Search NASA⌕ Search

SEARCH · Search NASA

Results for “Communication costs”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Virtual Power Plants: Pilots, Challenges, and Innovations Shaping Future Development

Virtual Power Plants (VPPs) aggregate distributed energy resources (DERs) to provide grid services traditionally delivered by centralized power plants. This article reviews the current state of VPP deployment, highlighting business models, compensation mechanisms, and global pilot projects. While VPPs offer benefits such as grid flexibility, resilience, and cost savings, challenges remain in communication infrastructure, regulatory frameworks, market access, and customer engagement. To address these, we propose a scalable, privacy-preserving hierarchical VPP architecture that coordinates with distribution utilities and preserves customer data. We also present the Integrated T&D Control Room of the Future as a key test bed for validating and accelerating VPP adoption. These innovations can help transition VPPs from pilot programs to integral components of a modern, reliable power grid.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Study of Communication Boundaries of Primal-Dual Based Distributed Energy Resource Management Systems (DERMS): Preprint

As the coordination of distributed energy resources (DERs) becomes more necessary to provide grid services through a distributed energy resources management system (DERMS), studying the communication requirements for successful real-world low-cost implementation becomes increasingly important. Specifically, this paper studies the needed communication time resolutions between the different system components for a primal-dual based DERMS which is a highly-developed DERMS framework. We design a metric to evaluate the functionality of a DERMS with respect to providing grid services. Using numerical simulations based on a real-world feeder in Colorado, we show that the upper bound on the time resolutions is on the order of minutes instead of the previously assumed order of seconds.

communication time resolution↗

Study of Communication Boundaries of Primal-Dual-Based Distributed Energy Resource Management Systems (DERMS)

As the coordination of distributed energy resources becomes more necessary to provide grid services through a distributed energy resource management system (DERMS), studying the communication requirements for successful real-world, low-cost implementation becomes increasingly important. Specifically, this paper studies the necessary communication time resolutions between the different system components for a primal-dual-based DERMS, a highly developed DERMS framework. We design a metric to evaluate the functionality of a DERMS with respect to providing grid services. Using numerical simulations based on a real-world feeder in Colorado, we show that the upper bound on the time resolutions is on the order of minutes instead of the previously assumed order of seconds.

communication time resolution↗

Comparison of Sequence Component-Based Fault Detection and Relay Coordination Algorithms in Inverter-Based Networks

Protection of inverter-based microgrids using sequence component-based relaying schemes is a promising solution. These methods offer several advantages, including lower computational requirements, compatibility with commercial relay systems, and cost-effectiveness compared to communication-based approaches. This article investigate the performance of various sequence component based schemes with the objective of identifying the algorithms that provide the best fault detection and relay coordination, solely relying on local voltages and current at relay terminals. Positive, negative and zero sequence impedance, admittance and power detection algorithms were tested on modified IEEE 13 bus test network for various shunt faults (LG, LL, LLG, LLL). Hardware-in-the-loop validation was achieved using the Typhoon real-time simulator, interfacing with a SEL 751 relay. This research demonstrates that while several algorithms are capable of detecting faults with sufficient accuracy, only a few are effective in achieving proper coordination. Validation results indicate that the negative sequence power approach provides the best performance in both fault detection and coordination.

Patel, Deepika [ORNL] (ORCID:0000000341099994)↗

Measurement placement in electric power transmission and distribution grids: Review of concepts, methods, and research needs

Sensing and measurement systems are quintessential to the safe and reliable operation of electric power grids. Their strategic placement is of ultimate importance because it is not economically viable to install measurement systems on every node and branch of a power grid, though they need to be monitored. An overwhelming number of strategies have been developed to meet oftentimes multiple conflicting objectives. The prime challenge in formulating the problem lies in developing a heuristic or an optimisation model that, though mathematically tractable and constrained in cost, leads to trustworthy technical solutions. Further, large-scale, long-term deployments pose additional challenges because the boundary conditions change as technologies evolve. For instance, the advent of new technologies in sensing and measurement, as well as in communications and networking, might impact the cost and performance of available solutions and shift initially set conditions. Also, the placement strategies developed for transmission grids might not be suitable for distribution grids, and vice versa, because of unique characteristics; therefore, the strategies need to be flexible, to a certain extent, because no two power grids are alike. Despite the extensive literature on the present topic, the focus of published works tends to be on a specific subject, such as the optimal placement of measurements to ensure observability in transmission grids. There is a dearth of work providing a comprehensive picture for developing optimal placement strategies. Because of the ongoing efforts on the modernisation of electric power grids, there is a need to consolidate the status quo while exposing its limitations to inform policymakers, industry stakeholders, and researchers on the research-and-development needs to push the boundaries for innovation. Accordingly, this paper first reviews the state-of-the-art considering both transmission and distribution grids. Then, it consolidates the key factors to be considered in the problem formulation. Finally, it provides a set of perspectives on the measurement placement problem, and it concludes with future research directions.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Risk Analysis for Remote Operation of Microreactors

Microreactors are a subset of advanced nuclear reactors that can be factory fabricated, transportable, and self-regulating. They have the potential to be used in microgrids, rural and remote areas, or emergency response applications, replacing fossil fuel sources like diesel generators and enabling sustainable energy generation. In order to make microreactor operation cost-effective, it is likely that remote communications will be needed to reduce the number of personnel required to be on site. While remote operation of energy generation and other industrial control systems is common in other industries, it is not yet adopted in the nuclear community and has many perceived and actual risks. In this paper, the severity of the risks introduced by remote operations for microreactors are explored. The primary changes in the operations involve the addition of a remote communications network and a certification system for data and controls. These changes lend themselves to considerations of cyber risks, whether unintentional or adversarial, but the assessment considers not just cyber risks introduced, but also how physical and human factors-based risks will impact the remote operations system and change the overall risk profile. This initial assessment indicates that there are standard cyber and mitigation measures that can be put in place so the risk of doing remote operations does not dramatically increase compared to local operations. This evaluation is a critical step in the process of evaluating if remote operations of microreactors is a suitable solution to meet future sustainable grid needs

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Distributed optimization and control for autonomous distributed energy resource power dispatch and frequency regulation considering communication failures

Distributed energy resources (DERs) can significantly enhance grid flexibility by supplying power and secondary frequency regulation (SFR) services. Yet, their large number and dispersed nature limit the effectiveness of traditional centralized power dispatch and frequency control schemes, and expose the system to single-point communication failures. This paper presents a unified distributed optimization and control framework for DER power dispatch and SFR provision. A transmission-loss-aware distributed direct current optimal power flow is first formulated to optimize DER power dispatch and reserve scheduling. On top of this, a fully distributed control scheme for DER autonomous SFR provision is developed to allocate automatic generation control signals cost-effectively while ensuring robustness to communication link disruptions. The framework is validated on IEEE 14-bus and 39-bus transmission systems with large-scale distribution feeders using transmission-distribution dynamic co-simulation, demonstrating reliable and autonomous DER power dispatch and SFR provision under diverse operating conditions and communication contingencies.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Study of Communication Boundaries of Primal-Dual Based Distributed Energy Resource Management Systems (DERMS)

As the coordination of distributed energy re-sources becomes more necessary to provide grid services through a distributed energy resource management system (DERMS), studying the communication requirements for suc-cessful real-world, low-cost implementation becomes increasingly important. Specifically, this paper studies the necessary communication time resolutions between the different system components for a primal-dual-based DERMS, a highly de-veloped DERMS framework. We design a metric to evaluate the functionality of a DERMS with respect to providing grid services. Using numerical simulations based on a real-world feeder in Colorado, we show that the upper bound on the time resolutions is on the order of minutes instead of the previously assumed order of seconds.

communication time resolution↗

3-D Printed Electro-Magnetic Objects for THz Communications

Advanced materials and manufacturing techniques will pave the path towards high quality electro-magnetic circuits that operate up through THz and into optics regime. Digital additive manufacturing (AM) techniques offer game-changing potential for large scale manufacturing of Radio-frequency (RF) circuits and system in custom 2D/3D geometries. The technical collaboration will explore the design flexibility and product customization capabilities of additive manufacturing techniques to process magnetic materials in custom 3D geometries with tailored dielectric properties and frequency response characteristics. Transformation of an RF circuit design idea into a 3D printed system using additive manufacturing techniques will bring together the elements of advanced materials, additive integration, and low-cost manufacturing for future advanced wireless communication systems.

36 MATERIALS SCIENCE↗

S-QGPU: Shared quantum gate processing unit for distributed quantum computing

We propose a distributed quantum computing (DQC) architecture in which individual small-sized quantum computers are connected to a shared quantum gate processing unit (S-QGPU). The S-QGPU comprises a collection of hybrid two-qubit gate modules for remote gate operations. In contrast to conventional DQC systems, where each quantum computer is equipped with dedicated communication qubits, S-QGPU effectively pools the resources (e.g., the communication qubits) together for remote gate operations, and, thus, significantly reduces the cost of not only the local quantum computers but also the overall distributed system. Our preliminary analysis and simulation show that S-QGPU's shared resources for remote gate operations enable efficient resource utilization. When not all computing qubits (also called data qubits) in the system require simultaneous remote gate operations, S-QGPU-based DQC architecture demands fewer communication qubits, further decreasing the overall cost. Alternatively, with the same number of communication qubits, it can support a larger number of simultaneous remote gate operations more efficiently, especially when these operations occur in a burst mode.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Investigating Wireless Quantum Key Distribution for Advanced Reactor Communications

Remote operation of small modular reactor (SMR) facilities is an appealing prospect for streamlined operation costs, safety concerns, and user convenience. The ability to guarantee security of communication channels between offsite users and nuclear reactor facilities is critical to enabling remote operations, given the sensitive nature of reactor state data. This report proposes a configuration implementing quantum key distribution (QKD) and advanced encryption standard (AES) protocols to establish secure reactor data feeds. The model outlined, which utilizes the Argonne-developed SeQUeNCe software package and custom MATLAB code, determines free-space channel losses for microwave-band communications in a variety of weather conditions and simulates QKD via ground-satellite links. This report demonstrates the feasibility of repeatable, real-time key generation and distribution for this configuration towards enabling secure wireless reactor communications.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

ModuleOT

ModuleOT is an open hardware security platform which provides all features necessary for securing remote energy resources. The platform consists of a physical bump in-the wire device which runs a custom-built application built with Go and Python and leverages AES-NI Instruction set available on modern hardware for cryptographic acceleration. By combining these features, ModuleOT acts as an all-in-one low-cost solution to enable cryptographically secured communications to any critical remote servers or devices. Because the software application has been built using Golang, this source can be easily compiled for different hardware platforms. The module is designed to provide the following core features: (1) encrypted communications across an untrusted network, (2) certificate-based authentication with secure storage, (3) hardware cryptographic acceleration, (4) IP-based whitelisting, (5) local firewall management, and (6) legacy (RS485) device support.

Hasandka, Adarsh↗

Autonomous Energy Systems

Energy systems are increasingly complicated by the proliferation of clean energy technologies such as solar, wind, storage, electric vehicles, and building automations. Future energy systems will require secure, autonomous, and reliable communications, control, and interoperability among millions of distributed generation points and billions of buildings, vehicles, and more. To enable effective management of the anticipated growth of distributed devices and the deluge of data and extensive metering that will follow, the National Renewable Energy Laboratory (NREL) has developed the concept of autonomous energy systems (AES).

autonomous↗

Estimating the value of jointly optimized electric power generation and end use: a study of ISO-scale load shaping applied to the residential building stock

A generation-to-load simulation estimated the impact, in terms of production costs and CO2 emissions, attributable to the joint optimization of electric power generation and flexible end uses to support increasing penetrations of renewable energy. Newly conceived, evaluated, and foundational in developing a U.S. National Standard was a transaction-less yet continuous demand response system based on a day-ahead optimum load shape (OLS) designed to encourage Internet-connected devices to autonomously and voluntarily explore options to favour lowest cost generators - without requiring two-way communications, personally identifiable information, or customer opt-in. Boundary conditions used for model calibration included historical weather, residential building stock construction attributes, home appliance and device empirical operating schedules, prototypical power distribution feeder models, thermal generator heat rates, startup and ramping constraints, and fuel costs. Results of an hourly-based annual case study of Texas indicate a 1/3 reduction in production costs and a 1/5 reduction in CO2 emissions are possible.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Quantifying the Financial Impacts of Electric Vehicles on Utility Ratepayers and Shareholders [Slides]

Widespread electric vehicle (EV) adoption is critical for meeting economy-wide decarbonization goals and, as a result, states are considering enabling policies and rate designs to accelerate EV deployment. EVs can provide possible financial upside to electric utilities and ratepayers in several ways. For example, from the utility perspective, EVs could drive increased electricity sales and new earnings opportunities through increased capital investments. From the ratepayer perspective, increased electric loads from EVs could reduce average all-in retail rates. The degree to which there are net benefits or costs to shareholders and/or ratepayers depends on how EVs are integrated and managed through enabling grid investments and charging strategies. Using Berkeley Lab’s Financial Impacts of Distributed Energy Resources (FINDER) model that mimics the electric utility investment planning and ratemaking processes, we estimate the utility earnings and customer rate impacts of EVs using a bookend approach of “managed” (i.e., best case) and “mismanaged” (i.e., worst case) charging strategies for a generic summer-peaking, investor-owned, and vertically integrated utility. The analysis also examines the sensitivity of results to different assumptions of EV deployment characteristics, EV impacts on retail electricity sales, incremental distribution system costs, EV charging location, and utility EV enablement costs (i.e., utility costs to invest in EV charging, controls, and communication to deliver and administer EV programs). The results are intended to inform EV policies and deployment strategies that maximize utility system benefits and minimize ratepayer costs.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Architectural scaling tradeoffs in modular 3D bosonic quantum processors

We propose a modular three-dimensional bosonic quantum processor built from repeatable coupled-cavity modules linked by configurable interconnect networks. Using hardware-motivated graph-theoretic measures, we compare nearest-neighbor, hub-based, and hybrid architectures in terms of interconnect count, communication distance, resource concentration, and implementation complexity. Rather than identifying a universally optimal topology, our analysis shows how these architectures redistribute the costs of scaling, including wiring and port requirements, nonlocal communication distance, exposure to shared resources, routing bottlenecks, and scheduling overhead. Case studies of a \(3\times3\) processor and a larger hierarchical architecture further distinguish finite-size performance from asymptotic scaling. The resulting framework provides a systematic basis for evaluating modular three-dimensional bosonic processors and for identifying the device-level parameters required for quantitative hardware design.

Zhu, Shaojiang [Fermilab] (ORCID:0000000293180092)↗

Communication-Constrained Expansion Planning for Resilient Distribution Systems

Distributed generation and remotely controlled switches have emerged as important technologies to improve the resiliency of distribution grids against extreme weather-related disturbances. Therefore it becomes important to study how best to place them on the grid in order to meet a resiliency criteria, while minimizing costs and capturing their dependencies on the associated communication systems that sustain their distributed operations. This paper introduces the Optimal Resilient Design Problem for Distribution and Communication Systems (ORDPDC) to address this need. The ORDPDC is formulated as a two-stage stochastic mixed-integer program that captures the physical laws of distribution systems, the communication connectivity of the smart grid components, and a set of scenarios that specifies which components are affected by potential disasters. The paper proposes an exact branch-and-price algorithm for the ORDPDC that features a strong lower bound and a variety of acceleration schemes to address degeneracy. The ORDPDC model and branch-and-price algorithm were evaluated on a variety of test cases with varying disaster intensities and network topologies. The results demonstrate the significant impact of the network topologies on the expansion plans and costs, as well as the computational benefits of the proposed approach.

97 MATHEMATICS AND COMPUTING↗

Lessons Learned Using Iridium to Communicate with a CubeSat in Low Earth Orbit

This paper presents the design and approval process for operating an Iridium transceiver on orbit and provide on-orbit performance data obtained from a CubeSat platform in Low Earth Orbit (LEO) (500 km orbit). On-orbit data demonstrates that use of a commercial, low-cost Iridium transceiver can serve as a valuable communication approach for low volume telemetry with less than a 30-minute lag for approximately 90% of the time. In this work, we also demonstrate that a radial differential velocity of 7 km/sec corresponding to about a 37.5kHz doppler shift and a distance of less than 2,000 km can be used for mission planning.

42 ENGINEERING↗