Search NASA⌕ Search

SEARCH · Search NASA

Results for “Clean room”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Processes to Open the Container and the Sample Catcher of the Hayabusa Returned Capsule in the Planetary Material Sample Curation Facility of JAXA

Japanese spacecraft Hayabusa, which returned from near-Earth-asteroid Itokawa, successfully returned its reentry capsule to the Earth, the Woomera Prohibited Area in Australia in Jun 13th, 2010, as detailed in another paper [1]. The capsule introduced into the Planetary Material Sample Curation Facility in the Sagamihara campus of JAXA in the early morning of June 18th. Hereafter, we describe a series of processes for the returned capsule and the container to recover gas and materials in there. A transportation box of the recovered capsule was cleaned up on its outer surface beforehand and introduced into the class 10,000 clean room of the facility. Then, the capsule was extracted from the box and its plastic bag was opened and checked and photographed the outer surface of the capsule. The capsule was composed of the container, a backside ablator, a side ablator, an electronic box and a supporting frame. The container consists of an outer lid, an inner lid, a frame for latches, a container and a sample catcher, which is composed of room A and B and a rotational cylinder. After the first check, the capsule was packed in a plastic bag with N2 again, and transferred to the Chofu campus in JAXA, where the X-ray CT instrument is situated. The first X-ray CT analysis was performed on the whole returned capsule for confirming the conditions of latches and O-ring seal of the container. The analysis showed that the latches of the container should have worked normally, and that the double Orings of the container seemed to be sealed its sample catcher with no problem. After the first X-ray CT, the capsule was sent back to Sagamihara and introduced in the clean room to exclude the electronic box and the side ablator from the container by hand tools. Then the container with the backside ablator was set firmly to special jigs to fix the lid of container tightly to the container and set to a milling machine. The backside ablator was drilled by the machine to expose heads of bolts, which combined the ablator to the outer lid of the container, and after the drilling had been finished, all the bolts were unscrewed and the backside ablator was removed from the container. Then, the container was sent to the Chofu X-ray facility again to examine in detail by a micro X-ray CT instrument in order to reconfirm that the condition of the latches of the lid of container was normal and that its double O-ring seemed to have been sealed after the last X-ray CT analysis.

Fujimura, A.↗

Installation of the Dark Energy Spectroscopic Instrument at the Mayall 4-meter telescope

The Dark Energy Spectroscopic Instrument (DESI) is a Stage IV ground-based dark energy experiment that will measure the expansion history of the Universe using the Baryon Acoustic Oscillation technique. The spectra of 35 million galaxies and quasars over 14000 square degrees will be measured during the life of the experiment. We describe the installation of the major elements of the instrument at the Mayall 4m telescope, completed in late 2019. The previous prime focus corrector, spider vanes, and upper rings were removed from the Mayall’s Serrurier truss and replaced with the newlyconstructed DESI ring, vanes, cage, hexapod, and optical corrector. The new corrector was optically aligned with the primary mirror using a laser tracker system. The DESI focal plane system was integrated to the corrector, with each of its ten 500-fiber-positioner petal segments installed using custom installation hardware and the laser tracker. Ten DESI spectrographs with 30 cryostats were installed in a newly assembled clean room in the Large Coude Room. The ten cables carrying 5000 optical fibers from the positioners in the focal plane were routed down the telescope through cable wraps at the declination and hour angle axes, and their integral slitheads were integrated with the ten spectrographs. The fiber view camera assembly was installed to the Mayall’s primary mirror cell. Servers for the instrument control system replaced existing computer equipment. The fully integrated instrument has been commissioned and is ready to start its operations phase.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Cleanroom Microbes Survive Drying, Vacuum, and Proton Irradiation

Introduction : The goal of planetary protection at NASA is to mitigate the risk of contaminating sensitive target bodies with biological life. While many cleaning procedures have been put in place to reduce bioburden on spacecraft, microbes are experts at evolving to survive harsh conditions. Specifically, the dry, low-nutrient environment of a cleanroom (commonly used for assembly of spacecraft) can represent an environment where extremophiles can survive. Methods : Scientists at NASA MSFC wished to gather a snapshot of the microbial population within a variety of cleanrooms on site. A study was undertaken to collect air, surface, and floor samples from clean-rooms and isolate unique morphologies. From this study, 95 isolates were collected and saved in a microbial library. About 86% of these were identified at least to a genus level. Following identification, 24 microbes were selected, based on a literature review, as potential extremophiles. These were grown in liquid cultures, diluted to a set optical density, washed with water, and then applied to a sterilized Kapton coupon. Droplets were allowed to dry overnight in a biosafety cabinet. Coupons were then installed in a pelletron and pumped down to high vacuum (~1E-6 Torr). Samples were then subjected 100 keV protons at a fluence of 2x10 15 p+/cm 2 up to 4x10 15 p+/cm 2 . Following exposure, samples were returned to the microbiology lab where they were pro-cessed by submerging in water, vortexing, and then plating either droplets or spread plates. Recovery data collected was qualitative with a ranking or +, minor, or – for growth. Some selected radiotolerant strains were sequenced using the Illumina sequencing platform. The resulting genomes were annotated with the Rapid Annotations using Subsystems Technology (RAST) server and analyzed for conserved and unique stress response relevant genomic signatures to identify clues related to specific tolerances. Results and Discussion : After five rounds of proton radiation, we narrowed our isolates to five, non-spore forming bacteria that demonstrated survival: Arthrobacter koreensis, Paenarthrobacter nitroguajacolicus, Mycetocola manganoxydans , and an Erwinia sp. Furthermore, we exposed these four microbes to 254 nm wavelength light at an intensity of 80 W/m 2 at a distance of ~18 cm for 10 minutes. Only A. koreensis demonstrated survival following UV exposure. Finally, we performed whole genome sequencing on the four strains to look for genetic markers of stress resistance. When we compared the genomes of the four strains, we found that genes coding for GGDEF and EAL domains with PAS/PAC sensors were only found in A. koreensis . These domains, modulated by PAS/PAC sensors, are hypothesized to facilitate survival under drying, desiccation, and proton irradiation. Drying and Desiccation : PAS domains sense hydration changes and modulate GGDEF and EAL domain activity to adjust c-di-GMP levels, enhancing resistance to desiccation. For instance, in Pseudomonas aeruginosa , the PAS domain of RbdA modulates activity under varying hydration conditions, affecting stress responses [1]. Proton Irradiation : Proton irradiation causes oxidative stress, leading to ROS generation. PAS domains detect this stress and modulate GGDEF and EAL domains to manage oxidative stress responses. In Shewanella , EAL domain proteins modulated by PAS sensors help bacteria adapt to extreme conditions [2]. These genes upregulate other stress response genes, protecting membrane function, protein stability, DNA repair, and antioxidant defenses. The modulation of c-di-GMP by PAS domains is crucial for bacterial adaptation to stress conditions, enabling dynamic physio-logical adjustments [3]. Understanding these mechanisms provides insights into bacterial stress responses and strategies for controlling bacterial growth [4]. Conclusions : These findings indicate that clean-rooms harbor extremophile microbes that may be able to survive conditions in deep space. Furthermore, while we identified certain stress-response genes that may be at least partly responsible for the phenotypes observed in this study, there are likely unidentified genes or characteristics about A. koreensis , and other bacteria, that may allow them to survive in harsh environments. Future studies will focus on identifying these unknown genes and characteristics, further elucidating the mechanisms of extremophile survival and potentially informing the development of new biotechnologies for space exploration and other extreme environments.

Chelsi Cassilly↗

STS-37 Payload Gamma Ray Observatory Pad-B in PCR

The primary objective of the STS-37 mission was to deploy the Gamma Ray Observatory. The mission was launched at 9:22:44 am on April 5, 1991, onboard the space shuttle Atlantis. This videotape shows the Gamma Ray Observatory being placed in the payload bay of the shuttle. The Payload Changeout Room (PCR) and the clean room operations required to place the payload in the bay are shown.

Source record↗

Preventing Molecular and Particulate Infiltration in a Confined Volume

Contaminants from an instrument's self-generated sources or from sources external to the instrument may degrade its critical surfaces and/or create an environment which limits the instrument's intended performance. Analyses have been carried out on a method to investigate the required purging flow of clean, dry gas to prevent the ingestion of external contaminants into the instrument container volume. The pressure to be maintained and the required flow are examined in terms of their effectiveness in preventing gaseous and particulate contaminant ingestion and abatement of self-generated contaminants in the volume. The required venting area or the existing volume venting area is correlated to the volume to be purged, the allowable pressure differential across the volume, the external contaminant partial pressure, and the sizes of the ambient particulates. The diffusion of external water vapor into the volume while it was being purged was experimentally obtained in terms of an infiltration time constant. That data and the acceptable fraction of the outside pressure into the volume indicate the required flow of purge gas expressed in terms of volume change per unit time. The exclusion of particulates is based on the incoming velocity of the particles and the exit flow speed and density of the purge gas. The purging flow pressures needed to maintain the required flows through the vent passages are indicated. The purge gas must prevent or limit the entrance of the external contaminants to the critical locations of the instrument. It should also prevent self- contamination from surfaces, reduce material outgassing, and sweep out the outgassed products. Systems and facilities that can benefit from purging may be optical equipment, clinical facilities, manufacturing facilities, clean rooms, and other systems requiring clean environments.

Scialdone, John J.↗

Sterilization facilities

Clean room assembly and sterilization laboratories for experiments on Voyager capsule, components and modules

STERILIZATION↗

Directional Neutron Detection and TPC Developments and LLNL

LLNL is involved with a number of TPC projects spanning basic science to homeland security. This talk outlines the TPC work at LLNL and specifically focuses on the neutron TPC. A number of TPC projects are now underway at Lawrence Livermore National Laboratory (LLNL) and there is currently a ramp up in the infrastructure both in equipment and people to support these efforts. In place are high pressure vessels for xenon studies up to 50bar, larger vessels up to 100 litters at 10bar, clean room facilities, extensive electronics development, dedicated lab space and a assortment of radioactive sources.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

A top loading 2 Kelvin test cryostat for SRF cavities.

A new large 2 Kelvin test cryostat is being commissioned at Argonne National Laboratory. This system will have a full time connection to the 4.5 Kelvin ATLAS refrigerator and, with integrated J-T heat exchanger, will allow continuous 2 Kelvin operation. The large diameter was chosen to accommodate essentially all of today's superconducting cavities and the top loading design facilitates clean room assembly. The commissioning run will be with a coaxial half wave cavity to be followed by testing with 1.3 GHz single-cell elliptical cavities. Details of the initial engineering cool down on the cryostat are presented.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Design and Construction of an Ultra-Low-Background 14 Crystal Germanium Array for High Efficiency and Coincidence Measurements

ABSTRACT Physics experiments, environmental surveillance, and treaty verification techniques continue to require increased sensitivity for detecting and quantifying radionuclides of interest. This can be done by detecting a greater fraction of gamma emissions from a sample (higher detection efficiency) and reducing instrument backgrounds. A current effort for increased sensitivity in high resolution gamma spectroscopy will produce an intrinsic germanium (HPGe) array designed for high detection efficiency, ultra-low-background performance, and useful coincidence efficiencies. The system design is optimized to accommodate filter paper samples, e.g. samples collected by the Radionuclide Aerosol Sampler/Analyzer (RASA). The system will provide high sensitivity for weak collections on atmospheric filter samples, as well as offering the potential to gather additional information from more active filters using gamma cascade coincidence detection. The current effort is constructing an ultra-low-background HPGe crystal array consisting of two vacuum cryostats, each housing a hexagonal array of 7 crystals on the order of 70% relative efficiency per crystal. Traditional methods for constructing ultra-low-background detectors are used, including use of materials known to be low in radioactive contaminants, use of ultra pure reagents, clean room assembly, etc. The cryostat will be constructed mainly from copper electroformed into near-final geometry at PNNL. Details of the detector design, simulation of efficiency and coincidence performance, HPGe crystal testing, and progress on cryostat construction are presented.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

A radon progeny deposition model

The next generation low-background detectors operating underground aim for unprecedented low levels of radioactive backgrounds. Although the radioactive decays of airborne radon (particularly {sup 222}Rn) and its subsequent progeny present in an experiment are potential backgrounds, also problematic is the deposition of radon progeny on detector materials. Exposure to radon at any stage of assembly of an experiment can result in surface contamination by progeny supported by the long half life (22 y) of {sup 210}Pb on sensitive locations of a detector. An understanding of the potential surface contamination from deposition will enable requirements of radon-reduced air and clean room environments for the assembly of low background experiments. It is known that there are a number of environmental factors that govern the deposition of progeny onto surfaces. However, existing models have not explored the impact of some environmental factors important for low background experiments. A test stand has been constructed to deposit radon progeny on various surfaces under a controlled environment in order to develop a deposition model. Results from this test stand and the resulting deposition model are presented.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Electropolishing at ANL/FNAL.

A system for electropolishing of 1.3 GHz elliptical single- and nine-cell cavities is in operation at the joint ANL/FNAL cavity processing facility located at Argonne. The system is one peice of a larger 200 m2 complete single cavity processing and assembly facility which also includes clean rooms and high-pressure rinsing. Recently, the electropolishing system has been used to process a series of single and nine-cell cavities. For single cell cavities a good set of EP parameters has been demonstrated based on more than a half dozen complete processing and cold test cycles at ANL/FNAL. The lastest six single cell cavities each exceed EACC=35 MV/m and, at this gradient, have Q in the range 6 10{sup 9} - 1 10{sup 10}. The first nine cell cavities electropolished at ANL have not yet reached similar fields ({approx}23 MV/m-26 MV/m) and ongoing activities are focussed on demonstrating >30 MV/m in these cavities. Suitable nine cell EP parameters using the ANL/FNAL EP system including acid/water temperatures, flow rates, current, voltage, air flow etc. are all substantially different than for single-cell cavities and are discussed here.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗