Search NASA⌕ Search

SEARCH · Search NASA

Results for “Cold Spray”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

88 records · Page 5

Measurements of temperature and pressure fluctuations in the T prime 2 cryogenic wind tunnel

Cold wire measurement of temperature fluctuations were made in a DERAT T'2 induction powered cryogenic wind tunnel for 2 types of liquid nitrogen injectors. Thermal turbulence measured in the tranquilization chamber depends to a great extent on the injector used; for fine spray of nitrogen drops, this level of turbulence seemed completely acceptable. Fluctuations in static pressure taken from the walls of the vein by Kulite sensors showed that there was no increase in aerodynamic noise during cryogenic gusts.

Blanchard, A.↗

Effectiveness of the Space Shuttle anti-exposure system in a cold water environment

The purpose of this study was to evaluate the NASA Space Shuttle launch entry suit (LES) and raft for 24 h of protection against cold water immersion. Two configurations, the LES and the LES with raft (LES/r) were evaluated for antiexposure protection. Conditions were selected to simulate worst-case water and air temperatures along projected Space Shuttle ground tracks; i.e., water temperatures = 4.4 C, air temperature = 5.6 C, 1-foot waves (chop), and constant spray. Four males 31-44 years of age and one 32-year-old female were studied once in each configuration. Trials with and without a raft were scheduled for up to 24 and 6 h, respectively. Mean LES trial durations were 150 + or - 9 min and final rectal temperature (FRT) = 36.5 + or - 0.3 C. Mean LES/r trial durations were 398 + or - 126 min and FRT = 35.6 + or - 0.4 C. LES and LES/r trials were terminated for reaching FRT = 35.0 C or subject-requested termination due to discomfort. The longest LES and LES/r trials were terminated due to subject discomfort. Although not achieving the desired durations, the LES and LES/r did prove capable of protecting individuals, respectively, for up to 3 and 13.5 h. Since the longest runs were terminated due to subjective tolerance, actual survival times greater than 3 and 13.5 h could be expected.

Bagian, James P.↗

Atomizing characteristics of swirl can combustor modules with swirl blast fuel injectors

Cold flow atomization tests of several different designs of swirl can combustor modules were conducted in a 7.6 cm diameter duct at airflow rates (per unit area) of 7.3 to 25.7 g/sq cm sec and water flow rates of 6.3 to 18.9 g/sec. The effect of air and water flow rates on the mean drop size of water sprays produced with the swirl blast fuel injectors were determined. Also, from these data it was possible to determine the effect of design modifications on the atomizing performance of various fuel injector and air swirler configurations. The trend in atomizing performance, as based on the mean drop size, was then compared with the trends in the production of nitrogen oxides obtained in combustion studues with the same swirl can combustors. It was found that the fuel injector design that gave the best combustor performance in terms of a low NOx emission index also gave the best atomizing performance as characterized by a spray of relatively small mean drop diameter. It was also demonstrated that at constant inlet air stream momentum the nitrogen oxides emission index was found to vary inversely with the square of the mean drop diameter of the spray produced by the different swirl blast fuel injectors. Test conditions were inlet air static pressures of 100,000 to 200,000 N/sq m at an inlet air temperature of 293 K.

Ingebo, R. D.↗

Atomizing characteristics of swirl can combustor modules with swirl blast fuel injectors

Cold flow atomization tests of several different designs of swirl can combustor modules were conducted in a 7.6 cm diameter duct at airflow rates (per unit area) of 7.3 to 25.7 g/sq cm sec and water flow rates of 6.3 to 18.9 g/sec. The effect of air and water flow rates on the mean drop size of water sprays produced with the swirl blast fuel injectors were determined. Also, from these data it was possible to determine the effect of design modifications on the atomizing performance of various fuel injector and air swirler configurations. The trend in atomizing performance, as based on the mean drop size, was then compared with the trends in the production of nitrogen oxides obtained in combustion studies with the same swirl can combustors.

Ingebo, R. D.↗

Large Engine Technology Program. Task 22: Variable Geometry Concepts for Rich-Quench-Lean Combustors

The objective of the task reported herein was to define, evaluate, and optimize variable geometry concepts suitable for use with a Rich-Quench-Lean (RQL) combustor. The specific intent was to identify approaches that would satisfy High Speed Civil Transport (HSCT) cycle operational requirements with regard to fuel-air ratio turndown capability, ignition, and stability margin without compromising the stringent emissions, performance, and reliability goals that this combustor would have to achieve. Four potential configurations were identified and three of these were refined and tested in a high-pressure modular RQL combustor rig. The tools used in the evolution of these concepts included models built with rapid fabrication techniques that were tested for airflow characteristics to confirm sizing and airflow management capability, spray patternation, and atomization characterization tests of these models and studies that were supported by Computational Fluid Dynamics analyses. Combustion tests were performed with each of the concepts at supersonic cruise conditions and at other critical conditions in the flight envelope, including the transition points of the variable geometry system, to identify performance, emissions, and operability impacts. Based upon the cold flow characterization, emissions results, acoustic behavior observed during the tests and consideration of mechanical, reliability, and implementation issues, the tri-swirler configuration was selected as the best variable geometry concept for incorporation in the RQL combustor evolution efforts for the HSCT.

Tacina, Robert R.↗

Combustion of LOX with H2(sub g) under subcritical, critical, and supercritical conditions (Task 1) and experimental observation of dense spray and mixing of impinging jets (Task 2)

The objective was to achieve a better understanding of the combustion processes of liquid oxygen and gaseous hydrogen under broad range of pressure covering subcritical, critical, and supercritical conditions. The scope of the experimental work falls into the following areas: (1) design of the overall experimental setup; (2) modification of an existing windowed high pressure chamber; (3) design of the LOX feeding system; (4) provision of the safety features in the test rig design; (5) LOX cleanliness requirements; (6) cold shock testing; (7) implementation of data acquisition systems; (8) preliminary tests for system checkout; (9) modification of LOX feeding system; and (10) evaporation tests. Progress in each area is discussed.

Kuo, K. K.↗

On the association of erupting magnetic fields with eruptive prominences and coronal mass ejections

A number of space and ground-based observations give evidence that the eruptive prominences, coronal mass ejections (CMEs) and associated shocks are generated by a common cause, i.e., the eruption of the magnetic field on the Sun. Some 60% of the observed CMEs are associated with the eruptive prominences. It is believed that in reality a much better correlation should be between these events because of observational limitations and of the effect of partial eruption. Some recent results on the formation and evolution of the quiescent and the active region prominences give an idea on the early phase of eruption of the magnetic field with the prominence plasma frozen in. In the latter phase of eruption the magnetic field lifted high into the corona and is seen (as manifested by the cold plasma frozen in) as a system of huge loops - evidently the result of some reconnections at lower heights. The legs of these erupting loops interact sometimes with the local magnetic field, i.e., it often appears to be an active region. In consequence of this interaction the activation of prominences and generation of flares can take place on some occasions as well as ejection of surges and sprays.

Rompolt, Bogdan↗

Spray automated balancing of rotors: Methods and materials

The work described consists of two parts. In the first part, a survey is performed to assess the state of the art in rotor balancing technology as it applies to Army gas turbine engines and associated power transmission hardware. The second part evaluates thermal spray processes for balancing weight addition in an automated balancing procedure. The industry survey reveals that: (1) computerized balancing equipment is valuable to reduce errors, improve balance quality, and provide documentation; (2) slow-speed balancing is used exclusively, with no forseeable need for production high-speed balancing; (3) automated procedures are desired; and (4) thermal spray balancing is viewed with cautious optimism whereas laser balancing is viewed with concern for flight propulsion hardware. The FARE method (Fuel/Air Repetitive Explosion) was selected for experimental evaluation of bond strength and fatigue strength. Material combinations tested were tungsten carbide on stainless steel (17-4), Inconel 718 on Inconel 718, and Triballoy 800 on Inconel 718. Bond strengths were entirely adequate for use in balancing. Material combinations have been identified for use in hot and cold sections of an engine, with fatigue strengths equivalent to those for hand-ground materials.

Smalley, Anthony J.↗

Cold-Flow Testing of a Proposed Integrated Center-Body Diffuser/Steam Blocker Concept for Plum Brook Station's B-2 Test Facility

The center-body diffuser (CBD) steam blocker (SB) system is a concept that incorporates a set of secondary drive nozzles into the envelope of a CBD, such that both nozzle systems (i.e., the rocket engine and the steam blocking nozzles) utilize the same supersonic diffuser, and will operate either singularly or concurrently. In this manner, the SB performs as an exhaust system stage when the rocket engine is not operating, and virtually eliminates discharge flow on rocket engine shutdown. A 2.25-percent scale model of a proposed SB integrated into a diffuser for the Plum Brook B-2 facility was constructed and cold-flow tested for the purpose of evaluating performance characteristics of various design options. These specific design options addressed secondary drive nozzle design (method of steam injection), secondary drive nozzle location relative to CBD throat, and center-body throat length to diameter (L/D) ratios. The objective of the test program is to identify the desired configuration to carry forward should the next phase of design proceed. The tested scale model can provide data for various pressure ratios; however, its design is based on a proposed B-2 spray chamber (SC) operating pressure of 4.0 psia and a steam supply pressure of 165 psia. Evaluation of the test data acquired during these tests indicate that either the discrete axial or annular nozzle configuration integrated into a CBD, with an annular throat length of 1.5 L/D at the nominal injection position, would be suitable to carry forward from the SB's perspective. Selection between these two then becomes more a function of constructability and implementation than performance. L/D also has some flexibility, and final L/D selection can be a function of constructability issues within a limited range.

Edwards, Daryl A.↗

Icing of flow conditioners in a closed-loop wind tunnel

Described are the results of an experiment which determined whether flow conditioning screens and honeycombs would ice up in a closed-loop icing wind tunnel when placed downstream of the heat exchanger and upstream of the spray bars. The experiment was performed in the Icing Research Tunnel (IRT) at NASA Lewis Research Center. The investigation involved two separate tests: one to find the icing characteristics of flow conditioners in the IRT, and the second to find the icing characteristics of flow conditioners in the proposed rehabilitation of the Altitude Wind Tunnel (AWT). Both experiments showed that the heat exchanger removed nearly all of the icing cloud so that icing of the flow conditioners would cause no serious tunnel performance degradation during the course of a day's run. Only extremely cold conditions caused frost formation on the flow conditioners. The significance of this frost formation was minimized because frost buildup on the heat exchanger caused a much more severe pressure drop than did icing of the flow conditioners.

Newton, James E.↗

Sulfur and Moisture Effects on Alumina Scale and TBC Spallation

It has been well established that a few ppmw sulfur impurity may segregate to the interface of thermally grown alumina scales and the underlying substrate, resulting in bond degradation and premature spallation. This has been shown for NiAl and NiCrAl-based alloys, bare single crystal superalloys, or coated superalloys. The role of reactive elements (especially Y) has been to getter the sulfur in the bulk and preclude interfacial segregation. Pt additions are also very beneficial, however a similar thermodynamic explanation does not apply. The purpose of the present discussion is to highlight some observations of these effects on Rene'142, Rene'N5, PWA1480, and PWA1484. For PWA1480, we have mapped cyclic oxidation and spallation in terms of potential sulfur interfacial layers and found that a cumulative amount of about one monolayer is sufficient to degrade long term adhesion. Depending on substrate thickness, optimum performance occurs if sulfur is reduced below about 0.2-0.5 ppmw. This is accomplished in the laboratory by hydrogen annealing or commercially by melt-fluxing. Excellent 1150 C cyclic oxidation is thus demonstrated for desulfurized Rene'142, Rene'N5, and PWA1484. Alternatively, a series of N5 alloys provided by GE-AE have shown that as little as 15 ppmw of Y dopant was effective in providing remarkable scale adhesion. In support of a Y-S gettering mechanism, hydrogen annealing was unable to desulfurize these alloys from their initial level of 5 ppmw S. This impurity and critical doping level corresponds closely to YS or Y2S3 stoichiometry. In many cases, Y-doped alloys or alloys with marginal sulfur levels exhibit an oxidative sensitivity to the ambient humidity called Moisture-Induced Delayed Spallation (MIDS). After substantial scale growth, coupled with damage from repeated cycling, cold samples may spall after a period of time, breathing on them, or immersing them in water. While stress corrosion arguments may apply, we propose that the underlying cause is related to a hydrogen embrittlement reaction: Al alloy + 3 H2O = Al(OH)3 + 3H(+) + 3e(-). This mechanism is derived from an analogous moisture-induced hydrogen embrittlement mechanism originally shown for Ni3Al and FeAl intermetallics. Consequently, a cathodic hydrogen charging technique was used to demonstrate that electrolytic de-scaling occurs for these otherwise adherent alumina scales formed on Y-doped Rene'N5, in support of hydrogen effects. Finally, some TBC observations are discussed in light of all of the above. Plasma sprayed 8YSZ coatings, produced on PWA1484 without a bond coat, were found to survive more than 1000 1-hr cycles at 1100 C when desulfurized to below 0.1 ppmw. At higher sulfur (1.2 ppmw) levels, moisture sensitivity and delayed TBC failure, referred to as Desk Top Spallation, occurred at just 200 hr. Despite a large degree of scatter, a factor of 5 in life improvement is indicated for desulfurized samples in cyclic furnace tests, confirming the beneficial effect of low sulfur alloys on model TBC systems. (DTS and moisture effects are also observed on commercially applied PVD 7YSZ coatings on Rene'N5+Y with Pt-aluminide bond coats). These types of catastrophic failure were subverted on the model system by segmenting the substrate into a network of 0.010 high ribs, spaced in. apart, prior to plasma spraying. No failures occurred after 1000 cycles at 1150 C or after 2000 cycles at 1100 C, even after water immersion. The benefit is described in terms of elasticity models and a critical buckling stress.

Smialek, James L.↗

Numerical Modeling of No Vent Filling of a Cryogenic Tank with Thermo-dynamic Vent System Assisted Injector

This paper presents a multi-node finite volume model of No Vent Filling (NVF) of a cryogenic tank with Thermo-dynamic Vent System (TVS) assisted injector, using the Generalized Fluid System Simulation Program (GFSSP), a general purpose flow network code. NVF tests were conducted in a CRYOgenic Orbital Testbed (CRYOTE) tank which was filled by liquid nitrogen using a TVS assisted injector with vent valve closed during the entire filling process. In TVS assisted injector, the liquid flow splits into two streams: one stream is routed to a Joule-Thomson (J-T) orifice where the flow immediately flashes from liquid to vapor or two phase mixture because the downstream to J-T leg is maintained at vacuum level.; the other stream is injected into the tank after being cooled by cold vapor of J-T leg in a heat exchanger. The flow through J-T leg is also used to cool the outer metal matrix of the injector which in turn cools the vapor in the tank ullage. The cooling of vapor in the ullage by cold injector surface reduces ullage pressure that allows liquid to enter and fill the tank. An integrated numerical model of the test set up was developed. The model included the dual lines of TVS assisted injector, tank and tank wall. The tank was discretized into multiple fluid nodes and branches to represent the ullage and liquid nitrogen and multiple solid nodes to represent the tank wall and structure. The heat transfer between solid to fluid was calculated from pool boiling correlations which include film, transition, and nucleate boiling, as well as natural convection during pre- and post-boiling. The model also accounts for the condensation of vapor at ullage-injector interface and when it comes in contact with the liquid spray. The predicted pressure, resident mass, wall temperature in the tank were compared with the test data.

Alok Majumdar↗

Numerical Simulation of Lean Blowout of Alternative Fuels in 7-element Lean Direct Injector

This research presents the result of numerically simulating 7-element swirl-venturi Lean Direct Injector (SV-LDI) lean blowout (LBO) experiments conducted at NASA Glenn Research Center in May of 2019. After simulating a cold flow case to confirm the pressure drop agrees well with the experiment, additional cases with two different fuels (an average jet fuel and a Gevo alcohol-to-jet fuel) from the National Jet Fuels Combustion Program (NJFCP) were computed to numerically determine the LBO condition. The procedure to approach the LBO follows the method used in the experiment where the air mass flow rate is gradually increased while the fuel supply is maintained. Transient history of global heat release rate as a function of air flow rate is presented, as well as temperature contours at different conditions to give a visual representation of the flame state. The Open National Combustion Code (OpenNCC) used in this research adopted reduced HyChem (Hybrid Chemistry) models along with k-LES turbulence model and a Lagrangian spray model that takes into account droplet internal temperature distribution affected by the shear force on the droplet surface. The transport equations and chemical reaction terms are integrated together to enhance conservation of chemical species that are especially important in the near LBO conditions. After showing the computed range of LBO agrees well with the experimental measurements, time averaged solutions of both fuels at their initial condition and at their limiting condition just before LBO are compared in detail to facilitate the understanding of LBO mechanism.

combustion↗

Coating Development for GRCop-84 Liners for Reusable Launch Vehicles Aided by Modeling Studies

The design of the next generation of reusable launch vehicles calls for using GRCop-84 copper alloy liners based on a composition invented at the NASA Glenn Research Center. Despite its considerable advantage over other copper alloys, it is expected that GRCop-84 will suffer from environmental degradation depending on the type of rocket fuels used and on thermomechanical fatigue. Applying protective coatings on GRCop-84 substrates can minimize or eliminate many of these problems and extend the operational life of the combustion liner. This could increase component reliability, shorten depot maintenance turnaround times, and lower operating costs. Therefore, Glenn is actively pursuing the development of advanced coatings technology for GRCop-84 liners. Technology is being developed in four major areas: (1) new metallic coating compositions, (2) application techniques, (3) test methods, and (4) life prediction design methodology using finite element analysis. The role of finite element analysis in guiding the coating effort is discussed in this report. Thermal analyses were performed at Glenn for different combinations of top- and bondcoat compositions to determine the temperature variation across the coated cross section with the thickness of the top coat. These calculations were conducted for simulated LH2/LO2 booster engine conditions assuming that the bond coat had a constant thickness of 50 m. The preceding graphs show the predicted temperatures at the outer surface of the top coat (hot wall), at the top-coat/bond-coat interface, at the bond-coat/GRCop-84 interface, and at the GRCop-84 cold wall as a function of top-coat thickness for Cu- 26(wt%)Cr top coat (top graph), Ni-17(wt%)Cr-6%Al-0.5%Y top coat and Cu-26%Cr bond coat, and NiAl top coat and Ni bond coat. In all cases, the temperature of the top coat at the hot wall increased with increasing top-coat thickness and with corresponding decreases in the temperatures at the two interfaces and the cold wall. These temperatures are not acutely sensitive to the thermal conductivity of the top coat when it exceeds 25 and 50 W/m/K for low and high heat flux engines. This observation is significant for two reasons. First, several different top-coat compositions can be evaluated as potential protective coatings without loss in the heat-transfer efficiency of the coated system. Second, materials with thermal conductivities less than the critical values of 25 or 50 W/m/K are more likely to act as thermal barrier coatings. The deposition of overlay coatings on GRCop-84 substrates results in the development of residual stresses. The presence of these residual stresses influences the probability of coating spallation, the thermal cycling life, and the fatigue properties of the coated substrate during use. Since it is important to understand how these stresses develop during the vacuum-plasma-spraying coating deposition process, the nature and magnitudes of the cool-down residual stresses were calculated and compared with experimentally determined values across the coated cross section of a disk specimen. The calculations were conducted assuming that the specimen cools down to room temperature from vacuum plasma-spraying temperatures of either 250 or 650 C. The effects of coating the substrate with and without grit blasting were also theoretically examined. The final graph compares the predicted and the experimental results for a GRCop-84 disk coated with about a 50- m-thick Ni bond coat and a 75- to 100- m NiAl top coat, where the curves for NASA-2 assume the presence of a prior residual stress generated by grit blasting under conditions similar to the experimental situation. The predicted cool-down in-plane stresses were compressive in both the NiAl top coat and the Ni bond coat. They were also compressive in the substrate to a depth of about 0.25 mm from the Ni/GRCop-84 interface when the vacuum-plasma-spraying temperature was low. However, using a higher plasma spraying temperaturs likely to leave the substrate under a small tensile stress to counter the compressive stresses in the bond and top coats because of the relaxation of residual stresses generated in the substrate during the grit blasting of its surface prior to spraying. These results suggest that the NiAl and Ni coatings are unlikely to spall after spraying as confirmed by the microstructural observations shown in the following photomicrograph of an as-sprayed specimen. Finally, it is noted that the calculated and experimental results are not in complete agreement, which indicates that both the experimental and modeling techniques need further refinement.

Raj, Sai V.↗

Spray-On Foam Insulations for Launch Vehicle Cryogenic Tanks

Spray-on foam insulation (SOFI) has been developed for use on the cryogenic tanks of space launch vehicles beginning in the 1960s with the Apollo program. The use of SOFI was further developed for the Space Shuttle program. The External Tank (ET) of the Space Shuttle, consisting of a forward liquid oxygen tank in line with an aft liquid hydrogen tank, requires thermal insulation over its outer surface to prevent ice formation and avoid in-flight damage to the ceramic tile thermal protection system on the adjacent Orbiter. The insulation also provides system control and stability with throughout the lengthy process of cooldown, loading, and replenishing the tank. There are two main types of SOFI used on the ET: acreage (with the rind) and closeout (machined surface). The thermal performance of the seemingly simple SOFI system is a complex of many variables starting with the large temperature difference of from 200 to 260 K through the typical 25-mm thickness. Environmental factors include air temperature and humidity, wind speed, solar exposure, and aging or weathering history. Additional factors include manufacturing details, launch processing operations, and number of cryogenic thermal cycles. The study of the cryogenic thermal performance of SOFI under large temperature differentials is the subject of this article. The amount of moisture taken into the foam during the cold soak phase, termed Cryogenic Moisture Uptake, must also be considered. The heat leakage rates through these foams were measured under representative conditions using laboratory standard liquid nitrogen boiloff apparatus. Test articles included baseline, aged, and weathered specimens. Testing was performed over the entire pressure range from high vacuum to ambient pressure. Values for apparent thermal conductivity and heat flux were calculated and compared with prior data. As the prior data of record was obtained for small temperature differentials on non-weathered foams, analysis of the different methods is provided. Recent advancements and applications of SOFI systems on future launch vehicles and spacecraft are also addressed.

Fesmire, J. E.↗

Passive Cooling in Aerogel-Based Insulation Systems for Liquid Hydrogen Upper Stage Launch Vehicle Tanks

Spray-On Foam Insulation (SOFI) is typically used to protect the windward-facing side of flight tanks for space launch vehicle liquid hydrogen (LH2) stages. SOFI is an excellent insulator in ambient pressure environments, however, its performance pales in comparison to reflective-type systems such as Multi-Layer Insulation in the thermal radiation dominated vacuum environment of space. If a windward insulation system employing radiation shields could be devised to replace or supplement SOFI, the on-orbit heat load could be drastically reduced, and the residual propellants could then be used to facilitate secondary missions. Such insulation systems, utilizing aerogel blanket insulation, have been explored by the Cryogenics Test Laboratory at NASA Kennedy Space Center. Owing to its nano-porous structure, aerogel is an excellent adsorbent as well as an insulator at cryogenic temperatures and will readily uptake condensable background gasses such as air when protecting a surface near LH2 temperatures. When an adsorbed blanket is rapidly exposed to a vacuum, such as during the ascent of a rocket, it will release the background gas, producing a passive cooling effect that could potentially reduce or eliminate the heat load on the propellant tank for a time. This work discusses the setup and results of a test program carried out to determine the effectiveness and impact of this cooling effect as it pertains to LH2 upper stage tanks. A vertical-cylindrical liquid nitrogen (LN2) calorimeter test instrument acted as the upper stage analog. The cold-mass was wrapped with two layers of 10 mm thick aerogel blanket material, with and without aluminum heat shields depending on the test, and interspersed with numerous thermocouple temperature sensors. Gaseous argon was used as a stand-in for air as the condensable background gas. The test procedure mimicked vehicle cryo-loading/stabilization, and ascent phases, with the ascent phase accomplished using parallel vacuum pumps. Results show that the desorption cooling effect was enough to not only eliminate the heat load on the LN2 cold-mass entirely, but further refrigerated the liquid below its boiling point.

A.M. Swanger↗