Search NASA⌕ Search

SEARCH · Search NASA

Results for “Concurrent Function Evaluations”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Hypofractionated Intensity Modulated Radiation Therapy in Combined Modality Treatment for Bladder Preservation in Elderly Patients With Invasive Bladder Cancer

Purpose/Objective(s): To review our experience with bladder-preserving trimodality treatment (TMT) using hypofractionated intensity modulated radiation therapy (IMRT) for the treatment of elderly patients with muscle-invasive bladder cancer. Methods and Materials: Retrospective study of elderly patients treated with TMT using hypofractionated IMRT (50 Gy in 20 fractions) with concomitant weekly radiosensitizing chemotherapy. Eligibility criteria were as follows: age ≥70 years, a proven diagnosis of muscle-invasive transitional cell bladder carcinoma, stage T2-T3N0M0 disease, and receipt of TMT with curative intent. Response rate was assessed by cystoscopic evaluation and bladder biopsy. Results: 24 patients with a median age of 79 years were eligible. A complete response was confirmed in 83% of the patients. Of the remaining patients, 1 of them underwent salvage cystectomy, and no disease was found in the bladder on histopathologic assessment. After a median follow-up time of 28 months, of the patients with a complete response, 2 patients had muscle-invasive recurrence, 1 experienced locoregional failure, and 3 experienced distant metastasis. The overall and cancer-specific survival rates at 3 years were 61% and 71%, respectively. Of the surviving patients, 75% have a disease-free and functioning bladder. All patients completed hypofractionated IMRT, and 19 patients tolerated all 4 cycles of chemotherapy. Acute grade 3 gastrointestinal or genitourinary toxicities occurred in only 4% of the patients, and acute grade 3 or 4 hematologic toxicities, liver toxicities, or both were experienced by 17% of the cohort. No patient experienced grade 4 gastrointestinal or genitourinary toxicity. Conclusions: Hypofractionated IMRT with concurrent radiosensitizing chemotherapy appears to be an effective and well-tolerated curative treatment strategy in the elderly population and should be considered for patients who are not candidates for cystectomy or who wish to avoid cystectomy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Towards reverse mode automatic differentiation of Kokkos-based codes

Derivative computation is a key component of optimization, sensitivity analysis, uncertainty quantification, and the solving of nonlinear problems. Automatic differentiation (AD) is a powerful technique for evaluating such derivatives, and in recent years, has been integrated into programming environments such as Jax, PyTorch, and TensorFlow to support derivative computations needed for training of machine learning models, facilitating wide-spread use of these technologies. The C++ language has become the de facto standard for scientific computing due to numerous factors, yet language complexity has made the wide-spread adoption of AD technologies for C++ difficult, hampering the incorporation of powerful differentiable programming approaches into C++ scientific simulations. This is exacerbated by the increasing emergence of architectures, such as GPUs, with limited memory capabilities and requiring massive thread-level concurrency. C++ AD tools must effectively use these environments to bring novel scientific simulations to next-generation DOE experimental and observational facilities. In this project, we investigated source transformation-based automatic differentiation using LLVM compiler infrastructure to automatically generate portable and efficient gradient computations of Kokkos-based code. We have demonstrated that our proposed strategy is feasible by investigating the usage of a prototype LLVM-based source transformation tool to generate gradients of simple functions made of sequences of simple Kokkos parallel regions. Speedups of up to 500x compared to Sacado were observed on NVIDIA V100 GPU.

97 MATHEMATICS AND COMPUTING↗

Mesoscale modeling of restructuring in high burnup UO 2 fuel

Here, this work aims to simulate the restructuring behavior observed in different regions of high burnup fuel, providing a first-of-its-kind restructuring model for the dark zone and rim region of high-burnup UO 2 fuel. We employed a grand-potential-based phase-field model to concurrently evaluate subgrain formation and the growth of fission gas bubbles within the fuel. An energy-based subgrain formation criterion was introduced to simulate the restructuring process. The effects of different initial conditions and different modeling parameters were systematically studied to capture how each of these parameters influences the characteristics of the restructured fuel. Subgrain formation was observed to begin around existing fission gas bubbles and proceed toward triple junctions, grain boundaries, and grain interiors. Restructuring was demonstrated to be influenced by a combination of initial dislocation densities, burnup rate, subgrain formation rate, and temperature. Under a given subgrain formation rate, the rate of restructuring increases with rising fuel temperature. A restructuring bias was observed within the microstructure, due to the variation in defect accumulation when comparing different grains. Microstructures corresponding to the dark zone and rim region can be obtained by parameterizing the model with the appropriate defect production rate, as determined based on the burnup rate and temperature. Furthermore, bubble size and distribution do not significantly affect the rate of restructuring. The predicted microstructures are consistent with experimental observations of the restructured regions. Finally, we present a correlation demonstrating the evolution of the restructuring volume fraction as a function of local burnup.

UO2↗

Clinical Outcomes of Definitive Intensity-Modulated Radiation Therapy With Fluorodeoxyglucose-Positron Emission Tomography Simulation in Patients With Locally Advanced Cervical Cancer

Purpose: This study aimed to evaluate the toxicity and clinical outcomes for cervical cancer patients treated definitively with intensity-modulated radiation therapy (IMRT) compared with non-IMRT treatment. Methods and Materials: This prospective cohort study included 452 patients with newly diagnosed cervical cancer treated with curative intent (135 IMRT and 317 non-IMRT). Treatment involved external irradiation and brachytherapy, and 85% of patients received concurrent chemotherapy. All IMRT patients underwent an F-18 fluorodeoxyglucose positron emission tomography (FDG-PET/CT) simulation. A 3-month post-therapy PET was obtained to evaluate treatment response. Toxicity was scored by the Common Terminology Criteria for Adverse Events Version 3.0. Results: The IMRT and non-IMRT groups had similar stage distribution and histology. For all patients, the post-therapy FDG-PET response correlated with overall recurrence risk (p < 0.0001) and cause-specific survival (p < 0.0001). Post-treatment FDG-PET findings were not significantly different between the IMRT and non-IMRT patients (p = 0.9774). The mean follow-up for all patients alive at the time of last follow-up was 52 months (72 months non-IMRT, 22 months IMRT). At last follow-up, 178 patients (39 IMRT, 139 non-IMRT) had developed a recurrence. The difference in recurrence-free survival between the two groups did not reach statistical significance (p = 0.0738), although the IMRT group showed better overall and cause-specific survivals (p < 0.0001). Of the patients, 62 patients (8 IMRT and 54 non-IMRT) developed Grade 3 or greater bowel or bladder complications, and by cumulative hazard function analysis the risk was significantly less for patients treated with IMRT (p = 0.0351). Conclusion: Cervical cancer patients treated with FDG-PET/CT-guided IMRT have improved survival and less treatment-related toxicity compared with patients treated with non-IMRT radiotherapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Tumor-Volume Simulation During Radiotherapy for Head-and-Neck Cancer Using a Four-Level Cell Population Model

Purpose: To develop a fast computational radiobiologic model for quantitative analysis of tumor volume during fractionated radiotherapy. The tumor-volume model can be useful for optimizing image-guidance protocols and four-dimensional treatment simulations in proton therapy that is highly sensitive to physiologic changes. Methods: The analysis is performed using two approximations: (1) tumor volume is a linear function of total cell number and (2) tumor-cell population is separated into four subpopulations: oxygenated viable cells, oxygenated lethally damaged cells, hypoxic viable cells, and hypoxic lethally damaged cells. An exponential decay model is used for disintegration and removal of oxygenated lethally damaged cells from the tumor. Results: We tested our model on daily volumetric imaging data available for 14 head-and-neck cancer patients treated with an integrated computed tomography/linear accelerator system. A simulation based on the averaged values of radiobiologic parameters was able to describe eight cases during the entire treatment and four cases partially (50% of treatment time) with a maximum 20% error. The largest discrepancies between the model and clinical data were obtained for small tumors, which may be explained by larger errors in the manual tumor volume delineation procedure. Conclusions: Our results indicate that the change in gross tumor volume for head-and-neck cancer can be adequately described by a relatively simple radiobiologic model. In future research, we propose to study the variation of model parameters by fitting to clinical data for a cohort of patients with head-and-neck cancer and other tumors. The potential impact of other processes, like concurrent chemotherapy, on tumor volume should be evaluated.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Photon-counting hexagonal pixel array CdTe detector: Spatial resolution characteristics for image-guided interventional applications

Purpose: High-resolution, photon-counting, energy-resolved detector with fast-framing capability can facilitate simultaneous acquisition of precontrast and postcontrast images for subtraction angiography without pixel registration artifacts and can facilitate high-resolution real-time imaging during image-guided interventions. Hence, this study was conducted to determine the spatial resolution characteristics of a hexagonal pixel array photon-counting cadmium telluride (CdTe) detector. Methods: A 650 μm thick CdTe Schottky photon-counting detector capable of concurrently acquiring up to two energy-windowed images was operated in a single energy-window mode to include photons of 10 keV or higher. The detector had hexagonal pixels with apothem of 30 μm resulting in pixel pitch of 60 and 51.96 μm along the two orthogonal directions. The detector was characterized at IEC-RQA5 spectral conditions. Linear response of the detector was determined over the air kerma rate relevant to image-guided interventional procedures ranging from 1.3 nGy/frame to 91.4 μGy/frame. Presampled modulation transfer was determined using a tungsten edge test device. The edge-spread function and the finely sampled line spread function accounted for hexagonal sampling, from which the presampled modulation transfer function (MTF) was determined. Since detectors with hexagonal pixels require resampling to square pixels for distortion-free display, the optimal square pixel size was determined by minimizing the root-mean-squared-error of the aperture functions for the square and hexagonal pixels up to the Nyquist limit. Results: At Nyquist frequencies of 8.33 and 9.62 cycles/mm along the apothem and orthogonal to the apothem directions, the modulation factors were 0.397 and 0.228, respectively. For the corresponding axis, the limiting resolution defined as 10% MTF occurred at 13.3 and 12 cycles/mm, respectively. Evaluation of the aperture functions yielded an optimal square pixel size of 54 μm. After resampling to 54 μm square pixels using trilinear interpolation, the presampled MTF at Nyquist frequency of 9.26 cycles/mm was 0.29 and 0.24 along the orthogonal directions and the limiting resolution (10% MTF) occurred at approximately 12 cycles/mm. Visual analysis of a bar pattern image showed the ability to resolve close to 12 line-pairs/mm and qualitative evaluation of a neurovascular nitinol-stent showed the ability to visualize its struts at clinically relevant conditions. Conclusions: Hexagonal pixel array photon-counting CdTe detector provides high spatial resolution in single-photon counting mode. After resampling to optimal square pixel size for distortion-free display, the spatial resolution is preserved. The dual-energy capabilities of the detector could allow for artifact-free subtraction angiography and basis material decomposition. The proposed high-resolution photon-counting detector with energy-resolving capability can be of importance for several image-guided interventional procedures as well as for pediatric applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Solids Erosion Patterns Developed by Pulse Jet Mixers

Millions of gallons of radioactive waste are stored in underground storage tanks at the Hanford Site in Washington State. This waste will be vitrified at the Waste Treatment and Immobilization Plant that is under construction. Vessels in the pretreatment portion of the plant are being configured for processing waste slurries with challenging physical and rheological properties that range from Newtonian slurries to non-Newtonian sludge. Pulse jet mixing technology has been selected for mobilizing and mixing this waste. In the pulse jet mixing process, slurry is expelled from pulse tube nozzles directed towards the vessel floor. The expelled fluid forms a radial jet that erodes the settled layer of solids. The pulse tubes are configured in a ring or multiple rings and operate concurrently. The expelled fluid and mobilized solids traverse toward the center of the tank. At the tank center the jets from pulse tubes in the ring collide and lift solids upward in a central plume. At the end of the pulse, when the desired fluid volume is expelled from the pulse tube, the applied pressure switches to suction and the pulse tube is refilled. This cycle is used to mobilize and mix the tank contents. An initial step of the process is the erosion of solids from the vessel floor by the radial jets that form on the vessel flow beneath each pulse tube. Experiments have been conducted using simulants to evaluate the ability of the pulse jet mixing system radial jets to combine to develop the central upwell and lift solids into the vessel. These experiments have been conducted at three scales using a range of granular simulants over a range of concentrations. The vessels have elliptical, spherical, or flanged and dished bottoms. Process parameters evaluated include the velocity of fluid expelled from the pulse tube, the duration of the pulse and the duty cycle, the ratio of pulse duration to cycle time. Videos taken from beneath the vessel show the growth of the cleared area from each pulse tube as a function of time. All solids are lifted from the vessel bottom when the system is operating at the critical suspension velocity. The focus of this paper is to compare and contrast erosion patterns developed from different simulants and pulse tube configurations. The cases are evaluated to determine how changes in process parameters affects the PJM ability to mobilize solids from the vessel floor.

erosion↗

Alterations in Hormone Levels After Adjuvant Chemoradiation in Male Rectal Cancer Patients

Purpose: To evaluate follicle-stimulating hormone (FSH), luteinizing hormone (LH), and testosterone levels after postoperative chemoradiation in men with rectal cancer. Methods and Materials: Forty-three men with rectal cancer had baseline and postchemoradiation FSH, LH, and testosterone measured. Adjuvant chemoradiation consisted of two 5-day cycles of bolus 5-fluorouracil (5-FU) every 4 weeks at a dose of 500 mg/m{sup 2}/d followed by concurrent chemoradiation followed by two additional 5-day cycles of 5-FU at a dose of 450 mg/m{sup 2}/d. Continuous-infusion 5-FU at 225 mg/m{sup 2}/d was given during radiation. Pelvic radiation consisted of a three- or four-field technique with a median dose of 54.0 Gy in 30 fractions. Results: Median follow-up was 6.1 years. Mean baseline FSH levels increased from 5.3 to a peak of 23.9 IU/L (p < 0.001) 13-24 months after chemoradiation. Mean baseline LH levels increased from 4.3 to a peak of 8.5 IU/L (p < 0.001) within 6 months after chemoradiation. Mean testosterone levels decreased from 15.4 nmol/L at baseline to 8.0 nmol/L more than 4 years after chemoradiation. Mean testosterone to mean LH ratio decreased from 4.4 at baseline to 1.1 after 48 months posttreatment, suggesting a continued decrease in Leydig cell function with time. Testicular dose was measured in 5 patients. Median dose was 4 Gy (range, 1.5-8.9 Gy). Conclusions: Chemoradiation in men with rectal cancer causes persistent increases in FSH and LH levels and decreases in testosterone levels.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Characterization of intact N- and O-linked glycopeptides using higher energy collisional dissociation

Simultaneous elucidation of the glycan structure and the glycosylation site are needed to reveal the biological function of protein glycosylation. In this study, we employed a recent type of fragmentation termed higher energy collisional dissociation (HCD) to examine fragmentation patterns of intact glycopeptides generated from a mixture of standard glycosylated proteins. The normalized collisional energy (NCE) value for HCD was varied from 30% to 60% to evaluate the optimal conditions for the fragmentation of peptide backbones and glycoconjugates. Our results indicated that HCD with lower NCE valuespreferentially fragmented the sugar chains attached to the peptides to generate a ladder of neutral loss of monosaccharides, thus enabling the putative glycan structure characterization. Also, detection of the oxonium ions enabled unambiguous differentiation of glycopeptides from non-glycopeptides. On the contrary, HCD with higher NCE values preferentially fragmented the peptide backbone and thus provided information needed for confident peptide identification. We evaluated the HCD approach with alternating NCE parameters for confident characterization of intact N-linked and O-linked glycopeptides in a single liquid chromatography-tandem mass spectrometry (LC-MS/MS) analysis. In addition, we applied a novel data analysis pipeline, so-called GlycoFinder, to form a basis for automated data analysis. Overall, 38 unique intact glycopeptides corresponding to eight glycosylation sites (including six N-linked and two O-linked sites) were confidently identified from a standard protein mixture. This approach provided concurrent characterization of both, the peptide and the glycan, thus enabling comprehensive structural characterization of glycoproteins in a single LC-MS/MS analysis.

automated identification↗

Corrosion of Aluminum in the Chemical Environment after a Loss of Coolant Accident (LOCA)

Probabilistic assessment of Generic Safety Issue (GSI)- 191 generated further studies to improve the characterization of post-Loss of Coolant Accident (LOCA) aluminum release from corrosion sources, since the current industry approach of assessing aluminum release is only valid for deterministic assessments of GSI-191. The nuclear industry has long accepted that solution pH, solution temperature, sump chemical constituents and the phenomena of silicate or phosphate 'inhibition' affects the quantity of aluminum released and the quality of results obtained from models used to predict aluminum release. While improvements in the characterization of aluminum release has been made, the impacts of solution velocity, concurrent corrosion of other metals [6], and trace amount of chemical constituents such as chloride and sulfate ions on aluminum release in post-LOCA conditions have not been assessed. Those factors are well known to influence aluminum corrosion, and will be investigated in this work. The effect of flow on aluminum corrosion rate is characterized using different hydrodynamic system, which has not been investigated in GSI-191 related studies. The corrosion rate depends on the mass-transfer rate which is a function of flow velocity and flow pattern. The inhibition effect of silicon on aluminum corrosion is characterized, and the representative silicon concentration in post-LOCA condition has the potential to significantly inhibit the aluminum corrosion rate. The experiments that investigated silicon effects on aluminum corrosion also showed that calcium leached from Cal-sil can slow corrosion and that the silicon inhibition effect on aluminum corrosion became less pronounced at higher temperature and lower pH. Trace chloride and fluoride ions slightly increased aluminum corrosion rate, and the presence of sulfite ions could mitigate this harmful effect. The corrosion of zinc significantly retarded the aluminum corrosion rate, while presence of copper and carbon steel has little effect on aluminum corrosion in both galvanic and non-galvanic corrosion cases. This work is not complete and is currently evaluating high temperature (>95 C) test with all parameters mentioned and evaluation of the effects on variable boron concentrations at set conditions; Therefore an improved aluminum release model for probabilistic aluminum release model is not proposed. However, this work shows the important impact on aluminum corrosion of parameters not characterized by other studies. To obtain representative aluminum release results for use in GSI-191 probabilistic analysis, the model should be built on data obtained from experiments that account for all parameters that may impact aluminum corrosion and release. (authors)

36 MATERIALS SCIENCE↗

Incorporating root hydraulic redistribution in CLM4.5: Effects on predicted site and global evapotranspiration, soil moisture, and water storage

We implemented the Amenu-Kumar model in the Community Land Model (CLM4.5) to simulate plant Root Hydraulic Redistribution (RHR) and analyzed its influence on CLM hydrology from site to global scales. We evaluated two numerical implementations: the first solved the coupled equations of root and soil water transport concurrently, while the second solved the two equations sequentially. Through sensitivity analysis, we demonstrate that the sequentially coupled implementation (SCI) is numerically incorrect, whereas the tightly coupled implementation (TCI) is numerically robust with numerical time steps varying from 1 to 30 min. At the site-level, we found the SCI approach resulted in better agreement with measured evapotranspiration (ET) at the AmeriFlux Blodgett Forest site, California, whereas the two approaches resulted in equally poor agreement between predicted and measured ET at the LBA Tapajos KM67 Mature Forest site in Amazon, Brazil. Globally, the SCI approach overestimated annual land ET by as much as 3.5 mm d -1 in some grid cells when compared to the TCI estimates. These comparisons demonstrate that TCI is a more robust numerical implementation of RHR. However, we found, even with TCI, that incorporating RHR resulted in worse agreement with measured soil moisture at both the Blodgett Forest and Tapajos sites and degraded the agreement between simulated terrestrial water storage anomaly and Gravity Recovery and Climate Experiment (GRACE) observations. We find including RHR in CLM4.5 improved ET predictions compared with the FLUXNET-MTE estimates north of 20° N but led to poorer predictions in the tropics. The biases in ET were robust and significant regardless of the four different pedotransfer functions or of the two meteorological forcing data sets we applied. We also found that the simulated water table was unrealistically sensitive to RHR. Therefore, we contend that further structural and data improvements are warranted to improve the hydrological dynamics in CLM4.5.

58 GEOSCIENCES↗

Prospective Study of Hippocampal-Sparing Prophylactic Cranial Irradiation in Limited-Stage Small Cell Lung Cancer

Purpose: To prospectively evaluate cognitive function and intracranial failure patterns after hippocampal-sparing prophylactic cranial irradiation (PCI) for limited-stage small cell lung cancer (SCLC). Methods and Materials: Adults with limited-stage SCLC, achieving a complete response to chemoradiotherapy and no brain metastases, were eligible. Patients received PCI 25 Gy/10 fractions, with a mean hippocampal dose limited to <8 Gy and ≥90% of the brain receiving 90% of the prescription. A diverse battery of neuropsychological testing was performed at baseline and 6 and 12 months after PCI. Brain MRI scans were performed at baseline and 6, 12, 18, and 24 months. The primary endpoint was memory measured by the Hopkins Verbal Learning Test-Revised Delayed Recall at 6 months after PCI. The 25-Gy arm of Radiation Therapy Oncology Group protocol 0212 was used as a reference of potential efficacy. Development of intracranial metastases was recorded. Overall survival and progression-free survival were estimated using the Kaplan-Meier method. Results: Eight men and 12 women with a median age of 61 years enrolled. Two-year overall survival was 88% (95% confidence interval 68%-100%). There was no significant decline in performance between baseline and 6 or 12 months for any of the tests. The association between baseline intelligence quotient and change in performance on testing was not significant. Magnetic resonance imaging revealed asymptomatic brain metastases at a cumulative rate of 20%, with no concurrent extracranial progression. Two patients developed a metastasis in the under-dosed region. Neither involved the dentate gyrus, but 1 involved the avoidance region. Both patients concurrently developed additional metastasis in fully treated brain regions. There were 2 neurologic deaths. Conclusions: This prospective study suggests a potential benefit of hippocampal sparing in limiting the neuropsychological sequelae of brain radiation, but with a risk of failures in the spared region. These data strongly support continued enrollment on ongoing cooperative group randomized trials. Clinical Trials registration number: (NCT01797159).

62 RADIOLOGY AND NUCLEAR MEDICINE↗

ARCADE Analysis Methods & Validation Pathway

The Advanced Reactor Cyber Analysis and Development Environment (ARCADE) provides an automated analysis system which supports risk-informed performance based (RIPB) evaluations of nuclear control systems. Every possible cyber threat which could lead to consequence is identified by simulating the unsafe control action sequences which transform digital harm into physical harm. Eliminating the simulation of complex digital cyber attack chains cuts out unnecessary computational overhead and focuses directly on the physics of cyber-physical attacks. This focus enables designers to make informed decisions which can entirely eliminate categories of cyber threats against advanced reactors through the physical nature of the plant design. This narrowing of cyber threat against nuclear power plants through the physics of the system is intended to make any remaining threat management and cost efficient. This is the goal of the Tiered Cyber Analysis (TCA) outlined in NRC Draft Regulation Guide (RG) 5.96, which provides a RIPB cybersecurity approach for new reactors. ARCADE has been custom developed to meet the demands of the rigorous analysis required in Tier 1 of the TCA, which forms the foundation of the TCA process. Currently, ARCADE is still under development, but has made significant leaps in capability. A pilot analysis on the opensource Asherah simulator was performed which demonstrated key functionality goals. The next stage of ARCADE development involves improvements to the applications which support the analysis system, and enabling the analysis system to utilize the full suite of unsafe control action simulations. Since the analysis method’s core functions are complete, validation of the analysis method will be started concurrent to the next development stages. The automated analysis ARCADE will provide can radically change the cybersecurity design process for advanced reactors, reducing the cost of security implementation while enhancing cyber resilience. The pathway for ARCADE’s development to this goal has become much clearer. The majority of technical hurdles have been cleared, and the remaining development needs have been solidified. ARCADE is now capable of assisting the advanced reactor design process and directly support advanced reactor industry RIPB practices.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Induction Cisplatin and Fluorouracil-Based Chemotherapy Followed by Concurrent Chemoradiation for Muscle-Invasive Bladder Cancer

Purpose: To evaluate a multimodality bladder-preserving therapy in patients with muscle-invasive bladder cancer. Methods and Materials: Patients with stages T2-4aN0M0 bladder cancer suitable for cystectomy underwent radical transurethral resection and induction chemotherapy, followed by concurrent chemoradiotherapy (CCRT). Patients with a Karnofsky performance status (KPS) <80 or age {>=}70 years underwent Protocol A: induction chemotherapy with three cycles of the cisplatin and 5-fluorouracil (CF) regimen, and CCRT with six doses of weekly cisplatin and 64.8 Gy radiotherapy given with the shrinking-field technique. Patients with KPS {>=}80 and age <70 years underwent Protocol B: induction chemotherapy with three cycles of weekly paclitaxel plus the CF regimen, and CCRT with six doses of weekly paclitaxel and cisplatin plus 64.8 Gy radiotherapy. Interval cystoscopy was employed after induction chemotherapy and when radiotherapy reached 43.2 Gy. Patients without a complete response (CR) were referred for salvage cystectomy. Results: Among 30 patients (median, 66 years) enrolled, 17 and 13 patients underwent Protocol A and B, respectively. After induction chemotherapy, 23 patients achieved CR. Five (17%) of 7 patients without CR underwent salvage cystectomy. Overall, 28 patients (93%) completed the protocol treatment. Of 22 patients who completed CCRT, 1 had recurrence with carcinoma in situ and 3 had distant metastases. After a median follow-up of 47 months, overall and progression-free survival rate for all patients were 77% and 54% at 3 years, respectively. Of 19 surviving patients, 15 (79%) retained functioning bladders. Conclusions: Our protocols may be alternatives to cystectomy for selected patients who wish to preserve the bladder.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Organ Preservation With Daily Concurrent Chemoradiotherapy Using Superselective Intra-Arterial Infusion via a Superficial Temporal Artery for T3 and T4 Head and Neck Cancer

Purpose: To evaluate the therapeutic results and rate of organ preservation in patients with advanced head and neck cancer treated with superselective intra-arterial chemotherapy via a superficial temporal artery and daily concurrent radiotherapy. Methods and Materials: Between April 2002 and March 2006, 30 patients with T3 or T4a squamous cell carcinoma of the head and neck underwent intra-arterial chemoradiotherapy. Treatment consisted of superselective intra-arterial infusions (docetaxel, total 60 mg/m{sup 2}; cisplatin, total 150 mg/m{sup 2}) and daily concurrent radiotherapy (total, 60 Gy) for 6 weeks. Results: The median follow-up for all patients was 46.2 months (range, 10-90 months). The median follow-up for living patients was 49.7 months (range, 36-90 months). After intra-arterial chemoradiotherapy was administered, primary site complete response was achieved in 30 (100%) of 30 cases. Seven patients (23.3%) died. Using the Kaplan-Meier method, 1-year, 3-year, and 5-year survival rates were 96.7%, 83.1%, and 70.2%, respectively, while 1-year, 3-year, and 5-year local control rates were 83.3%, 79.7%, and 73.0%, respectively. Grade 3 or 4 mucositis occurred in 20 cases (66.7%). Grade 3 toxicities included dysphagia in 20 cases (66.7%), dermatitis in 6 cases (20%), nausea/vomiting in 2 cases (6.7%), and neutropenia and thrombocytopenia in 1 case (3.3%). No osteoradionecrosis of mandible and maxillary bones developed during follow-up. Conclusions: Intra-arterial chemoradiotherapy using a superficial temporal artery provided good overall survival and local control rates. This combination chemoradiotherapy approach can preserve organs and minimize functional disturbance, thus contributing to patients' quality of life.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Prospective Evaluation of Acute Toxicity and Quality of Life After IMRT and Concurrent Chemotherapy for Anal Canal and Perianal Cancer

Purpose: A prospective cohort study was conducted to evaluate toxicity, quality of life (QOL), and clinical outcomes in patients treated with intensity modulated radiation therapy (IMRT) and concurrent chemotherapy for anal and perianal cancer. Methods and Materials: From June 2008 to November 2010, patients with anal or perianal cancer treated with IMRT were eligible. Radiation dose was 27 Gy in 15 fractions to 36 Gy in 20 fractions for elective targets and 45 Gy in 25 fractions to 63 Gy in 35 fractions for gross targets using standardized, institutional guidelines, with no planned treatment breaks. The chemotherapy regimen was 5-fluorouracil and mitomycin C. Toxicity was graded with the National Cancer Institute Common Terminology Criteria for Adverse Events, version 3. QOL was assessed with the European Organization for Research and Treatment of Cancer (EORTC) QLQ-C30 and CR29 questionnaires. Correlations between dosimetric parameters and both physician-graded toxicities and patient-reported outcomes were evaluated by polyserial correlation. Results: Fifty-eight patients were enrolled. The median follow-up time was 34 months; the median age was 56 years; 52% of patients were female; and 19% were human immunodeficiency virus—positive. Stage I, II, III, and IV disease was found in 9%, 57%, 26%, and 9% of patients, respectively. Twenty-six patients (45%) required a treatment break because of acute toxicity, mainly dermatitis (23/26). Acute grade 3 + toxicities included skin 46%, hematologic 38%, gastrointestinal 9%, and genitourinary 0. The 2-year overall survival (OS), disease-free survival (DFS), colostomy-free survival (CFS), and cumulative locoregional failure (LRF) rates were 90%, 77%, 84%, and 16%, respectively. The global QOL/health status, skin, defecation, and pain scores were significantly worse at the end of treatment than at baseline, but they returned to baseline 3 months after treatment. Social functioning and appetite scores were significantly better at 12 months than at baseline. Multiple dose-volume parameters correlated moderately with diarrhea, skin, and hematologic toxicity scores. Conclusion: IMRT reduces acute grade 3 + hematologic and gastrointestinal toxicities compared with reports from non-IMRT series, without compromising locoregional control. The reported QOL scores most relevant to acute toxicities returned to baseline by 3 months after treatment.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

CHESS 2025: Discrete-return LiDAR point clouds from NEON AOP surveys

This dataset provides Level 1 (L1) discrete-return light detection and ranging (LiDAR) point cloud data collected for the 2025 Colorado Headwaters Ecological Spectroscopy Study (CHESS). These data were acquired to enable characterization of vegetation structure and other three-dimensional features of the land surface, and to evaluate structural changes that may have occurred between a prior LiDAR acquisition in 2018 and the 2025 overflight. The data were acquired over three study domains in the Upper Gunnison river basin: the upper East River watershed (CRBU); Almont Triangle and Taylor Canyon (ALMO); and Upper Taylor River watershed (UPTA) between 2025-06-13 and 2025-07-15. LiDAR data were acquired using the Optech Galaxy Prime Airborne LiDAR Terrain Mapper onboard the National Ecological Observatory Network (NEON) Airborne Observation Platform (AOP). These are the primary unclassified discrete-return LiDAR data delivered by NEON and are provided per flightline as LASzip (LAZ) 1.4 Format 6 files. Data were processed following the workflow described in the NEON L0-to-L1 Discrete Return LiDAR Algorithm Theoretical Basis Document (Krause and Goulden 2022). Each record in the unclassified point clouds represents a geolocated laser target/return recorded by the LiDAR system, with values for X, Y, Z position and return intensity. All point coordinates are provided in meters. Horizontal coordinates are referenced in Universal Transverse Mercator (UTM) zone 13N and the World Geodetic System (WGS) 1984 ensemble datum. Elevations are referenced to Geoid12A. Flight metadata describing flightline boundaries and positional uncertainty by point are also included. CHESS Project Description: The Colorado Headwaters Ecological Spectroscopy Study (CHESS) comprised a multi-week airborne remote sensing and field observation campaign in the Upper Gunnison Basin, Colorado, conducted in June and July of 2025. Airborne remote sensing was conducted by the National Ecological Observatory Network Airborne Observation Platform (NEON AOP), concurrent with a field campaign run by the Rocky Mountain Biological Laboratory (RMBL), the Lawrence Berkeley National Laboratory (LBNL) and SLAC National Accelerator Laboratory Watershed Function Science Focus Area (SFA), and NASA-JPL (Jet Propulsion Laboratory) Earth Surface Mineral Dust Source Investigation (EMIT) program. Between June 10 and July 18, 2025, the NEON AOP flight team collected high-resolution aerial imaging spectroscopy and Light Detection and Ranging (LiDAR) data over three domains: the Upper East River (CRBU), Almont Triangle (ALMO), and the Upper Taylor Basin (UPTA). In coordination with the flights, a field campaign acquired ground-truth observations, including observations of vegetation composition, foliar traits, forest demography, and subsurface properties in 18 core sampling areas within the domains. Additional surface water observations were taken at over 380 point locations. All CHESS campaign datasets can be found within the CHESS ESS-DIVE data portal: https://data.ess-dive.lbl.gov/portals/chess. Funding Acknowledgement: Field and remote-sensing data acquisition was performed under a grant from the National Aeronautics and Space Administration (80NSSC24K1005). This work was also supported by the Watershed Function Science Focus Area at Lawrence Berkeley National Laboratory funded by the US Department of Energy, Office of Science, Biological and Environmental Research under Contract No. DE-AC02-05CH11231.

2018 NEON and 2025 CHESS Campaigns↗

User Guide for VISION 3.4.7 (Verifiable Fuel Cycle Simulation) Model

The purpose of this document is to provide a guide for using the current version of the Verifiable Fuel Cycle Simulation (VISION) model. This is a complex model with many parameters and options; the user is strongly encouraged to read this user guide before attempting to run the model. This model is an R&D work in progress and may contain errors and omissions. It is based upon numerous assumptions. This model is intended to assist in evaluating 'what if' scenarios and in comparing fuel, reactor, and fuel processing alternatives at a systems level. The model is not intended as a tool for process flow and design modeling of specific facilities nor for tracking individual units of fuel or other material through the system. The model is intended to examine the interactions among the components of a fuel system as a function of time varying system parameters; this model represents a dynamic rather than steady-state approximation of the nuclear fuel system. VISION models the nuclear cycle at the system level, not individual facilities, e.g., 'reactor types' not individual reactors and 'separation types' not individual separation plants. Natural uranium can be enriched, which produces enriched uranium, which goes into fuel fabrication, and depleted uranium (DU), which goes into storage. Fuel is transformed (transmuted) in reactors and then goes into a storage buffer. Used fuel can be pulled from storage into either separation or disposal. If sent to separations, fuel is transformed (partitioned) into fuel products, recovered uranium, and various categories of waste. Recycled material is stored until used by its assigned reactor type. VISION is comprised of several Microsoft Excel input files, a Powersim Studio core, and several Microsoft Excel output files. All must be co-located in the same folder on a PC to function. You must use Powersim Studio 8 or better. We have tested VISION with the Studio 8 Expert, Executive, and Education versions. The Expert and Education versions work with the number of reactor types of 3 or less. For more reactor types, the Executive version is currently required. The input files are Excel2003 format (xls). The output files are macro-enabled Excel2007 format (xlsm). VISION 3.4 was designed with more flexibility than previous versions, which were structured for only three reactor types - LWRs that can use only uranium oxide (UOX) fuel, LWRs that can use multiple fuel types (LWR MF), and fast reactors. One could not have, for example, two types of fast reactors concurrently. The new version allows 10 reactor types and any user-defined uranium-plutonium fuel is allowed. (Thorium-based fuels can be input but several features of the model would not work.) The user identifies (by year) the primary fuel to be used for each reactor type. The user can identify for each primary fuel a contingent fuel to use if the primary fuel is not available, e.g., a reactor designated as using mixed oxide fuel (MOX) would have UOX as the contingent fuel. Another example is that a fast reactor using recycled transuranic (TRU) material can be designated as either having or not having appropriately enriched uranium oxide as a contingent fuel. Because of the need to study evolution in recycling and separation strategies, the user can now select the recycling strategy and separation technology, by year.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗