Autoregulation of cerebral blood flow in orthostatic hypotension

BACKGROUND AND PURPOSE: We sought to evaluate cerebral autoregulation in patients with orthostatic hypotension (OH). METHODS: We studied 21 patients (aged 52 to 78 years) with neurogenic OH during 80 degrees head-up tilt. Blood flow velocities (BFV) from the middle cerebral artery were continuously monitored with transcranial Doppler sonography, as were heart rate, blood pressure (BP), cardiac output, stroke volume, CO2, total peripheral resistance, and cerebrovascular resistance. RESULTS: All OH patients had lower BP (P<.0001), BFV_diastolic (P<.05), CVR (P<.007), and TPR (P<.02) during head-up tilt than control subjects. In control subjects, no correlations between BFV and BP were found during head-up tilt, suggesting normal autoregulation. OH patients could be separated into those with normal or expanded autoregulation (OH_NA; n=16) and those with autoregulatory failure (OH_AF; n=5). The OH_NA group showed either no correlation between BFV and BP (n=8) or had a positive BFV/BP correlation (R2>.75) but with a flat slope. An expansion of the "autoregulated" range was seen in some patients. The OH_AF group was characterized by a profound fall in BFV in response to a small reduction in BP (mean deltaBP <40 mm Hg; R2>.75). CONCLUSIONS: The most common patterns of cerebral response to OH are autoregulatory failure with a flat flow-pressure relationship or intact autoregulation with an expanded autoregulated range. The least common pattern is autoregulatory failure with a steep flow-pressure relationship. Patients with patterns 1 and 2 have an enhanced capacity to cope with OH, while those with pattern 3 have reduced capacity.

Non-NASA Center↗

Intrapericardial denervation - Radial artery blood flow and heart rate responses to LBNP

The effects of intrapericardial denervation on the radial artery blood flow velocity (RABFV) and heart rate (HR) responses to LBNP in rhesus monkeys were investigated by measuring the RABFV transcutaneously by a continuous-wave Doppler ultrasonic flowmeter in order to derive an index of forearm blood flow response to low (0 to -20 mm Hg) and high (0 to -60 mm Hg) ramp exposures during supine LBNP. Four of the eight subjects were subjected to efferent and afferent cardiac denervation. It was found that, during low levels of LBNP, monkeys with cardiac denervation exhibited no cardiopulmonary baroreceptor-mediated change in the RABFV or HR, unlike the intact animals, which showed steady decreases in RABFV during both high- and low-pressure protocols. It is suggested that forearm blood flow and HR responses to low-level LBNP, along with pharmacological challenge, are viable physiological tests for verifying the completeness of atrial and cardiopulmonary baroreceptor denervation.

Mckeever, Kenneth H.↗

Cardiovascular Adaptations to Long Duration Head-Down Tilt Bed Rest

INTRODUCTION: Orthostatic hypotension is a serious risk for crewmembers returning from spaceflight. Numerous cardiovascular mechanisms have been proposed to account for this problem, including vascular and cardiac dysfunction, which we studied during bed rest. METHODS: Thirteen subjects were studied before and during bed rest. Statistical analysis was limited to the first 49-60 days of bed rest, and compared to pre-bed rest data. Ultrasound data were collected on vascular and cardiac structure and function. Tilt testing was conducted for 30 minutes or until presyncopal symptoms intervened. RESULTS: Plasma volume was significantly reduced by day 7 of bed rest. Flow-mediated dilation in the leg was significantly increased at bed rest day 49. Arterial responses to nitroglycerin differed in the arm and leg, but did not change as a result of bed rest. Intimal-medial thickness markedly decreased at bed rest days 21, 35 and 49. Several cardiac functional parameters including isovolumic relaxation time, ejection time and myocardial performance index were significantly increased (indicating a decrease in cardiac function) during bed rest. There was a trend for decreased orthostatic tolerance following 60 days of bed rest. DISCUSSION: These data suggest that 6 head-down tilt bed rest alters cardiovascular structure and function in a pattern similar to short duration spaceflight. Additionally, the vascular alterations are primarily seen in the lower body, while vessels of the upper body are unaffected. KEY WORDS: spaceflight, orthostatic intolerance, hypotension, fluid-shift, plasma volume

Platts, Steven H.↗

Physiologic Pressure and Flow Changes During Parabolic Flight (Pilot Study)

The objective of this study was to obtain measurement of cutaneous tissue perfusion central and peripheral venous pressure, and esophageal and abdominal pressure in human test subjects during parabolic flight. Hemodynamic data recorded during SLS-I and SLS-2 missions have resulted in the paradoxical finding of increased cardiac stroke volume in the presence of a decreased central venous pressure (CVP) following entry in weightlessness. The investigators have proposed that in the absence of gravity, acceleration-induced peripheral vascular compression is relieved, increasing peripheral vascular capacity and flow while reducing central and peripheral venous pressure, This pilot study seeks to measure blood pressure and flow in human test subjects during parabolic flight for different postures.

Pantalos, George↗

Augmented catecholamine uptake by the heart during hemorrhage in the conscious dog

Changes in arterial and coronary sinus concentrations of norepinephrine (NE) and epinephrine (E) in response to hemorrhage were examined in conscious dogs. Hemorrhage (45 +/- 3.2 ml/kg) decreased mean arterial pressure by 47 +/- 6%, left ventricular (LV) dP/dt by 38 +/- 6%, and mean left circumflex coronary blood flow by 47 +/- 6%, while heart rate increased by 44 +/- 13%. Increases in concentrations of arterial NE (5,050 +/- 1,080 from 190 +/- 20 pg/ml) and E (12,700 +/- 3,280 from 110 +/- 20 pg/ml) were far greater than increases in coronary sinus NE (1,700 +/- 780 from 270 +/- 50 pg/ml) and E (4,300 +/- 2,590 from 90 +/- 10 pg/ml). Net release of NE from the heart at rest was converted to a fractional extraction of 66 +/- 9% after hemorrhage. Fractional extraction of E increased from 16 +/- 6% at rest to 73 +/- 8% after hemorrhage. In cardiac-denervated dogs, hemorrhage (46 +/- 2.8 ml/kg) decreased mean arterial pressure by 39 +/- 15%, LV dP/dt by 36 +/- 10%, and mean left circumflex coronary blood flow by 36 +/- 13%, while heart rate increased by 24 +/- 10%. Hemorrhage increased arterial NE (1,740 +/- 150 from 210 +/- 30 pg/ml) and E (3,050 +/- 880 from 140 +/- 20 pg/ml) more than it increased coronary sinus NE (460 +/- 50 from 150 +/- 30 pg/ml) and E (660 +/- 160 from 90 +/- 20 pg/ml) but significantly less (P less than 0.05) than observed in intact dogs. These experiments indicate that hemorrhage, unlike exercise and sympathetic nerve stimulation, does not induce net overflow of NE from the heart.(ABSTRACT TRUNCATED AT 250 WORDS).

Non-NASA Center↗

Importance of the splanchnic vascular bed in human blood pressure regulation.

Three-part experiment in which five subjects were exposed to lower body negative pressure (LBNP) at -50 mm Hg below the iliac crests. Duration of LBNP to earliest vagal symptoms was 7 to 21 min; all data are expressed as changes from control period to the last measurements before these symptoms. In part I, forearm blood flow (by Whitney gauge) fell 45% during LBNP. In part II, splanchnic blood flow (from arterial clearance hepatic extraction of indocyanine green) fell 32% and splanchnic vascular resistance rose 30%. In part III, cardiac output fell 28%, stroke volume 51%, and central blood volume 21%. Total peripheral resistance and heart rate rose 19% and 52%. Of the reduction in total vascular conductance, decreased splanchnic conductance accounted for approximately 33%; skin plus muscle conductance decreased similarly.

Rowell, L. B.↗

Cardiovascular adaptation to O-G (Experiment 294) - Instrumentation for invasive and noninvasive studies

Many astronauts returning from space have difficulties regulating blood pressure, some to the point of fainting during quiet standing. Experiment 294 was designed to study this and other cardiovascular effects of adaptation to microgravity and to understand the mechanisms behind it. To accomplish this several cardiovascular variables had to be measured accurately. Heart rate, blood pressure, cardiac output (blood pumped by the heart each minute), stroke volume (blood pumped by the heart with each beat), limb flow, limb compliance, heart size and central venous pressure all had to been recorded during various stresses to understand fully the adaptation to space and the readaptation to earth's gravity. Numerous pieces of equipment were used. Some were purpose-built for the Spacelab mission and others were derived from commercial hardware. Developing spaceflight hardware is challenging and costly, but can lead to significant new information in the unique environment of space.

Buckey, Jay C.↗

Cardiovascular consequences of bed rest: effect on maximal oxygen uptake

Maximal oxygen uptake (VO2max) is reduced in healthy individuals confined to bed rest, suggesting it is independent of any disease state. The magnitude of reduction in VO2max is dependent on duration of bed rest and the initial level of aerobic fitness (VO2max), but it appears to be independent of age or gender. Bed rest induces an elevated maximal heart rate which, in turn, is associated with decreased cardiac vagal tone, increased sympathetic catecholamine secretion, and greater cardiac beta-receptor sensitivity. Despite the elevation in heart rate, VO2max is reduced primarily from decreased maximal stroke volume and cardiac output. An elevated ejection fraction during exercise following bed rest suggests that the lower stroke volume is not caused by ventricular dysfunction but is primarily the result of decreased venous return associated with lower circulating blood volume, reduced central venous pressure, and higher venous compliance in the lower extremities. VO2max, stroke volume, and cardiac output are further compromised by exercise in the upright posture. The contribution of hypovolemia to reduced cardiac output during exercise following bed rest is supported by the close relationship between the relative magnitude (% delta) and time course of change in blood volume and VO2max during bed rest, and also by the fact that retention of plasma volume is associated with maintenance of VO2max after bed rest. Arteriovenous oxygen difference during maximal exercise is not altered by bed rest, suggesting that peripheral mechanisms may not contribute significantly to the decreased VO2max. However reduction in baseline and maximal muscle blood flow, red blood cell volume, and capillarization in working muscles represent peripheral mechanisms that may contribute to limited oxygen delivery and, subsequently, lowered VO2max. Thus, alterations in cardiac and vascular functions induced by prolonged confinement to bed rest contribute to diminution of maximal oxygen uptake and reserve capacity to perform physical work.

Non-NASA Center↗

Left ventricular outflow tract mean systolic acceleration as a surrogate for the slope of the left ventricular end-systolic pressure-volume relationship

OBJECTIVE: The goal of this study was to analyze left ventricular outflow tract systolic acceleration (LVOT(Acc)) during alterations in left ventricular (LV) contractility and LV filling. BACKGROUND: Most indexes described to quantify LV systolic function, such as LV ejection fraction and cardiac output, are dependent on loading conditions. METHODS: In 18 sheep (4 normal, 6 with aortic regurgitation, and 8 with old myocardial infarction), blood flow velocities through the LVOT were recorded using conventional pulsed Doppler. The LVOT(Acc) was calculated as the aortic peak velocity divided by the time to peak flow; LVOT(Acc) was compared with LV maximal elastance (E(m)) acquired by conductance catheter under different loading conditions, including volume and pressure overload during an acute coronary occlusion (n = 10). In addition, a clinically validated lumped-parameter numerical model of the cardiovascular system was used to support our findings. RESULTS: Left ventricular E(m) and LVOT(Acc) decreased during ischemia (1.67 +/- 0.67 mm Hg.ml(-1) before vs. 0.93 +/- 0.41 mm Hg.ml(-1) during acute coronary occlusion [p < 0.05] and 7.9 +/- 3.1 m.s(-2) before vs. 4.4 +/- 1.0 m.s(-2) during coronary occlusion [p < 0.05], respectively). Left ventricular outflow tract systolic acceleration showed a strong linear correlation with LV E(m) (y = 3.84x + 1.87, r = 0.85, p < 0.001). Similar findings were obtained with the numerical modeling, which demonstrated a strong correlation between predicted and actual LV E(m) (predicted = 0.98 [actual] -0.01, r = 0.86). By analysis of variance, there was no statistically significant difference in LVOT(Acc) under different loading conditions. CONCLUSIONS: For a variety of hemodynamic conditions, LVOT(Acc) was linearly related to the LV contractility index LV E(m) and was independent of loading conditions. These findings were consistent with numerical modeling. Thus, this Doppler index may serve as a good noninvasive index of LV contractility.

Non-NASA Center↗

Spatial distribution of pulmonary blood flow in dogs in increased force environments

Spatial distribution of pulmonary blood flow during 2- to 3-min exposures to 6-8 Gy acceleration was studied, using radioactive microspheres in dogs, and compared to previously reported 1 Gy control distributions. Isotope distributions were measured by scintiscanning individual 1-cm-thick cross sections of excised, fixed lungs. Results indicate: (1) the fraction of cardiac output traversing left and right lungs did not change systematically with the duration and magnitude of acceleration; but (2) the fraction is strongly affected by the occurrence or absence of fast deep breaths, which cause an increase or decrease, respectively, in blood flow through the dependent lung; and (3) Gy acceleration caused a significant increase in relative pulmonary vascular resistance (PVR) in nondependent and dependent regions of the lung concurrent with a decrease in PVR in the midsagittal region of the thorax.

Greenleaf, J. F.↗

Effects of acute hypoxia on cardiopulmonary responses to head-down tilt

Six male subjects were exposed on two separate occasions to simulated microgravity with 28 deg head-down tilt (HD) for 1 h with baseline followed by recovery at + 17 deg head-up. Pulmonary ventilation, gas exchange, spirometry, and central and cerebral blood flow characteristics were compared while breathing ambient air and reduced F(I)O2 equivalent to 14,828 ft. With hypoxia (HY), the increased tidal volume served to attenuate the drop in arterial saturation by reducing deadspace ventilation. Arterial and mixed venous PO2, values, estimated from peripheral venous samples and cardiac output (CO), were both maintained during HD in HY. Mixed venous PO2 was elevated by an increase in CO associated with a reduction in systemic resistance. Changes in spirometric indices during HD were not accentuated by HY, making the presence of interstitial edema unlikely. Cerebral flow and resistance showed minor reductions with HD. Tissue oxygenation and cardiopulmonary function were not notably effected by HD during HY, but a combination of these two stressors may predispose subjects to subsequent orthostatic intolerance during initial recovery.

Loeppky, J. A.↗

Ultraminiature manometer-tipped cardiac catheter

Miniature diaphragm-type capacitance transducer capable of being mounted on the end of a cardiac catheter has been developed for measurement of intravascular pressures. The transducer can be inserted in small ducts /arteries and veins/ without disturbing the flow characteristics. It is very useful for making measurements in babies.

Coon, G. W.↗

Effects of 12 days exposure to simulated microgravity on central circulatory hemodynamics in the rhesus monkey

Central circulatory hemodynamic responses were measured before and during the initial 9 days of a 12-day 10 degrees head-down tilt (HDT) in 4 flight-sized juvenile rhesus monkeys who were surgically instrumented with a variety of intrathoracic catheters and blood flow sensors to assess the effects of simulated microgravity on central circulatory hemodynamics. Each subject underwent measurements of aortic and left ventricular pressures, and aortic flow before and during HDT as well as during a passive head-up postural test before and after HDT. Heart rate, stroke volume, cardiac output, and left ventricular end-diastolic pressure were measured, and dP/dt and left ventricular elastance was calculated from hemodynamic measurements. The postural test consisted of 5 min of supine baseline control followed by 5 minutes of 90 degrees upright tilt (HUT). Heart rate, stroke volume, cardiac output, and left ventricular end-diastolic pressure showed no consistent alterations during HDT. Left ventricular elastance was reduced in all animals throughout HDT, indicating that cardiac compliance was increased. HDT did not consistently alter left ventricular +dP/dt, indicating no change in cardiac contractility. Heart rate during the post-HDT HUT postural test was elevated compared to pre-HDT while post-HDT cardiac output was decreased by 52% as a result of a 54% reduction in stroke volume throughout HUT. Results from this study using an instrumented rhesus monkey suggest that exposure to microgravity may increase ventricular compliance without alternating cardiac contractility. Our project supported the notion that an invasively-instrumented animal model should be viable for use in spaceflight cardiovascular experiments to assess potential changes in myocardial function and cardiac compliance.

NASA Discipline Cardiopulmonary↗

Defining the Relationship between Biomarkers of Oxidative and Inflammatory Stress and the Risk for Atherosclerosis in Astronauts during and after Long-duration Spaceflight

Future human space travel will consist primarily of long-duration missions onboard the International Space Station (ISS) or exploration-class missions to Mars, its moons, or nearby asteroids. These missions will expose astronauts to increased risk of oxidative and inflammatory damage from a variety of sources, including radiation, psychological stress, reduced physical activity, diminished nutritional status, and hyperoxic exposure during extravehicular activity. Evidence exists that increased oxidative damage and inflammation can accelerate the development of atherosclerosis. PURPOSE The purpose of this investigation is to determine whether biomarkers of oxidative and inflammatory stress are elevated during and after long-duration spaceflight and investigate if a relation exists between levels of these biomarkers and structural and functional indices of atherosclerotic risk measured in the carotid and brachial arteries. This is the first study to propose assessing atherosclerotic risk using biochemical, structural, and functional measures before, during, and immediately after spaceflight, and structural and functional measures for up to 5 years after landing. METHODS We will study 12 astronauts before, during, and up to 5 years after long-duration ISS missions. A panel of biomarkers of oxidative and inflammatory stress will be measured twice before flight, early (flight days 15 and 60) and late (2 weeks before landing) during the mission, and early in the postflight recovery phase (approx 3 days after landing). Arterial structure and vascular compliance will be measured at the same times and also at 1, 3, and 5 years after landing (surveillance). Arterial function will be measured using the same preflight, postflight, and surveillance schedule as arterial structure and vascular compliance measures, but will not be measured inflight. Biomarkers, some of which we have previously shown to be elevated with spaceflight, will be measured in venous blood samples and 24-h (in-flight) and 48-h (pre- and post-flight) urine pools. Arterial structure will be assessed from measures of carotid intima-media thickness, which have been shown to be better indicators of atherosclerotic than the Framingham Risk Score. Arterial function will be assessed using brachial flow-mediated dilation, a well-validated measure used to assess endothelium-dependent vasodilation and is a sensitive predictor of atherosclerotic risk. Arterial pulse pressure measured in the brachial artery and stroke volume measured from cardiac ultrasound will be used to assess hemodynamic status, cardiac function, and systemic vascular compliance. Three astronauts are actively participating in the preflight data collection and training activities. One astronaut has completed all preflight activities and will participate in the first in-flight data collection sessions by the end of 2013. The first post-flight data collection sessions will occur in the spring of 2014. EXPECTED RESULTS We hypothesize that biomarkers of oxidative and inflammatory stress will increased with spaceflight and will correlate with increased carotid intima-media thickness during and after flight and with decreased flow-mediated dilation after the mission. Furthermore, we hypothesize that measures of oxidative stress will return to baseline after flight, but biomarkers of inflammatory stress and vascular indices of atherosclerotic risk will remain elevated.

Lee, Stuart M. C.↗

Implantable telemetry for small animals

A series of totally implantable telemetry devices for use in measuring deep body parameters in small animals were developed. Under a collaborative agreement with NASA, several of these systems; the continuous wave Doppler ultrasonic flowmeter, the multichannel telemetry system, and the inductively-powered dual channel cardiac pacer were evaluated in a series of ten mongrel dogs (15 to 20 kg.). These systems were used to measure ascending aortic and coronary blood flow, aortic pressure, and subcutaneous EKG.

Source record↗

Noninvasive assessment of mitral inertness: clinical results with numerical model validation

Inertial forces (Mdv/dt) are a significant component of transmitral flow, but cannot be measured with Doppler echo. We validated a method of estimating Mdv/dt. Ten patients had a dual sensor transmitral (TM) catheter placed during cardiac surgery. Doppler and 2D echo was performed while acquiring LA and LV pressures. Mdv/dt was determined from the Bernoulli equation using Doppler velocities and TM gradients. Results were compared with numerical modeling. TM gradients (range: 1.04-14.24 mmHg) consisted of 74.0 +/- 11.0% inertial forcers (range: 0.6-12.9 mmHg). Multivariate analysis predicted Mdv/dt = -4.171(S/D (RATIO)) + 0.063(LAvolume-max) + 5. Using this equation, a strong relationship was obtained for the clinical dataset (y=0.98x - 0.045, r=0.90) and the results of numerical modeling (y=0.96x - 0.16, r=0.84). TM gradients are mainly inertial and, as validated by modeling, can be estimated with echocardiography.

NASA Discipline Cardiopulmonary↗

Hypergravity Alters the Susceptibility of Cells to Anoxia-Reoxygenation Injury

Gravity is a physical force, much like shear stress or mechanical stretch, and should affect organ and cellular function. Researchers have shown that gravity plays a role in ventilation and blood flow distribution, gas exchange, alveolar size and mechanical stresses within the lung. Short exposure to microgravity produced marked alterations in lung blood flow and ventilation distribution while hypergravity exaggerated the regional differences in lung structure and function resulting in reduced ventilation at the base and no ventilation of the upper half of the lung. Microgravity also decreased metabolic activity in cardiac cells, WI-38 embryonic lung cells, and human lymphocytes. Rats, in the tail-suspended head-down tilt model, experienced transient loss of lung water, contrary to an expected increase due to pooling of blood in the pulmonary vasculature. Hypergravity has also been found to increase the proliferation of several different cell lines (e.g., chick embryo fibroblasts) while decreasing cell motility and slowing liver regeneration following partial hepatectomy. These studies show that changes in the gravity environment will affect several aspects of organ and cellular function and produce major change in blood flow and tissue/organ perfusion. However, these past studies have not addressed whether ischemia-reperfusion injury will be exacerbated or ameliorated by changes in the gravity environment, e.g., space flight. Currently, nothing is known about how gravity will affect the susceptibility of different lung and vascular cells to this type of injury. We conducted studies that addressed the following question: Does the susceptibility of lung fibroblasts, vascular smooth muscle, and endothelial cells to anoxia/reoxygenation injury change following exposure to hypergravity conditions?

McCloud, Henry↗

Hindlimb unweighting affects rat vascular capacitance function

Microgravity is associated with an impaired stroke volume and, therefore, cardiac output response to orthostatic stress. We hypothesized that a decreased venous filling pressure due to increased venous compliance may be an important contributing factor in this response. We used a constant flow, constant right atrial pressure cardiopulmonary bypass procedure to measure total systemic vascular compliance (C(T)), arterial compliance (C(A)), and venous compliance (C(V)) in seven control and seven 21-day hindlimb unweighted (HLU) rats. These compliance values were calculated under baseline conditions and during an infusion of 0.2 microg*kg(-1)*min(-1) norepinephrine (NE). The change in reservoir volume, which reflects changes in unstressed vascular volume (DeltaV(0)) that occurred upon infusion of NE, was also measured. C(T) and C(V) were larger in HLU rats both at baseline and during the NE infusion (P < 0.05). Infusion of NE decreased C(T) and C(V) by ~20% in both HLU and control rats (P < 0.01). C(A) was also significantly decreased in both groups of rats by NE (P < 0.01), but values of C(A) were similar between HLU and control rats both at baseline and during the NE infusion. Additionally, the NE-induced DeltaV(0) was attenuated by 53% in HLU rats compared with control rats (P < 0.05). The larger C(V) and attenuated DeltaV(0) in HLU rats could contribute to a decreased filling pressure during orthostasis and thus may partially underlie the mechanism leading to the exaggerated fall in stroke volume and cardiac output seen in astronauts during an orthostatic stress after exposure to microgravity.