Search NASASearch

SEARCH · Search NASA

Results for “Chemical looping”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

147 records · Page 5

The Operational NASA Anomaly Gas Analyzer and Exploration Follow-Ons

The NASA Anomaly Gas Analyzer (AGA) is the culmination of nearly ten years of advancement of core technology originally developed by Vista Photonics through the Small Business Innovation Research (SBIR) program and expanded using NASA program funding. The AGA is a portable, battery operated, optical gas detection instrument for continuous monitoring of H 2 O, CO 2 , O 2 , CO, NH 3 , HCN, HF, HCl in the spacecraft environment. Real time, in-situ monitored, gas concentrations are communicated at 1 Hz through a built-in display on-orbit and additionally through a serial interface on the ground. The instruments function over the typical range of temperatures and pressures required for the spacecraft environment. A ten-year operational life is targeted. Seven AGA instruments are currently deployed on the International Space Station and two Orion-specific units are manifested for Artemis 2. A variation of the operational AGA is under development for lunar Human Landing Systems. A wider calibrated operating pressure envelope is required in this application. Otherwise, the instruments straightforwardly address lessons learned from the original AGA by improving aspects of thermal control, ruggedness, and ease-of-use. A subset of AGA-developed sensed gases (H 2 O, CO 2 , O 2 ) is the subject of the Primary Constituent Monitor (PCM) development for the Habitation and Logistics Outpost (HALO) destined for lunar orbit. Two PCMs will be installed in HALO as part of the environmental control loop where they will interface with vehicle power and communications. While the basic sensor techniques are unchanged from the AGA, these instruments have been radiation hardened to survive for many years in the harsh target environment. Current development status for these instruments will be presented along with recent developments of a naval submarine variant.

Air Monitoring

Designing a Propylene-Glycol Coolant Servicer System for Gateway’s Internal Active Thermal Control System

A human spacecraft ATCS—especially one using single-phase coolant loops exposed to cabin atmospheric conditions—requires periodic degassing and refilling to support long-duration missions of 15 to 30 years. During initial fill operations, system maintenance, gas permeation, and quick-disconnect mating or de-mating, small amounts of gas can gradually enter the coolant system over time. This can lead to degraded heat transfer performance, pump cavitation, and potentially pump vapor lock if a significant gas volume accumulates over time. Additionally, system leaks and routine fluid sampling can gradually reduce accumulator volumes to unacceptable levels, requiring periodic refills. In more severe cases, catastrophic changes in fluid composition may necessitate emergency draining, refilling, and degassing to ensure continued system functionality. These risks were identified and mitigated on the ISS ITCS through the development of a dual-membrane degasser ORU and a Fluid Servicer System ORU for coolant refilling. These systems were developed for the fully water-based ISS ITCS Coolant[1]. The Gateway space station, the first permanent human habitat in lunar orbit, uses a propylene-glycol/water coolant mixture, which has significantly different fluid properties compared to pure water. Because microgravity degassing technologies are sensitive to fluid surface tension and viscosity, existing ISS hardware is not suitable for servicing a propylene-glycol-based TCS. Unlike the ISS, the Gateway will operate in a higher-radiation environment and must meet stricter mass constraints due to its location outside of low earth orbit. This Government Furnished Equipment (GFE) flight hardware project aims to develop a lightweight, radiation-resistant Coolant Servicer System (CSS) capable of degassing and refilling Gateway’s propylene-glycol water-based IATCS.

Propylene Glycol Water

Lunar and Planetary Science XXXVI, Part II

Some topics covered: Implications of internal fragmentation on the structure of comets; Atmospheric excitation of mars polar motion; Dunite viscosity dependence on oxygen fugacity; Cross profile and volume analysis of bahram valles on mars; Calculations of the fluxes of 10-250 kV lunar leakage gamma rays; Alluvian fans on mars; Investigating the sources of the apollo 14 high-Al mare basalts; Relationship of coronae, regional plains and rift zones on venus; and Chemical differentiation and internal structure of europa and callisto.

Lunar and Planetary Science

Designing a Propylene-Glycol Coolant Servicer System for Gateway’s Internal Active Thermal Control System

A human spacecraft ATCS—especially one using single-phase coolant loops exposed to cabin atmospheric conditions—requires periodic degassing and refilling to support long-duration missions of 15 to 30 years. During initial fill operations, system maintenance, gas permeation, and quick-disconnect mating or de-mating, small amounts of gas can gradually enter the coolant system over time. This can lead to degraded heat transfer performance, pump cavitation, and potentially pump vapor lock if a significant gas volume accumulates over time. Additionally, system leaks and routine fluid sampling can gradually reduce accumulator volumes to unacceptable levels, requiring periodic refills. In more severe cases, catastrophic changes in fluid composition may necessitate emergency draining, refilling, and degassing to ensure continued system functionality. These risks were identified and mitigated on the ISS ITCS through the development of a dual-membrane degasser ORU and a Fluid Servicer System ORU for coolant refilling. These systems were developed for the fully water-based ISS ITCS Coolant[1]. The Gateway space station, the first permanent human habitat in lunar orbit, uses a propylene-glycol/water coolant mixture, which has significantly different fluid properties compared to pure water. Because microgravity degassing technologies are sensitive to fluid surface tension and viscosity, existing ISS hardware is not suitable for servicing a propylene-glycol-based TCS. Unlike the ISS, the Gateway will operate in a higher-radiation environment and must meet stricter mass constraints due to its location outside of low earth orbit. This Government Furnished Equipment (GFE) flight hardware project aims to develop a lightweight, radiation-resistant Coolant Servicer System (CSS) capable of degassing and refilling Gateway’s propylene-glycol water-based IATCS.

Propylene Glycol Water

Recirculating and Sub-Atmospheric Rapid Cycle Amine Swing Bed Testing at Various Metabolic Profiles, Temperatures, and Half-Cycle Times

Sixty years since the first spacewalk, NASA’s Extravehicular Mobility Unit (xEMU) exploration space suit has undergone numerous design improvements and iterations. As commercial manufacturers develop next-generation systems to support increasingly complex missions, including Moon-to-Mars architecture prototyping and the design of the Martian Portable Life Support System (PLSS), material selection and individual subunit testing under realistic metabolic and pressure conditions are paramount. To determine whether a reusable carbon dioxide (CO 2 ) scrubber design and adsorbent can be utilized in new suit configurations, an all-encompassing test rig is required to compare existing and newly developed technologies. The test rig must be capable of sub-atmospheric testing, calibrated humid CO 2 dosing, and facilitation of the evaluation of sorbents across a wide range of operational requirements. Recently, XploSafe has developed an Extravehicular Mobility Unit (xEMU) testing rig specifically designed to explore CO 2 and humidity control materials for spacesuits. This closed-loop recirculating swing bed (Rapid Cycle Amine Test Rig) was utilized to compare adsorbent utility across a wide range of xEMU operating conditions. Following successful testing with Xplo-SA9T over multiple simulated eight-hour Extravehicular Activity (EVA) tests, improvements to the test stand were considered. Regeneration vacuum supply within the test rig was updated to more closely resemble space vacuum, theoretically increasing half-cycle timing. An improved water vapor delivery system was incorporated to dose a wider calibrated range of humidity over both short and long-duration EVAs. A range of metabolic profiles between 800 and 3000 BTU/h were tested, and the corresponding average CO 2 steady-states were compared. The effect of dosing temperature at the adsorbent bed inlet between 10 and 40 ̊C and the corresponding CO 2 removal efficiency was also evaluated.

John R Tidwell

Battery Pack Shape Optimization using Transient Heat Conduction Coupled with Cell-Discharge Analysis

Battery electric systems exhibit significant time-dependence, especially when evaluated in the context of an aircraft mission profile with continually changing power demands. Additionally, when evaluating battery-powered aircraft concepts, it is important to accurately compute the temperature of the batteries and properly characterize the thermal response of the system. The temperature of the batteries has a significant impact on cell performance, in addition to safety considerations of maintaining battery temperatures below their operating limit. Because of these considerations, battery models for preliminary design and optimization of aircraft should include the capability to accurately compute the temperature distribution within the battery pack. Furthermore, battery pack designs should be as light-weight as possible to maximize the pack energy density, while also considering battery temperature limits. Here, we demonstrate a simultaneous trajectory and shape optimization of a battery pack concept, using a transient heat transfer finite element model coupled with a time-varying cell-discharge battery model to provide this capability. The transient finite-element analysis is done using TACS, and the cell-discharge battery model uses OpenMDAO and dymos. Including the transient finite element problem in the loop enables accurate temperatures that can be passed back to the cell discharge model, while the cell discharge model can supply the finite element model with time-varying heat boundary conditions, further benefiting the fidelity of the thermal response of the batteries. We first demonstrate the coupling capability between the battery cell-discharge model and the transient finite-element heat transfer through an optimization which computes the optimal current profile for the battery pack while ensuring the battery temperatures remain below their operational limit. We then build on this optimization by adding shape optimization to the problem, which allows us to consider a composite objective function which also minimizes the mass of the battery pack, while also producing an optimal current discharge profile.

Optimization

Microbiological Characterization and Concerns of the International Space Station Internal Active Thermal Control System

Since January 1999, the chemical the International Space Station Thermal Control System (IATCS) and microbial state of (ISS) Internal Active fluid has been monitored by analysis of samples returned to Earth. Key chemical parameters have changed over time, including a drop in pH from the specified 9.5 +/- 0.5 ta = 58.4, an increase in the level of total inorganic carbon (TIC), total organic carbon (TOC) and dissolved nickel (Ni) in the fluid, and a decrease in the phosphate (PO,) level. In addition, silver (AS) ion levels in the fluid decreased rapidly as Ag deposited on internal metallic surfaces of the system. The lack of available Ag ions coupled with changes in the fluid chemistry has resulted in a favorable environment for microbial growth. Counts of heterotrophic bacteria have increased from less than 10 colony-forming units (CFUs)/l00 mL to l0(exp 6) to l0(exp 7) CFUs/100 mL. The increase of the microbial population is of concern because uncontrolled microbiological growth in the IATCS can contribute to deterioration in the performance of critical components within the system and potentially impact human health if opportunistic pathogens become established and escape into the cabin atmosphere. Micro-organisms can potentially degrade the coolant chemistry; attach to surfaces and form biofilms; lead to biofouling of filters, tubing, and pumps; decrease flow rates; reduce heat transfer; initiate and accelerate corrosion; and enhance mineral scale formation. The micro- biological data from the ISS IATCS fluid, and approaches to addressing the concerns, are summarized in this paper.

Monsi C Roman

Dynamic Regulation of Sub-Atmospheric Pressure for Constant and Cyclic Gas Loads During Testing of Spacesuit Components

New iterations of the various subsystems within the spacesuit will benefit from a new sorbent technology. For example, sorbents used in the Trace Contaminant Control (TCC) and the Rapid Cycle Amine (RCA) systems within the Exploration Portable Life Support System (xPLSS), part of the Extra-Vehicular Mobility Unit (xEMU). For proper validation, the sub-atmospheric pressure needs to be maintained within a simulated 2 ft 3 spacesuit volume. The traditional approach, which involves placing the entire vent loop within a hypobaric chamber, is not practical for the widespread testing of components and prototypes, as these specialized chambers are costly and not widely available. A two-stage regulator based sub-atmospheric pressure system is presented in this work. The method regulates the pressure based on pressure differentials between the pressure regulation pump, the test system, and the ambient environment. The performance of this system is demonstrated using data collected during a 150+ hour non-regenerative TCC sorbent evaluation, several 24-hour regenerative TCC sorbent evaluations with different regeneration cycles, and an 8-hour RCA sorbent evaluation, all under xEMU operating conditions. For regulation, the inlet regulator was set to propagate a small leak to increase the stability of the system as the gas load from the testing system changes. It was also found that controlling the input flow rate that replaces the material lost during regeneration is critical for ensuring the stability of the system. This system provided excellent pressure regulation, without adjustments, for constant loads during shorter time evaluations (hours), while longer time evaluations (days) are easily obtainable with periodic regulator adjustments. A second method is under development to address longer-term stability and to automate pressure regulation. It will incorporate flow and pressure measurements to dynamically control a set of electronically controlled proportional valves for adjusting the pumping speed and air bleed supply.

Nicholas F Materer

Properties of a Ni19.5Pd30Ti50.5 High-Temperature Shape Memory Alloy in Tension and Compression

Potential applications involving high-temperature shape memory alloys have been growing in recent years. Even in those cases where promising new alloys have been identified, the knowledge base for such materials contains gaps crucial to their maturation and implementation in actuator and other applications. We begin to address this issue by characterizing the mechanical behavior of a Ni 19.5 Pd 30 Ti 50.5 high-temperature shape memory alloy in both uniaxial tension and compression at various temperatures. Differences in the isothermal uniaxial deformation behavior were most notable at test temperatures below the martensite finish temperature. The elastic modulus of the material was very dependent on strain level; therefore, dynamic Young’s Modulus was determined as a function of temperature by an impulse excitation technique. More importantly, the performance of a thermally activated actuator material is dependent on the work output of the alloy. Consequently, the strain-temperature response of the Ni 19.5 Pd 30 Ti 50.5 alloy under various loads was determined in both tension and compression and the specific work output calculated and compared in both loading conditions. It was found that the transformation strain and thus, the specific work output were similar regardless of the loading condition. Also, in both tension and compression, the strain-temperature loops determined under constant load conditions did not close due to the fact that the transformation strain during cooling was always larger than the transformation strain during heating. This was apparently the result of permanent plastic deformation of the martensite phase with each cycle. Consequently, before this alloy can be used under cyclic actuation conditions, modification of the microstructure or composition would be required to increase the resistance of the alloy to plastic deformation by slip.

High-Temperature Shape Memory Alloy

In-suit CO2 Washout Test System (ICWTS) for CO2 Washout Verification in Spacesuits

Since the time of Mercury, Gemini, and Apollo, NASA has been performing CO 2 washout verification of spacesuits with Human in the Loop (HITL) test methods. Classically, the only instrumentation both with the accuracy and response time necessary was that of external mass spectrometers or medical gas analyzers fed by a long capillary line from the oro-nasal region within the suit. The helmet CO 2 washout configuration including the challenges posed by variation of a suited human subject frequently created difficulty in capturing adequate breath by breath data. For example, a nasal cannula could be worn with reasonable comfort however it posed the following challenges: (1) impeded the test subject’s ability to do a proper Valsalva maneuver; (2) frequently provided a corrupted waveform with relative movement; (3) precluded the ability to evaluate the Flow Weighted Average (FWA) at subject interface. A mouthpiece could be used in lieu of a cannula but posed challenges as well: (1) created potential disturbances of the flow field; (2) precluded the test subject from speaking during usage; and (3) presented comfort issues limiting the duration of test points. These challenges made it impractical to use a mouthpiece for anything other than short lab ambient environment tests. Technology development and NASA investment have afforded new capabilities to address some of these measurements providing improved data collection and are implemented in the In-suit CO 2 Washout Test System (ICWTS) which provides suit inlet/outlet pressure, temperature, relative humidity, partial pressure of oxygen, partial pressure of CO 2 , and flow measurement coupled with the acquisition of the inspired PPCO 2 including the ability for FWA measurement. This test system, coupled with use of the In-suit Respiration Mannequin Assembly (IRMA) and Computational Fluid Dynamics (CFD) combine to provide a full picture of the in-suit oro-nasal flow field and effectiveness of CO 2 washout in a spacesuit design.

Colin Campbell

In-suit CO 2 Washout Test System (ICWTS) for CO 2 Washout Verification in Spacesuits

Since the time of Mercury, Gemini, and Apollo, NASA has been performing CO 2 washout verification of spacesuits with Human in the Loop (HITL) test methods. Classically, the only instrumentation both with the accuracy and response time necessary was that of external mass spectrometers or medical gas analyzers fed by a long capillary line from the oro-nasal region within the suit. The helmet CO 2 washout configuration including the challenges posed by variation of a suited human subject frequently created difficulty in capturing adequate breath by breath data. For example, a nasal cannula could be worn with reasonable comfort however it posed the following challenges: (1) impeded the test subject’s ability to do a proper Valsalva maneuver; (2) frequently provided a corrupted waveform with relative movement; (3) precluded the ability to evaluate the Flow Weighted Average (FWA) at subject interface. A mouthpiece could be used in lieu of a cannula but posed challenges as well: (1) created potential disturbances of the flow field; (2) precluded the test subject from speaking during usage; and (3) presented comfort issues limiting the duration of test points. These challenges made it impractical to use a mouthpiece for anything other than short lab ambient environment tests. Technology development and NASA investment have afforded new capabilities to address some of these measurements providing improved data collection and are implemented in the In-suit CO 2 Washout Test System (ICWTS) which provides suit inlet/outlet pressure, temperature, relative humidity, partial pressure of oxygen, partial pressure of CO 2 , and flow measurement coupled with the acquisition of the inspired PPCO 2 including the ability for FWA measurement. This test system, coupled with use of the In-suit Respiration Mannequin Assembly (IRMA) and Computational Fluid Dynamics (CFD) combine to provide a full picture of the in-suit oro-nasal flow field and effectiveness of CO 2 washout in a spacesuit design.

Colin Campbell

General Purpose Data-Driven Monitoring for Space Operations

As modern space propulsion and exploration systems improve in capability and efficiency, their designs are becoming increasingly sophisticated and complex. Determining the health state of these systems, using traditional parameter limit checking, model-based, or rule-based methods, is becoming more difficult as the number of sensors and component interactions grow. Data-driven monitoring techniques have been developed to address these issues by analyzing system operations data to automatically characterize normal system behavior. System health can be monitored by comparing real-time operating data with these nominal characterizations, providing detection of anomalous data signatures indicative of system faults or failures. Data-driven techniques have a number of advantages over other methods for monitoring complex space vehicles. Unlike model-based systems, the developer does not need to understand or encode the internal operation of the system. The knowledge required to monitor the system is automatically derived from archived data from system operation. Unlike rule-based systems, data-driven systems do not require system analysts to define nominal relationships among sensors. Analysts can and often do determine these relationships for a system with few sensors; it is more difficult to analytically determine the nominal relationship among a large number of sensors. Data-driven techniques are not limited to low-dimensional spaces and work as effectively with dozens of parameters as they do with a few. Knowledge bases formed by data-driven techniques are also easy to update. As the operating envelope of the monitored system is expanded, data-driven techniques can be quickly retrained to incorporate the new behavior into the knowledge base. The expertise and time-consuming process of updating a model or rule base to maintain consistency with the new operation is not required. The Inductive Monitoring System (IMS) is a data-driven system health monitoring software tool that has been successfully applied to several aerospace applications. IMS uses a data mining technique called clustering to analyze archived system data and characterize normal interactions between parameters. This characterization, or model, of nominal operation is stored in a knowledge base that can be used for real-time system monitoring or analysis of archived events. System data is compared with the nominal IMS model to produce a measure of how well current system behavior matches the normal behavior defined by the training data. Significant deviations from the nominal system model can provide alerts to system malfunctions or precursors of significant failures. The scope of IMS based data-driven monitoring applications continues to expand with current development activities. Successful IMS deployment in the International Space Station (ISS) flight control room to monitor ISS attitude control systems has led to applications in other ISS flight control disciplines, such as thermal control. It has also generated interest in data-driven monitoring capability for Constellation, NASA's program to replace the Space Shuttle with new launch vehicles and spacecraft capable of returning astronauts to the moon, and then on to Mars. Several projects are currently underway to evaluate and mature the IMS technology and complementary tools for use in the Constellation program. These include an experiment on board the Air Force TacSat-3 satellite, and ground systems monitoring for NASA's Ares I-X and Ares I launch vehicles. The TacSat-3 Vehicle System Management (TVSM) project is a software experiment to integrate fault and anomaly detection algorithms and diagnosis tools with executive and adaptive planning functions contained in the flight software on-board the Air Force Research Laboratory TacSat-3 satellite. The TVSM software package will be uploaded after launch to monitor spacecraft subsystems such as power and guidance, navigation, and control (GN&C). It will analyze data in real-time to demonstrate detection of faults and unusual conditions, diagnose problems, and react to threats to spacecraft health and mission goals. The experiment will demonstrate the feasibility and effectiveness of integrated system health management (ISHM) technologies with both ground and on-board experiments. Initially, the TVSM software will run open loop, providing system health information and recommendations to ground operators, without automatically performing fault-mitigating corrective actions. After the end of the satellite's mission, closed loop tests combining TVSM monitoring and diagnosis with reactive capabilities by the flight software will be performed. In addition to monitoring for long periods of actual operation, the experiment will include fault injection into TacSat-3 data as well as commanded operations to test and evaluate automatic ISHM monitoring and recovery under controlled conditions.

Satellites

Evaluation of Various Methods for Determining Bulk Compositions of Chondrules and Other Objects in Petrographic Thin Sections

Studies of many objects in petrographic thin section, such as melt inclusions in igneous rocks, chondrules and Ca-Al rich inclusions in chondritic meteorites, or clasts in lunar and other breccias, require or can benefit from knowledge of their bulk compositions. Given the scarcity of these materials, the reluctance of curators to provide more abundant material, and the extreme difficulty of cleanly separating such objects from their rock matrices, geochemical and cosmochemical studies need the ability to determine their bulk compositions from in situ methods, such as defocused beam analysis, or quantitative chemical mapping by electron beam methods.

Daniel Kent Ross

The Growth of Zeolites A, X and Mordenite in Space

Zeolites are a class of crystalline aluminosilicate materials that form the backbone of the chemical process industry worldwide. They are used primarily as adsorbents and catalysts and support to a significant extent the positive balance of trade realized by the chemical industry in the United States (around $19 billion in 1991). The magnitude of their efforts can be appreciated when one realizes that since their introduction as 'cracking catalysts' in the early 1960's, they have saved the equivalent of 60 percent of the total oil production from Alaska's North Slope. Thus the performance of zeolite catalysts can have a profound effect on the U.S. economy. It is estimated that a 1 percent increase in yield of the gasoline fraction per barrel of oil would represent a savings of 22 million barrels of crude oil per year, representing a reduction of $400 million in the United States' balance of payments. Thus any activity that results in improvement in zeolite catalyst performance is of significant scientific and industrial interest. In addition, due to their 'stability,' uniformity, and, within limits, their 'engineerable' structures, zeolites are being tested as potential adsorbents to purify gases and liquids at the parts-per-billion levels needed in today's electronic, biomedical, and biotechnology industries and for the environment. Other exotic applications, such as host materials for quantum-confined semiconductor atomic arrays, are also being investigated. Because of the importance of this class of material, extensive efforts have been made to characterize their structures and to understand their nucleation and growth mechanisms, so as to be able to custom-make zeolites for a desired application. To date, both the nucleation mechanics and chemistry (such as what are the 'key' nutrients) are, as yet, still unknown for many, if not all, systems. The problem is compounded because there is usually a 'gel' phase present that is assumed to control the degree of supersaturation, and this gel undergoes a continuous 'polymerization' type reaction during nucleation and growth. Generally, for structure characterization and diffusion studies, which are useful in evaluating zeolites for improving yield in petroleum refining as well as for many of the proposed new applications (e.g., catalytic membranes, molecular electronics, chemical sensors) large zeolites (greater than 100 to 1000 times normal size) with minimum lattice defects are desired. Presently, the lack of understanding of zeolite nucleation and growth precludes the custom design of zeolites for these or other uses. It was hypothesized that the microgravity levels achieved in an orbiting spacecraft could help to isolate the possible effects of natural convection (which affects defect formation) and minimize sedimentation, which occurs since zeolites are twice as dense as the solution from which they are formed. This was expected to promote larger crystals by allowing growing crystals a longer residence time in a high-concentration nutrient field. Thus it was hypothesized that the microgravity environment of Earth orbit would allow the growth of large, more defect-free zeolite crystals in high yield.

A Sacco, Jr

Petrogenesis of Lunar Rocks: Rb-Sr Constraints and Lack of H2O

Rb and Sr isotopic data and other chemical data indicate major lunar differentiation at about 4.6 AE (AE = 10 9 years) and very limited subsequent differentiation. The constraints of limited differentiation after 4.6 AE and the apparent lack of H20 on the Moon, when applied to the derivation and petrogenesis of lunar samples, suggest the following: (1) soil samples, breccias, metaclastic rocks, and feldspathic basalts represent mixtures of repeatedly modified clastic material, which was ultimately derived from materials formed during the ~ 4.6 AE differentiation; and (2) mare basalts crystallized from melts which formed by partial melting, and which developed without equilibration between the melt and crystalline residuum.

Arden L Albee

A Survey of Lunar Rock Types and Comparison of the Crusts of Earth and Moon

The principal known types of lunar rocks are briefly reviewed, and their chemical relationships discussed. In the suite of low-KREEP highland rocks, Fe/(Fe + Mg) in the normative mafic minerals increases and the albite content of normative plagioclase decreases as the total amount of normative plagioclase increases, the opposite of the trend predicted by the Bowen reaction principle. Lunar highland samples analyzed are uniformly distributed in this sequence, in which normative plagioclase contents range from ~ 40 percent to ~ 100 percent. The distribution of compositions of rocks from terrestrial layered mafic intrusives is substantially different: here the analyses fall in several discrete clusters (anorthositic rocks, norites, granophyres and ferrogabbros, ultramafics), and the chemical trends noted above are not reproduced. It is suggested that the observed trends in lunar highland rocks could be produced by crystal fractionation in a deep global surface magma system if (1) plagioclase tended to float, upon crystallization, and (2) the magma was kept agitated and well mixed (probably by thermal convection) until crystallization was far advanced and relatively little residual liquid was left. When such a system was finally immobilized, the Fe-, Na-rich residual liquid would produce Fe-rich mafic minerals in the upper levels of the system, but could not much alter the composition of abundant calcic plagioclase. Conversely, the same liquid would produce sodic plagioclase deep in the sequence, but could not much alter the composition of abundant magnesian mafic minerals. After the crustal system solidified, but before extensive cooling had developed a thick, strong lithosphere, mantle convection was able to draw portions of the lunar anorthositic crust down into the mantle in a manner analogous to the present-day behavior of the terrestrial mantle and crust. At depth, the crustal material was heated; KREEP-rich norite was extracted by partial melting and erupted at the surface as a lava, analogous to terrestrial andesite eruptions.

John A Wood

Spacecraft Water Impurity Monitor, a System for Water Quality Analysis on Exploration Missions Beyond Low Earth Orbit

Exploration missions beyond low-earth-orbit (LEO) will require advanced instrumentation to monitor water quality. Traveling beyond LEO means the transfer of water samples to an Earth-based laboratory for detailed analysis is not feasible. Detailed analysis of water composition during exploration is still necessary, because having the capability to determine the specific organic chemical causing a change in total organic carbon (TOC) or the specific metal or ionic species causing a change in conductivity has the potential to inform the crew health and system management decisions. On a new vehicle such as a lunar or Mars surface habitat or a Mars transit vehicle, finding “new” impurities not seen on ISS should be expected. The key is to identify the impurity so the correct action can be taken. On ISS we can measure TOC, conductivity, and other physical properties but do not have the capability for detailed analysis using vehicle instrumentation. This is acceptable because ISS can send samples down to Earth for further analysis and obtain the detailed composition. The Spacecraft Water Impurity Monitor (SWIM) will provide detailed water quality analysis for missions in which sample down mass is not available. SWIM is a system comprising organic and inorganic analysis modules. For organic chemicals, a gas chromatograph mass spectrometer (GCMS) detects and identifies organic impurities. For inorganic species, a capillary electrophoresis capacitively coupled contactless conductivity detection (CE-C4D) system as well as ion specific electrodes detect and identify metal ions and other inorganic salts / acids. The SWIM technology demonstration project has completed a System Requirements Review (SRR) to finalize detection requirements and is currently working to refine vehicle interface requirements for a future technology demonstration. The project also has begun preliminary flight design activities for the core analyzers in the instrument suite.

Water Monitoring

Smart Process Planning for Automated Fiber Placement

Many industries, including aerospace, automotive, wind energy, maritime, and sporting goods, rely on strong, lightweight materials called composites. These materials are made by layering fibers, which can come in the form of narrow strips or wider sheets, and setting them in a polymer matrix. One of the most advanced ways to make these parts is through automated fiber placement, where a machine lays down the fibers in precise patterns. This method can create very efficient and strong designs, but it is complex, expensive, and often depends heavily on the experience of skilled engineers. Today, the design, manufacturing, and inspection stages of composite production are usually handled separately. This separation means that important information, such as how a part will be built or what defects might occur, is not always shared between stages. As a result, parts may not be as lightweight, strong, or defect-free as possible, and the process can take longer and cost more. This research develops a smart process planning system that connects design, manufacturing, and inspection into one continuous process. Built as software that works with existing tools, the system can automatically plan how the fibers are placed, predicting and reducing defects while improving both manufacturability and strength. The system optimizes not only individual layers but also how defects are distributed across all layers, preventing them from stacking up in ways that weaken the final part. It also uses inspection results from completed parts to improve future designs, creating a feedback loop where each stage informs the others. The system was tested by designing a composite panel using this new approach and comparing it to a panel made with state-of-the-art manual planning methods. The results showed that the system could intentionally control where defects appeared and increase the efficiency of the planning process. By unifying design, manufacturing, and inspection, this research shows a way to make advanced composite manufacturing more efficient, consistent, and cost-effective. This approach lowers the barrier to using automated fiber placement and opens the door for its wider adoption not only in aerospace but also in industries such as automotive, wind energy, maritime, and sporting goods, where strong and lightweight structures are essential.

Computer-Aided Process Planning