The influence of electrode crack dimensions on the durability of polymer electrolyte membrane fuel cells

Electrode cracks in polymer electrolyte membrane fuel cells (PEMFCs) are correlated with early onset failures. Here, in this work we investigate the influence of cracked gas diffusion electrodes (GDEs) on the durability of the membrane electrode assembly (MEA) using a combined chemical-mechanical accelerated stress test (AST). Electrode crack dimensions were systematically tuned using ink formulations and material selection strategies. A parameter to describe the crack width areal density (Φ CW ) was used to quantify the degree of discontinuity in the electrode surfaces. Open circuit voltage (OCV) transient analyses were used to benchmark and characterize the failure mechanisms in the MEAs as a function of the Φ CW . While smaller electrode-level cracks, on the order of microns, yielded a 28 % decrease in operating lifetime, larger cracks that propagated from a discontinuous, microporous layer (MPL) coating, decreased the operating lifetime by 56 %. This work emphasizes the need for material processing strategies that consider defect tolerances to limit membrane failures in PEMFCs.

08 HYDROGEN↗

Novel Afferent Terminal Structure in the Crista Ampullaris of the Goldfish, Carassius auratus

Using transmission electron microscopy, we have identified a new type of afferent terminal structure in the crista ampullaris of the goldfish Carassius auratus. In addition to the bouton-type afferent terminals previously described in the ear of this species, the crista also contained enlarged afferent terminals that enveloped a portion of the basolateral hair cell membrane. The hair cell membrane was evaginated and protruded into the afferent terminal in a glove-and-finger configuration. The membranes of the two cells were regularly aligned in the protruded region of the contact and had a distinct symmetrical electron density. The electron-dense profiles of these contacts were easily identified and were present in every crista sampled. In some cases, efferent terminals synapsed onto the afferents at a point where the hair cell protruded into the terminal. The ultrastructural similarities of the goldfish crista afferents to calyx afferents found in amniotes (birds, reptiles, and mammals) are discussed. The results of the study support the hypothesis that structural variation in the vertebrate inner ear may have evolved much earlier in evolution than previously supposed.

Lanford, Pamela J.↗

Improved chemical and isotopic labeling of biomembranes in Bacillus subtilis by leveraging CRISPRi inhibition of beta-ketoacyl-ACP synthase (fabF)

Assessing the structure of living microbial cell membranes is a challenging analytical goal. The cell membrane is defined by its transverse structure, an approximately 5 nm-thick selectively permeable bilayer that serves many important cellular functions. Compositionally complex, dynamic, and organized in both the transverse and lateral dimensions, understanding the cell membrane structure—and the role that structure plays in cellular function, communication, and environmental sensing is an active scientific effort. Previously, we have devised a novel isotopic labeling approach for membrane lipids to enable direct in vivo structural studies of the cell membrane in the Gram-positive bacterium, Bacillus subtilis , using small-angle neutron scattering. This was accomplished through a genetic inhibition of fatty acid (FA) degradation (Δ fadN ) and a chemical inhibition of FA biosynthesis using cerulenin, an irreversible inhibitor of type II fatty acid synthases. Here, we improve upon the previous system by introducing a dCas9/sgRNA- fabF complex that blocks transcription of the essential fabF gene when under xylose induction. This leads to greater sensitivity to cerulenin in the mutant strain (JEBS102) and more robust cell growth when supplementary FAs are introduced to the culture medium. A subtle change in FA uptake is noted when compared to the prior labeling strategy. This is seen in the gas chromatography/mass spectrometry (GC/MS) data as a higher ratio of n 16:0 to a 15:0, and manifests in an apparent increase in the membrane thickness determined via neutron scattering. This represents an improved method of isotopic labeling for the cell membrane of Bacillus subtilis; enabling improved investigations of cellular uptake and utilization of FAs, cell membrane structure and organization as a phenotypic response to metabolic and environmental changes.

59 BASIC BIOLOGICAL SCIENCES↗

Understanding the E balance for water management in hydroxide exchange membrane fuel cells

As a key challenge for hydroxide exchange membrane fuel cells (HEMFCs), understanding water management deeply is critical for performance and durability improvement. Here, in this work, we show that the balance between water generation and phase-change-induced (PCI) flow is the main factor controlling cell voltage over a wide range of conditions where the cells are vulnerable to severe flooding. The regulation of flooding by heat generation can be reflected by a stable voltage with increase of current density in the polarization curve. This PCI balance voltage (E balance ), which determines the shape of polarization curve, is modeled as a function of cell operating conditions and gas diffusion layer (GDL) properties. Temperature, pressure, and thermal conductivity of GDL were found important for tuning the level of E balance , both in HEMFCs and proton exchange membrane fuel cells. The understanding of E balance will help to generate strategies for resolving flooding in HEMFCs, and it offers a new perspective for polarization curve interpretation.

25 ENERGY STORAGE↗

Study of Cathode Gas Diffusion Architecture for Improved Oxygen Transport in Hydroxide Exchange Membrane Fuel Cells

The high pH environment in hydroxide exchange membrane fuel cells (HEMFCs) has the potential to reach lower costs than the current proton exchange membrane fuel cells (PEMFCs), the incumbent technology. A significant difference between HEMFCs and PEMFCs is the location of water production within the cell. In PEMFCs, the water is produced on the cathode, limiting oxygen transport. In HEMFCs, the water is produced on the anode where the fuel is pure hydrogen. This allows the cathode to be optimized for oxygen transport without the presence of excess liquid water. Limiting current analysis, a technique previously used in PEMFCs, is adopted in HEMFCs to evaluate the oxygen mass transport resistances for different sections of the cathode. Through elimination of the microporous layer (MPL), gas diffusion layer (GDL), and traditional flow field and using porous nickel foam for gas distribution, the transport resistance at an operating condition of 150 kPa(g) and with the cell temperature at 80 °C was decreased from 112 s m −1 to 48 s m −1 , effectively halved. The optimal configuration for performance was found with Ni foam and a GDL, eliminating the MPL and traditional flow field, which vastly improved oxygen transport while maintaining adequate electrical contact with the cathode catalyst layer.

25 ENERGY STORAGE↗

Comparison of Planar and Tubular Flow Field Plates for Proton Exchange Membrane Fuel Cells (PEMFCs) through Simulation

Proton exchange membrane fuel cells are excellent clean energy alternatives to current non-renewable energy sources. Bipolar plates are a key component of these fuel cells and directly responsible for their performance. Traditional bipolar plates are created in a planar form, but recent research has revealed a novel tubular design that performs similarly to conventional plates. Here, this study compares traditional planar designs with tubular ones. The finite element ANSYS software was used to determine and visualize velocity and pressure distributions of fluid flow through the bipolar plate channels.

25 ENERGY STORAGE↗

Effect of reacting gas flowrates and hydration on the carbonation of anion exchange membrane fuel cells in the presence of CO 2

Anion exchange membrane fuel cells (AEMFCs) have been widely touted as a low-cost alternative to existing proton exchange membrane fuel cells. However, one of the limitations of this technology has been the severe performance penalty related to the introduction of CO 2 to the cell – typically in the air cathode feed. Introduction of CO 2 into AEMFCs results in cell carbonation, which imparts thermodynamic, kinetic and Ohmic overpotentials that can add up to hundreds of millivolts. Therefore, it is important to find strategies and operational protocols for AEMFCs that minimize these overpotentials. In this paper, we reserach the impacts of the anode and cathode flowrate, as well as the cell hydration level, on the extent of cell carbonation and cell polarization. Key findings include: (1) decreasing the cathode flowrate generally decreases the total CO 2 -related voltage loss while changing the anode flowrate has a minimal effect; (2) increasing cell hydration helps to mitigate the performance loss in the presence of CO 2 ; and (3) operational combinations are found that significantly reduce the CO 2 penalty compared to the present literature.

25 ENERGY STORAGE↗

Engineered Thin Diffusion Layers for Anion-Exchange Membrane Electrolyzer Cells with Outstanding Performance

Anion-exchange membrane electrolyzer cells (AEMECs) are one of the most promising technologies for carbon-neutral hydrogen production. Over the past few years, the performance and durability of AEMECs have substantially improved. Herein, we report an engineered liquid/gas diffusion layer (LGDL) with tunable pore morphologies that enables the high performance of AEMECs. The comparison with a commercial titanium foam in the electrolyzer indicated that the engineered LGDL with thin-flat and straight-pore structures significantly improved the interfacial contacts, mass transport, and activation of more reaction sites, leading to outstanding performance. We obtained a current density of 2.0 A/cm 2 at 1.80 V with an efficiency of up to 81.9% at 60 °C under 0.1 M NaOH-fed conditions. The as-achieved high performance in this study provides insight to design advanced LGDLs for the production of low-cost and high-efficiency AEMECs.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Nonhumidified High-Temperature Membranes Developed for Proton Exchange Membrane Fuel Cells

Fuel cells are being considered for a wide variety of aerospace applications. One of the most versatile types of fuel cells is the proton-exchange-membrane (PEM) fuel cell. PEM fuel cells can be easily scaled to meet the power and space requirements of a specific application. For example, small 100-W PEM fuel cells are being considered for personal power for extravehicular activity suit applications, whereas larger PEM fuel cells are being designed for primary power in airplanes and in uninhabited air vehicles. Typically, PEM fuel cells operate at temperatures up to 80 C. To increase the efficiency and power density of the fuel cell system, researchers are pursuing methods to extend the operating temperature of the PEM fuel cell to 180 C. The most widely used membranes in PEM fuel cells are Nafion 112 and Nafion 117--sulfonated perfluorinated polyethers that were developed by DuPont. In addition to their relatively high cost, the properties of these membranes limit their use in a PEM fuel cell to around 80 C. The proton conductivity of Nafion membranes significantly decreases above 80 C because the membrane dehydrates. The useful operating range of Nafion-based PEM fuel cells can be extended to over 100 C if ancillary equipment, such as compressors and humidifiers, is added to maintain moisture levels within the membrane. However, the addition of these components reduces the power density and increases the complexity of the fuel cell system.

Kinder, James D.↗

Effects of Ink Formulation on Construction of Catalyst Layers for High-Performance Polymer Electrolyte Membrane Fuel Cells

Rational design of catalyst layers in a membrane electrode assembly (MEA) is crucial for achieving high-performance polymer electrolyte membrane fuel cells. Establishing a clear understanding of the property (catalyst ink)–structure (catalyst layer)–performance (MEA) relationship lays the foundation for this rational design. Here, a synergistic approach was taken to correlate the ink formulation, the microstructure of catalyst layers, and the resulting MEA performance to establish such a property–structure–performance relationship. The solvent composition (n-PA/H 2 O mixtures) demonstrated a strong influence on the performance of the MEA fabricated with an 830-EW (Aquivion) ionomer, especially polarization losses of cell activation and mass transport. The performance differences were studied in terms of how the solvent composition affects the catalyst/ionomer interface, ionomer network, and pore structure of the resulting catalyst layers. The ionomer aggregates mainly covered the surface of catalyst aggregates acting as oxygen reduction reaction active sites, and the aggregate sizes of the ionomer and catalyst (revealed by ultrasmall angle X-ray scattering and cryo-transmission electron microscopy) were dictated by tuning the solvent composition, which in turn determined the catalyst/ionomer interface (available active sites). In n-PA/H 2 O mixtures with 50~90 wt % H 2 O, the catalyst agglomerates could be effectively broken up into small aggregates, leading to enhanced kinetic activities. The boiling point of the mixed solvents determined the pore structure of ultimate catalyst layers, as evidenced by mercury porosimetry and scanning electron microscopy. For mixed solvents with a higher boiling point, the catalyst–ionomer aggregates in the ink tend to agglomerate during the solvent evaporation process and finally form larger catalyst–ionomer aggregates in the ultimate catalyst layer, resulting in more secondary pores and thus lower mass transport resistance. Both the enlarged catalyst/ionomer interface and appropriate pore structure were achieved with the catalyst layer fabricated from an n-PA/H 2 O mixture with 90 wt % H 2 O, leading to the best MEA performance.

25 ENERGY STORAGE↗

Anhydrous Proton-Conducting Membranes for Fuel Cells

Polymeric electrolyte membranes that do not depend on water for conduction of protons are undergoing development for use in fuel cells. Prior polymeric electrolyte fuel-cell membranes (e.g., those that contain perfluorosulfonic acid) depend on water and must be limited to operation below a temperature of 125 C because they retain water poorly at higher temperatures. In contrast, the present developmental anhydrous membranes are expected to function well at temperatures up to 200 C. The developmental membranes exploit a hopping-and-reorganization proton- conduction process that can occur in the solid state in organic amine salts and is similar to a proton-conduction process in a liquid. This process was studied during the 1970s, but until now, there has been no report of exploiting organic amine salts for proton conduction in fuel cells.

Narayanan, Sekharipuram↗

Elucidating the degradation mechanisms of Pt-free anode anion-exchange membrane fuel cells after durability testing

The development of anion-exchange membrane fuel cells (AEMFCs) has recently accelerated due to synergistic improvements yielding highly conductive membranes, stable ionomers, and enhanced alkaline electrocatalysts. However, cell durability, especially under realistic conditions, still poses a major challenge. Herein, we employ low-loadings of Pt-free Pd-based catalysts in the anode of AEMFCs and elucidate potential degradation mechanisms impacting long-term performance under conditions analogous to the real-world (high current density, H 2 –air (albeit CO 2 -free), and intermittent operation). Our high-performing AEMFCs achieve impressive performance with power densities approaching 1 W cm —2 and current densities up to 3.5 A cm —2 . Over a 200 h period of continuous operation in H 2 –air at a current density of 600 mA cm —2 , our model Pd/C–CeO 2 anode cell exhibits record stability (~30 μV h —1 degradation) compared to the literature and up to 6× better stability than our Pd/C and commercial Pt/C anode cells. Following an 8 h shutdown, the Pd/C–CeO 2 anode cell was restarted and continued for an additional 300 h with a higher degradation rate of ~600 μV h —1 . Thorough in situ evaluations and post-stability analyses provide insights into potential degradation mechanisms to be expected during extended operation under more realistic conditions and provide mitigation strategies to enable the widespread development of highly durable AEMFCs.

08 HYDROGEN↗

Optimization of catalyst-coated membranes for enhancing performance in proton exchange membrane electrolyzer cells

To achieve large-scale application of proton exchange membrane electrolyzer cells (PEMECs) for hydrogen production, it is highly desirable to reduce the manufacturing cost while enhancing cell performance. In the PEMPECs, a catalyst-coated membrane (CCM) is the vital component where electrochemical reactions and mass transport mainly occur. The fabrication methods and catalyst layer (CL) structure can significantly affect the cell performance. Herein, for the first time, a comparative study of CCM fabrications with decal transfer and direct spray deposition methods have been conducted by both ex-situ materials characterization and in-situ performance testing in PEMECs. It is found CCMs that are fabricated with a direct spray deposition method display enhanced cell performance compared to CCMs fabricated with a decal transfer method, mainly due to the largely reduced ohmic resistance and improved mass transport. More importantly, cell performance can be greatly enhanced by simply regulating the Nafion ionomer content at the anode CL. The optimal Nafion ionomer content of 10 wt% gives the best cell performance at 80 °C with a low cell voltage of 1.887 V at 2 A cm -2 , outperforming the commercial CCM and most other previous publications. Our study provides a valuable guidance for fabrication and optimization of CCMs with significantly enhanced performance and reduced cost for practical application of the PEMECs.

08 HYDROGEN↗

An overview of bipolar plates in proton exchange membrane fuel cells

Bipolar plates are a crucial component of proton exchange membrane fuel cells. They are responsible for transporting reactant gases, carrying the current from the membrane electrode assembly to the end plates, providing heat and water management, and separating the individual cells. However, these plates also contribute to 80% of the fuel cell’s weight, 50% of its volume, and 40% of its cost, posing a barrier to the commercialization of fuel cells. This paper provides a comprehensive review of the materials and manufacturing processes used in the fabrication of bipolar plates as well as recent research conducted on the improvement of bipolar plate weight, volume, and cost through material selection and manufacturing methods. Additive manufacturing is highlighted in this work as an innovative manufacturing method to produce bipolar plates. Novel contributions in this paper include a detailed explanation of traditional manufacturing processes for metallic and graphitic-polymer bipolar plates as well as a cost comparison between additive and traditional manufacturing processes.

08 HYDROGEN↗

Durability of PGM catalyst MEAs of polymer electrolyte membrane fuel cells for heavy-duty vehicles

Polymer electrolyte membrane fuel cells (PEMFCs) are promising power sources for heavy-duty vehicles (HDVs) owing to cleanliness and efficiency. However, the degradation of membrane electrode assemblies (MEAs) under HDV conditions remains a huge challenge. Here, this work investigated MEA durability under HDV conditions using a US Department of Energy standard accelerated stress test for 180,000 cycles (equivalent to 1 million miles of HDV operation). Effects of catalyst Pt content on MEA durability were examined using homemade 30% Pt/C (H-Pt/C) and commercial 46% Pt/C (C-Pt/C) catalysts. Both MEAs experienced H 2 /air and H 2 /O 2 performance loss over cycles. Analysis with scanning transmission electron microscopy, X-ray diffraction, inductively coupled plasma mass spectrometry, and mercury intrusion porosimetry revealed severe degradation of Pt nanoparticles (NPs), support structures, and the catalyst layer. Two degradation stages for NPs were proposed: Ostwald ripening dominated the initial 60,000 cycles, followed by combined Ostwald ripening and particle migration. Measurements with ion chromatography, high-frequency resistance, and oxygen-diffusion resistance revealed degradation of membrane and ionomer, respectively.

25 ENERGY STORAGE↗

Advanced Electrode Structures for Proton Exchange Membrane Fuel Cells: Current Status and Path Forward

Abstract Proton exchange membrane fuel cells (PEMFCs) have demonstrated their viability as a promising candidate for clean energy applications. However, performance of conventional PEMFC electrodes, especially the cathode electrode, suffers from low catalyst utilization and sluggish mass transport due to the randomly distributed components and tortuous transport pathways. Development of alternative architectures in which the electrode structure is controlled across a range of length scales provides a promising path toward overcoming these limitations. Here, we provide a comprehensive review of recent research and development of advanced electrode structures, organized by decreasing length-scale from the millimeter-scale to the nanometer-scale. Specifically, advanced electrode structures are categorized into five unique architectures for specific functions: (1) macro-patterned electrodes for enhanced macro-scale mass transport, (2) micro-patterned electrodes for enhanced micro-scale mass transport, (3) electrospun electrodes with fiber-based morphology for enhanced in-plane proton transport and through-plane O 2 transport, (4) enhanced-porosity electrodes for improved oxygen transport through selective inclusion of void space, and (5) catalyst film electrodes for elimination of carbon corrosion and ionomer poisoning. The PEMFC performance results achieved from each alternative electrode structure are presented and tabulated for comparison with conventional electrode architectures. Moreover, analysis of mechanisms by which new electrode structures can improve performance is presented and discussed. Finally, an overview of current limitations and future research needs is presented to guide the development of electrode structures for next generation PEMFCs. Graphical Abstract Development of improved electrode architectures with the control of structure on length scales ranging from millimeters to nanometers could enable a new generation of fuel cells with increased performance and reduced cost. This paper presents an in-depth review and critical analysis of recent developments and future outlook on the design of advanced electrode structures.

25 ENERGY STORAGE↗

The application of Dow Chemical's perfluorinated membranes in proton-exchange membrane fuel cells

Dow Chemical's research activities in fuel cells revolve around the development of perfluorosulfonic acid membranes useful as the proton transport medium and separator. Some of the performance characteristics which are typical for such membranes are outlined. The results of tests utilizing a new experimental membrane useful in proton-exchange membrane fuel cells are presented. The high voltage at low current densities can lead to higher system efficiencies while, at the same time, not sacrificing other critical properties pertinent to membrane fuel cell operation. A series of tests to determine response times indicated that on-off cycles are on the order of 80 milliseconds to reach 90 percent of full power. The IR free voltage at 100 amps/sq ft was determined and the results indicating a membrane/electrode package resistance to be .15 ohm-sq cm at 100 amps/sq ft.

Eisman, G. A.↗