Search NASA⌕ Search

SEARCH · Search NASA

Results for “Cooling system efficiency”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

COGIHTO: Comprehensive Geothermal Integrated HVAC Retrofits in Disadvantaged Communities

Geothermal heating and cooling (GHC) systems offer one of the most efficient approaches to provide space conditioning and water heating in buildings. Due to the relatively stable temperature of the ground year-round, these systems can provide an efficient solution to decarbonize heating systems. Yet this technology has faced limited market adoption due to its high first cost. This project seeks to address this barrier by designing a community GHC system at a public housing development in New York, taking advantage of load diversity (in terms of the timing and amount of heating / cooling used per person) that a larger community offers to reduce the size and thus first cost of a GHC system. Project success would result in societal benefit from reduced energy and fossil fuel use, reduced local emissions, and improved comfort, which would positively impact the health and well-being this community. This report presents the findings from Phase 1 project supported by the Department of Energy’s Geothermal Technologies Office and includes the technical design of a GHC at a public housing development in New York. To support the success of a potential deployment of a GHC system, the team conducted community engagement and prepared an assessment of the local workforce needs. The project team, led by EPRI, considered a subset of NYCHA housing developments that were previously identified by NYCHA as suitable for GHC retrofits. This report presents the site selection criteria the team developed and the overall score assigned to each of the eight developments considered. One site was selected for focus of the technical design: Stapleton Houses in Staten Island, a mid-size development with roughly 700 apartments across 6 buildings. The site has an existing hot water hydronic loop served by natural gas boilers for space heating and water heating. The technical design partner assessed baseline energy consumption at the site and established thermal models of the apartment buildings to assist in the design. The team considered several GHC system configurations and selected a hybrid geothermal design fed from water-source heat pumps with auxiliary gas boilers in a central plant. This design best leveraged the existing site configuration and minimized costs due to additional electrical infrastructure upgrades. The report also details the feedback received from community engagement efforts and the findings from the workforce needs assessment and workforce transition plan. Members of the site maintenance staff and the resident advisory council were interviewed for their input and feedback about both the site’s existing heating/cooling infrastructure and how a construction project would impact resident life. This feedback was taken into consideration when completing the geothermal system design. Research was conducted into existing workforce development opportunities available to NYCHA residents. A workforce development plan was established using information from NYCHA’s resident economic empowerment and sustainability group, along with training material and curriculum from the International Ground Source Heat Pump Association (IGSHPA).

15 GEOTHERMAL ENERGY↗

Numerical Simulations of Cryogenic Hydrogen Cooling in Vortex Tubes with Smooth Transitions

Improving efficiency of hydrogen cooling in cryogenic conditions is important for the wider applications of hydrogen energy systems. The approach investigated in this study is based on a Ranque-Hilsch vortex tube (RHVT) that generates temperature separation in a working fluid. The simplicity of RHVT is also a valuable characteristic for cryogenic systems. In the present work, novel shapes of RHVT are computationally investigated with the goal to raise efficiency of the cooling process. Specifically, a smooth transition is arranged between a vortex chamber, where compressed gas is injected, and the main tube with two exit ports at the tube ends. Flow simulations have been carried out using STAR-CCM+ software with the real-gas Redlich-Kwong model for hydrogen at temperatures near 70 K. It is determined that a vortex tube with a smooth transition of moderate size manifests about 7% improvement of the cooling efficiency when compared vortex tubes that use traditional vortex chambers with stepped transitions and a no-chamber setup with direct gas injection.

08 HYDROGEN↗

Surface Merging Technique to Design GA-Optimized Heat Sinks

High-power density inverters require efficient and small heat dissipation systems. For liquid cooling systems, an effective heat sink design is important to enable higher heat transfer and keep the pressure drop within reasonable limits. A heat sink geometry generated from an extruded, 1D fast Fourier transform can achieve more even temperature distribution and improved heat transfer than a conventional heat sink. Building on this concept, this paper proposes a new heat sink geometry creation algorithm. Instead of one plane profile being extruded, multiple plane profiles, each created from the fast Fourier transform method, are subsequently merged by smooth surfaces along the flow direction of the heat sink. Thus, a 3D heat sink geometry is created that enables 3D coolant flow and efficient heat transfer. The volume of this design was reduced by 50% compared with pin fin heat sinks. Compared with extruded 1D fast Fourier transform heat sinks, the proposed design showed an approximately 5% device temperature reduction and a 20% pressure drop reduction.

Barua, Himel↗

Pool boiling heat transfer evaluation of next-generation dielectric fluid: Opteon™ 2P50

The growing use of artificial intelligence has led to heavy thermal loads and high heat dissipation rates in data centers. Conventional air-cooled technologies are not able to fulfill these requirements. To overcome these challenges, two-phase immersion cooling (2PIC) has emerged as one of the leading technologies for high power-density chips. 2PIC increases the heat dissipation rate and efficiency of the system while reducing the footprint of the cooling equipment. A fluid with adequate dielectric properties, a suitable normal boiling temperature to maintain chip temperatures, and good material compatibility, is desired for 2PIC system. In this study, the pool boiling heat transfer of a new developmental dielectric fluid, Opteon™ 2P50, was experimentally investigated. The heat transfer coefficients at various heat fluxes (20–150 kW/m 2 ) and the critical heat flux were measured using a smooth aluminum surface. Compared with HFE-7100, Opteon™ 2P50 shows higher heat transfer coefficient (up to 59% higher) and a slightly lower value of critical heat flux (around 5.9% lower). The modified Cooper correlation with the optimized leading constant resulted in reliable prediction accuracy with a 5.3% mean absolute error percentage. Overall, these results indicate that the new dielectric fluid provides similar thermal performance to some legacy fluids.

2P50↗

Application Potential of a Dew-Point Cooling Tower in Selected Energy Intensive Applications in Temperate Climate

In the article, the application potential of the dew-point cooling tower (DPCT) in selected energy-intensive applications in temperate climates was analyzed and discussed. The applications selected for analysis are power generation with natural gas turbines and chilled water air conditioning systems. The study is based on a mathematical model derived from a modified ε-NTU model. The model was validated against experimental results and showed satisfactory agreement with the experimental data. DPCT was compared with a typical cooling tower limited by the wet-bulb temperature (wet-bulb cooling tower, WBCT). The simulation results showed that DPCT is able to provide significant energy savings in energy-intensive applications; therefore, its application potential in temperate climates can be considered justified. In the case of gas turbines, DPCT was able to generate 2 to 10 percentage points more capacity than operating on outdoor air and 1.8 to 5 percentage points more than operating with WBCT. In the case of air conditioning systems, the system equipped with DPCT achieved EERs (energy efficiency ratios) higher by 1 to 7.2 compared to dry cooling and by 0.3 to 5.1 compared to systems equipped with WBCT. The annual energy savings obtained by the system with DPCT were 14.7 MWh compared to WBCT and 30 MWh compared to dry cooling.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Comminty Geothermal: Planning and Design of a Heating and Cooling System in Framingham, Massachusetts

These reports, plans, and drawings review the achievements of Home Energy Efficiency Team (HEET) and its partners to plan and design a network of interconnected ground-source heat pump systems, or geothermal network, in an area encompassing multiple environmental justice (EJ) neighborhoods in the City of Framingham, MA. The materials provided in this dataset include, a) stakeholder and design best practices, b) study on optimal method to interconnect geothermal loops, c) guidelines for monitoring and metering, d) operations and maintenance plans, e) permitting guidelines and f) 10-day driller tutorial curriculum. These materials can guide the efficient and ethical design of future geothermal networks nationwide. The capacity of the system is estimated at 217 tons and is designed to provide 100% of heating and cooling needs for the buildings connected to the loop. In this project, 80 boreholes are used as the main thermal resources, the distribution system (or loop) consists of 0.61 miles of an 8-inch single-pipe at ambient temperature, with the capacity to connect 44 buildings, including 13 apartment buildings from the Framingham Housing Authority, one transitional home, one school building and 29 single family homes. While Framingham already has a geothermal network loop that is currently in the commissioning stage, our proposed project is unique because it is the first utility-led expansion loop (2nd loop) project that will connect to an adjacent existing geothermal loop (1st loop) in a pre-existing neighborhood. Both the 1st and 2nd loops are being installed, owned and operated by Eversource Energy, the utility Deployment Partner.

15 GEOTHERMAL ENERGY↗

Balancing performance of active magnetic regenerators: a comprehensive experimental study of aspect ratio, particle size, and operating conditions

Abstract Effective and, at the same time, efficient active magnetic regenerator (AMR) performance requires balanced geometry and operating conditions. Here the influence of regenerator shape, magnetocaloric material size, operating frequency, and utilization on the performance of gadolinium packed-particle bed AMRs is demonstrated experimentally. Various metrics are applied to assess effectiveness and efficiency. Observed temperature spans and cooling powers across a wide range of operating conditions are used to evaluate system performance and estimate exergetic cooling power and exergetic power quotient. A new metric combining exergetic cooling power and pump power provides an estimate of the maximum achievable second law efficiency. Five regenerator geometries with equal volumes and the aspect ratio from 1.0 to 3.8, and four different ranges of Gd spherical particles between 182 and 354 µ m, are investigated. Improvements in system performance are demonstrated by a boost in specific cooling power of gadolinium from 0.85 to 1.16 W g −1 and maximum temperature span from 8.9 to 15.1 K. The optimum exergetic cooling power is observed for 1.37 utilization and 3 Hz operating frequency, exergetic power quotient exhibits a maximum at the same utilization but at 2 Hz frequency, while the highest efficiency is recorded at 1 Hz and utilization of 0.5, demonstrating that multiple performance metrics must be balanced to achieve regenerator design meeting all performance targets.

42 ENGINEERING↗

Methods development towards automated, physics-informed, quantitative quality control of TRISO-SiC

Tristructural-isotropic (TRISO) fuel particles have been developed as a high-performance fuel for use in high-temperature gas-cooled reactor (HTGR) systems due to their high efficiency and stability under both normal and off-normal conditions. Broader deployment of this technology in advanced nuclear applications may benefit from quantitative quality assurance and quality control (QA/QC) methods that directly link TRISO properties to downstream performance. A key TRISO property is the SiC layer microstructure, which influences fission product retention during irradiation. However, existing QA/QC for the TRISO-SiC microstructure comprises only a qualitative visual inspection; therefore, there is a clear opportunity for the development of quantitative methods for TRISO QA/QC. Here, to this end, previous work has demonstrated an image processing approach to grain boundary (GB) identification and subsequent extraction of microstructural metrics; however, extensive twinning within the SiC layer complicates such analyses because twin GBs significantly influence microstructural metrics but are not expected to contribute to fission product transport. This study presents the initial development, training, and testing of an ML-based image segmentation algorithm designed to identify and remove twin GBs from standard backscattered electron micrographs, providing an industrially applicable, quantitative, and physically meaningful QA/QC approach for the TRISO-SiC microstructure. Although pixel-wise performance metrics for the twin predictions are low, the change in grain area and the number of GB pixels after twin removal predicted by the ML workflow are within 1% of the true values calculated using crystallographic data. This suggests that the model is well capable of predicting overall twin boundary structures and grain morphology, and continued advancement of this approach could enable automated, scalable, and physics-informed QA/QC for TRISO-SiC microstructures, supporting the reliable qualification of coated particle fuels for next-generation reactor systems.

Computer vision↗

Optimized pulsed sideband cooling and enhanced thermometry of trapped ions

Resolved sideband cooling is a standard technique for cooling trapped ions below the Doppler limit to near their motional ground state. Yet the most common methods for sideband cooling implicitly rely on low Doppler-cooled temperatures and tightly confined ions and they cannot be optimized for different experimental conditions. Here we introduce a framework which calculates the fastest possible pulsed sideband cooling sequence for a given number of pulses and set of experimental parameters and we verify its improvement compared to traditional methods using a trapped 171 Yb + ion. After extensive cooling, we find that the ion motional distribution is distinctly nonthermal and thus not amenable to standard thermometry techniques. We therefore develop and experimentally validate an improved method to measure ion temperatures after sideband cooling. These techniques will enable more efficient cooling and thermometry within trapped-ion systems, especially those with high initial temperatures or spatially extended ion wave packets.

74 ATOMIC AND MOLECULAR PHYSICS↗

Soft Matter Thermal and Mechnical Devices

The participant company, Treau, makes homes and buildings more comfortable with quiet, energy efficient, and easy to install heating and cooling systems. They entered the Cyclotron Road program with an idea for a heat exchanger and compressor and a general idea that the building heating and cooling sector was the best first target market. While at Cyclotron Road, they used the Cyclotron Road program staff and Berkeley Lab expertise to better understand the needs of the heating and cooling equipment market. This was critical to understand who the end customer was, and what features were needed in this market. They were then able to conduct product development with this target market/customer in mind. The Cyclotron Road program was also critical in building a manufacturing and scale-up plan that allowed the participant to build a credible growth and fundraising strategy. By the end of the program, the participant had a working prototype testing at Berkeley Lab’s HVAC testing facilities.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Risk-Informed ATF and FLEX Analysis for an Enhanced Resilient BWR Under Design-Basis and Beyond-Design-Basis Accidents

This report documents the activities performed by the Idaho National Laboratory (INL) during fiscal year (FY) 2020 for the U.S. Department of Energy (DOE) Light Water Reactor Sustainability (LWRS) Program, Risk-Informed System Analysis (RISA) Pathway, Enhanced Resilient Plant (ERP) Systems research. The purpose of the RISA Pathway research and development is to support plant owner-operator decisions with the aim to improve the economics, reliability, and maintain the high levels of safety of current nuclear power plants over periods of extended plant operations. The concept of ERP refers to the combinations of accident-tolerant fuel (ATF), optimal use of diverse and flexible coping strategy (FLEX), enhancements to plant components and systems, and the incorporation of augmented or new passive cooling systems, as well as improved fuel cycle efficiency. The objective of the ERP research effort is to use the RISA methods and toolkit in industry applications, including methods development and early demonstration of technologies, in order to enhance existing reactors’ safety features (both active and passive) and to substantially reduce operating costs through risk-informed approaches to plant design modifications to the plant and their characterization. One main focus of the FY 2020 efforts documented in this report was to extend the analyses conducted in FYs 2018 and 2019 for a pressurized water reactor (PWR) to a boiling water reactor (BWR). The same analysis process, risk analysis approaches, and analysis tools as in the previous work for PWR were used for a generic BWR with near-term ATF cladding (i.e., Iron-Chromium-Aluminum [FeCrAl] cladding and Chromium [Cr]-coated cladding) designs under the postulated station blackout (SBO) and medium loss-of-coolant (MLOCA) accident scenarios. In addition, a FLEX model was developed and incorporated into a generic BWR probabilistic risk assessment (PRA) model using the INL-developed software tool, Systems Analysis Programs for Hands-on Integrated Reliability Evaluations (SAPHIRE), to assess the risk impact from FLEX. The other main focus of the FY 2020 efforts was to advance analysis methods, including developing dynamic approach for FLEX human reliability analysis (HRA) using the INL-developed software tool, Event Modeling Risk Assessment using Linked Diagrams (EMRALD), as well as developing a multicriterion benefit evaluation (MCBE) method for evaluating costs and benefits of safety enhancements in nuclear power plants (NPPs). As a case study, the MCBE method was applied to evaluate the costs and benefits brought by FLEX implementation.

99 GENERAL AND MISCELLANEOUS↗

Implementation Plan for Combined Heat and Power Systems VOLTTRON Controller: Performance Monitoring and Real-Time Commissioning Algorithm Verification

Building-integrated cooling, heating, and power (CHP) systems are more efficient than conventional systems at providing local power and thermal energy, and favorable fuel prices are bound to spur their increased adoption. However, to realize the full benefit of the CHP systems, we must ensure persistence of energy efficient operations. Much of the inefficiency in the current building operations can be eliminated by use of automated performance monitoring (PM), real-time commissioning verification (CxV) and automated fault detection and diagnostic (AFDD) tools. Automation can help system operators make intelligent decisions. Remote and continuous monitoring of system conditions and performance will enable better management and integration of CHP with existing building systems. Continuous PM, real-time CxV, and AFDD could alleviate burdens for operations staff, enhance operations and maintenance (O&M), and improve reliability of building and CHP systems. To address the O&M challenges and to provide a means to maximize the rate-of-return of building-integrated CHP systems, the Building Technologies Office (BTO) within the U.S. Department of Energy’s (DOE’s) Office of Energy Efficiency and Renewable Energy (EERE) initiated a project to design, develop, and field test a VOLTTRON™-based supervisory controller and associated open-source algorithms. These algorithms will ensure real-time optimal operation of a building-integrated CHP system, support electric grid reliability, and lead to achieving the goal of clean, efficient, reliable, and affordable next-generation integrated energy system. Previous report listed the components for which PM, real-time CxV, and AFDD algorithms will be developed, how the algorithms will be tested, and the metrics that will be used to validate the algorithms and their ease of deployment. Deployment of these algorithms in the field will result in a reduction in energy consumption of between 10% and 20% (for both CHP and conventional building systems). This report builds upon the previous report by detailing the process by which PNNL will implement performance monitoring and real-time commissioning algorithms for CHP systems in conjunction with the use of the VOLTTRON CHP economic dispatch agent in host facilities.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Energy efficient data center liquid cooling with geothermal enhancement

A data center cooling system is operated in a first mode, has an indoor portion wherein heat is absorbed from components in the data center by a heat transfer fluid, and has an outdoor heat exchanger portion and a geothermal heat exchanger portion. The first mode includes ambient air cooling of the heat transfer fluid in the outdoor heat exchanger portion and/or geothermal cooling of the heat transfer fluid in the geothermal heat exchanger portion. Based on an appropriate metric, a determination is made that a switch should be made from the first mode to a second, different, mode; and, responsive thereto, the data center cooling system is switched to the second mode. The second mode includes at least another of ambient air cooling of the heat transfer fluid in the outdoor heat exchanger portion and geothermal cooling of the heat transfer fluid in the geothermal heat exchanger portion.

15 GEOTHERMAL ENERGY↗

Energy efficient data center liquid cooling with geothermal enhancement

A data center cooling system is operated in a first mode, has an indoor portion wherein heat is absorbed from components in the data center by a heat transfer fluid, and has an outdoor heat exchanger portion and a geothermal heat exchanger portion. The first mode includes ambient air cooling of the heat transfer fluid in the outdoor heat exchanger portion and/or geothermal cooling of the heat transfer fluid in the geothermal heat exchanger portion. Based on an appropriate metric, a determination is made that a switch should be made from the first mode to a second, different, mode; and, responsive thereto, the data center cooling system is switched to the second mode. The second mode includes at least another of ambient air cooling of the heat transfer fluid in the outdoor heat exchanger portion and geothermal cooling of the heat transfer fluid in the geothermal heat exchanger portion.

Chainer, Timothy J.↗

A critical review of electrochemical heat pump technologies: Status, challenges, and perspectives

The development of advanced heat pump technologies is critical for reducing global energy consumption in the building sector, where space heating and cooling account for nearly 50% of energy use. Electrochemical heat pumps (EHPs) offer a promising alternative to vapor compression systems by enabling direct electrochemical-to-thermal energy conversion, often with environmentally benign working fluids that exhibit low or zero global warming potential (GWP). Prior literature has predominantly focused on chemically reactive heat pumps, while comprehensive assessments of electrochemical mechanisms remain limited. Here, this review addresses this gap by systematically evaluating the underlying principles, architectures, and performance metrics of EHP systems. Compared to conventional vapor compression systems, EHPs can achieve 10%-30% higher energy efficiency, with reported cooling coefficients of performance (COP c ) ranging from 3.5 to 14.3 under standard operating conditions. Despite these advantages, widespread adoption is hindered by challenges including membrane degradation, electrode fouling, sluggish redox kinetics, and elevated system-level capital costs. To address these limitations, the review outlines three research priorities: (i) the development of advanced membranes, catalysts, and electrode materials with enhanced chemical and mechanical stability; (ii) the application of molecular-level simulations for the rational design of high-performance redox-active working fluids; and (iii) the integration of advanced diagnostic techniques for real-time monitoring and sustained operation of EHPs. By consolidating recent advances and explicitly identifying technological and scientific gaps, this work uniquely contributes a comprehensive framework for guiding future electrochemical heat pump research and facilitating the transition to sustainable thermal management technologies.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

SAM Finite Volume Method Development Status Update: GCR Application, Restart, and MultiApp

The System Analysis Module (SAM) is being developed as a modern system analysis code for advanced non-light-water-reactor safety analysis under the U.S. DOE NEAMS program. Previous feasibility studies have demonstrated that a staggered-grid finite volume method (SG-FVM), implemented under the MOOSE framework, can deliver more than an order of magnitude speedup over the existing continuous Galerkin finite element method (CG-FEM) solver for liquid-cooled, incompressible but thermally expandable flow systems. This work extends the previous effort to compressible, gas-cooled reactor applications, where pressure couples directly into the mass equation adding additional nonlinearity into the equation system. New code capabilities are implemented for pebble bed high-temperature gas-cooled reactor (PB-HTGR) analysis, including a pebble bed CoreChannel component, built-in pebble bed effective thermal conductivity model and channel-to-channel crossflow model. The capabilities are tested, benchmarked, and demonstrated for problems with increased level of model and physical complexities, including the HTTU effective thermal conductivity test, the SANA passive cooling test, and a demonstration case using the GPBR200 reactor design covering steady-state operation, DLOFC and PLOFC transients. Across all cases, the SG-FVM solver demonstrated strong robustness and efficiency, and the solutions agree well with reference results and data. The finding of this work proves that SG-FVM is a viable and efficient solver pathway for compressible, gas-cooled reactor system analysis in SAM. In addition, work has been done to successfully support SAM-FVM recover/restart code feature that is essential to reactor safety analysis applications, and MultiApp code feature that is essential to multi-scale and multi-physics simulations. In summary, this work continued from previous feasibility studies, and further demonstrated that the SG-FVM will serve as a strong foundation for SAM’s advanced solver algorithm for future deployment.

Zou, Ling↗