Search NASA⌕ Search

SEARCH · Search NASA

Results for “Control of electric power systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Hierarchical Control of Utility-Scale Solar PV Plants for Mitigation of Generation Variability and Ancillary Service Provision

This paper presents a hierarchical control system to mitigate the variability of solar photovoltaic (PV) power plant and provide ancillary services to the electric grid without the need for additional non-solar resources. With coordinated management of each inverter in the system, the control system commands the power plant to proactively curtail a small fraction of its instantaneous maximum power potential, which gives the plant enough headroom to ramp up production from the overall power plant, for a service such as regulation reserve. This control system is practical for continuously changing cloud cover conditions in partially cloudy days. A case study from a site in Hawaii with one-second resolution solar irradiance data is used to verify the efficacy of the proposed control system. The proposed control algorithm is subsequently compared with the alternative control technology from the literature, the grouping control algorithm; the results show that the proposed hierarchical control system is over 10 times more effective in reducing generator mileage to support power fluctuations from solar PV power plants.

14 SOLAR ENERGY↗

Quantitative Small-Signal Stability Analysis of Grid-Forming Inverters in Large-Scale Power Systems

In this paper, the challenges induced by the integration of inverter-based resources (IBRs) into existing power systems are discussed. Although the grid-forming (GFM) control has been used to enhance system performance in multiple sections of electric power systems (e.g., transmission and distribution systems, microgrids, among others), the coupling mechanism between GFM inverter and various types of other components in modern power systems should be clearly explored. Existing analyses mainly focus on qualitative investigations that verify the effectiveness of deploying GFM inverters for stability enhancement. A holistic system-level quantitative analysis is still missing to verify the detailed benefits of GFM inverters and their interactions with other generation units (e.g., synchronous generators [SGs], conventional grid-following [GFL] inverters, synchronous condensers, among others). To fill in the technical gaps, a holistic small-signal model of the entire system with both rotating generation units and IBRs is established along with the customized power flow analysis for varying steady-state operating points. Further, a quantitative method is proposed to identify the impacts of GFM inverters on system performance with an emphasis on a quantifiable stability margin and a complete modal analysis at the system level. Finally, a realistic test system is used to verify the proposed approach.

grid-following↗

Enhancing Responsiveness and Resilience with Distributed Applications in the Grid

A number of trends are increasing the variability in electric power systems resulting in a need for new approaches in control. The increased variability is originating from distributed energy resources and an increasing demand for personalized energy choice from customers grid-edge. Electricity distribution systems continue to incorporate increasing numbers of intelligent end devices, automated switchgear, and sensing and measurement devices which are providing more visibility and control at the grid-edge. Traditional distribution system planning and operations techniques must evolve to meet the new complexity while continuing to deliver safe, reliable, and cost-effective energy. New technologies are enabling new capabilities at the grid-edge to respond to these needs. Distributed applications can deploy intelligence across the distribution grid with peer-to-peer communications and a shared data context for their local environment. These applications can cooperate with each other to respond quickly to changing grid conditions. This enables a layered coordination framework spanning the centralized Advanced Distribution Management System functions with wide area visibility to these new distributed applications running at intelligent devices and meters throughout the distribution system. This paper describes an open-architecture, open-source system approach for commercial scale integration of devices and intelligence at the grid-edge.

Ogle, James P.↗

Advanced Power Electronics and Electric Machines

The advanced power electronics and electric machines (APEEM) research group at the National Renewable Energy Laboratory (NREL) has developed world-class experimental and modeling capabilities for designing and evaluating efficient and reliable power electronics and electric machines thermal management systems. They also design, fabricate and characterize advanced power electronics packaging, and are developing state-of-health monitoring techniques. These researchers deliver safe, reliable, high performing, power-dense components that allow seamless integration between renewable energy sources, electric transportation, and the grid, helping to make widespread electric vehicle (EV) adoption and greenhouse gas emissions reduction more feasible. This document outlines the group's major capabilities in the areas of power electronics; module development and characterization; thermal modeling and management; thermomechanical reliability analysis of devices, modules, inverters/converters, and electric machines; physics-of-failure-based reliability analysis; and microelectronics. It also overviews the group's state-of-the-art equipment for fluid-based thermal management; thermal measurement & characterization; thermomechanical reliability analysis; micro- and power electronics measurement & characterization; and prototype fabrication, as well as the group's world-class modeling and simulation capabilities.

advanced gate drivers↗

Sequential versus Simultaneous Aging of EPDM Nuclear Cable Insulation Subjected to Elevated Temperature and Gamma Radiation

Electrical cables are integral to power, control, and instrumentation systems within nuclear power plants (NPPs). Exposure of cable systems within nuclear containment to elevated temperatures and gamma radiation during decades-long operation of NPPs can lead to degradation of cable polymeric insulation. Prediction of nuclear cable insulation degradation is complicated as thermal and radiation stress are not additive. In this work, we explore the relative effects of simultaneous and sequential thermal and gamma irradiation on the aging of ethylene-propylene-diene (EPDM) elastomer insulation to better understand realistic scenarios of cable insulation degradation. Cable insulation samples of EPDM were subjected to up to 320 kGy of gamma radiation at a dose rate of 300 Gy/hr in two heating scenarios: (1) simultaneously aged samples were heated at 150°C during irradiation and (2) sequentially aged samples were heated at 150°C for designated durations followed by corresponding periods of irradiation at ambient temperature. The mass, tensile elongation at break, and carbonyl index were assessed to quantify aging of the polymers. The simultaneous aging scenario was found to the more severe of the two for EPDM insulation degradation.

ethylene-propylene-diene elastomer, EPDM, nuclear ↗

A Model-Free Voltage Control Approach to Mitigate Motor Stalling and FIDVR for Smart Grids

Electric power networks are large and highly nonlinear dynamical systems that present unique challenges to control design. Though there is a large number of dynamic models for power system stability and control, many models are only useful with right assumptions and wrong for other tasks. Moreover, the dynamic behavior of the grid is increasingly complex under the banner of smart grids. These lead to the difficulty of developing appropriate dynamic modeling, and thus an efficient control strategy. To avoid such modeling challenges, here we present a novel dynamic voltage control strategy based on a model-free control (MFC) approach, requiring no modeling procedure. In particular, it focuses on fault-induced delayed voltage recovery (FIDVR) events, which require complex and accurate dynamic load models to replicate such events. This work utilizes MFC as an online controller to achieve the desired voltage stability under the FIDVR event. The proposed MFC strategy allows simple implementation and low computational cost for efficient mitigation of FIDVR. For benchmarking, a reasonably accurate dynamic performance model is explored. Simulation results with the IEEE 57 bus test network demonstrate the enhanced dynamic voltage profile for load buses having induction motors with the support of reactive power resources.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Safe Deep Reinforcement Learning for Active Distribution System Model Predictive Control with EVs and DERs

The temporal and spatial mismatch between PV generation and electric vehicle (EV) charging and discharging may cause voltage violations in active distribution networks. Despite the widespread use of deep reinforcement learning (DRL) in power system optimization and control, it lacks guarantees on constraint satisfaction during both training and deployment. This paper proposes a Lagrangian-based safe DRL approach for model predictive control (MPC) of active distribution systems with large-scale integration of PVs, EVs, and energy storage systems (ESSs). A Transformer-LSTM time-series model is proposed to forecast EV charging demand, which is then formulated as a constraint to ensure charging requirements are met. Using this prediction, a Lagrangian-based safe soft actor-critic (SAC) framework is developed for real-time control in a three-phase unbalanced distribution system, enforcing voltage safety constraints while optimizing the cumulative net reward. By integrating the forecasting model with multi-period constraints, the proposed framework jointly coordinates PV systems, EV charging and discharging, and ESS scheduling within the MPC horizon. Numerical experiments on a modified IEEE 123-bus system with real-world data show that, under a high PV penetration scenario, the proposed method increases the net reward by 30.74% and reduces average voltage violations from 0.0011 p.u. to 0.0002 p.u. compared with standard SAC. Compared with the optimal power flow (OPF) approach, it achieves similar voltage security while yielding lower line losses. It also maintains real-time control capability, reducing operation latency to 53.21 ms per 15-minute control interval. The proposed method remains effective under varying PV/EV penetrations and load conditions.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Incorporating Valve Switching Losses Into a Static Optimal Control Algorithm for the Hybrid Hydraulic-Electric Architecture (HHEA)

The Hybrid Hydraulic-Electric Architecture (HHEA) has, in recent years, been proposed as an energy efficient alternative to conventional load-sensing architectures in mobile machines such as excavators and wheel-loaders. HHEA leverages the advantages of hydraulic power and electric power to eliminate throttling valves while also improving the energy and control performance of the system. The architecture utilizes a set of common pressure rails to provide a majority of power and and a small electric motor driven pump to modulate this power to meet the exact demand. Previous work has developed a computationally efficient Lagrange Multiplier approach for determining the optimal pressure rail selections that minimizes the energy losses in the system. The static model used considers only the energy use for each pressure rail selection but not the losses associated with the valves during the transition. This paper presents an approach to include the switching losses in the model and in the optimization procedure. To capture the switching losses, switching events between different rails and at various input and output flow rates were simulated with consideration of valve spool dynamics. A parameterized model that summarizes the losses is then obtained, allowing switching losses to be added to the previous energy analysis. The performance of the switching loss model was compared with reference data obtained from a high-fidelity simulation model. To incorporate the switching losses into optimal control algorithm, an efficient dynamic programming approach that prevents frequent switching is adopted in place of the Lagrange multiplier approach. The overall effect of switching losses on the energy consumption and optimal control decisions is presented. In general, switching losses contribute to about 9–10% of input energy.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Mining Smart Meter Data to Enhance Distribution Grid Observability for Behind-the-Meter Load Control: Significantly improving system situational awareness and providing valuable insights

Distributed Energy Resources (DERs) are playing an increasingly important role in power systems. In 2023, five categories of DERs-distributed solar, electric vehicles (EVs), energy storage, residential smart thermostats, and small-scale combined heat and power-are expected to contribute about 104 GW to the U.S. summer peak (see GTM, 2018). With the increasing integration of DERs in power distribution systems, distributed load control is imperative to smooth the fluctuations that they introduce. However, a main challenge is that distribution systems lack systematic situational awareness because of their limited sensors. Furthermore, most customer-level behind-the-meter (BTM) DERs, such as rooftop photovoltaics (PVs), are being integrated into distribution systems, which complicates the system monitoring and control. Furthermore, enhanced electric grid monitoring is needed to promote renewable integration while ensuring reliability, but current approaches rely on expensive sensors.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Peak load reduction and load shaping in HVAC and refrigeration systems in commercial buildings by using a novel lightweight dynamic priority-based control strategy

Reducing peak power demand in a building can reduce electricity expenses for the building owner and contribute to the efficiency and reliability of the electrical power grid. For the building owner, reduced expenses come from the reduction or elimination of peak power charges on electricity bills. For the power system operator, reducing peak power demand leads to a more predictable load profile and reduces stress on the electric grid system. Herein we present a computationally inexpensive, dynamic, and retrofit-deployable control strategy to effect peak load reduction and load shaping. The effectiveness of the control strategy is examined in a simulation with 80 air-conditioning units and 40 refrigeration units. The results show that a peak demand reduction of 60 kW can be achieved relative to peak demand in a typical set point–based approach. The proposed strategy was deployed in a gymnasium building with four rooftop HVAC units, where it showed over 15% peak demand (kW) reduction savings while maintaining or lowering energy consumption (in kilowatt-hours) relative to the set point–based thermostat controls.

24 POWER TRANSMISSION AND DISTRIBUTION↗

High power pulse systems for surface processing

A high-power pulsed surface processing system includes insulated-gate bipolar transistors (IGBT) to replicate desirable pulse structures with high precision, at low cost, and with high reliability within a single system. The pulsed surface processing system includes a power supply, an anode and a cathode, a dual gate driver supplying power to one or more IGBT gates, and one or more capacitor banks. Pulse formation software controls the timing and duration of electrical pulses to the electrodes. A freewheeling diode protects the system from an abrupt reduction of current in the circuit. The high-power pulsed surface processing system may be used to control versatile and complex pulse structures while with precise control of instantaneous pulse powers, pulse timing, and process control. The inclusion of dual gate drivers also offers the ability for multiple pulsers to be created and “slaved” together for a wide variety of custom processes.

Tian, Hui↗

Control and Management of Multiple Converters in a Residential Smart Grid

Power electronic systems are becoming a staple building block for electric grid networks. However, these systems have been largely designed to grid integrate in ad hoc configurations with little or no coordination of control. This work proposes a central controller and power electronic system hardware and software design for a residential system (photovoltaic, energy storage and residential building). This system supports auto-integration, plug and play capabilities, and optimal energy management to meet different use cases. Modelling and multi-day testing of the system have been conducted in a controller hardware-in-the-loop (C-HIL) testbed. Multiple use cases and pricing options have been considered as part of the simulation and testing. Results are presented of these systems as a proof of principle.

Starke, Michael↗

Fast, Controllable, and Modular Solid-State Circuit Breaker Design for Battery Management Systems

Electric power grid is experiencing a growing number of distributed and inertia-free generation resources. To facilitate the growing generation and load demands, and ensure stable operation, energy storage systems, especially behind-themeter-storage (BTMS), have emerged as a potential candidate. BTMS plays a vital role in the grid storage sector and supports high power charging for EVs. However, the potential of thermal runaway and associated safety concerns in the batteries can hamper their widespread adoption. In this work, we provide a solution for a fast and controllable discharge of a cell that was identified as a stressful/faulty, in the battery pack, and fast circuit breaking leveraging the Solid-State Circuit Breaker (SSCB) technology which provides active control over the cell connection as opposed to conventional passive solutions. Testing on the simulation platform successfully validated the concept, demonstrating its efficacy. Controlled discharge testing with 20Ah LiFePO4 Lithium Iron Phosphate (LFP) cells from 1C-10C current rate on the hardware prototype corroborated simulation results, demonstrating design feasibility and providing essential data for its performance and thermal characteristics, while also revealing limitations that inform areas for further optimization.

33 ADVANCED PROPULSION SYSTEMS↗

Model based co-simulation platform for integrated building system control and design optimization

Both steady-state and dynamic simulations have been widely used by HVAC&R industry to support product/equipment development for decades. Steady-state simulation focuses on the system mass, energy and momentum balance of an equilibrium state. It is based on high-fidelity components models, and thus is suitable for system and component design optimization. Dynamic simulation studies the system transient response and is generally used for controls development and verification. It usually does not require rigorous component models of high accuracy because 1) the commonly used PID control is feedback control whose control performance evaluation doesn’t require high fidelity system/plant model; 2) high-fidelity dynamic model significantly increases the number of equations and variables and creates tremendous challenge for math solver. For supervisory control, transactive control or optimization of an integrated building system, the HVAC&R equipment is often one of the sub-components to be controlled. High-fidelity equipment models are required for accurately evaluating control strategies. In addition, building equipment manufacturers have developed a lot of high-fidelity steady-state equipment/component models per their expertise. Thus, a platform that can integrate OEM high-fidelity steady-state model with dynamic building simulation and/or electric power system & grid simulation to support the development and verification of supervisory control for integrated building systems is necessary. In this study, ORNL’s heat pump design tool (HPDM) is utilized to develop a co-simulation platform for supervisory control and optimization in integrated building systems. It is based on a model that integrates high-fidelity steady-state simulation equipment models with dynamic building simulation. A practical case of using the proposed co-simulation platform to develop and evaluate the supervisory control and optimization is presented and discussed.

Sun, Jian↗

Multiobjective Optimal Controlled Variable Selection for a Gas Turbine–Solid Oxide Fuel Cell System Using a Multiagent Optimization Platform

Hybrid gas turbine–fuel cell systems have immense potential for high efficiency in electrical power generation with cleaner emissions compared with fossil-fueled power generation. We report a systematic controlled variable (CV) selection method is deployed for a hybrid gas turbine–fuel cell system in the HyPer (hybrid performance) facility at the U.S. Department of Energy’s National Energy Technology Laboratory (NETL) for maximizing its economic and control performance. A three-stage approach is used for the CV selection comprising a priori analysis, multiobjective optimization, and a posteriori analysis. The a priori analysis helps to screen off several candidate CVs, thus reducing the size of the combinatorial optimization problem for multiobjective CV selection. For optimal CV selection, a transfer function model of the HyPer facility is identified. By considering several candidate models, the final transfer function model is selected using Akaike’s Final Prediction Error criterion. Experimental data from the HyPer facility are used to estimate the noise in the measurement data. For solving the combinatorial multiobjective optimization problem for CV selection, a multiagent optimization platform comprising simulated annealing, genetic algorithm, and efficient ant colony optimization algorithms is used. Pareto-optimal CV sets exhibit a high trade-off between the economic and control objective. The a posteriori analysis is undertaken for several top Pareto-optimal CV sets. An optimal CV set is selected that shows the best compromise between process economics and controllability under both nominal and off-design conditions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Optimal Distribution System Voltage Regulation using State Estimation and DER Grid-Support Functions

Increasing solar energy penetrations may create challenges for distribution system operations because production variability can lead to large voltage deviations or protection system miscoordination. Instituting advanced management systems on distribution systems is one promising method for combating these challenges by intelligently controlling distribution assets to regulate voltage and ensure protection safety margins. While it is generally not the case today, greater deployment of power system sensors and interoperable distributed energy resources (DER)e.g., photovoltaic (PV) inverters, energy storage systems (ESS), electric vehicles (EVs)will enable situational awareness, control, and optimization of distribution systems. In this work, a control system was created which measures power system parameters to estimate the status of a feeder, forecasts the distribution state over a short-term horizon, and issues optimal set point commands to distribution-connected equipment to regulate voltage and protect the system. This two-year project integrated multiple research innovations into a management system designed to safely allow PV penetrations of 50% or greater. The integrated software was demonstrated through extensive real-time (RT) and power hardware-in-the-loop studies and a field demonstration on a live power system with a 684 kVA PV system.

24 POWER TRANSMISSION AND DISTRIBUTION↗

EMOS (Energy Management Optimization System) [SWR-21-46]

EMOS software performs a real-time hierarchal optimal control for energy systems like multi-port electric vehicles charging site with distributed energy resources (DERs) and energy storage systems (ESSs). It gathers information in real-time from electric vehicles, power grid, and DERs, solves a multi-objective energy management optimization problem, and output setpoint for chargers, ESS converters, DERs converters, and grid converters. The software incorporates a novel integration of two control tasks: a) An Energy Management Optimization (EMO), which is the brain of EMOS controller that gathers information in real-time from EVs [e.g., battery size, state-of-charge (SOC), desired SOC, and charge acceptance curve], grid (e.g., electricity price, allowed feeder capacity, ramp rate limit, and reactive power), and DERs (e.g., prediction for solar generation for PV systems). It solves a control optimization problem in real-time to find optimal setpoint for ESSs power dispatch, EVs charging rate, and grid inverters. The objectives are to (1) minimize the charging cost considering grid energy, demand charges, and battery energy, (2) minimize charging time to meet fast charging criterion, (3) keep high energy level on ESSs at the end of an operating period, while satisfying constraints related to grid, EVs, and power converters. b) Real-Time Energy Management System (RT-EMS) is a rule-based algorithm that has faster response than EMO. It receives optimal setpoint from EMO and actual measurements from the system and modify the setpoint to compensate for any fast disturbance in the system, until a new optimum solution is received. Fast disturbances may include vehicle connect/disconnect, unpredicted variation in DERs profiles, variation in grid voltage, errors in PV generation prediction, and others. In addition, RT-EMS regulates voltage at point of common coupling (PCC) by managing reactive power of grid converters.

Mohamed, Ahmed↗

Development of a Multi-Robot System for Autonomous Inspection of Nuclear Waste Tank Pits

This paper introduces the overall design plan, development timeline, and preliminary progress of the Autonomous Pit Exploration System project. This project aims to develop an advanced multi-robot system for the efficient inspection of nuclear waste-storage tank pits. The project is structured into three phases: Phase 1 involves data collection and interface definition in collaboration with Hanford Site experts and university partners, focusing on tank riser geometry and hardware solutions. Phase 2 includes the selection of sensors and robot components, detailed mechanical design, and prototyping. Phase 3 integrates all components into a cohesive system managed by a master control package which also incorporates digital twin and surrogate models, and culminates in comprehensive testing and validation at a simulated tank pit at the Idaho National Laboratory. Additionally, the system’s communication design ensures coordinated operation through shared data, power, and control signals. For transportation and deployment, an electric vehicle (EV) is chosen to support the system for a full 10 h shift with better regulatory compliance for field deployment. A telescopic arm design is selected for its simple configuration and superior reach capability and controllability. Preliminary testing utilizes an educational robot to demonstrate the feasibility of splitting computational tasks between edge and cloud computers. Successful simultaneous localization and mapping (SLAM) tasks validate our distributed computing approach. More design considerations are also discussed, including radiation hardness assurance, SLAM performance, software transferability, and digital twinning strategies.

Nuclear waste management↗