Search NASASearch

SEARCH · Search NASA

Results for “Compact accelerators”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Mechanisms and sites for astrophysical gamma ray line production

The production of gamma ray lines and estimates of line fluxes resulting from nuclear deexcitations, positron annihilation, and electron capture at various astrophysical sites are discussed. Supernova and nova explosions synthesize long-lived radioactive isotopes and eject them into space where they produce observable gamma ray lines by decaying into excited levels of daughter nuclei or by emitting positrons. Energetic charged particles in the interstellar medium, in supernova remants, in solar or stellar flares, and possibly in the vicinity of compact objects, produce gamma-ray lines by inelastic collisions which either excite nuclear levels or produce positrons and neutrons. Energetic particles can result from acceleration in time-varying magnetic fields (solar flares) or from gravitational accretion onto neutron stars and black holes. Electromagnetic processes in the strong magnetic fields of pulsars can produce positron-electron pairs, with line emission resulting from positron annihilation. Deexcitations of quantized states in strong magnetic fields can also produce lines.

Ramaty, R.

Simple, Compact, Safe Impact Tester

An apparatus has been designed and built for testing the effects, on moderate-sized objects, of cushioned decelerations having magnitudes ranging up to several hundred g [where g = normal Earth gravitational acceleration (approximately 9.8 m/s(exp 2))].

Roach, Pat R.

Rugged, low-conductance, heat-flow probe

Lightweight, compact probe structure has low thermal conductance to enable accurate measurement of slight temperature gradients. Probe combines ruggedness, high precision, accuracy, and stability. Device can withstand vibration, shock, acceleration, temperature extremes, and high vacuums, and should interest industrial engineers and geologists.

Boudreau, E. J.

High-velocity winds from a dwarf nova during outburst

An ultraviolet spectrum of the dwarf nova TW Vir during an optical outburst shows shortward-shifted absorption features with edge velocities as high as 4800 km/s, about the escape velocity of a white dwarf. A comparison of this spectrum with the UV spectra of other cataclysmic variables suggests that mass loss is evident only for systems with relatively high luminosities (more than about 10 solar luminosities) and low inclination angles with respect to the observer's line of sight. The mass loss rate for cataclysmic variables is of order 10 to the -11th solar mass per yr; this is from 0.01 to 0.001 of the mass accretion rate onto the compact star in the binary. The mass loss may occur by a mechanism similar to that invoked for early-type stars, i.e., radiation absorbed in the lines accelerates the accreting gas to the high velocities observed.

Cordova, F. A.

Hydrogen Refrigerator Would Cool Below 10 K

Closed-cycle hydrogen refrigerator uses low-level heat energy to cool objects to temperature of 10 K. Refrigerator needs only fraction of energy of previous equipment with similar low-temperature capability. Unit compact and light in weight. With valves as only moving parts, reliable for many years. Refrigeration concept adapted to cooling superconducting magnets on magnetically levitated railcars, nuclear-particle accelerators, and variety of other cryogenic equipment.

Jones, J. A.

High-Energy-Density Capacitors

Capacitors capable of storing energy at high densities are being developed for use in pulse-power circuits in such diverse systems as defibrillators, particle- beam accelerators, microwave sources, and weapons. Like typical previously developed energy-storage capacitors, these capacitors are made from pairs of metal/solid-dielectric laminated sheets that are wound and pressed into compact shapes to fit into cans, which are then filled with dielectric fluids. Indeed, these capacitors can be fabricated largely by conventional fabrication techniques. The main features that distinguish these capacitors from previously developed ones are improvements in (1) the selection of laminate materials, (2) the fabrication of the laminated sheets from these materials, and (3) the selection of dielectric fluids. In simplest terms, a high-performance laminated sheet of the type used in these capacitors is made by casting a dielectric polymer onto a sheet of aluminized kraft paper. The dielectric polymer is a siloxane polymer that has been modified with polar pendant groups to increase its permittivity and dielectric strength. Potentially, this polymer is capable of withstanding an energy density of 7.5 J/cm3, which is four times that of the previous state-of-the-art-capacitor dielectric film material. However, the full potential of this polymer cannot be realized at present because (1) at thicknesses needed for optimum performance (.8.0 m), the mechanical strength of a film of this polymer is insufficient for incorporation into a wound capacitor and (2) at greater thickness, the achievable energy density decreases because of a logarithmic decrease in dielectric strength with increasing thickness. The aluminized kraft paper provides the mechanical strength needed for processing of the laminate and fabrication of the capacitor, and the aluminum film serves as an electrode layer. Because part of the thickness of the dielectric is not occupied by the modified siloxane polymer, the achievable energy density must be somewhat less than the maximum value. The laminate is produced by a continuous film-casting process, using the machinery depicted schematically in the figure. The designs of the process and machinery are dictated partly by the fact that during the processing step prior to casting the polymer, the aluminized kraft paper becomes wet with water. Because the polymer resin to be cast is hydrophobic, the paper must be dried to make it possible to coat the paper uniformly, leaving no pinholes. Accordingly, an infrared heater is placed next to the paper feed roll to dry the paper prior to casting.

Slenes, Kirk

Observational evidence for solar wind acceleration at the base of coronal holes

An EUV spectrometer with a microchannel plate detector was developed to measure Doppler shifts of coronal and transition region lines. The results of three sounding rocket fights of this instrument indicate that EUV resonance emission lines are systematically shifted toward shorter wavelength within coronal holes. This "blue-shift" signature, first identified within compact low latitude holes, was also observed in a well developed polar coronal hole. The maximum measured shift within these coronal holes corresponds to a velocity relative to the remaining solar disc of 12 km/s in lambda 625 Mg X T to the approximately 10 to the 6.15 K power and 7 km /s/ in lambda 629 OV (T to the approximately 10 to the 5.4 K power). The existing data indicate that these blue-shifts are a common (and possibly universal) signature of coronal holes. These data provide important information on the acceleration of coronal plasma in open magnetic field regions, although the interpretation of observed Doppler shifts to derive a systematic mass flux is to some extent model dependent. A straightforward hypothesis is that the blueshift signature is a direct manifestation of the high speed solar wind deep within the transition region and inner corona.

Rottman, G. J.

Analysis of the pre-flight and post-flight calibration procedures performed on the Liulin space radiation dosimeter

Liulin, a dosimetry-radiometry system, was developed to satisfy the requirements for active flux and dose rate measurements for the flight of the second Bulgarian cosmonaut in 1988. The system consists of a compact battery-operated silicon solid state detector unit and a read/write microcomputer and telemetry unit. We describe the pre-flight calibrations with charged particles, using radioactive sources and accelerated 170 MeV/nucleon proton and alpha particles at the Dubna, Russia cyclotron. We discuss comparisons with data obtained on Mir with the French-built tissue equivalent LET spectrometer NAUSICAA. Lastly, we describe post-flight calibrations performed with 1 GeV/nucleon 56Fe ions at the Brookhaven National Laboratory AGS accelerator, where the instrument was mounted in tandem with several thin position-sensitive silicon detectors behind a stopping target. The silicon detectors provided an energy spectrum for the surviving charged nuclear fragments for which the flux and absorbed dose were recorded by Liulin.

long duration

The Nuclear Spectroscopic Telescope Array (NuSTAR)

The Nuclear Spectroscopic Telescope Array (NuSTAR) is a NASA Small Explorer mission that will carry the first focusing hard X-ray (5 - 80 keV) telescope to orbit. NuSTAR will offer a factor 50 - 100 sensitivity improvement compared to previous collimated or coded mask imagers that have operated in this energy band. In addition, NuSTAR provides sub-arcminute imaging with good spectral resolution over a 12-arcminute field of view. After launch, NuSTAR will carry out a two-year primary science mission that focuses on four key programs: studying the evolution of massive black holes through surveys carried out in fields with excellent multiwavelength coverage, understanding the population of compact objects and the nature of the massive black hole in the center of the Milky Way, constraining explosion dynamics and nucleosynthesis in supernovae, and probing the nature of particle acceleration in relativistic jets in active galactic nuclei. A number of additional observations will be included in the primary mission, and a. guest observer program will be proposed for an extended mission to expand the range of scientific targets. The payload consists of two co-aligned depth-graded multilayer coated grazing incidence optics focused onto solid state CdZnTe pixel detectors. To be launched in early 2012 on a Pegasus rocket into a low-inclination Earth orbit. NuSTAR largely avoids SAA passages, and will therefore have low and stable detector backgrounds. The telescope achieves a 10.15-meter focal length through on-orbit deployment of all mast. An aspect and alignment metrology system enable reconstruction of the absolute aspect and variations in the telescope alignment resulting from mast flexure during ground data processing. Data will be publicly available at GSFC's High Energy Astrophysics Science Archive Research Center (HEASARC) following validation at the science operations center located at Caltech.

Harrison, Fiona A.

Detecting Near-Surface Water and Hydrate Minerals on Mars from a Rover, Penetrator, or Borehole: The HYDRA Instrument

One of the major goals of near term NASA Mars exploration is to identify exact locations of near-surface water or hydrated minerals on Mars. Evidence for the existence of recent nearsurface water on Mars underscores the need for developing instrumentation that can identify water or hydrated minerals very near the surface. Further encouraging evidence of surface and near-surface water and hydrate minerals on Mars comes from neutron spectrometer measurements aboard Mars Odyssey. Preliminary results show very large regions of high hydrogen content poleward of 60 deg. latitude, as well as interesting features closer to the equator. However, spatial resolution from orbit is very poor, approx. 400 km. The next logical step is to use in-situ or near-surface investigations to map in detail some of the most interesting features. Relatively simple instrumentation based on He-3 gas proportional counters were shown to be highly successful on the Lunar Prospector mission in identifying even low levels of enhanced hydrogen abundances. Here we discuss HYDRA, a water- and hydrate-sensing instrument currently being developed under the NASA Mars Instrument Development Program (MIDP). HYDRA is based on Lunar Prospector technology, and is intended as a rover body-mounted instrument, or an instrument on an aerobot, penetrator, hard lander on the surface of Mars, or for borehole stratigraphy applications. Our proposed instrument would be ideal for such platforms as it would be small (less than 7 cm diameter by 10 cm long), low mass (less than 500 g), low power (less than 1W), and have a low data volume per measurement. We use neutron spectrometry (a) because of its proven ability to uniquely detect and quantify hydrogen abundance, and (b) because the resources required by this approach (weight, power, size, telemetry bandwidth, and measurement time) are extremely low. This compact neutron spectrometer package, comprised of two small He-3 gas proportional counters, offers superior sensitivity, extensive flight heritage, and inherent ruggedness. These tubes have survived approx. 1500 g's of acceleration in penetrator tests. In a landed application, HYDRA would help address many topics of interest to the Mars Exploration and Astrobiology communities: (a) nature and origin of stratified deposits; (b) water cycle(s) and temporal changes; (c) early water oceans, aquifers, precipitation; (d) current extent/location/state of water; (e) polar cap processes and temporal changes; (f) where extremeophiles could survive on Mars; (g) paleoclimate surface signatures and modeling; (h) strategies for future Mars exploration.

R C Elphic

Miniaturized, High-Speed, Modulated X-Ray Source

A low-cost, miniature x-ray source has been developed that can be modulated in intensity from completely off to full intensity on nanosecond timescales. This modulated x-ray source (MXS) has no filaments and is extremely rugged. The energy level of the MXS is adjustable from 0 to more than 100 keV. It can be used as the core of many new devices, providing the first practical, arbitrarily time-variable source of x-rays. The high-speed switching capability and miniature size make possible many new technologies including x-ray-based communication, compact time-resolved x-ray diffraction, novel x-ray fluorescence instruments, and low- and precise-dose medical x-rays. To make x-rays, the usual method is to accelerate electrons into a target material held at a high potential. When the electrons stop in the target, x-rays are produced with a spectrum that is a function of the target material and the energy to which the electrons are accelerated. Most commonly, the electrons come from a hot filament. In the MXS, the electrons start off as optically driven photoelectrons. The modulation of the x-rays is then tied to the modulation of the light that drives the photoelectron source. Much of the recent development has consisted of creating a photoelectrically-driven electron source that is robust, low in cost, and offers high intensity. For robustness, metal photocathodes were adopted, including aluminum and magnesium. Ultraviolet light from 255- to 350-nm LEDs (light emitting diodes) stimulated the photoemissions from these photocathodes with an efficiency that is maximized at the low-wavelength end (255 nm) to a value of roughly 10(exp -4). The MXS units now have much higher brightness, are much smaller, and are made using a number of commercially available components, making them extremely inexpensive. In the latest MXS design, UV efficiency is addressed by using a high-gain electron multiplier. The photocathode is vapor-deposited onto the input cone of a Burle Magnum(TradeMark) multiplier. This system yields an extremely robust photon-driven electron source that can tolerate long, weeks or more, exposure to air with negligible degradation. The package is also small. When combined with the electron target, necessary vacuum fittings, and supporting components (but not including LED electronics or high-voltage sources), the entire modulated x-ray source weighs as little as 158 grams.

Gendreau, Keith

PT-1 Plasmoid Thruster Capable of Multi-Mode Operation

This slide presentation reviews the concept of a Plasmoid Thruster that is capable of operating in several different modes. A plasmoid is a compact plasma structure with an integral magnetic field, that may be categorized according to the relative strength of the poloidal and toroidal magnetic fields. A plasmoid thruster would operate by repetitively producing plasmoids that are accelerated to high velocity. The process is inductive, and the magnetic structure of the plasmoid suppresses thermal and mass losses, and improves detachment of the exhaust. The Drive and Bias circuits, the gas distribution, the pre-ionization stage, and the operation sequence are detailed. The advantages of the Plasmoid thruster and the research and technology required for development of this form of propulsion is reviewed.

Miller, Robert

Application of the Bernoulli enthalpy concept to the study of vortex noise and jet impingement noise

A complete theory of aeroacoustics of homentropic fluid media is developed and compared with previous theories. The theory is applied to study the interaction of sound with vortex flows, for the DC-9 in a standard take-off configuration. The maximum engine-wake interference noise is estimated to be 3 or 4 db in the ground plane. It is shown that the noise produced by a corotating vortex pair departs significantly from the compact M scaling law for eddy Mach numbers (M) greater than 0.1. An estimate of jet impingement noise is given that is in qualitative agreement with experimental results. The increased noise results primarily from the nonuniform acceleration of turbulent eddies through the stagnation point flow. It is shown that the corotating vortex pair can be excited or de-excited by an externally applied sound field. The model is used to qualitatively explain experimental results on excited jets.

Yates, J. E.

Magnetic field-aligned electric potentials in nonideal plasma flows

The electric field component parallel to the magnetic field arising from plasma flows which violate the frozen-in field condition of ideal magnetohydrodynamics is discussed. The quantity of interest is the potential U = integral E parallel ds where the integral is extended along field lines. It is shown that U can be directly related to magnetic field properties, expressed by Euler potentials, even when time-dependence is included. These results are applicable to earth's magnetosphere, to solar flares, to aligned-rotator models of compact objects, and to galactic rotation. On the basis of order-of-magnitude estimates, these results support the view that parallel electric fields associated with nonideal plasma flows might play an important role in cosmic particle acceleration.

Schindler, K.

Compact electron-beam source for formation of neutral beams of very low vapor pressure materials

In order to form metal vapors for neutral beam studies, an electron-beam heater and a power supply have been designed. The source, which measures about 30 x 50 x 70 mm, consists of a filament, accelerating plate (defined by pole pieces), and a supported target. The electrons from the filament are focused by the field penetration through a 2 mm slit in the high-voltage cage. They are then accelerated to about 5 kV to a ground plate. The electrons then follow a path in the magnetic field and strike the sample to be heated on its front surface. The assembly is attached to a water-cooled base plate. The electron beam source has produced beams of Ta and C particles with densities of about 10 to the 8th power/cu cm.

Rutherford, J. A.

VLA observations of positions 42 6 centimeter burst peaks associated with hard X-ray burst spikes

Using the Very Large Array with a spatial resolution of 3 arcsec, two-dimensional, 10-second synthesis maps are produced of four 6-cm lambda bursts associated with multiply spiked hard X-ray bursts (20-300 keV). The positional, structural, and polarization characteristics are investigated. It is noted that three of the four burst sources are rather compact (less than approximately 10 arcsec). It is found that the positions of the individual peaks or spikes within a single burst are the same within plus or minus 2 arcsec. Interpreting these different peaks as separate electron acceleration events, the results suggest repeated acceleration of electrons within the same magnetic trap. The trap situation is found to be consistent with the bipolar nature of the burst sources except in one case.

Kundu, M. R.

Active extragalactic sources - Nearly simultaneous observations from 20 centimeters to 1400 A

IRAS, IUE, and ground-based optical, NIR, mm and submm, and radio observations obtained mainly on Apr. 9-23, 1983, are reported for 19 active extragalactic sources and eight control sources. The overall spectra of the compact active sources are shown to be well represented by continuous-curvature functions such as parabolas. The spectra are found to be consistent with models involving continuous particle injection (with synchrotron losses) or first-order Fermi acceleration (with escape and synchrotron losses), but not with models using relativistic Maxwellian electron distributions.

Landau, R.

Compact jets and the AGN paradigm

The nature of compact, nonthermal jets in active galactic nuclei is reviewed from both observational and theoretical standpoints. Despite rapid variations in brightness, the smallest emission regions in a jet may be relatively far removed from the central engine. Certain models for the formation of a relativistic particle beam that evolves downstream into the observed radio-infrared jet do, however, predict substantial high energy radiation from regions in the beam close to the accretion disk. Observations of such emission, and the general requirement that the jets be well collimated and accelerated to relativistic bulk velocities by the point where they are observed in the radio, can provide indirect constraints on the massive black hole accretion paradigm. Observations of well collimated, semi-relativistic jets in the accreting stellar systems SS 433 and Cyg X-3, as well as slower jets emanating from star forming regions, encourage one to associate jet formation with accretion of gas onto a compact object.

Marscher, Alan P.