past decade, recent announcements suggest the next phase of projects will continue this downward trend through lower installation costs, attractive financing, longer-duration PPAs, and the ability to capitalize on the value that the flexibility of storage brings CSP. This presentation summarizes a recent report that evaluates the potential impacts of simultaneously achieving the 2030 cost targets for PV and CSP-TES, and it includes a detailed evaluation of the role that CSP-TES could play in realizing those impacts. The scenarios in this analysis are designed to isolate and assess the potential impacts of achieving DOE's 2030 cost targets for CSP-TES and PV, and they do not reflect the potential benefits or system impacts associated with success in other DOE research programs. The low-cost solar scenarios include DOE's 2030 solar cost targets--which are represented via a roughly 50% reduction in LCOE by 2030 (from current levels) with additional cost reductions thereafter representing technology learning and/or improvements that could result from innovation - coupled with a variety of market, technology, and demand assumptions. With these assumptions, the evolution of the contiguous U.S. electricity system is evaluated with NREL's Renewable Energy Deployment System (ReEDS) model, which was specifically designed to represent the temporal and locational value of renewable generation technologies in the U.S. power system. ReEDS relies on system-wide least-cost optimization to estimate the type and location of future generation and transmission capacity. In addition, it accounts for the locational and temporal variations in variable renewable technologies, including the need for new transmission, curtailment, dynamic capacity value, and the need to hold operating reserves to account for the uncertainty and variability of these technologies. This presentation summarizes the key findings that arise from a detailed evaluation of the impacts of achieving DOE's 2030 cost targets for CSP-TES and PV systems, noting again the inherent challenges associated with modeling future scenarios of the large, complex system electricity system in the contiguous United States within the context of various market features.

14 SOLAR ENERGY↗

Development of Methodologies for Technology Deployment for Advanced Outage Control Centers that Improve Outage Coordination, Problem Resolution and Outage Risk Management

This research effort is a part of the Light-Water Reactor Sustainability (LWRS) Program, which is a research and development (R&D) program sponsored by Department of Energy (DOE) and performed in close collaboration with industry R&D programs that provides the technical foundations for licensing and managing the long-term, safe, and economical operation of current nuclear power plants. The LWRS program serves to help the U.S. nuclear industry adopt new technologies and engineering solutions that facilitate the continued safe operation of the plants and extension of the current operating licenses. The long term viability of existing nuclear power plants in the U.S. will depend upon maintaining high capacity factors, avoiding nuclear safety issues and reducing operating costs. The slow progress in the construction on new nuclear power plants has placed in increased importance on maintaining the output of the current fleet of nuclear power plants. Recently expanded natural gas production has placed increased economic pressure on nuclear power plants due to lower cost competition. Until recently, power uprate projects had steadily increased the total output of the U.S. nuclear fleet. Errors made during power plant upgrade projects have now removed three nuclear power plants from the U.S. fleet and economic considerations have caused the permanent shutdown of a fourth plant. Additionally, several utilities have cancelled power uprate projects citing economic concerns. For the past several years net electrical generation from U.S. nuclear power plants has been declining. One of few remaining areas where significant improvements in plant capacity factors can be made is in minimizing the duration of refueling outages. Managing nuclear power plant outages is a complex and difficult task. Due to the large number of complex tasks and the uncertainty that accompanies them, outage durations routinely exceed the planned duration. The ability to complete an outage on or near schedule depends upon the performance of the outage management organization. During an outage, the outage control center (OCC) is the temporary command center for outage managers and provides several critical functions for the successful execution of the outage schedule. Essentially, the OCC functions to facilitate information inflow, assist outage management in processing information and to facilitate the dissemination of information to stakeholders. Currently, outage management activities primarily rely on telephone communication, face to face reports of status and periodic briefings in the OCC. Much of the information displayed in OCCs is static and out of date requiring an evaluation to determine if it is still valid. Several advanced communication and collaboration technologies have shown promise for facilitating the information flow into, across and out of the OCC. Additionally, advances in the areas of mobile worker technologies, computer based procedures and electronic work packages can be leveraged to improve the availability of real time status to outage managers.

99 GENERAL AND MISCELLANEOUS↗

Adaptive Stiffness Power Take-Off System for a Hydraulic Hose-Pump Point Absorber Wave Energy Converter

Two crucial challenges faced in the design of ocean wave energy converters (WECs) are maintaining high capacity factors and remaining robust in everchanging, harsh ocean environments. This study introduces a novel mechanism for achieving reactive WEC control with a soft hydraulic power take-off, thereby addressing both challenges. The device of interest involves a hydraulic pump, constructed from a fluidic flexible matrix composite (F2MC), which is cyclically stretched by driving waves and pressurizes working fluid through a turbine-generator. This class of fiber-reinforced stretch hoses is established for ocean use as robust moorings and shock absorbers. The dynamic properties of the F2MC pump depend on internal pressure, which can be controlled by a continuously variable transmission between the turbine and generator, allowing the system to be adapted for better performance over a wide range of wave conditions. This work presents a dynamic model for operation and adaptive behavior of this power take-off system, experimentally validates components of the model, and performs dynamic simulations of the system that show increases in power production and capacity factor compared to non-adaptive operation for a variety of driving wave conditions. This work develops the basis for future large-scale experimental testing and controller design of this system.

Wave energy conversion, fluidic flexible matrix co↗

Energy Storage Analysis

This study presents a comprehensive techno-economic characterization of energy storage and exible low carbon power generation technologies that can shift energy across days, weeks, or months to balance daily, weekly, and seasonal disparities in supply and demand. Energy storage technologies evaluated here include pumped hydropower storage (PHS), adiabatic and diabatic compressed air energy storage (CAES), vanadium redox flow batteries (VRBs), pumped thermal energy storage (P-TES), and renewably produced hydrogen stored in either geologic formations or underground pipes with re-electrification via combustion turbines in combined cycles, stationary proton exchange membrane (PEM) fuel cells, or the novel use of PEM fuel cells designed for heavy-duty vehicles (HDVs) which are expected to have shorter lives but also lower capital costs. We also evaluate flexible low-carbon power generation systems, including ethanol combustion in gas turbines and natural gas combustion with carbon capture and sequestration (CCS). We estimate current costs with literature data, use learning rates to characterize future costs, and develop capacity factors calibrated to an 85% renewables grid to calculate the levelized cost of energy (LCOE) of each technology. Results illustrate that at the 12-hour storage duration, PHS and CAES have the lowest LCOE with current costs, and VRBs become competitive if future costs are achieved. At the 120-hour storage duration, hydrogen systems with geologic storage and natural gas with CCS achieve the lowest LCOE in both current and future capital cost scenarios. In particular, the new configuration of HDV-PEM fuel cells with hydrogen storage in geologic formations evaluated here could lower the LCOE by 22-27% compared to stationary fuel cell systems typically evaluated and might help enable very high (>80%) renewable energy electric power systems. P-TES and hydrogen stored in underground pipes are the least-cost options at the 120-hour storage duration rating that do not require some form of geologic storage. Sensitivity analysis and Monte Carlo analysis illustrate that the general trends seen in this study are valid for a wide range of capacity factors and future cost scenarios. The study also illustrates that coproducing and selling hydrogen to other markets could reduce the LCOE of hydrogen systems by up to 39%.

carbon capture and sequestration↗