Search NASA⌕ Search

SEARCH · Search NASA

Results for “Continued Rotation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Compatibility of the Space Station Freedom life sciences research centrifuge with microgravity requirements

NASA is developing a Life Sciences Centrifuge Facility for Space Station Freedom. In includes a 2.5-meter artificial gravity Bioresearch Centrifuge (BC), which is perhaps the most critical single element in the life sciences space research program. It rotates continuously at precise selectable rates, and utilizes advanced reliable technologies to reduce vibrations. Three disturbance types are analyzed using a current Space Station Freedom dynamic model in the 0.0 to 5.0 Hz range: sinusoidal, random, and transient. Results show that with proper selection of proven design techniques, BC vibrations are compatible with requirements.

Hasha, Martin D.↗

Quick application/release nut with engagement indicator (commercial application of an innovative nut design)

This is an assembly which permits a fastener to be inserted or removed from either side with an indicator of fastener engagement. The nut has a plurality of segments, preferably at least three segments, which are internally threaded, spring loaded apart by an internal spring, and has detents on opposite sides which force the nut segments into operative engagement with a threaded member when pushed in and release the segments for quick insertion or removal of the fastener when moved out. When the nut is installed, end pressure on the detents presses the nut segments into operative engagement with a threaded member where continued rotation locks the structure together with the detents depressed to indicate positive locking engagement of the nut. On removal, counterclockwise rotation relieves the endwise pressure on the detents, permitting internal springs to force the detents outward, allowing the nut segments to move outward and separate to permit quick removal of the fastener.

Wright, Jay M.↗

Quick application/release nut with engagement indicator

A composite nut is shown which permits a fastener to be inserted or removed from either side with an indicator of fastener engagement. The nut has a plurality of segments, preferably at least three segments, which are internally threaded, spring loaded apart by an internal spring, and has detents on opposite sides which force the nut segments into operative engagements with a threaded member when pushed in and release the segments for quick insertion or removal of the nut when moved out. When the nut is installed, end pressure on one of the detents presses the nut segments into operative engagement with a threaded member where continued rotation locks the structure together with the detents depressed to indicate positive locking engagement of the nut. On removal, counterclockwise rotation of the nut relieves the endwise pressure on the detents, permitting internal springs to force the detents outward and allowing the nut segments to move outward and separate to permit quick removal of the fastener.

Wright, Jay M.↗

Long-term effects of microgravity and possible countermeasures

The measures that can be taken to counteract the effect of long-term exposures to microgravity are discussed. It is noted that, although it was shown that specially designed exercise programs can counteract the effect of exposures of up to one year in space, is it questionable whether U.S. astronauts could or should have to maintain such regimes for extremely prolonged missions. The methods considered by NASA Life Sciences Division are to provide an artificial gravity environment by the generation of centrifugal forces by means of either the continuous rotation of the whole spacecraft or using a short-arm centrifuge on board a zero-g spacecraft. Results obtained in studies of these two methods are discussed, and the centrifuge research facility that is presently being developed by NASA is described.

Wolfe, James W.↗

Flex-gear electrical power transmission

This study was conducted to develop an alternative way of transferring electricity across a continuously rotating joint, with little wear and the potential for low electrical noise. The problems with wires, slip rings, electromagnetic couplings, and recently invented roll-rings are discussed. Flex-gears, an improvement of roll-rings, are described. An entire class of flexgear devices is developed. Finally, the preferred flex-gear device is optimized for maximum electrical contact and analyzed for average mechanical power loss and maximum stress. For a device diameter of six inches, the preferred device is predicted to have a total electrical contact area of 0.066 square inches. In the preferred device, a small amount of internal sliding produces a 0.003 inch-pound torque that resists the motion of the device.

Vranish, John↗

USML-1 microgravity glovebox experiment no. 1 Passive Accelerometer System

The passive accelerometer system (PAS) is a simple moving ball accelerometer capable of measuring the small magnitude steady relative acceleration that occurs in a low earth orbit spacecraft due to atmospheric drag and the earth's gravity gradient. The accelerometer can be used when the spacecraft continuously rotates during the orbit such that some line of reference in the craft always points along the vector connecting the earth's mass center with the spacecraft mass center. PAS was used successfully on the first United States Microgravity Laboratory (USML-1).

Alexander, J. Iwan D.↗

Baseline acoustic levels of the NASA Active Noise Control Fan rig

Extensive measurements of the spinning acoustic mode structure in the NASA 48 inch Active Noise Control Fan (ANCF) test rig have been taken. A continuously rotating microphone rake system with a least-squares data reduction technique was employed to measure these modes in the inlet and exhaust. Farfield directivity patterns in an anechoic environment were also measured at matched corrected rotor speeds. Several vane counts and spacings were tested over a range of rotor speeds. The Eversman finite element radiation code was run with the measured in-duct modes as input and the computed farfield results were compared to the experimentally measured directivity pattern. The experimental data show that inlet spinning mode measurements can be made very accurately. Exhaust mode measurements may have wake interference, but the least-squares reduction does a good job of rejecting the non-acoustic pressure. The Eversman radiation code accurately extrapolates the farfield levels and directivity pattern when all in-duct modes are included.

Sutliff, Daniel L.↗

Prospects of Measuring Atmospheric Winds with a 2-Micron Coherent Doppler Lidar from the International Space Station

The measurement of global winds in the troposphere is often cited as the most important single missing element of our present weather and climate observing system. The most promising technique for filling this gap is with space-based coherent Doppler lidar. A Space Shuttle mission (SPAce Readiness Coherent Lidar Experiment, SPARCLE) is being developed at NASA/MSFC (Huntsville, AL) that will provide the first space-based test of the technique, validating the ability to maintain the severe requirements on optical alignments during launch and space operations, and removing the Doppler shift of the spacecraft velocity and Earth's rotation. Continued development will include a scientific research mission in the mid-2000's, and an operational instrument around 2010. It is anticipated that the International Space Station will be a good candidate as a platform for the scientific research mission (as an attached payload). The need for and value of wind observations, the status and objectives of the SPARCLE mission, and detailed plans for the follow-on missions, including technology development, will be discussed.

Miller, Timothy L.↗

The SeaWinds Scatterometer Antenna Subsystem on the QuikScat Spacecraft

In today's environment of "Better, Faster, Cheaper", the ability to produce reliable, flight-proven mechanisms for mission critical applications is more important than ever. Such a mechanism was produced for the QuikScat satellite. The Scatterometer Antenna Subsystem (SAS) is a spin mechanism that continuously rotates a scatterometer antenna, and includes the necessary features (rotary interfaces, drives, launch locks, etc) to allow collection of the scatterometry data that will insure mission success. This paper will discuss the evolution of the SAS from its design heritage on the GGS Polar mission to qualification on the ADEOS II satellite to being a key enabler for the rapid development of the QuikScat Satellite.

Workman, Brian J.↗

A Comparison of Measured Tone Modes for Two Low Noise Propulsion Fans

The acoustic modes for two low tip speed propulsion fans were measured to examine the effects of fan tip speed, at constant pressure ratio. A continuously rotating microphone method was used that provided the complete modal structure (circumferential and radial order) at the fundamental and second harmonic of the blade passing tone as well as most of the third harmonic modes. The fans are compared in terms of their rotor/stator interaction modal power, and total tone power. It was hoped that the lower tip speed might produce less noise. This was not the case. The higher tip speed fan, at both takeoff and cutback speeds, had lower tone and interaction levels. This could be an indication that the higher aerodynamic loading required to produce the same pressure ratio for the lower tip speed fan resulted in a greater velocity deficit in the blade wakes and thus more noise. Results consistent with expected rotor transmission effects were noted in the inlet modal structures of both fans.

Heidelberg, Laurence J.↗

Performance of an Optimized Eta Model Code on the Cray T3E and a Network of PCs

In the year 2001, NASA will launch the satellite TRIANA that will be the first Earth observing mission to provide a continuous, full disk view of the sunlit Earth. As a part of the HPCC Program at NASA GSFC, we have started a project whose objectives are to develop and implement a 3D cloud data assimilation system, by combining TRIANA measurements with model simulation, and to produce accurate statistics of global cloud coverage as an important element of the Earth's climate. For simulation of the atmosphere within this project we are using the NCEP/NOAA operational Eta model. In order to compare TRIANA and the Eta model data on approximately the same grid without significant downscaling, the Eta model will be integrated at a resolution of about 15 km. The integration domain (from -70 to +70 deg in latitude and 150 deg in longitude) will cover most of the sunlit Earth disc and will continuously rotate around the globe following TRIANA. The cloud data assimilation is supposed to run and produce 3D clouds on a near real-time basis. Such a numerical setup and integration design is very ambitious and computationally demanding. Thus, though the Eta model code has been very carefully developed and its computational efficiency has been systematically polished during the years of operational implementation at NCEP, the current MPI version may still have problems with memory and efficiency for the TRIANA simulations. Within this work, we optimize a parallel version of the Eta model code on a Cray T3E and a network of PCs (theHIVE) in order to improve its overall efficiency. Our optimization procedure consists of introducing dynamically allocated arrays to reduce the size of static memory, and optimizing on a single processor by splitting loops to limit the number of streams. All the presented results are derived using an integration domain centered at the equator, with a size of 60 x 60 deg, and with horizontal resolutions of 1/2 and 1/3 deg, respectively. In accompanying charts we report the elapsed time, the speedup and the Mflops as a function of the number of processors for the non-optimized version of the code on the T3E and theHIVE. The large amount of communication required for model integration explains its poor performance on theHIVE. Our initial implementation of the dynamic memory allocation has contributed to about 12% reduction of memory but has introduced a 3% overhead in computing time. This overhead was removed by performing loop splitting in some of the high demanding subroutines. When the Eta code is fully optimized in order to meet the memory requirement for TRIANA simulations, a non-negligeable overhead may appear that may seriously affect the efficiency of the code. To alleviate this problem, we are considering implementation of a new algorithm for the horizontal advection that is computationally less expensive, and also a new approach for marching in time.

Kouatchou, Jules↗

Duct Mode Measurements on the TFE731-60 Full Scale Engine

A continuously rotating rake with radial microphones was developed to measure the inlet and exhaust duct modes on a TFE731-60 turbofan engine. This was the first time the rotating rake technology was used on a production engine. The modal signature for the first three fan harmonics was obtained in the inlet and exhaust. Rotor-stator and rotor-strut interaction modes were measured. Total harmonic power was calculated over a range of fan speeds. Above sonic tip speed, the rotor locked mode was not strong enough to be identified, but the 'buzz-saw' noise at fan sub-harmonics was identified.

Sutliff, Daniel L.↗

Optical design, modeling, and tolerancing of a Fizeau interferometer dedicated to astrometry

Space-based interferometers dedicated to wide-angel astrometry would dramatically increase the accuracy of angular measurement fundamental to a wide range of astrophysical problems. The propsosed global Astrometric Interferometer for Astrophysics (GAIA) a continuously rotating instruments comprising two or three interferometers, will reach the 5-20 mue as level on more that 35 million objects.

Optical Design Fizeau Interferometer↗

Requirements and Technology Advances for Global Wind Measurement with a Coherent Lidar: A Shrinking Gap

Early concepts to globally measure vertical profiles of vector horizontal wind from space planned on an orbit height of 525 km, a single pulsed coherent Doppler lidar system to cover the full troposphere, and a continuously rotating telescope/scanner that mandated a vertical line of sight wind profile from each laser shot. Under these conditions system studies found that laser pulse energies of approximately 20 J at 10 Hz pulse repetition rate with a rotating telescope diameter of approximately 1.5 m was required. Further requirements to use solid state laser technology and an eyesafe wavelength led to the relatively new 2-micron solid state laser. With demonstrated pulse energies near 20 mJ at 5 Hz, and no demonstration of a rotating telescope maintaining diffraction limited performance in space, the technology gap between requirements and demonstration was formidable. Fortunately the involved scientists and engineers set out to reduce the gap, and through a combination of clever ideas and technology advances over the last 15 years, they have succeeded. This paper will detail the gap reducing factors and will present the current status.

Kavaya, Michael J.↗

ISS Solar Array Alpha Rotary Joint (SARJ) Bearing Failure and Recovery: Technical and Project Management Lessons Learned

The photovoltaic solar panels on the International Space Station (ISS) track the Sun through continuous rotating motion enabled by large bearings on the main truss called solar array alpha rotary joints (SARJs). In late 2007, shortly after installation, the starboard SARJ had become hard to turn and had to be shut down after exceeding drive current safety limits. The port SARJ, of the same design, had been working well for over 2 years. An exhaustive failure investigation ensued that included multiple extravehicular activities to collect information and samples for engineering forensics, detailed structural and thermal analyses, and a careful review of the build records. The ultimate root cause was determined to be kinematic design vulnerability coupled with inadequate lubrication, and manufacturing flaws; this was corroborated through ground tests, metallurgical studies, and modeling. A highly successful recovery plan was developed and implemented that included replacing worn and damaged components in orbit and applying space-compatible grease to improve lubrication. Beyond the technical aspects, however, lie several key programmatic lessons learned. These lessons, such as running ground tests to intentional failure to experimentally verify failure modes, are reviewed and discussed so they can be applied to future projects to avoid such problems.

DellaCorte, Christopher↗

Performance Characterization of UV Science Cameras Developed for the Chromospheric Lyman-Alpha Spectro-Polarimeter

The NASA Marshall Space Flight Center (MSFC) has developed a science camera suitable for sub-orbital missions for observations in the UV, EUV and soft X-ray. Six cameras will be built and tested for flight with the Chromospheric Lyman-Alpha Spectro-Polarimeter (CLASP), a joint National Astronomical Observatory of Japan (NAOJ) and MSFC sounding rocket mission. The goal of the CLASP mission is to observe the scattering polarization in Lyman-alpha and to detect the Hanle effect in the line core. Due to the nature of Lyman-alpha polarization in the chromosphere, strict measurement sensitivity requirements are imposed on the CLASP polarimeter and spectrograph systems; science requirements for polarization measurements of Q/I and U/I are 0.1 percent in the line core. CLASP is a dual-beam spectro- polarimeter, which uses a continuously rotating waveplate as a polarization modulator, while the waveplate motor driver outputs trigger pulses to synchronize the exposures. The CCDs are operated in frame-transfer mode; the trigger pulse initiates the frame transfer, effectively ending the ongoing exposure and starting the next. The strict requirement of 0.1 percent polarization accuracy is met by using frame-transfer cameras to maximize the duty cycle in order to minimize photon noise. Coating the e2v CCD57-10 512x512 detectors with Lumogen-E coating allows for a relatively high (30 percent) quantum efficiency at the Lyman-alpha line. The CLASP cameras were designed to operate with a gain of 2.0 +/- 0.5, less than or equal to 25 e- readout noise, less than or equal to 10 e-/second/pixel dark current, and less than 0.1percent residual non-linearity. We present the results of the performance characterization study performed on the CLASP prototype camera; system gain, dark current, read noise, and residual non-linearity.

Champey, Patrick↗

Performance Characterization of UV Science Cameras Developed for the Chromospheric Lyman-Alpha Spectro-Polarimeter (CLASP)

The NASA Marshall Space Flight Center (MSFC) has developed a science camera suitable for sub-orbital missions for observations in the UV, EUV and soft X-ray. Six cameras will be built and tested for flight with the Chromospheric Lyman-Alpha Spectro-Polarimeter (CLASP), a joint National Astronomical Observatory of Japan (NAOJ) and MSFC sounding rocket mission. The goal of the CLASP mission is to observe the scattering polarization in Lyman-alpha and to detect the Hanle effect in the line core. Due to the nature of Lyman-alpha polarization in the chromosphere, strict measurement sensitivity requirements are imposed on the CLASP polarimeter and spectrograph systems; science requirements for polarization measurements of Q/I and U/I are 0.1% in the line core. CLASP is a dual-beam spectro-polarimeter, which uses a continuously rotating waveplate as a polarization modulator, while the waveplate motor driver outputs trigger pulses to synchronize the exposures. The CCDs are operated in frame-transfer mode; the trigger pulse initiates the frame transfer, effectively ending the ongoing exposure and starting the next. The strict requirement of 0.1% polarization accuracy is met by using frame-transfer cameras to maximize the duty cycle in order to minimize photon noise. Coating the e2v CCD57-10 512x512 detectors with Lumogen-E coating allows for a relatively high (30%) quantum efficiency at the Lyman-$\alpha$ line. The CLASP cameras were designed to operate with ≤10 e- /pixel/second dark current, ≤ 25 e- read noise, a gain of 2.0 and ≤0.1% residual non-linearity. We present the results of the performance characterization study performed on the CLASP prototype camera; dark current, read noise, camera gain and residual non-linearity.

Champey, Patrick↗

Performance Characterization of UV Science Cameras Developed for the Chromospheric Lyman-Alpha Spectro-Polarimeter

The NASA Marshall Space Flight Center (MSFC) has developed a science camera suitable for sub-orbital missions for observations in the UV, EUV and soft X-ray. Six cameras will be built and tested for flight with the Chromospheric Lyman-Alpha Spectro-Polarimeter (CLASP), a joint National Astronomical Observatory of Japan (NAOJ) and MSFC sounding rocket mission. The goal of the CLASP mission is to observe the scattering polarization in Lyman-alpha and to detect the Hanle effect in the line core. Due to the nature of Lyman-alpha polarization in the chromosphere, strict measurement sensitivity requirements are imposed on the CLASP polarimeter and spectrograph systems; science requirements for polarization measurements of Q/I and U/I are 0.1 percent in the line core. CLASP is a dual-beam spectro-polarimeter, which uses a continuously rotating waveplate as a polarization modulator, while the waveplate motor driver outputs trigger pulses to synchronize the exposures. The CCDs are operated in frame-transfer mode; the trigger pulse initiates the frame transfer, effectively ending the ongoing exposure and starting the next. The strict requirement of 0.1 percent polarization accuracy is met by using frame-transfer cameras to maximize the duty cycle in order to minimize photon noise. Coating the e2v CCD57-10 512x512 detectors with Lumogen-E coating allows for a relatively high (30 percent) quantum efficiency at the Lyman-alpha line. The CLASP cameras were designed to operate with 10 e-/pixel/second dark current, 25 e- read noise, a gain of 2.0 +/- 0.5 and 1.0 percent residual non-linearity. We present the results of the performance characterization study performed on the CLASP prototype camera; dark current, read noise, camera gain and residual non-linearity.

Champey, P.↗