Search NASA⌕ Search

SEARCH · Search NASA

Results for “Concentration of measure”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Laser Rayleigh and Raman Diagnostics for Small Hydrogen/oxygen Rockets

Localized velocity, temperature, and species concentration measurements in rocket flow fields are needed to evaluate predictive computational fluid dynamics (CFD) codes and identify causes of poor rocket performance. Velocity, temperature, and total number density information have been successfully extracted from spectrally resolved Rayleigh scattering in the plume of small hydrogen/oxygen rockets. Light from a narrow band laser is scattered from the moving molecules with a Doppler shifted frequency. Two components of the velocity can be extracted by observing the scattered light from two directions. Thermal broadening of the scattered light provides a measure of the temperature, while the integrated scattering intensity is proportional to the number density. Spontaneous Raman scattering has been used to measure temperature and species concentration in similar plumes. Light from a dye laser is scattered by molecules in the rocket plume. Raman spectra scattered from major species are resolved by observing the inelastically scattered light with linear array mounted to a spectrometer. Temperature and oxygen concentrations have been extracted by fitting a model function to the measured Raman spectrum. Results of measurements on small rockets mounted inside a high altitude chamber using both diagnostic techniques are reported.

Degroot, Wilhelmus A.↗

Effect of reactor loading on atomic oxygen concentration as measured by NO chemiluminescence

It has previously been observed that the etch rate of polyethylene samples in the afterglow of an RF discharge in oxygen increases with reactor loading. This enhancement of the etch rate is attributed to reactive gas phase products of the polymer etching. In the present work, emission spectroscopy is employed to examine the species present in the gas phase during etching of polyethylene. In particular, the concentration of atomic oxygen downstream from the polyethylene samples is studied as a function of the reactor loading. It is found that the concentration of atomic oxygen increases as the reactor loading is increased. The increase of etch rate with increased reactor loading is attributed to the increase of atomic oxygen concentration in the vicinity of the sample.

Lerner, N. R.↗

Three Methods of Detection of Hydrazines

Three proposed methods for measuring trace quantities of hydrazines involve ionization and detection of hydrazine derivatives. These methods are intended to overcome the limitations of prior hydrazine- detection methods. Hydrazine (Hz), monomethylhydrazine (MMH), and unsymmetrical dimethylhydrazine (UDMH) are hypergolic fuels and are highly reactive, toxic, and corrosive. A capability to measure concentrations of hydrazines is desirable for detecting leaks and ensuring safety in aerospace settings and in some industrial settings in which these compounds are used. One of the properties (high reactivity) that make it desirable to detect trace amounts of hydrazines also makes it difficult to detect hydrazines and measure their concentrations accurately using prior methods: significant amounts are lost to thermal and catalytic decomposition prior to detection. Further complications arise from the sticky nature of hydrazines: Sample hydrazine molecules tend to become irreversibly adsorbed onto solid surfaces with which they come into contact during transport to detectors, giving rise to drift in detector responses. In each proposed method, the reactive, sticky nature of hydrazines would be turned to advantage by providing a suitably doped substrate surface with which the hydrazines would react. The resulting hydrazine derivatives would be sufficiently less sticky and sufficiently more stable so that fewer molecules would be lost to decomposition or adsorption during transport. Consequently, it would be possible to measure concentration with more sensitivity and less error than in prior techniques. The first proposed method calls for the use of a recently developed technique known as desorption electrospray ionization (DESI), in which a pneumatically assisted micro -electrospray at ambient pressure is directed at a surface of interest. In this case, the surface of interest would be that of a substrate described above.

Griffin, Timothy↗

Measuring metallic concentrations in glycol solutions

A study of atomic absorption spectroscopy as a possible nonobtrusive corrosion indicator for solar-energy systems is described. Procedures were tested for determining low levels of metallic concentration in aqueous glycol formulations. Other methods for determining corrosion are suggested.

Source record↗

The preservation of urine samples for determination of renal stone risk factors

A preservation technique for urine specimens before determination of stone risk factors was evaluated. The purpose of these experiments was to prove the effectiveness of the preservatives used to prevent changes in the concentrations of those constituents measured. Measured concentrations in fresh specimens were compared with those in the same specimens after storage with the preservatives. Refrigeration at 4 degrees C up to five days was appropriate in a laboratory setting, as no significant changes in urinary concentrations occurred. Refrigeration, however, did not offer a convenient method for shipping. Chemical preservation was found to be an effective alternative to refrigeration. Thymol prevented changes in concentration of pH, citrate, uric acid, sulfate, sodium, potassium, and cyclic AMP, while a mixture of hydrochloric (HCl) acid and boric acid prevented changes in calcium, magnesium, phosphorus, oxalate, ammonium, and creatinine. Thus, the addition of thymol or HCl/boric acid to urine specimens will prevent significant changes in the concentrations of stone risk factors.

Non-NASA Center↗

In-Flight Water Quality Monitoring on the International Space Station (ISS): Measuring Biocide Concentrations with Colorimetric Solid Phase Extraction (CSPE)

The colorimetric water quality monitoring kit (CWQMK) was delivered to the International Space Station (ISS) on STS-128/17A and was initially deployed in September 2009. The kit was flown as a station development test objective (SDTO) experiment to evaluate the acceptability of colorimetric solid phase extraction (CSPE) technology for routine water quality monitoring on the ISS. During the SDTO experiment, water samples from the U.S. water processor assembly (WPA), the U.S. potable water dispenser (PWD), and the Russian system for dispensing ground-supplied water (SVO-ZV) were collected and analyzed with the CWQMK. Samples from the U.S. segment of the ISS were analyzed for molecular iodine, which is the biocide added to water in the WPA. Samples from the SVOZV system were analyzed for ionic silver, the biocide used on the Russian segment of the ISS. In all, thirteen in-flight analysis sessions were completed as part of the SDTO experiment. This paper provides an overview of the experiment and reports the results obtained with the CWQMK. The forward plan for certifying the CWQMK as operational hardware and expanding the capabilities of the kit are also discussed.

Gazda, Daniel B.↗

Ion and laser microprobes applied to the measurement of corrosion produced hydrogen on a microscopic scale.

Use of an ion microprobe and a laser microprobe to measure concentrations of corrosion-produced hydrogen on a microscopic scale. Hydrogen concentrations of several thousand ppm were measured by both analytical techniques below corroded and fracture surfaces of hot salt stress corroded titanium alloy specimens. This extremely high concentration compares with only about 100 ppm hydrogen determined by standard vacuum fusion chemical analyses of bulk samples. Both the ion and laser microprobes were used to measure hydrogen concentration profiles in stepped intervals to substantial depths below the original corroded and fracture surfaces. For the ion microprobe, the area of local analysis was 22 microns in diameter and for the laser microprobe, the area of local analysis was about 300 microns in diameter. The segregation of hydrogen below fracture surfaces supports a previously proposed theory that corrosion-produced hydrogen is responsible for hot salt stress corrosion embrittlement and cracking of titanium alloys. These advanced analytical techniques suggest great potential for many areas of stress corrosion and hydrogen embrittlement research, quality control, and field inspection of corrosion problems. For example, it appears possible that a contour map of hydrogen distribution at notch roots and crack tips could be quantitatively determined. Such information would be useful in substantiating current theories of stress corrosion and hydrogen embrittlement.

Gray, H. R.↗

Simultaneous in situ measurements and diurnal variations of NO, NO2, O3, jNO2, CH4, H2O, and CO2 in the 40- to 26-km region using an open path tunable diode laser spectrometer

Simultaneous in situ measurements of temperature, pressure, and the NO, NO2, O3, jNO2, CH4, H2O, and CO2 concentrations were conducted in the 40- to 26-km region of the stratosphere using the JPL Balloon-borne Laser In Situ Sensor, a tunable diode laser absorption spectrometer. The NO, NO2, CH4, H2O, and CO2 concentration measurements generally show good agreement with previous observations, with a tendency for somewhat lower NO2 amounts. Measured O3 concentrations at 38 km agree well with comparable measurements from in situ UV photometers, but at 28 km they are lower by about 10 percent and agree more closely with the solar backscattered UV data. A decline was found in NO2 during the night over a 5-km altitude range, which implies either lower NO2 postsunset profiles, or an NO2 decay rate that is significantly higher than current model predictions that use N2O5 chemistry.

Webster, Christopher R.↗

Atmospheric distribution of Kr-85 simulated with a general circulation model

A three-dimensional chemical tracer model for the troposphere is used to simulate the global distribution of Kr-85, a long-lived radioisotope released at northern midlatitudes by nuclear industry. Simulated distributions for the period 1980-1983 are in excellent agreement with data from six latitudinal profiles measured over the Atlantic. High concentrations of Kr-85 are predicted over the Arctic in winter, advected from European sources, and somewhat smaller enhancements arising from the same sources are predicted over the tropical Atlantic in summer. Latitudinal gradients are steepest in the northern tropics, with distinctly different seasonal variations over the Pacific, as compared to the Atlantic. The global inventory of Kr-85 is reconstructed for the period 1980-1983 by combining the concentrations measured over the Atlantic with the global distributions predicted by the model. The magnitude of the Soviet source is derived. The interhemispheric exchange time is calculated as 1.1 years, with little seasonal dependence.

Jacob, Daniel J.↗

High Energy 2-Micron Solid-State Laser Transmitter for NASA's Airborne CO2 Measurements

A 2-micron pulsed, Integrated Path Differential Absorption (IPDA) lidar instrument for ground and airborne atmospheric CO2 concentration measurements via direct detection method is being developed at NASA Langley Research Center. This instrument will provide an alternate approach to measure atmospheric CO2 concentrations with significant advantages. A high energy pulsed approach provides high-precision measurement capability by having high signal-to-noise level and unambiguously eliminates the contamination from aerosols and clouds that can bias the IPDA measurement.

Singh, Upendra N.↗

System for measuring roundness and concentricity of large tanks

Equipment measures the roundness and concentricity of large, massive tanks. The equipment includes a 34-foot rotary table, a variable reluctance displacement transducer, an electronics console, a digital computer, and a 5-foot plotter used for final data display.

Melton, R. E.↗

Proposal to Simultaneously Profile Wind and CO2 on Earth and Mars With 2-micron Pulsed Lidar Technologies

2-micron lidar technology has been in use and under continued improvement for many years toward wind measurements. But the 2-micron wavelength region is also rich in absorption lines of CO2 (and H2O to a lesser extent) that can be exploited with the differential absorption lidar (DIAL) technique to make species concentration measurements. A coherent detection receiver offers the possibility of making combined wind and DIAL measurements with wind derived from frequency shift of the backscatter spectrum and species concentration derived from power of the backscatter spectrum. A combined wind and CO2 measurement capability is of interest for applications on both Earth and Mars. CO2 measurements in the Earth atmosphere are of importance to studies of the global carbon cycle. Data on vertically-resolved CO2 profiles over large geographical observations areas are of particular interest that could potentially be made by deploying a lidar on an aircraft or satellite. By combining CO2 concentration with wind measurements an even more useful data product could be obtained in the calculation of CO2 flux. A challenge to lidar in this application is that CO2 concentration measurements must be made with a high level of precision and accuracy to better than 1%. The Martian atmosphere also presents wind and CO2 measurement problems that could be met with a combined DIAL/Doppler lidar. CO2 concentration in this scenario would be used to calculate atmospheric density since the Martian atmosphere is composed of 95% CO2. The lack of measurements of Mars atmospheric density in the 30-60 km range, dust storm formation and movements, and horizontal wind patterns in the 0-20 km range pose significant risks to aerocapture, and entry, descent, and landing of future robotic and human Mars missions. Systematic measurement of the Mars atmospheric density and winds will be required over several Mars years, supplemented with day-of-entry operational measurements. To date, there have been 5 successful robotic landings on Mars. Atmospheric density and wind reconstruction has been performed for 3 of these entries (the two Viking landers and Mars Pathfinder). At present, all Mars atmospheric density and wind models have these 3 entries (at widely scattered positions and seasons) as their basis, supplemented by coarse orbital measurements of atmospheric opacity and temperature. This lack of data leads to a large uncertainty in prediction of the Mars atmospheric density and winds in the altitude regime where deceleration of landers will occur. This uncertainty will have a dramatically large impact on mass, cost and risk. The precision and accuracy for application to Mars is not as stringent as Earth, but Mars does pose a challenge in needing a high level of wavelength stability and control in order to reference wavelength to the narrow linewidths found in the low atmospheric pressure of Mars, as illustrated in Figure 1.

Singh, Upendra N.↗

Ion and laser microprobes applied to the measurement of corrosion-produced hydrogen on a microscopic scale

An ion microprobe and a laser microprobe were used to measure concentrations of corrosion-produced hydrogen on a microscopic scale. Hydrogen concentrations of several thousand ppm were measured by both analytical techniques below the fracture surfaces of hot-salt stress-corroded titanium alloy specimens. This segregation of hydrogen below fracture surfaces supports a previously proposed theory that corrosion-produced hydrogen is responsible for hot-salt stress-corrosion embrittlement and cracking of titanium alloys. These advanced analytical techniques suggest great potential for many areas of stress-corrosion and hydrogen embrittlement research, quality control, and field inspection applications.

Gray, H. R.↗

Effects of Radiative and Diffusive Transport Processes on Premixed Flames near Flammability Limits

A study of the mechanisms of flammability limits and the dynamics of flame extinguishment in premixed gas flames is described, a novel feature of which is the use of diluent gases having a wide range of radiative and diffusive transport properties. This feature enables an assessment of the importance of volumetric heat losses and Lewis number effects on these mechanisms. Additionally, effects of flame dynamics and flame front curvature are studied by employing spherically expanding flames obtained in a microgravity environment whereby natural convection is eliminated. New diagnostics include chamber pressure measurements and the first reported species concentration measurements in a microgravity combustion experiment. The limit mechanisms and extinguishment phenomena are found to be strongly influenced by the combined effects of radiant heat loss, Lewis number and flame curvature. Two new and as yet not well understood phenomena are reported: 'double flames' in rich H2-O2-CO2 mixtures and an 'inverse flammability region' in rich C3H8-O2-CO2 mixtures.

Abbud-Madrid, Angel↗

Measuring Rocket Engine Temperatures with Hydrogen Raman Spectroscopy

Laser-based combustion diagnostics, such as single-pulse UV Raman spectroscopy and visible Raman spectroscopy, have been successfully applied to optically-accessible rocket-like test articles. If an independent pressure measurement is available, Raman major species concentration measurements can also provide a temperature measurement. However it is desirable to obtain a Raman-derived temperature measurement without the need for simultaneous pressure measurement, especially when chamber pressure may vary spatially. This report describes Raman temperature measurements obtained by exploiting the variation in shape of the H2 Raman spectrum. Hydrogen is advantageous since it is ubiquitous in H2-O2 systems and its Raman spectrum is simpler than for other diatomics. However the influence of high pressure on the H2 Raman spectrum must be investigated. At moderate pressures, well below those of rocket engines, the Raman spectra of O2 and N2 are known to become featureless due to collisional broadening.

Joseph A Wehrmeyer↗

Small Business Innovations (Mass Microbalance)

Femtometrics of Costa Mesa, CA, developed the Model 200-1 SAW Mass Microbalance under a NASA Small Business Innovation Research (SBIR) contract with Langley Research Center. The product is described as "the next generation of aerosol mass microbalance technology," because a new type of sensor, the Surface Acoustic Wave (SAW) piezoelectric crystal, offers mass resolution two orders of magnitude greater than the Quartz Crystal Microbalance cascade impactor (QCM) (used at Langley since 1979 for collection and measurement of aerosol particles in the upper atmosphere). The Model 200-1 SAW Mass Microbalance, which provides a 400-fold increase in mass sensitivity per unit area over the QCM, can be used for real-time particle monitoring in clean rooms, measuring chemical vapors in very low concentrations, measuring target chemicals in the stratosphere and in industry as a toxic vapor monitor.

Source record↗

Low and High Speed STOVL Configurations in Ground Effect

The problem of hot gas ingestion in V/STOL and STOVL aircraft has motivated a set of experimental studies. Two-, three-, and four-jet configurations in cross flow were studied in ground effect. The results presented here were based on a quantitative, concentration measurement technique know as marker nephelometry. The effects of configuration, velocity ratio (freestream over jet velocity), model height, and inlet suction were investigated. The experiments were conducted in three parts. In the first part, comparisons of low speed two-, three-, and four-jet configurations were made. Measurements were made in the planes beneath the models in ground effect. As the number of jets increased, the vortical structures in the flowfield were found to move further upstream due to the increased total momentum. In the second part of the experiments, measurements were made at the inlet entry plane of the low speed two- and three-jet configurations in ground effect. The results indicated that ingestion occurred intermittently, especially in the upper portions of the inlets. The highest levels of concentrations were measured at a model height of two jet diameters. As the model height increased, the concentration levels decreased. Finally, a high speed, two-jet configuration without inlet suction was studied. The flowfield structures were generally found to move further downstream as the jet velocity increased at a constant velocity ratio.

Holdeman, James D.↗