Search NASA⌕ Search

SEARCH · Search NASA

Results for “Comparative Analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Comparing Analysis of Hydrogen Concentration in Astromaterials Nominally Anhydrous Minerals by Multiple SIMS

Secondary Ion Mass Spectrometry (SIMS) is utilized to determine hydrogen (H) concentration in astromaterials nominally anhydrous minerals (NAMs) and their inclusions [e.g., 1]. This data is interpreted to refine the volatile history of planetary bodies. Four instruments are being used to compare H concentration analysis: a large geometry SIMS (The University of Hawaiʻi Cameca IMS 1280), a compact SIMS (Arizona State University (ASU) Cameca IMS 6f), and two Cameca NanoSIMS 50L at ASU and NASA-Johnson Space Center (JSC). Results on the first three instruments are available. Although fundamentally similar, SIMS instruments and their modifications [2] may produce different values or pose advantages for H analysis, especially for shocked samples that are susceptible to contamination filling their fractures. New data from the IMS 1280 is reported, using its microchannel plate (MCP) to image high H signals in grain fractures during pre-sputtering to avoid them as much as possible. Between fractures, 16 OH/ 30 Si was measured with a Cs + 4 nA primary beam, 30 micron spot size, and central ~5x5 micron collection area. First order comparison of H concentration (reported in ppm H 2 O) is achieved on a terrestrial gem quality clinopyroxene (SLP114, 162±12 ppm H 2 O [3]), with 157±7 and 215±40 ppm H 2 O by the IMS 1280 and 6f respectively. SIMS comparison is then extended to analysis of two Martian shergottites: RBT 04262 and NWA 5789. Due to a dense fracture network (< 20 micron) in RBT 04262, only one clinopyroxene hosted glassy inclusion was analyzed (n=6, ≤1 ppm H 2 O), while six olivine grains in NWA 5789 (n=12, ≤ 2 ppm H 2 O) (1s ±0.21) were analyzed. Higher concentrations were obtained for RBT 04262 olivine by the ASU NanoSIMS 50L (up to 350 ppm H 2 O [4]), and IMS 6f (300+ ppm H 2 O, [5]), for which contamination in fractures could not be avoided. Work on the JSC NanoSIMS 50L will further develop the SIMS comparison.

J.-M. Dudley↗

A Unified Scaling Framework for Comparative Analysis of Major Electrical Machine Topologies

This paper presents a unified framework for comparing major electrical machine topologies under identical output and thermal constraints, with emphasis on supply-chain-aware selection among rare-earth-intensive, reduced-rare-earth, and rare-earth-free solutions. Using power factor and air-gap flux density as the principal descriptors, the framework links topology choice to relative size, copper demand, magnet dependence, cost sensitivity, and inertia. To support robust early-stage screening, the deterministic scaling model is combined with uncertainty representation, Monte Carlo scenario propagation, and hesitationaware ranking. The results show that rare-earth-rich machines remain compact and dense, whereas reduced-rare-earth and rare-earth-free alternatives become more attractive under specific material-risk and cost scenarios.

Kumar, Praveen [ORNL] (ORCID:0000000291877857)↗

A comparative analysis of green building rating systems in China and the United States

Several studies have compared green building rating systems (GBRSs) in China and the United States, Nonetheless, few studies included in-depth analysis on specific rating tools with project specific data validating green building technologies and actual performance. This study conducted a comprehensive data-driven comparison of the GBRSs of China and the United States. The goal was to understand the current status and further improve China's GBRS and promote green building technologies. The study first conducted thorough comparisons of GBRSs in China and the U.S. by selecting a series of distinct rating tools. Then, it analyzed each tool's development objectives, contents, and rating score settings. Further, the comparison concludes the future development needs for China's GBRS. In addition to standard comparison, green building technologies applied in certified projects were also summarized. The results demonstrated that GBRSs in both China and the U.S. reflect well the technical paths to achieve green building sustainable development. By analyzing certified projects, it was also found that the incremental costs of green building technologies were controllable. Finally, based on the comparison and case analysis, the study provide a set of policy recommendations to further improve China's green building standards.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Computational studies of structural, energetic, and electronic properties of pure Pt and Mo and mixed Pt/Mo clusters: Comparative analysis of characteristics and trends

The added technological potential of bimetallic clusters and nanoparticles, as compared to their pure (i.e., one-component) counterparts, stems from the ability to further fine-tune their properties and, consequently, functionalities through a simultaneous use of the “knobs” of size and composition. The practical realization of this potential can be greatly advanced by the knowledge of the correlations and relationships between the various characteristics of bimetallic nanosystems on the one hand and those of their pure counterparts as well as pure constituent components on the other hand. Here, in this study, we present results of a density functional theory based study of pure Pt n and Mo n clusters aimed at revisiting and exploring further their structural, electronic, and energetic properties. These are then used as a basis for analysis and characterization of the results of calculations on two-component Pt n-m Mo m clusters. The analysis also includes establishing relationships between the properties of the Pt n-m Mo m clusters and those of their Pt n-m and Mo m components. One of the particularly intriguing findings suggested by the calculated data is a linear dependence of the average binding energy per atom in sets of Pt n-m Mo m clusters that have the same fixed number m of Mo atoms and different number n-m of Pt atoms on the fractional content (n-m)/n of Pt atoms. We derive an analytical model that establishes the fundamental basis for this linearity and expresses its parameters—the m-dependent slope and intercept—in terms of characteristic properties of the constituent components, such as the average binding energy per atom of Mo m and the average per-atom adsorption energy of the Pt atoms on Mo m . The conditions of validity and degree of robustness of this model and of the linear relationship predicted by it are discussed.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Comparative analysis of condensation models within DSMC

Two condensation process modeling approaches within DSMC methodology are compared. The first is based on the modified nucleation theory which correctly describes small clusters and the second on the kinetic theory and considers not only supercritical clusters, but clusters of all sizes including dimers. The relaxation of the size distribution function is calculated for the spatially homogeneous cases, where the monomer parameters are kept constant. As an example the vapour of Cu atoms is considered and importance of taking into account of the internal energies of clusters is shown. Peculiarities of the classical and kinetic approaches are discussed herein.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Ring Current Dynamics in Moderate and Strong Storms: Comparative Analysis of TWINS and IMAGE/HENA Data with the Comprehensive Ring Current Model

We present a comparative study of ring current dynamics during strong and moderate storms. The ring current during the strong storm is studied with IMAGE/HENA data near the solar cycle maximum in 2000. The ring current during the moderate storm is studied using energetic neutral atom (ENA) data from the Two Wide-Angle Imaging Neutral- Atom Spectrometers (TWINS) mission during the solar minimum in 2008. For both storms, the local time distributions of ENA emissions show signatures of postmidnight enhancement (PME) during the main phases. To model the ring current and ENA emissions, we use the Comprehensive Ring Current Model (CRCM). CRCM results show that the main-phase ring current pressure peaks in the premidnight-dusk sector, while the most intense CRCM-simulated ENA emissions show PME signatures. We analyze two factors to explain this difference: the dependence of charge-exchange cross section on energy and pitch angle distributions of ring current. We find that the IMF By effect (twisting of the convection pattern due to By) is not needed to form the PME. Additionally, the PME is more pronounced for the strong storm, although relative shielding and hence electric field skewing is well developed for both events.

Buzulukova, N.↗

Comparative Analysis of the Luminescence of Ge:Sb Layers Grown on Ge(001) and Si(001) Substrates

Comparative studies of the luminescence properties of Sb-doped Ge layers grown on Ge(001) and Si(001) substrates are carried out. It is shown that, in contrast to the case of Ge:Sb layers grown on Si, a considerable contribution to the photoluminescence signal from Ge:Sb/Ge(001) layers is made by indirect optical transitions. This fact is attributed to the longer charge-carrier lifetime in Ge:Sb/Ge homoepitaxial structures because of the lack of crystal-lattice defects related to the relaxation of elastic strains in such structures. It is shown that the experimentally observed significant increase in the contribution of direct optical transitions to the total photoluminescence signal with increasing doping level of Ge:Sb/Ge(001) layers results from an increase in the population of electron states in the Γ valley. At Sb concentrations much higher than the equilibrium solubility of Sb in Ge, partial electrical activation of the impurity is observed, and in this case, a profound effect on the emission properties of Ge:Sb layers grown on different substrates is produced by nonradiative-recombination centers, whose role can be played by clusters of impurity atoms.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Comparative Analysis of Alternative Spectral Bands of CO2 and O2 for the Sensing of CO2 Mixing Ratios

We performed comparative studies to establish favorable spectral regions and measurement wavelength combinations in alternative bands of CO2 and O2, for the sensing of CO2 mixing ratios (XCO2) in missions such as ASCENDS. The analysis employed several simulation approaches including separate layers calculations based on pre-analyzed atmospheric data from the modern-era retrospective analysis for research and applications (MERRA), and the line-byline radiative transfer model (LBLRTM) to obtain achievable accuracy estimates as a function of altitude and for the total path over an annual span of variations in atmospheric parameters. Separate layer error estimates also allowed investigation of the uncertainties in the weighting functions at varying altitudes and atmospheric conditions. The parameters influencing the measurement accuracy were analyzed independently and included temperature sensitivity, water vapor interferences, selection of favorable weighting functions, excitations wavelength stabilities and other factors. The results were used to identify favorable spectral regions and combinations of on / off line wavelengths leading to reductions in interferences and the improved total accuracy.

Pliutau, Denis↗

Comparative Analysis of Pendulum and Flywheel Power Take-Off Mechanisms for Wave Energy Conversion

Here, this study compares three power-take-off (PTO) mechanisms for wave energy converters—a flywheel -type pitch resonator and two pendulum variants (normal and inverted)—all designed to fit within a fixed envelope. Performance is assessed via linear frequency-domain models and bi-conjugate impedance matching under a representative sea state. The inverted-pendulum PTO achieves 27.9% of the incident wave energy, versus 16.5% for the normal pendulum and 4.2% for the flywheel—that is, 6.6 × and 3.9 × improvements, respectively. These gains arise because pendulum-based systems generate higher torque for a given buoy motion and maintain impedance matching across a wider frequency band. Parametric studies of mass, pendulum arm length, spring stiffness, generator friction, and motor constant quantify the impact of key design choices on power output. By locating the pendulum pivot near the buoy's center of gravity and positioning the center of rotation below the COG, surge–pitch coupling is improved and energy transfer is further boosted.

Keow, Alicia Li Jen [Sandia National Laboratories ↗

SU-F-I-02: Comparative Analysis and Constancy Check of Image Quality Parameters for Three Linear Accelerators Per TG 142 Protocol

Purpose: To compare image quality parameters and assessing the image stability of three different linear accelerators (linac) for 2D and 3D imaging modalities: planar kV, MV images and cone-beam CT (CBCT). Methods: QCkV1, QC-3 and Cathpan-600 phantoms were utilized to acquire kV, MV and CBCT images respectively on monthly basis per TG142 QA protocol for over 2 years on 21Ex, NovalisTx and TrueBeam linacs. DICOM images were analyzed with the help of QA analysis software: PIPsPro from Standard Imaging. For planar kV and MV images, planar spatial resolution, contrast to noise ratio (CNR) and noise; for CBCT, HU values were collected and analyzed. Results: Two years of monthly QA measurements were analyzed for the planar and CBCT images. Values were normalized to the mean and the standard deviations (STD) are presented. For the kV planar radiographic images the STD of spatial resolution for f30, f40, f50, CNR and noise for 21Ex are 0.006, 0.011, 0.013, 0.046, 0.026; Novalis-Tx are 0.009, 0.016, 0.016, 0.067, 0.053 ; TrueBeam are 0.007, 0.005, 0.009, 0.017, 0.016 respectively. For the MV planar radiographic images, the STD of spatial resolution for f30, f40, f50, CNR and noise for 21Ex are 0.009, 0.010, 0.008, 0.023, 0.023; for Novalix-Tx are 0.012, 0.010, 0.008, 0.029, 0.023 and for TrueBeam are 0.010, 0.010, 0.007, 0.022, 0.022 respectively. For the CBCT images, HU constancies of Air, Polystyrene, Teflon, PMP, LDPE and Delrin for 21Ex are 0.014, 0.070, 0.031, 0.053, 0.076, 0.087; for Novalis Tx are 0.019, 0.047, 0.035, 0.059, 0.077, 0.087 and for TrueBeam are 0.011, 0.044, 0.025, 0.044, 0.056, 0.020 respectively. Conclusion: These Imaging QA results demonstrated that the TrueBeam, performed better in terms of image quality stability for both kV planer and CBCT images as well as EPID MV images, however other two linacs were also satisfied TG142 guidelines.

60 APPLIED LIFE SCIENCES↗

PathTrace and MPVEASI: A Path Analysis Comparative Validation Study

Developed in 2018, PathTrace is a software package built with the intention of making path analysis simple and intuitive. PathTrace is a top-down pathway analysis software where a user is able to explore vulnerable pathways into a facility. The intention of utilizing a software tool like PathTrace is to characterize an existing physical protection system (PPS) and to upgrade the system to achieve a high level of response interruption, or probability of interruption (P I ) of the adversary. There are four steps for conducting path analysis using PathTrace. The first step is to identify an image to use to build the model and scale the model within PathTrace using a section of known distance (wall or fence perimeter, for example). The scaling process will produce a grid of cells through which the user is able to build a model. The second step is to fill out the grid of cells with four categories of materials: Barriers, Detection Areas, Jumps, and Targets. These materials apply associated delay and detection values to the cells in which they are applied. The third step is to represent the adversary and response forces. The adversaries are represented by their capabilities in interacting with the materials identified in step two, and the response is represented by how quickly they will be able to respond to an adversary attack. Finally, the user is able to take all of the information from the previous three steps and perform a Most Vulnerable Path (MVP) analysis. In this stage, the user is able to visualize vulnerable adversary pathways and reason about how to upgrade these pathways to provide a high level of P I .

97 MATHEMATICS AND COMPUTING↗

Comparative Analysis of Intra-arterial Cone-Beam Versus Conventional Computed Tomography During Hepatic Arteriography for Transarterial Chemoembolization Planning

Purpose: To compare the imaging characteristics of intra-arterial cone-beam computed tomography during hepatic arteriography (CBCTHA) versus intra-arterial computed tomography during hepatic arteriography (CTHA) for intraprocedural transarterial chemoembolization (TACE) planning. Materials and Methods: This single-institution retrospective study included 144 patients (96 men, mean age 67.9 years; 48 women, mean age 62.3 years) who underwent 181 TACE sessions between January 2015 and July 2017. Intraprocedural CBCTHA (111 procedures) or CTHA (70 procedures) was performed for TACE planning. Reformatted maximum intensity projection CBCTHA and CTHA images were reviewed by two radiologists and classified using an ordinal scoring system (for tumor identification, tumor feeder vessel identification, and streaking artifact) and a binary scoring system (for the presence of breathing motion artifact and field of view encompassing the entire liver). Data were analyzed using an F test and a z-score test. Results: There were no significant differences in demographic and tumor characteristics between the CBCTHA and CTHA patient cohorts. CTHA was superior to CBCTHA for tumor identification (P < .0001), tumor feeder vessel identification (P < .05), streaking artifact (P < .0001), and field of view encompassing the entire liver (P < .0001). There was a trend toward a lower frequency of breathing motion artifact with CTHA than with CBCTHA (1.4% vs. 10%; P = .057). Conclusion: CTHA provides improved clinical relevant imaging information compared to CBCTHA for intraprocedural TACE planning. Level of Evidence: Level III, retrospective comparative study.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Comparative analysis of magnetic resonance in the polaron pair recombination and the triplet exciton-polaron quenching models

We present a comparative theoretical study of magnetic resonance within the polaron pair recombination (PPR) and the triplet exciton-polaron quenching (TPQ) models. Both models have been invoked to interpret the photoluminescence detected magnetic resonance (PLDMR) results in π-conjugated materials and devices. We show that resonance line shapes calculated within the two models differ dramatically in several regards. First, in the PPR model, the line shape exhibits unusual behavior upon increasing the microwave power: it evolves from fully positive at weak power to fully negative at strong power. In contrast, in the TPQ model, the PLDMR is completely positive, showing a monotonic saturation. Second, the two models predict different dependencies of the resonance signal on the photoexcitation power, P L . At low P L , the resonance amplitude Δ I/I is ∝ P L within the PPR model, while it is ∝ P 2 L crossing over to P 3 L within the TPQ model. On the physical level, the differences stem from different underlying spin dynamics. Most prominently, a negative resonance within the PPR model has its origin in the microwave-induced spin-Dicke effect, leading to the resonant quenching of photoluminescence. The spin-Dicke effect results from the spin-selective recombination, leading to a highly correlated precession of the on-resonance pair partners under the strong microwave power. This effect is not relevant for TPQ mechanism, where the strong zero-field splitting renders the majority of triplets off resonance. On the technical level, the analytical evaluation of the line shapes for the two models is enabled by the fact that these shapes can be expressed via the eigenvalues of a complex Hamiltonian. This bypasses the necessity of solving the much larger complex linear system of the stochastic Liouville equations. Lastly, our findings pave the way towards a reliable discrimination between the two mechanisms via cw PLDMR.

36 MATERIALS SCIENCE↗

SU-F-T-622: Comparative Analysis of Pencil Beam and Anisotropic Analytical Algorithm (AAA) for Stereotactic Body Radiation Therapy (SBRT) of Thoracic Spine

Purpose: To compare the impact of Pencil Beam(PB) and Anisotropic Analytic Algorithm(AAA) dose calculation algorithms on OARs and planning target volume (PTV) in thoracic spine stereotactic body radiation therapy (SBRT). Methods: Ten Spine SBRT patients were planned on Brainlab iPlan system using hybrid plan consisting of 1–2 non-coplanar conformal-dynamic arcs and few IMRT beams treated on NovalisTx with 6MV photon. Dose prescription varied from 20Gy to 30Gy in 5 fractions depending on the situation of the patient. PB plans were retrospectively recalculated using the Varian Eclipse with AAA algorithm using same MUs, MLC pattern and grid size(3mm).Differences in dose volume parameters for PTV, spinal cord, lung, and esophagus were analyzed and compared for PB and AAA algorithms. OAR constrains were followed per RTOG-0631. Results: Since patients were treated using PB calculation, we compared all the AAA DVH values with respect to PB plan values as standard, although AAA predicts the dose more accurately than PB. PTV(min), PTV(Max), PTV(mean), PTV(D99%), PTV(D90%) were overestimated with AAA calculation on average by 3.5%, 1.84%, 0.95%, 3.98% and 1.55% respectively as compared to PB. All lung DVH parameters were underestimated with AAA algorithm mean deviation of lung V20, V10, V5, and 1000cc were 42.81%,19.83%, 18.79%, and 18.35% respectively. AAA overestimated Cord(0.35cc) by mean of 17.3%; cord (0.03cc) by 12.19% and cord(max) by 10.5% as compared to PB. Esophagus max dose were overestimated by 4.4% and 5cc by 3.26% for AAA algorithm as compared to PB. Conclusion: AAA overestimated the PTV dose values by up to 4%.The lung DVH had the greatest underestimation of dose by AAA versus PB. Spinal cord dose was overestimated by AAA versus PB. Given the critical importance of accuracy of OAR and PTV dose calculation for SBRT spine, more accurate algorithms and validation of calculated doses in phantom models are indicated.

60 APPLIED LIFE SCIENCES↗

Comparative Analysis of Rear Irradiance Modeling Methods for Bifacial PV Systems on Single-Axis Trackers Under Varying Albedo Conditions

This study compares three rear-side irradiance modeling methods for bifacial PV systems on single-axis trackers: (i) the 2D View Factor (VF) model in PVsyst(R), (ii) the open-source PVFactors VF model, and (iii) the Ray Tracing (RT) technique using bifacial_radiance. Simulations were benchmarked against field measurements from a pilot PV plant with rear-side sensors at the torque tube height. Results show that all models underestimated the non-uniformity of rear irradiance along the module length and overestimated the total rear irradiance incident on the module. However, since bifacial gain represents only a fraction of the system's total energy, the resulting energy yield differences among methods remained within +- 2 % of measured values, which is typical for such simulations. While the overall energy impact is limited, this study characterizes the specific limitations of each modeling approach, supporting further improvements in bifacial PV performance assessment methods.

14 SOLAR ENERGY↗