Search NASA⌕ Search

SEARCH · Search NASA

Results for “Cryogenic valves”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

A Finite Volume Procedure for Thermo-Fluid System Analysis in a Flow Network

This paper describes a finite volume procedure for network flow analysis in a thermofluid system. A flow network is defined as a group of inter-connected control volumes called “nodes” that are connected by “branches”. The mass and energy conservation equations are solved at the nodes and momentum conservation equations are solved at the branches. The flow network also includes solid nodes to account for fluid to solid heat transfer. The heat conduction equation is solved at the solid nodes in conjunction with the flow equations. The properties of a real fluid are calculated using a thermodynamic property program and used in the conservation equations. The system of equations describing the fluid-solid network is solved by a hybrid numerical method that is a combination of the Newton-Raphson and successive substitution method. This procedure has been incorporated into a general-purpose computer program, the Generalized Fluid System Simulation Program, GFSSP. This paper also presents the application and verification of the method by comparison with test data for several applications that include (a) internal flow in a rocket engine turbo-pump, (b) pressurization and loading of a cryogenic propellant tank, (c) fluid transient during sudden opening of valve for priming of an evacuated feed line, and (d) chill down of a cryogenic transfer line with phase change and two phase flows.

Majumdar, Alok↗

NASA Tech Briefs, November 2006

Topics include: Simulator for Testing Spacecraft Separation Devices; Apparatus for Hot Impact Testing of Material Specimens; Instrument for Aircraft-Icing and Cloud-Physics Measurements; Advances in Measurement of Skin Friction in Airflow; Improved Apparatus for Testing Monoball Bearings; High-Speed Laser Scanner Maps a Surface in Three Dimensions; Electro-Optical Imaging Fourier-Transform Spectrometer; Infrared Instrument for Detecting Hydrogen Fires; Modified Coaxial Probe Feeds for Layered Antennas; Detecting Negative Obstacles by Use of Radar; Cryogenic Pound Circuits for Cryogenic Sapphire Oscillators; PixelLearn; New Software for Predicting Charging of Spacecraft; Conversion Between Osculating and Mean Orbital Elements; Generating a 2D Representation of a Complex Data Structure; Making Activated Carbon by Wet Pressurized Pyrolysis; Composite Solid Electrolyte Containing Li+- Conducting Fibers; Electrically Conductive Anodized Aluminum Surfaces; Rapid-Chill Cryogenic Coaxial Direct-Acting Solenoid Valve; Variable-Tension-Cord Suspension/Vibration- Isolation System; Techniques for Connecting Superconducting Thin Films; Versatile Friction Stir Welding/Friction Plug Welding System; Thermal Spore Exposure Vessels; Enumerating Spore-Forming Bacteria Airborne with Particles; Miniature Oxidizer Ionizer for a Fuel Cell; Miniature Ion-Array Spectrometer; Promoted-Combustion Chamber with Induction Heating Coil; Miniature Ion-Mobility Spectrometer; Mixed-Salt/Ester Electrolytes for Low-Temperature Li+ Cells; Miniature Free-Space Electrostatic Ion Thrusters; Miniature Bipolar Electrostatic Ion Thruster; Holographic Plossl Retroreflectors; Miniature Electrostatic Ion Thruster With Magnet; Using Apex To Construct CPM-GOMS Models; Sequence Detection for PPM Optical Communication With ISI; Algorithm for Rapid Searching Among Star-Catalog Entries; Expectation-Based Control of Noise and Chaos; Radio Heating of Lunar Soil to Release Gases; Using Electrostriction to Manipulate Ullage in Microgravity; Equations for Scoring Rules When Data Are Missing; Insulating Material for Next-Generation Spacecraft; and Pseudorandom Switching for Adding Radar to the AFF Sensor.

Source record↗

Test data analysis of the thermodynamic vent system-augmented top spray injector liquid nitrogen transfer experiments

Traditionally, a cryogenic tank must be pre-chilled to some “target” temperature before the main vent valve can be closed to attempt a non-vented fill (NVF) of cryogenic liquid propellant. This methodology is particularly attractive for performing in-space transfer of cryogens due to the unknown location of the liquid/vapor interface in microgravity and the high likelihood of venting liquid if the vent valve is opened during transfer. This paper presents in-depth test data analysis of a Thermodynamic Vent System (TVS) augmented injector used for cryogenic tank chilldown and fill experiments of a thin-walled Titanium tank. Eight tests were conducted using liquid nitrogen across a range of inlet conditions and boundary conditions, and three different chilldown/fill methods. For four of the tests, the injector sprays liquid into the tank as normal, but also uses a TVS heat exchanger to cool the metallic injector itself as well as the main incoming liquid stream. Results show that using the TVS augmented injector simplifies transfer operation via enhanced condensation at the injector surface at the cost of sacrificing only a small amount of propellant.

No-vent Fill↗

Computer Controlled High Vacuum Gas Purification and Analysis Line

Light stable isotope work requires the handling of gasses such a way that does not alter isotopic composition. To do this, there are a large number of analytical and experimental procedures which involve the use of a vacuum line, numerous “egg timers” and a human hand on a valve. Unfortunately, the human hand is inconsistent and inadvertent small, and commonly large, differences in timing can have a measurable effect on outcomes. We have constructed a computer controlled high-vacuum line to be used as an expandable platform for future experimental and analytical procedures. The vacuum line consists of an electropolished 316 stainless steel system of cryogenic u-traps partitioned by pneumatic valves. The code to operate the line has been developed using the LabView platform and will allow for automated timing, consistent valve opening speed and unattended operation of long analytical procedures. The aim of this project is to address a need in the light stable isotope laboratory for a general-purpose vacuum line for handling and manipulation of gasses. When combined with existing instrumentation it allows for a significant expansion of current analytical capabilities. The system allows for better handling of standards, gas conversion techniques and gas sample collection for interlaboratory comparisons. The basic structure of the line, automation hardware and software were chosen and designed to provide a base for future expansion of the system to incorporate new automated analytical techniques as laboratory instrumentation and analytical needs expand.

High vacuum↗

Analysis of Complex Valve and Feed Systems

A numerical framework for analysis of complex valve systems supports testing of propulsive systems by simulating key valve and control system components in the test loop. In particular, it is designed to enhance the analysis capability in terms of identifying system transients and quantifying the valve response to these transients. This system has analysis capability for simulating valve motion in complex systems operating in diverse flow regimes ranging from compressible gases to cryogenic liquids. A key feature is the hybrid, unstructured framework with sub-models for grid movement and phase change including cryogenic cavitations. The multi-element unstructured framework offers improved predictions of valve performance characteristics under steady conditions for structurally complex valves such as pressure regulator valve. Unsteady simulations of valve motion using this computational approach have been carried out for various valves in operation at Stennis Space Center such as the split-body valve and the 10-in. (approx.25.4-cm) LOX (liquid oxygen) valve and the 4-in. (approx.10 cm) Y-pattern valve (liquid nitrogen). Such simulations make use of variable grid topologies, thereby permitting solution accuracy and resolving important flow physics in the seat region of the moving valve. An advantage to this software includes possible reduction in testing costs incurred due to disruptions relating to unexpected flow transients or functioning of valve/flow control systems. Prediction of the flow anomalies leading to system vibrations, flow resonance, and valve stall can help in valve scheduling and significantly reduce the need for activation tests. This framework has been evaluated for its ability to predict performance metrics like flow coefficient for cavitating venturis and valve coefficient curves, and could be a valuable tool in predicting and understanding anomalous behavior of system components at rocket propulsion testing and design sites.

Ahuja, Vineet↗

Cold Helium Gas Pressurization For Spacecraft Cryogenic Propulsion Systems

To reduce the dry mass of a spacecraft pressurization system, helium pressurant may be stored at low temperature and high pressure to increase mass in a given tank volume. Warming this gas through an engine heat exchanger prior to tank pressurization both increases the system efficiency and simplifies the designs of intermediate hardware such as regulators, valves, etc. since the gas is no longer cryogenic. If this type of cold helium pressurization system is used in conjunction with a cryogenic propellant, though, a loss in overall system efficiency can be expected due to heat transfer from the warm ullage gas to the cryogenic propellant which results in a specific volume loss for the pressurant, interpreted as the Collapse Factor. Future spacecraft with cryogenic propellants will likely have a cold helium system, with increasing collapse factor effects as vehicle sizes decrease. To determine the collapse factor effects and overall implementation strategies for a representative design point, a cold helium system was hotfire tested on the Integrated Cryogenic Propulsion Test Article (ICPTA) in a thermal vacuum environment at the NASA Glenn Research Center Plum Brook Station. The ICPTA vehicle is a small lander-sized spacecraft prototype built at NASA Johnson Space Center utilizing cryogenic liquid oxygen/liquid methane propellants and cryogenic helium gas as a pressurant to operate one 2,800lbf 5:1 throttling main engine, two 28lbf Reaction Control Engines (RCE), and two 7lbf RCEs (Figure 1). This vehicle was hotfire tested at a variety of environmental conditions at NASA Plum Brook, ranging from ambient temperature/simulated high altitude, deep thermal/high altitude, and deep thermal/high vacuum conditions. A detailed summary of the vehicle design and testing campaign may be found in Integrated Cryogenic Propulsion Test Article Thermal Vacuum Hotfire Testing, AIAA JPC 2017.

Morehead, Robert L.↗

Propulsion Technology Needs for Exploration

The objectives of currently planned exploration efforts, as well as those further in the future, require significant advancements in propulsion technologies. The current Lunar exploration architecture has set goals and mission objectives that necessitate the use of new systems and the extension of existing technologies beyond present applications. In the near term, the majority of these technologies are the result of a need to apply high performing cryogenic propulsion systems to long duration in-space applications. Advancement of cryogenic propulsion to these applications is crucial to provide higher performing propulsion systems that reduce the vehicle masses; enhance the safety of vehicle systems and ground operations; and provide a path for In-situ Resource Utilization (ISRU).Use of a LOX/LH2 main propulsion system for Lunar Lander Descent is a top priority because more conventional storable propellants are far from meeting the performance needs of the current architecture. While LOX/LH2 pump feed engines have been used in flight applications for many years, these engines have limited throttle capabilities. Engines that are capable of much greater throttling while still meeting high performance goals are a necessity to achieving exploration goals. Applications of LOX/CH4 propulsion to Lander ascent propulsion systems and reaction control systems are also if interest because of desirable performance and operations improvements over conventional storable systems while being more suitable for use of in-situ produced propellants. Within the current lunar architecture, use of cryogenic propulsion for the Earth Departure Stage and Lunar Lander elements also necessitate the need for advanced Cryogenic Fluid Management technologies. These technologies include long duration propellant storage/distribution, low-gravity propellant management, cryogenic couplings and disconnects, light weight composite tanks and support structure, and subsystem integration. In addition to the propulsive and fluid management system technologies described, many component level technologies are also required to enable to the success if the integrated systems. The components include, but are not limited to, variable/throttling valves, variable position actuators, leak detectors, light weight cryogenic fluid pumps, sensor technology and others. NASA, partnering with the Aerospace Industry must endeavor to develop these, and other promising propulsion technologies, to enable the implements of the country's goals in exploration of the Moon, Mars and beyond.

Brown, Thomas↗

Valve-"Health"-Monitoring System

A system that includes sensors and data acquisition, wireless data-communication, and data-processing subsystems has been developed as a means of both real-time and historical tracking of information indicative of deterioration in the mechanical integrity and performance of a highgeared ball valve or a linearly actuated valve that operates at a temperature between cryogenic and ambient.

Jensen, Scott L.↗

Application of Model-based Prognostics to a Pneumatic Valves Testbed

Pneumatic-actuated valves play an important role in many applications, including cryogenic propellant loading for space operations. Model-based prognostics emphasizes the importance of a model that describes the nominal and faulty behavior of a system, and how faulty behavior progresses in time, causing the end of useful life of the system. We describe the construction of a testbed consisting of a pneumatic valve that allows the injection of faulty behavior and controllable fault progression. The valve opens discretely, and is controlled through a solenoid valve. Controllable leaks of pneumatic gas in the testbed are introduced through proportional valves, allowing the testing and validation of prognostics algorithms for pneumatic valves. A new valve prognostics approach is developed that estimates fault progression and predicts remaining life based only on valve timing measurements. Simulation experiments demonstrate and validate the approach.

prediction↗

Numerical Analysis of Cavitation-Induced Two-Phase Fluid Transients in Cryogenic Feedlines Using Finite Volume Procedure

This article presents a numerical investigation of the cavitation induced fluid transient in cryogenic feedline due to sudden closure of the valve A one dimensional numerical model based on finite volume procedure consisting of nodes and branches using Generalized Fluid System Simulation Program ( has been employed for the prediction of pressure variations The unsteady friction formulation accurately determines wall shear stress, and a homogeneous mixture model is used for two phase flow modeling Numerical results obtained with the present formulation are compared with experimental results and Method of Characteristic ( based results It is observed that low residual in flow variable calculation improves the solution providing numerically stable results GFSSP is able to reproduce the fluid transient peak due to vapor collapse Subsequently, it can retain the shape of pressure wave for two phase fluid transients, but it is dampening faster compared to experiments Further investigation is required with set of experiments to validate the present numerical approach for different experimental data.

Fluid Transient↗

Sensitive low-pressure relief valve has positive seating against leakage

A pilot-operated relief valve which provides positive seating against leakage in cryogenic systems is described. The principal advantage is that the pilot poppet is unaffected by variations in control pressures in the pilot cavity, and results in a more accurate sensing of inlet pressure conditions.

Source record↗

Estimating Transient Pressure Surges in Cryogenic Systems

Potentially-damaging pressure waves anticipated and, therefore, avoided. Mathematical model developed for prediction of pressure behavior in single-and two-phase cryogenic systems. Transient liquid-flow analysis modified to incorporate behavior of vapor bubbles and used to predict maximum pressure in cryogenic transfer systems consisting of complex pipe and valve arrangements under both steady-state and transient conditions. Simulation compared favorably with data obtained during transfer of liquid oxygen from ground storage tanks to Space Shuttle orbiter external tanks. Program written in FORTRAN 77 for batch execution.

Pfister, P.↗

Improved cryogenic shaft seals

Seals are designed for use with liquid propellant ball valves at temperatures ranging from -400 F to 130 F and 8,000 psig. Seals are capable of sustaining 90 degree rotation, with substantial amount of lateral and axial play, caused by large pressure loads and differential thermal contraction.

Gillon, W. A., Jr.↗

A Testbed for Implementing Prognostic Methodologies on Cryogenic Propellant Loading Systems

Prognostics technologies determine the health state of a system and predict its remaining useful life. With this information, operators are able to make maintenance-related decisions, thus effectively streamlining operational and mission-level activities. Experimentation on testbeds representative of critical systems is very useful for the maturation of prognostics technology; precise emulation of actual fault conditions on such a testbed further validates these technologies. In this paper we present the development of a pneumatic valve testbed, initial experimental results and progress towards the maturation and validation of component-level prognostic methods in the context of cryogenic refueling operations. The pneumatic valve testbed allows for the injection of time-varying leaks with specified damage progression profiles in order to emulate common valve faults. The pneumatic valve testbed also contains a battery used to power some pneumatic components, enabling the study of the effects of battery degradation on the operation of the valves.

Prognositcs↗

Precision cleaning verification of fluid components by air/water impingement and total carbon analysis

NASA personnel at Kennedy Space Center's Material Science Laboratory have developed new environmentally sound precision cleaning and verification techniques for systems and components found at the center. This technology is required to replace existing methods traditionally employing CFC-113. The new patent-pending technique of precision cleaning verification is for large components of cryogenic fluid systems. These are stainless steel, sand cast valve bodies with internal surface areas ranging from 0.2 to 0.9 sq m. Extrapolation of this technique to components of even larger sizes (by orders of magnitude) is planned. Currently, the verification process is completely manual. In the new technique, a high velocity, low volume water stream impacts the part to be verified. This process is referred to as Breathing Air/Water Impingement and forms the basis for the Impingement Verification System (IVS). The system is unique in that a gas stream is used to accelerate the water droplets to high speeds. Water is injected into the gas stream in a small, continuous amount. The air/water mixture is then passed through a converging/diverging nozzle where the gas is accelerated to supersonic velocities. These droplets impart sufficient energy to the precision cleaned surface to place non-volatile residue (NVR) contaminants into suspension in the water. The sample water is collected and its NVR level is determined by total organic carbon (TOC) analysis at 880 C. The TOC, in ppm carbon, is used to establish the NVR level. A correlation between the present gravimetric CFC113 NVR and the IVS NVR is found from experimental sensitivity factors measured for various contaminants. The sensitivity has the units of ppm of carbon per mg/sq ft of contaminant. In this paper, the equipment is described and data are presented showing the development of the sensitivity factors from a test set including four NVRs impinged from witness plates of 0.05 to 0.75 sq m.

Barile, Ronald G.↗

Precision Cleaning Verification of Fluid Components by Air/Water Impingement and Total Carbon Analysis

NASA personnel at Kennedy Space Center's Material Science Laboratory have developed new environmentally sound precision cleaning and verification techniques for systems and components found at the center. This technology is required to replace existing methods traditionally employing CFC-113. The new patent-pending technique of precision cleaning verification is for large components of cryogenic fluid systems. These are stainless steel, sand cast valve bodies with internal surface areas ranging from 0.2 to 0.9 m(exp 2). Extrapolation of this technique to components of even larger sizes (by orders of magnitude) is planned. Currently, the verification process is completely manual. In the new technique, a high velocity, low volume water stream impacts the part to be verified. This process is referred to as Breathing Air/Water Impingement and forms the basis for the Impingement Verification System (IVS). The system is unique in that a gas stream is used to accelerate the water droplets to high speeds. Water is injected into the gas stream in a small, continuous amount. The air/water mixture is then passed through a converging-diverging nozzle where the gas is accelerated to supersonic velocities. These droplets impart sufficient energy to the precision cleaned surface to place non-volatile residue (NVR) contaminants into suspension in the water. The sample water is collected and its NVR level is determined by total organic carbon (TOC) analysis at 880 C. The TOC, in ppm carbon, is used to establish the NVR level. A correlation between the present gravimetric CFC-113 NVR and the IVS NVR is found from experimental sensitivity factors measured for various contaminants. The sensitivity has the units of ppm of carbon per mg-ft(exp 2) of contaminant. In this paper, the equipment is described and data are presented showing the development of the sensitivity factors from a test set including four NVR's impinged from witness plates of 0.05 to 0.75 m(exp 2).

Barile, Ronald G.↗