Search NASA⌕ Search

SEARCH · Search NASA

Results for “Crew Performance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Sensor systems for the Altair Lunar Lander:

The Altair Lunar Lander will enable astronauts to learn to live and work on the moon for extended periods of time, providing the experience needed to expand human exploration farther into the solar system. My overriding recommendation: Use independent and complementary [sometimes referred to as 'orthogonal'] techniques to disambiguate confounding/interfering signals. E.g.: a mass spectrometer ['MS'], which currently serves as a Majority Constituent Analyzer ['MCA'] can be very valuable in detecting the presence of a gaseous specie, so long as it falls on a mass-to-charge ratio ['m/z'] that is not already occupied by a majority constituent of cabin air. Consider the toxic gas, CO. Both N{sub 2} and CO have parent peaks of m/z = 28, and CO{sub 2} has a fragment peak at m/z = 28 [and at 16 and 12], so the N{sub 2} and CO{sub 2} m/z=28 signals could mask low, but potentially-dangerous levels of CO. However there are numerous surface-sensitive CO detectors, as well as tunable-diode-laser-based CO sensors that could provide independent monitoring of CO. Also, by appending a gas chromatograph ['GC'] as the front-end sample processer, prior to the inlet of the MS, one can rely upon the GC to separate CO from N{sub 2} and CO{sub 2}, providing the crew with another CO monitor. If the Altair Lunar Lander is able to include a Raman-based MCA for N{sub 2}, O{sub 2}, H{sub 2}O, and CO{sub 2}, then each type of MCA would have cross-references, providing more confidence in the ongoing performance of each technique, and decreasing the risk that one instrument might fail to perform properly, without being noticed. See, also Dr. Pete Snyder's work, which states 'An orthogonal technologies sensor system appears to be attractive for a high confidence detection of presence and temporal characterization of bioaerosols.' Another recommendation: Use data fusion for event detection to decrease uncertainty: tie together the outputs from multiple sensing modalities - eNose, solid-state sensors, GC-IMS, GC-MS - via nonlinear algorithms, such as an 'artificial neural net.' MA Ryan at the JPL and Henry Abarbanel at UCSD are possible candidates to implement such an approach.

42 ENGINEERING↗

A Closed-Loop Distribution System Restoration Tool for Natural Disaster Recovery. Final CRADA report

We propose to continue the development of the restoration algorithms and the tool’s user interface, both of which have been developed under the GMLC-0131 project. This project aims to develop a distribution restoration decision support tool that will assist utilities in performing distribution restoration after extreme weather events in an optimal and efficient manner. The tool will integrate the weather information/forecasts and system fragility assessment together with the field measurement data to improve the situational awareness and estimate the system damage status. Advanced optimization models will be leveraged to dispatch repair crews and associated resources. New resources (e.g., automatic switches and distributed generators (DGs)) enabled by distribution automation and smart grid development will be utilized to reconfigure distribution grids and pick up loads promptly to reduce the outage sizes and durations. The closed-loop feature of the tool will make the tool adaptive to the evolving weather events and varying restoration capabilities. In this CRADA, we will collaborate with S&C Electric Company (S&C) to refine ANL-1060 (07/17/2019) the restoration algorithms that can be potentially applicable for any utility systems and vendor products, including: 1) Customizable information from both utility users and vendor users; 2) User interface design.

54 ENVIRONMENTAL SCIENCES↗

Maximizing Operational Efficiencies in Waste Management on the Hanford Plateau Remediation Contract in a Down-turned Market - 13484

Recent changes in DOE priorities and funding have pressed DOE and its contractors to look for innovative methods to sustain critical operations at sites across the Complex. At the Hanford Site, DOE Richland Operations and its prime contractor, CH2M Hill Plateau Remediation Company (CHPRC), have completed in-depth assessments of the Plateau Remediation Contract (PRC) operations that compared available funding to mission and operational objectives in an effort to maintain requisite safety and compliance margins while realizing cost savings that meet funding profiles. These assessments included confirmation of current baseline activities, identification of potential efficiencies, barriers to implementation, and potential increased risks associated with implementation. Six operating PRC waste management facilities were evaluated against three possible end-states: complete facility closure, maintaining base operations, and performing minimum safe surveillance and maintenance activities. The costs to completely close evaluated facilities were determined to be prohibitively high and this end-state was quickly dropped from consideration. A summary of the analysis of remaining options by facility, efficiencies identified, impact to risk profiles, and expected cost savings is provided in Table I. The expected cost savings are a result of: - right-sizing and cross-training work crews to address maintenance activities across facilities; - combining and sequencing 'like-moded' operational processes; - cross-cutting emergency planning and preparedness staffing; - resource redistribution and optimization; - reducing areas requiring routine surveillance and inspection. For the efficiencies identified, there are corresponding increases in risk, including a loss of breadth and depth of available resources; lengthened response time to emergent issues; inability to invest in opportunities for improvement (OFIs); potential single-point failures or non-compliancies due to resource scarcity; limited cross-training capability; and reduced capability to respond to changes in DOE priorities. Finally, there are many challenges to achieving these cost savings. With a workforce nearing retirement effective succession planning becomes critical to success and requires establishing a balance between the cost of hiring and training and cost-saving activities. With six active waste management facilities spread across nearly 15 square miles, scheduling and deploying cross-trained surveillance and maintenance teams is a logistical challenge, particularly as the loss of funding has not diminished emphasis by regulatory agencies placed on the safe and compliant performance of DOE and its contractors. As reflected in Table I, efficiencies are currently being implemented on the Hanford Plateau Remediation Contract (PRC) that deliver cost savings that align with the current site budget while maintaining critical capabilities. It is currently estimated that these efficiencies will result in a cost savings of approximately $9 million for FY13 in base and minimum safe operations on the PRC - a cost reduction of more than 13 percent over FY12 and nearly 30 percent over FY09 levels. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Challenges Conducting a Radiological Site Assessment at a Remote Uranium Mine - 16259

A radiological site assessment was performed as part of an environmental site assessment at a former uranium mine located in the Northwest Territories of Canada. The only access to the site was by helicopter, so the field program was a limited to only a few days. Radiological surveys were conducted to assess conditions for safety of the field crew as well as to provide overland survey of uranium at the site. Limited radiological data existed for this site and the objective was to collect as much data as possible during the short field program. ScanPlot{sup SM} gamma spectroscopy land survey system was utilized for the overland survey utilizing a backpack system. ScanPlotSM platform utilized spectroscopy grade sodium iodide detectors configured for optimal spatial coverage and radiation detection. Survey locations were recorded using an on-board global positioning system (GPS). The radiological spectral data from the radiation detectors is automatically logged and linked with the GPS coordinates to an on-board computer to create iso-contour figures using a color scale to represent radioactivity levels (ground concentration by radionuclide). The advantage of utilizing the ScanPlotSM system for this assessment is that the nature and extent of uranium is provided without having to collect and assay a large number of samples during a short period of time. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Comparison of Mutual Awareness in Analog vs. Digital Control Rooms

Control rooms in nuclear power plants are complex, collaborative working environments rife with potential for human error. As control rooms evolve from analog to digital interface environments, crew communication strategies must change as well. Operators in the analog control room operate the plant and communicate with each other with the help of control boards with large control panels, meters, and switches. Reactor operators could choose a particular set of controls on the particular control board which corresponds to the part of the system of interest. Visual display units (VDU), which became a fixture in the control rooms with the shift to digital human-machine interfaces (HMI), bring benefits for safety and flexibility combining information from various sources. With the increase in automation and the use of digital HMIs operators received their personal sitting workstations where they are able to navigate and operate the plant. The amount of information increased as well as the complexity of monitoring and analyzing the system states. Also computerized systems cause operators to get absorbed by their personal screens and reduce interaction between the crew members. Therefore, the collaboration and coordination of task demands requires vigilance and mutual awareness. The level of automation has an influence on the level of mutual awareness experienced by operators in the control rooms. Teams function to carry out highly interdependent tasks, requiring synthesis and sharing of information to achieve common goals. Improving the performance of the team necessitates the operators to focus on the system, the surrounding environment, and situational awareness about the system states. Collaboration of team members is critical when employing the digital operating systems as the acute awareness of the overall progress of the group and individual activities of the operators drives the team to the desired end-states of the plant operations. Out-of-the loop (OOTL) performance problems can be referred to as the lack of supervisory control, system monitoring, and information processing in the digital HMIs. Under some circumstances Senior Reactor Operators (SRO) struggle to follow the actions of other Reactor Operators (RO) because with the new digital interfaces SROs lose track of how the procedures are carried out by ROs, which results in the loss of three way communication. Mutual awareness plays a significant role in keeping the SROs in the loop of plant operations. This paper will investigate, through literature review and expert interviews, the impact and human errors attributed to the increasing complexity of new digital main control rooms. Comparison of the new digital interfaces with the analog interfaces in nuclear power plants has the potential to shed light on increasing mutual awareness and three way communications between the SROs and ROs. Further, identification of the human errors and human actions can provide beneficial information, suggesting significant and critical improvements that can be implemented in the main control rooms to increase safety and reliability of new technology. Additionally, insights on mutual awareness for analog vs. digital control rooms can serve to improve human reliability.

99 GENERAL AND MISCELLANEOUS↗

Market analysis of a looming crisis -decommissioning trends and a shrinking crew - 15276

Recent events and trends point to a scenario of more and more reactors being retired due to economic viability reasons, post- Fukushima requirements, and a stalling of the general 'nuclear renaissance'. Such a trend is already happening in the United States and will likely also occur in other countries where older reactors are coming to an end of their original operating license periods or where regulators have imposed additional requirements. In terms of projections for the US, we have performed an analysis based on a plausible scenario that shows that as many as 25 reactors may enter decommissioning in the next twenty years, in addition to the reactors already in decommissioning. A significant change that is happening is that the power plants can no longer apply the SAFSTOR option and a 'wait and see' strategy. The main driver for this change is state intervention along with other factors including the status of the decommissioning funds, long-term liability issues, and a strong public interest in early dismantlement and cleanup. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Plasma-jet printing of colloidal thermoelectric Bi 2 Te 3 nanoflakes for flexible energy harvesting

Thermoelectric generators (TEGs) convert temperature differences into electrical power and are attractive among energy harvesting devices due to their autonomous and silent operation. While thermoelectric materials have undergone substantial improvements in material properties, a reliable and cost-effective fabrication method suitable for microgravity and space applications remains a challenge, particularly as commercial space flight and extended crewed space missions increase in frequency. This paper demonstrates the use of plasma-jet printing (PJP), a gravity-independent, electromagnetic field-assisted printing technology, to deposit colloidal thermoelectric nanoflakes with engineered nanopores onto flexible substrates at room temperature. We observe substantial improvements in material adhesion and flexibility with less than 2% and 11% variation in performance after 10 000 bending cycles over 25 mm and 8 mm radii of curvature, respectively, as compared to previously reported TE films. Our printed films demonstrate electrical conductivity of 2.5 × 10 3 S m -1 and a power factor of 70 μW m -1 K -2 at room temperature. To our knowledge, these are the first reported values of plasma-jet printed thermoelectric nanomaterial films. This advancement in plasma jet printing significantly promotes the development of nanoengineered 2D and layered materials not only for energy harvesting but also for the development of large-scale flexible electronics and sensors for both space and commercial applications.

99 GENERAL AND MISCELLANEOUS↗

Camera Inspection Arm for Boiling Water Reactors - 13330

Boiling Water Reactor (BWR) outage maintenance tasks can be time-consuming and hazardous. Reactor facilities are continuously looking for quicker, safer, and more effective methods of performing routine inspection during these outages. In 2011, S.A. Technology (SAT) was approached by Energy Northwest to provide a remote system capable of increasing efficiencies related to Reactor Pressure Vessel (RPV) internal inspection activities. The specific intent of the system discussed was to inspect recirculation jet pumps in a manner that did not require manual tooling, and could be performed independently of other ongoing inspection activities. In 2012, SAT developed a compact, remote, camera inspection arm to create a safer, more efficient outage environment. This arm incorporates a compact and lightweight design along with the innovative use of bi-stable composite tubes to provide a six-degree of freedom inspection tool capable of reducing dose uptake, reducing crew size, and reducing the overall critical path for jet pump inspections. The prototype camera inspection arm unit is scheduled for final testing in early 2013 in preparation for the Columbia Generating Station refueling outage in the spring of 2013. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Design and implementation of HuREX analysis supporting interface - 171

Human error is recognized as one of the main causes to affect to the socio-technical system including nuclear power plant. Therefore, reducing human error through human reliability analysis (HRA) is a critical issue. Moreover, sufficient and reliable human performance data collection is a prerequisite for ensuring the safety of nuclear power plants. Korea Atomic Energy Research Institute developed the HuREX (Human Reliability data Extraction) framework to collect and analyze the responses of human operators from simulator training records of nuclear power plant. Thus, the development and computer software interfaces of the database are essential to efficiently support human reliability analysis. In this study, OPERA database was developed in accordance with the following process. First, the essential data required for the HRA analysis (e.g., plant data, procedures, system and equipment info, operating crews, results of simulator experiments, and so forth) was stored in the database. In addition, standardized procedures and related items were stored in the database to support HRA quantification. A data structure was developed to store crew responses conducted by operators to cope with an emergency situation during simulator experiments. In addition, various interfaces that escalate efficiency of the HuREX applications were developed. The HuREX analysis support interface was developed with HuREX Video Analyzer for observation of simulator collection data (e.g., audio-visual records, plant parameters, operator's action logs) and HuREX Data Analyzer for analysis of operator's conducted task. By using the OPERA database and HuREX analysis support interface developed through this research, maximizing the efficiency of human reliability analysis based on simulator training data. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

SPARCLE: Electrostatic Tool for Lunar Dust Control

Successful exploration of most planetary surfaces, with their impact-generated dusty regoliths, will depend on the capabilities to keep surfaces free of the dust which could compromise performance and to collect dust for characterization. Solving the dust problem is essential before we return to the Moon. During the Apollo missions, the discovery was made that regolith fines, or dust, behaved like abrasive velcro, coating surfaces, clogging mechanisms, and making movement progressively more difficult as it was mechanically stirred up during surface operations, and abrading surfaces, including spacesuits, when attempts were made to remove it manually. In addition, some of the astronauts experienced breathing difficulties when exposed to dust that got into the crew compartment. The successful strategy will deal with dust dynamics resulting from interaction between mechanical and electrostatic forces. Here we will describe the surface properties of dust particles, the basis for their behavior, and an electrostatically-based approach and methodology for addressing this issue confirmed by our preliminary results. Our device concept utilizes a focused electron beam to control the electrostatic potential of the surface. A plate of the opposite potential is then used to induce dust migration in the presence of an electrical field. Our goal is a compact device of <5 kg mass and using <5 watts of power to be operational in <5 years with heritage from ionic sweepers for active spacecraft potential control (e.g., on POLAR). Rovers could be fitted with devices that could harness the removal of dust for sampling as part of the extended exploration process on Mercury, Mars, asteroids or outer solar system satellites, as well as the Moon.

79 ASTRONOMY AND ASTROPHYSICS↗

Adapting ORAP to wind plants : industry value and functional requirements.

Strategic Power Systems (SPS) was contracted by Sandia National Laboratories to assess the feasibility of adapting their ORAP (Operational Reliability Analysis Program) tool for deployment to the wind industry. ORAP for Wind is proposed for use as the primary data source for the CREW (Continuous Reliability Enhancement for Wind) database which will be maintained by Sandia to enable reliability analysis of US wind fleet operations. The report primarily addresses the functional requirements of the wind-based system. The SPS ORAP reliability monitoring system has been used successfully for over twenty years to collect RAM (Reliability, Availability, Maintainability) and operations data for benchmarking and analysis of gas and steam turbine performance. This report documents the requirements to adapt the ORAP system for the wind industry. It specifies which existing ORAP design features should be retained, as well as key new requirements for wind. The latter includes alignment with existing and emerging wind industry standards (IEEE 762, ISO 3977 and IEC 61400). There is also a comprehensive list of thirty critical-to-quality (CTQ) functional requirements which must be considered and addressed to establish the optimum design for wind.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Computerized procedure systems: procedure edition and maintenance challenges - 232

Very few nuclear power plants are using computerized procedures to guide the control room operation. A CPS implementation consists of two processes: digitalization and computerization. The former deals with the transformation of paper-based procedure into a digital data; the latter is referred to as the addition to that data of extra information that is meaningful for decision-making. This information may include real-time data (plant parameter values and binary process values to indicate equipment states), provide access to trends and historical data, etc. In order to be efficient and to optimize the digitalization and computerization processes, these set of aids should be implemented at the same time as operating procedures are digitalized There are references of plants having successfully implemented Computerized Procedures Systems (CPS) for emergency procedures, but when questioned about normal or abnormal operating procedures, operators and plant management seem reluctant to take that step. Given that a CPS is meant, by design concept, to increase operation crew efficiency by facilitating the procedures execution and reducing human error, why are we reluctant to enjoy CPS benefits in the most common plant status (i.e. normal operation)? Although there are many answers to this question, one is shared by most of the users: CPSs are not designed for editing and maintaining procedures easily and reliably. Normal operating procedures, in opposition to the emergency procedures, are often reviewed. Nowadays, these edition activities are performed easily with a word processor software and using paper, but what is required when dealing with a CPS? (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Upgrades to Alabama Power Company Hydroelectric Developments

From 2010 to 2014, Alabama Power Company (“Alabama Power”) performed upgrades on four units at three of the hydropower developments it operates in east-central Alabama under licenses issued by the Federal Energy Regulatory Commission (“FERC”). These three hydropower developments are located on the Coosa River in Coosa, Chilton, and Elmore counties in east-central Alabama.

13 HYDRO ENERGY↗

A Toolbox Necessity: Finding Best Practices in High-Performance Homes with the Building America Solution Center

The U.S. Department of Energy’s Building America Solution Center is a free, easy-to-access web tool containing the latest building science research from the Building America program. This paper describes how the Solution Center is bringing best practices for high-performance homes to members of the building industry to help their businesses to gain an edge to help expand their markets. It includes a tour of the Solution Center’s newest features and updates. The Building America Solution Center provides full and simple access to a wealth of best practices based on building science and energy efficiency research generated by the Building America program, along with other resources to help builders specify features, train crews, complete quality installations, and sell houses. This paper supports the visual presentation with the same title. The paper will be submitted for inclusion in the ACEEE Summer Study 2018 proceedings. The poster will be presented at the ACEEE 2018 Summer Study conference.

.S. Department of Energy Building Technologies Pro↗

Umatilla Basin Fish Facilities Operation & Maintenance : Annual Report Fiscal Year 2008.

Westland Irrigation District, as contractor to Bonneville Power Administration, and West Extension Irrigation District, as subcontractor to Westland, provide labor, equipment, and material necessary for the operation, care, and maintenance of fish facilities on the Umatilla River. Westland Irrigation District is the contractor of record. Job sites that are covered: Three Mile Right, Three Mile Left, Three Mile Adult Spawning, WEID Sampling Facility, Maxwell Screen Site, Westland Screen Site/Ladder/Juvenile Sampling Facility, Feed Canal Ladder/Screen Site, Stanfield Ladder/Screen Site, Minthorn Holding Facility, Thornhollow Acclimation Site, Imeques Acclimation Site, Pendleton Acclimation Site, and South Fork Walla Walla Spawning Facility. O & M personnel coordinate with the Confederated Tribes of the Umatilla Indian Reservation (CTUIR) and Oregon Department of Fish and Wildlife (ODFW) personnel in performing tasks under this contract including scheduling of trap and haul, sampling, acclimation site maintenance, and other related activities as needed. The input from ODFW biologists Bill Duke and Ken Loffink, and CTUIR biologist Preston Bronson is indispensable to the success of the project, and is gratefully acknowledged. All tasks associated with the project were successfully completed during the fiscal year 2008 work period of October, 2007 through September, 2008. The project provides operations and maintenance throughout the year on five fish screen sites with a total of thirty-four rotating drum-screens, and four fish ladders in the Umatilla River Basin; additionally, periodic operations and maintenance is performed at holding, acclimation, and spawning sites in the Basin. Three people are employed full-time to perform these tasks. The FY08 budget for this project was $492,405 and actual expenditures were $490,267.01. Selected work activities and concerns: (1) Feed Dam Passage Improvement Project - A project to improve fish passage over the short term at the Feed Canal Diversion Dam site (Umatilla River mile 28.7) was implemented with local U.S. Bureau of Reclamation field office personnel coordinating project activities. Operation and Maintenance Project personnel assisted with labor, materials, and equipment to ensure the project was completed as planned. Discussions are under way to determine feasible alternatives for longer term solutions to passage issues at the site. (2) Three Mile Right (east bank) Facilities - The pump for supplying water to the fish handling facility holding pond was reconstructed successfully to achieve the desired increase in flow output necessary when increased quantities of fish are present. (3) Fish Screen Rehab at Stanfield Canal Diversion - Working with the Washington Department of Fish and Wildlife screen shop personnel, three rotating drum screens at the Stanfield Canal diversion site (Umatilla River mile 33.3) were serviced and overhauled with new bearings, seals, paint, and reinforcing bars. Work was completed, and screens reinstalled prior to water diversions beginning in the spring. (4) O & M personnel performed daily, weekly, and monthly operations and maintenance duties at the screen and ladder sites including, but not limited to, desilting of mud and debris, lubrication of mechanical parts, replacement of screen seals and screen motor components, adjustment of ladder gates, removal of large trees and woody debris deposited during high river flow conditions, servicing of pumps and screens for fish handling operations and sampling studies, in addition to general site clean-up, vegetative control, and security. Crew members responded as needed during evenings and after-hours according to weather conditions, river flows, and fish passage facility needs.

13 HYDRO ENERGY↗

Integration of energy storage with diesel generation in remote communities

Highlights Battery energy storage may improve energy efficiency and reliability of hybrid energy systems composed by diesel and solar photovoltaic power generators serving isolated communities. In projects aiming update of power plants serving electrically isolated communities with redundant diesel generation, battery energy storage can improve overall economic performance of power supply system by reducing fuel usage, decreasing capital costs by replacing redundant diesel generation units, and increasing generator system life by shortening yearly runtime. Fast-acting battery energy storage systems with grid-forming inverters might have potential for improving drastically the reliability indices of isolated communities currently supplied by diesel generation. Abstract This paper will highlight unique challenges and opportunities with regard to energy storage utilization in remote, self-sustaining communities. The energy management of such areas has unique concerns. Diesel generation is often the go-to power source in these scenarios, but these systems are not devoid of issues. Without dedicated maintenance crews as in large, interconnected network areas, minor interruptions can be frequent and invasive not only for those who lose power, but also for those in the community that must then correct any faults. Although the immediate financial benefits are perhaps not readily apparent, energy storage could be used to address concerns related to reliability, automation, fuel supply concerns, generator degradation, solar utilization, and, yes, fuel costs to name a few. These ideas are shown through a case study of the Levelock Village of Alaska. Currently, the community is faced with high diesel prices and a difficult supply chain, which makes temporary loss of power very common and reductions in fuel consumption very impactful. This study will investigate the benefits that an energy storage system could bring to the overall system life, fuel costs, and reliability of the power supply. The variable efficiency of the generators, impact of startup/shutdown process, and low-load operation concerns are considered. The technological benefits of the combined system will be explored for various scenarios of future diesel prices and technology maintenance/replacement costs as well as for the avoidance of power interruptions that are so common in the community currently. Graphic abstract Discussion In several cases, energy storage can provide a means to promote energy equity by improving remote communities’ power supply reliability to levels closer to what the average urban consumer experiences at a reduced cost compared to transmission buildout. Furthermore, energy equity represents a hard-to-quantify benefit achieved by the integration of energy storage to isolated power systems of under-served communities, which suggests that the financial aspects of such projects should be questioned as the main performance criterion. To improve battery energy storage system valuation for diesel-based power systems, integration analysis must be holistic and go beyond fuel savings to capture every value stream possible.

25 ENERGY STORAGE↗

Lower Three Runs Remediation Safety Preparation Strategy - 13318

The Savannah River Site (SRS) is a 310-square-mile United States Department of Energy (US DOE) nuclear facility located along the Savannah River near Aiken, South Carolina that contains six primary stream/river systems. The Lower Three Runs Stream (LTR) is one of the primary streams within the site that is located in the southeast portion of the Savannah River Site. It is a large blackwater stream system that originates in the northeast portion of SRS and follows a southerly direction before it enters the Savannah River. During reactor operations, secondary reactor cooling water, storm sewer discharges, and miscellaneous wastewater was discharged and contaminated a 20 mile stretch of Lower Three Runs Stream that narrows and provides a limited buffer of US DOE property along the stream and flood-plain. Based on data collected during the years 2009 and 2010 under American Recovery and Re-investment Act funding, the stream was determined to be contaminated with cesium-137 at levels that exceeded acceptable risk based limits. In agreement with the Environmental Protection Agency and the South Carolina Department of Health and Environmental Control, three areas were identified for remediation [1] (SRNS April 2012). A comprehensive safety preparation strategy was developed for safe execution of the LTR remediation project. Contract incentives for safety encouraged the contractor to perform a complete evaluation of the work and develop an implementation plan to perform the work. The safety coverage was controlled to ensure all work was observed and assessed by one person per work area within the project. This was necessary due to the distances between the fence work and three transects being worked, approximately 20 miles. Contractor Management field observations were performed along with DOE assessments to ensure contractor focus on safe performance of the work. Dedicated ambulance coverage for remote worker work activities was provided. This effort was augmented with access to medical evacuation services. The areas where the work was performed were remote and difficult to get emergency vehicles to in a timely manner in case of an accident. Satellite phones were utilized due to intermittent phone coverage. High visibility vests were utilized to enable any hunters in the area to see the workers; due to the limited buffer areas along the stream route. An innovative approach to providing the necessary protection for workers during periods of extreme heat and humidity was also employed, which included the use of 'heat islands' with fans and crew trailers and ice vests for workers. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Hydra: Computer Vision for Data Quality Monitoring

Hydra: Computer Vision for Data Quality Monitoring Mar 13, 2024, 4:15 PM 30m Charles B. Wang Center, Stony Brook University Poster Track 1: Computing Technology for Physics Research Poster session with coffee break Speaker Ayan Roy Description Hydra is an extensible framework for training, managing, and deploying machine learning models for near real-time data quality monitoring. It is designed to take some of the burden off of shift crews by providing ‘round-the-clock’ monitoring of plots representing the data being collected. The Hydra system is backed by a database which is leveraged for near push button training and is primarily controlled and viewed through a set of web interfaces. This web interface contains a simple-to-use web based GUI for labeling of the datasets used in training; making it possible to label thousands of images quickly and efficiently. To aid in the analysis of Hydra inferences gradCAM, a method of interpretability, is performed and overlaid on the target image, highlighting regions of interest, making diagnosis of problems much faster. Development began in 2019 for the GlueX Experiment in Hall-D, the Hydra system has grown to encompass all of the experimental halls at Jefferson Laboratory. This talk will focus on the features of Hydra as well as provide details of the challenges present with deploying to disparate experimental halls. With a roadmap of development established, Hydra aims to continue to grow in richness of feature set and expand to encompass other monitoring tasks in differing communities.

Roy, Ayan↗