Search NASA⌕ Search

SEARCH · Search NASA

Results for “Cardiac flow”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Importance of the splanchnic vascular bed in human blood pressure regulation.

Three-part experiment in which five subjects were exposed to lower body negative pressure (LBNP) at -50 mm Hg below the iliac crests. Duration of LBNP to earliest vagal symptoms was 7 to 21 min; all data are expressed as changes from control period to the last measurements before these symptoms. In part I, forearm blood flow (by Whitney gauge) fell 45% during LBNP. In part II, splanchnic blood flow (from arterial clearance hepatic extraction of indocyanine green) fell 32% and splanchnic vascular resistance rose 30%. In part III, cardiac output fell 28%, stroke volume 51%, and central blood volume 21%. Total peripheral resistance and heart rate rose 19% and 52%. Of the reduction in total vascular conductance, decreased splanchnic conductance accounted for approximately 33%; skin plus muscle conductance decreased similarly.

Rowell, L. B.↗

Cardiovascular adaptation to O-G (Experiment 294) - Instrumentation for invasive and noninvasive studies

Many astronauts returning from space have difficulties regulating blood pressure, some to the point of fainting during quiet standing. Experiment 294 was designed to study this and other cardiovascular effects of adaptation to microgravity and to understand the mechanisms behind it. To accomplish this several cardiovascular variables had to be measured accurately. Heart rate, blood pressure, cardiac output (blood pumped by the heart each minute), stroke volume (blood pumped by the heart with each beat), limb flow, limb compliance, heart size and central venous pressure all had to been recorded during various stresses to understand fully the adaptation to space and the readaptation to earth's gravity. Numerous pieces of equipment were used. Some were purpose-built for the Spacelab mission and others were derived from commercial hardware. Developing spaceflight hardware is challenging and costly, but can lead to significant new information in the unique environment of space.

Buckey, Jay C.↗

Cardiovascular consequences of bed rest: effect on maximal oxygen uptake

Maximal oxygen uptake (VO2max) is reduced in healthy individuals confined to bed rest, suggesting it is independent of any disease state. The magnitude of reduction in VO2max is dependent on duration of bed rest and the initial level of aerobic fitness (VO2max), but it appears to be independent of age or gender. Bed rest induces an elevated maximal heart rate which, in turn, is associated with decreased cardiac vagal tone, increased sympathetic catecholamine secretion, and greater cardiac beta-receptor sensitivity. Despite the elevation in heart rate, VO2max is reduced primarily from decreased maximal stroke volume and cardiac output. An elevated ejection fraction during exercise following bed rest suggests that the lower stroke volume is not caused by ventricular dysfunction but is primarily the result of decreased venous return associated with lower circulating blood volume, reduced central venous pressure, and higher venous compliance in the lower extremities. VO2max, stroke volume, and cardiac output are further compromised by exercise in the upright posture. The contribution of hypovolemia to reduced cardiac output during exercise following bed rest is supported by the close relationship between the relative magnitude (% delta) and time course of change in blood volume and VO2max during bed rest, and also by the fact that retention of plasma volume is associated with maintenance of VO2max after bed rest. Arteriovenous oxygen difference during maximal exercise is not altered by bed rest, suggesting that peripheral mechanisms may not contribute significantly to the decreased VO2max. However reduction in baseline and maximal muscle blood flow, red blood cell volume, and capillarization in working muscles represent peripheral mechanisms that may contribute to limited oxygen delivery and, subsequently, lowered VO2max. Thus, alterations in cardiac and vascular functions induced by prolonged confinement to bed rest contribute to diminution of maximal oxygen uptake and reserve capacity to perform physical work.

Non-NASA Center↗

Left ventricular outflow tract mean systolic acceleration as a surrogate for the slope of the left ventricular end-systolic pressure-volume relationship

OBJECTIVE: The goal of this study was to analyze left ventricular outflow tract systolic acceleration (LVOT(Acc)) during alterations in left ventricular (LV) contractility and LV filling. BACKGROUND: Most indexes described to quantify LV systolic function, such as LV ejection fraction and cardiac output, are dependent on loading conditions. METHODS: In 18 sheep (4 normal, 6 with aortic regurgitation, and 8 with old myocardial infarction), blood flow velocities through the LVOT were recorded using conventional pulsed Doppler. The LVOT(Acc) was calculated as the aortic peak velocity divided by the time to peak flow; LVOT(Acc) was compared with LV maximal elastance (E(m)) acquired by conductance catheter under different loading conditions, including volume and pressure overload during an acute coronary occlusion (n = 10). In addition, a clinically validated lumped-parameter numerical model of the cardiovascular system was used to support our findings. RESULTS: Left ventricular E(m) and LVOT(Acc) decreased during ischemia (1.67 +/- 0.67 mm Hg.ml(-1) before vs. 0.93 +/- 0.41 mm Hg.ml(-1) during acute coronary occlusion [p < 0.05] and 7.9 +/- 3.1 m.s(-2) before vs. 4.4 +/- 1.0 m.s(-2) during coronary occlusion [p < 0.05], respectively). Left ventricular outflow tract systolic acceleration showed a strong linear correlation with LV E(m) (y = 3.84x + 1.87, r = 0.85, p < 0.001). Similar findings were obtained with the numerical modeling, which demonstrated a strong correlation between predicted and actual LV E(m) (predicted = 0.98 [actual] -0.01, r = 0.86). By analysis of variance, there was no statistically significant difference in LVOT(Acc) under different loading conditions. CONCLUSIONS: For a variety of hemodynamic conditions, LVOT(Acc) was linearly related to the LV contractility index LV E(m) and was independent of loading conditions. These findings were consistent with numerical modeling. Thus, this Doppler index may serve as a good noninvasive index of LV contractility.

Non-NASA Center↗

Spatial distribution of pulmonary blood flow in dogs in increased force environments

Spatial distribution of pulmonary blood flow during 2- to 3-min exposures to 6-8 Gy acceleration was studied, using radioactive microspheres in dogs, and compared to previously reported 1 Gy control distributions. Isotope distributions were measured by scintiscanning individual 1-cm-thick cross sections of excised, fixed lungs. Results indicate: (1) the fraction of cardiac output traversing left and right lungs did not change systematically with the duration and magnitude of acceleration; but (2) the fraction is strongly affected by the occurrence or absence of fast deep breaths, which cause an increase or decrease, respectively, in blood flow through the dependent lung; and (3) Gy acceleration caused a significant increase in relative pulmonary vascular resistance (PVR) in nondependent and dependent regions of the lung concurrent with a decrease in PVR in the midsagittal region of the thorax.

Greenleaf, J. F.↗

Effects of acute hypoxia on cardiopulmonary responses to head-down tilt

Six male subjects were exposed on two separate occasions to simulated microgravity with 28 deg head-down tilt (HD) for 1 h with baseline followed by recovery at + 17 deg head-up. Pulmonary ventilation, gas exchange, spirometry, and central and cerebral blood flow characteristics were compared while breathing ambient air and reduced F(I)O2 equivalent to 14,828 ft. With hypoxia (HY), the increased tidal volume served to attenuate the drop in arterial saturation by reducing deadspace ventilation. Arterial and mixed venous PO2, values, estimated from peripheral venous samples and cardiac output (CO), were both maintained during HD in HY. Mixed venous PO2 was elevated by an increase in CO associated with a reduction in systemic resistance. Changes in spirometric indices during HD were not accentuated by HY, making the presence of interstitial edema unlikely. Cerebral flow and resistance showed minor reductions with HD. Tissue oxygenation and cardiopulmonary function were not notably effected by HD during HY, but a combination of these two stressors may predispose subjects to subsequent orthostatic intolerance during initial recovery.

Loeppky, J. A.↗

Ultraminiature manometer-tipped cardiac catheter

Miniature diaphragm-type capacitance transducer capable of being mounted on the end of a cardiac catheter has been developed for measurement of intravascular pressures. The transducer can be inserted in small ducts /arteries and veins/ without disturbing the flow characteristics. It is very useful for making measurements in babies.

Coon, G. W.↗

Effects of 12 days exposure to simulated microgravity on central circulatory hemodynamics in the rhesus monkey

Central circulatory hemodynamic responses were measured before and during the initial 9 days of a 12-day 10 degrees head-down tilt (HDT) in 4 flight-sized juvenile rhesus monkeys who were surgically instrumented with a variety of intrathoracic catheters and blood flow sensors to assess the effects of simulated microgravity on central circulatory hemodynamics. Each subject underwent measurements of aortic and left ventricular pressures, and aortic flow before and during HDT as well as during a passive head-up postural test before and after HDT. Heart rate, stroke volume, cardiac output, and left ventricular end-diastolic pressure were measured, and dP/dt and left ventricular elastance was calculated from hemodynamic measurements. The postural test consisted of 5 min of supine baseline control followed by 5 minutes of 90 degrees upright tilt (HUT). Heart rate, stroke volume, cardiac output, and left ventricular end-diastolic pressure showed no consistent alterations during HDT. Left ventricular elastance was reduced in all animals throughout HDT, indicating that cardiac compliance was increased. HDT did not consistently alter left ventricular +dP/dt, indicating no change in cardiac contractility. Heart rate during the post-HDT HUT postural test was elevated compared to pre-HDT while post-HDT cardiac output was decreased by 52% as a result of a 54% reduction in stroke volume throughout HUT. Results from this study using an instrumented rhesus monkey suggest that exposure to microgravity may increase ventricular compliance without alternating cardiac contractility. Our project supported the notion that an invasively-instrumented animal model should be viable for use in spaceflight cardiovascular experiments to assess potential changes in myocardial function and cardiac compliance.

NASA Discipline Cardiopulmonary↗

Defining the Relationship between Biomarkers of Oxidative and Inflammatory Stress and the Risk for Atherosclerosis in Astronauts during and after Long-duration Spaceflight

Future human space travel will consist primarily of long-duration missions onboard the International Space Station (ISS) or exploration-class missions to Mars, its moons, or nearby asteroids. These missions will expose astronauts to increased risk of oxidative and inflammatory damage from a variety of sources, including radiation, psychological stress, reduced physical activity, diminished nutritional status, and hyperoxic exposure during extravehicular activity. Evidence exists that increased oxidative damage and inflammation can accelerate the development of atherosclerosis. PURPOSE The purpose of this investigation is to determine whether biomarkers of oxidative and inflammatory stress are elevated during and after long-duration spaceflight and investigate if a relation exists between levels of these biomarkers and structural and functional indices of atherosclerotic risk measured in the carotid and brachial arteries. This is the first study to propose assessing atherosclerotic risk using biochemical, structural, and functional measures before, during, and immediately after spaceflight, and structural and functional measures for up to 5 years after landing. METHODS We will study 12 astronauts before, during, and up to 5 years after long-duration ISS missions. A panel of biomarkers of oxidative and inflammatory stress will be measured twice before flight, early (flight days 15 and 60) and late (2 weeks before landing) during the mission, and early in the postflight recovery phase (approx 3 days after landing). Arterial structure and vascular compliance will be measured at the same times and also at 1, 3, and 5 years after landing (surveillance). Arterial function will be measured using the same preflight, postflight, and surveillance schedule as arterial structure and vascular compliance measures, but will not be measured inflight. Biomarkers, some of which we have previously shown to be elevated with spaceflight, will be measured in venous blood samples and 24-h (in-flight) and 48-h (pre- and post-flight) urine pools. Arterial structure will be assessed from measures of carotid intima-media thickness, which have been shown to be better indicators of atherosclerotic than the Framingham Risk Score. Arterial function will be assessed using brachial flow-mediated dilation, a well-validated measure used to assess endothelium-dependent vasodilation and is a sensitive predictor of atherosclerotic risk. Arterial pulse pressure measured in the brachial artery and stroke volume measured from cardiac ultrasound will be used to assess hemodynamic status, cardiac function, and systemic vascular compliance. Three astronauts are actively participating in the preflight data collection and training activities. One astronaut has completed all preflight activities and will participate in the first in-flight data collection sessions by the end of 2013. The first post-flight data collection sessions will occur in the spring of 2014. EXPECTED RESULTS We hypothesize that biomarkers of oxidative and inflammatory stress will increased with spaceflight and will correlate with increased carotid intima-media thickness during and after flight and with decreased flow-mediated dilation after the mission. Furthermore, we hypothesize that measures of oxidative stress will return to baseline after flight, but biomarkers of inflammatory stress and vascular indices of atherosclerotic risk will remain elevated.

Lee, Stuart M. C.↗

Implantable telemetry for small animals

A series of totally implantable telemetry devices for use in measuring deep body parameters in small animals were developed. Under a collaborative agreement with NASA, several of these systems; the continuous wave Doppler ultrasonic flowmeter, the multichannel telemetry system, and the inductively-powered dual channel cardiac pacer were evaluated in a series of ten mongrel dogs (15 to 20 kg.). These systems were used to measure ascending aortic and coronary blood flow, aortic pressure, and subcutaneous EKG.

Source record↗

Noninvasive assessment of mitral inertness: clinical results with numerical model validation

Inertial forces (Mdv/dt) are a significant component of transmitral flow, but cannot be measured with Doppler echo. We validated a method of estimating Mdv/dt. Ten patients had a dual sensor transmitral (TM) catheter placed during cardiac surgery. Doppler and 2D echo was performed while acquiring LA and LV pressures. Mdv/dt was determined from the Bernoulli equation using Doppler velocities and TM gradients. Results were compared with numerical modeling. TM gradients (range: 1.04-14.24 mmHg) consisted of 74.0 +/- 11.0% inertial forcers (range: 0.6-12.9 mmHg). Multivariate analysis predicted Mdv/dt = -4.171(S/D (RATIO)) + 0.063(LAvolume-max) + 5. Using this equation, a strong relationship was obtained for the clinical dataset (y=0.98x - 0.045, r=0.90) and the results of numerical modeling (y=0.96x - 0.16, r=0.84). TM gradients are mainly inertial and, as validated by modeling, can be estimated with echocardiography.

NASA Discipline Cardiopulmonary↗

Hypergravity Alters the Susceptibility of Cells to Anoxia-Reoxygenation Injury

Gravity is a physical force, much like shear stress or mechanical stretch, and should affect organ and cellular function. Researchers have shown that gravity plays a role in ventilation and blood flow distribution, gas exchange, alveolar size and mechanical stresses within the lung. Short exposure to microgravity produced marked alterations in lung blood flow and ventilation distribution while hypergravity exaggerated the regional differences in lung structure and function resulting in reduced ventilation at the base and no ventilation of the upper half of the lung. Microgravity also decreased metabolic activity in cardiac cells, WI-38 embryonic lung cells, and human lymphocytes. Rats, in the tail-suspended head-down tilt model, experienced transient loss of lung water, contrary to an expected increase due to pooling of blood in the pulmonary vasculature. Hypergravity has also been found to increase the proliferation of several different cell lines (e.g., chick embryo fibroblasts) while decreasing cell motility and slowing liver regeneration following partial hepatectomy. These studies show that changes in the gravity environment will affect several aspects of organ and cellular function and produce major change in blood flow and tissue/organ perfusion. However, these past studies have not addressed whether ischemia-reperfusion injury will be exacerbated or ameliorated by changes in the gravity environment, e.g., space flight. Currently, nothing is known about how gravity will affect the susceptibility of different lung and vascular cells to this type of injury. We conducted studies that addressed the following question: Does the susceptibility of lung fibroblasts, vascular smooth muscle, and endothelial cells to anoxia/reoxygenation injury change following exposure to hypergravity conditions?

McCloud, Henry↗

Hindlimb unweighting affects rat vascular capacitance function

Microgravity is associated with an impaired stroke volume and, therefore, cardiac output response to orthostatic stress. We hypothesized that a decreased venous filling pressure due to increased venous compliance may be an important contributing factor in this response. We used a constant flow, constant right atrial pressure cardiopulmonary bypass procedure to measure total systemic vascular compliance (C(T)), arterial compliance (C(A)), and venous compliance (C(V)) in seven control and seven 21-day hindlimb unweighted (HLU) rats. These compliance values were calculated under baseline conditions and during an infusion of 0.2 microg*kg(-1)*min(-1) norepinephrine (NE). The change in reservoir volume, which reflects changes in unstressed vascular volume (DeltaV(0)) that occurred upon infusion of NE, was also measured. C(T) and C(V) were larger in HLU rats both at baseline and during the NE infusion (P < 0.05). Infusion of NE decreased C(T) and C(V) by ~20% in both HLU and control rats (P < 0.01). C(A) was also significantly decreased in both groups of rats by NE (P < 0.01), but values of C(A) were similar between HLU and control rats both at baseline and during the NE infusion. Additionally, the NE-induced DeltaV(0) was attenuated by 53% in HLU rats compared with control rats (P < 0.05). The larger C(V) and attenuated DeltaV(0) in HLU rats could contribute to a decreased filling pressure during orthostasis and thus may partially underlie the mechanism leading to the exaggerated fall in stroke volume and cardiac output seen in astronauts during an orthostatic stress after exposure to microgravity.

NASA Discipline Cardiopulmonary↗

Effect of head-down-tilt bed rest and hypovolemia on dynamic regulation of heart rate and blood pressure

Adaptation to head-down-tilt bed rest leads to an apparent abnormality of baroreflex regulation of cardiac period. We hypothesized that this "deconditioning response" could primarily be a result of hypovolemia, rather than a unique adaptation of the autonomic nervous system to bed rest. To test this hypothesis, nine healthy subjects underwent 2 wk of -6 degrees head-down bed rest. One year later, five of these same subjects underwent acute hypovolemia with furosemide to produce the same reductions in plasma volume observed after bed rest. We took advantage of power spectral and transfer function analysis to examine the dynamic relationship between blood pressure (BP) and R-R interval. We found that 1) there were no significant differences between these two interventions with respect to changes in numerous cardiovascular indices, including cardiac filling pressures, arterial pressure, cardiac output, or stroke volume; 2) normalized high-frequency (0.15-0.25 Hz) power of R-R interval variability decreased significantly after both conditions, consistent with similar degrees of vagal withdrawal; 3) transfer function gain (BP to R-R interval), used as an index of arterial-cardiac baroreflex sensitivity, decreased significantly to a similar extent after both conditions in the high-frequency range; the gain also decreased similarly when expressed as BP to heart rate x stroke volume, which provides an index of the ability of the baroreflex to alter BP by modifying systemic flow; and 4) however, the low-frequency (0.05-0.15 Hz) power of systolic BP variability decreased after bed rest (-22%) compared with an increase (+155%) after acute hypovolemia, suggesting a differential response for the regulation of vascular resistance (interaction, P < 0.05). The similarity of changes in the reflex control of the circulation under both conditions is consistent with the hypothesis that reductions in plasma volume may be largely responsible for the observed changes in cardiac baroreflex control after bed rest. However, changes in vasomotor function associated with these two conditions may be different and may suggest a cardiovascular remodeling after bed rest.

Non-NASA Center↗

Nuclear cardiograph and scintigraphy

Extensive advances in the technology of detectors, data analysis systems, and tracers used have resulted in greatly expanded applications of radioisotopes to the assessment of cardiac function and disease. The development of nuclear cardiology has proceeded along four lines: (1) radionuclide angiography, (2) myocardial perfusion imaging, (3) intracoronary microsphere imaging, and (4) regional myocardial blood flow determination using inert gases.

Mclaughlin, P.↗

Cardiopulmonary adaptation to weightlessness

The lung is profoundly affected by gravity. The absence of gravity (microgravity) removes the mechanical stresses acting on the lung paranchyma itself, resulting in a reduction in the deformation of the lung due to its own weight, and consequently altering the distribution of fresh gas ventilation within the lung. There are also changes in the mechanical forces acting on the rib cage and abdomen, which alters the manner in which the lung expands. The other way in which microgravity affects the lung is through the removal of the gravitationally induced hydrostatic gradients in vascular pressures, both within the lung itself, and within the entire body. The abolition of a pressure gradient within the pulmonary circulation would be expected to result in a greater degree of uniformity of blood flow within the lung, while the removal of the hydrostatic gradient within the body should result in an increase in venous return and intra-thoracic blood volume, with attendant changes in cardiac output, stroke volume, and pulmonary diffusing capacity. During the 9 day flight of Spacelab Life Sciences-1 (SLS-1) we collected pulmonary function test data on the crew of the mission. We compared the results obtained in microgravity with those obtained on the ground in both the standing and supine positions, preflight and in the week immediately following the mission. A number of the tests in the package were aimed at studying the anticipated changes in cardiopulmonary function, and we report those in this communication.

short duration↗

Three-dimensional echocardiographic planimetry of maximal regurgitant orifice area in myxomatous mitral regurgitation: intraoperative comparison with proximal flow convergence

OBJECTIVES: We sought to validate direct planimetry of mitral regurgitant orifice area from three-dimensional echocardiographic reconstructions. BACKGROUND: Regurgitant orifice area (ROA) is an important measure of the severity of mitral regurgitation (MR) that up to now has been calculated from hemodynamic data rather than measured directly. We hypothesized that improved spatial resolution of the mitral valve (MV) with three-dimensional (3D) echo might allow accurate planimetry of ROA. METHODS: We reconstructed the MV using 3D echo with 3 degrees rotational acquisitions (TomTec) using a transesophageal (TEE) multiplane probe in 15 patients undergoing MV repair (age 59 +/- 11 years). One observer reconstructed the prolapsing mitral leaflet in a left atrial plane parallel to the ROA and planimetered the two-dimensional (2D) projection of the maximal ROA. A second observer, blinded to the results of the first, calculated maximal ROA using the proximal convergence method defined as maximal flow rate (2pi(r2)va, where r is the radius of a color alias contour with velocity va) divided by regurgitant peak velocity (obtained by continuous wave [CW] Doppler) and corrected as necessary for proximal flow constraint. RESULTS: Maximal ROA was 0.79 +/- 0.39 (mean +/- SD) cm2 by 3D and 0.86 +/- 0.42 cm2 by proximal convergence (p = NS). Maximal ROA by 3D echo (y) was highly correlated with the corresponding flow measurement (x) (y = 0.87x + 0.03, r = 0.95, p < 0.001) with close agreement seen (AROA (y - x) = 0.07 +/- 0.12 cm2). CONCLUSIONS: 3D echo imaging of the MV allows direct visualization and planimetry of the ROA in patients with severe MR with good agreement to flow-based proximal convergence measurements.

NASA Discipline Cardiopulmonary↗

Estimation of left ventricular operating stiffness from Doppler early filling deceleration time in humans

Shortened early transmitral deceleration times (E(DT)) have been qualitatively associated with increased filling pressure and reduced survival in patients with cardiac disease and increased left ventricular operating stiffness (K(LV)). An equation relating K(LV) quantitatively to E(DT) has previously been described in a canine model but not in humans. During several varying hemodynamic conditions, we studied 18 patients undergoing open-heart surgery. Transesophageal echocardiographic two-dimensional volumes and Doppler flows were combined with high-fidelity left atrial (LA) and left ventricular (LV) pressures to determine K(LV). From digitized Doppler recordings, E(DT) was measured and compared against changes in LV and LA diastolic volumes and pressures. E(DT) (180 +/- 39 ms) was inversely associated with LV end-diastolic pressures (r = -0.56, P = 0.004) and net atrioventricular stiffness (r = -0.55, P = 0.006) but had its strongest association with K(LV) (r = -0.81, P < 0.001). K(LV) was predicted assuming a nonrestrictive orifice (K(nonrest)) from E(DT) as K(nonrest) = (0.07/E(DT))(2) with K(LV) = 1.01 K(nonrest) - 0.02; r = 0.86, P < 0.001, DeltaK (K(nonrest) - K(LV)) = 0.02 +/- 0.06 mm Hg/ml. In adults with cardiac disease, E(DT) provides an accurate estimate of LV operating stiffness and supports its application as a practical noninvasive index in the evaluation of diastolic function.

Non-NASA Center↗