Search NASA⌕ Search

SEARCH · Search NASA

Results for “Cryogenics Test Laboratory”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Experimental Observations on Material Damping at Cryogenic Temperatures

This paper describes a unique experimental facility designed to measure damping of materials at cryogenic temperatures for the Terrestrial Planet Finder (TPF) mission at the Jet Propulsion Laboratory. The test facility removes other sources of damping in the measurement by avoiding frictional interfaces, decoupling the test specimen from the support system, and by using a non-contacting measurement device. Damping data reported herein are obtained for materials (Aluminum, Aluminum/Terbium/Dysprosium, Titanium, Composites) vibrating in free-free bending modes with low strain levels (< 10(exp -6) ppm). The fundamental frequencies of material samples are ranged from 14 to 202 Hz. To provide the most beneficial data relevant to TPF-like precision optical space missions, the damping data are collected from room temperatures (around 293 K) to cryogenic temperatures (below 40 K) at unevenly-spaced intervals. More data points are collected over any region of interest. The test data shows a significant decrease in viscous damping at cryogenic temperatures. The cryogenic damping can be as low as 10(exp -4) %, but the amount of the damping decrease is a function of frequency and material. However, Titanium 15-3-3-3 shows a remarkable increase in damping at cryogenic temperatures. It demonstrates over one order of magnitude increase in damping in comparison to Aluminum 6061-T6. Given its other properties (e.g., good stiffness and low conductivity) this may prove itself to be a good candidate for the application on TPF. At room temperatures, the test data are correlated well with the damping predicted by the Zener theory. However, large discrepancies at cryogenic temperatures between the Zener theory and the test data are observed.

Terrestrial Planet Finder (TPF)↗

A Focus on Cryogenic Engineering for the Primordial Inflation Polarization Explorer (PIPER) Mission

Cryogenic engineering involves design and modification of equipment that is used under boiling point of nitrogen which is 77 K. The focus of this paper will be on the design of hardware for cryogenic use and a retrofit that was done to the main laboratory cryostat used to test flight components for the Primordial Inflation Polarization Explorer balloon-borne mission. Data from prior tests showed that there was a superfluid helium leak and a total disassemble of the cryostat was conducted in order to localize and fix the leak. To improve efficiency new fill tubes and clamps with modifications were added to the helium tank. Upon removal of the tank, corrosion was found on the flange face that connects to the helium cold plate and therefore had to be fully replaced and copper plated to prevent future corrosion. Indium seals were also replaced for the four fill tubes, a helium level sensor, and the nitrogen and helium tanks. Four additional shielded twisted pairs of cryogenic wire and a wire harness for the Superconducting Quantum Interference Devices (SQUIDs) were added. Finally, there was also design work done for multiple pieces that went inside the cryostat and a separate probe used to test the SQUIDs. Upon successful completion of the cryostat upgrade, tests were run to check the effectiveness and stability of the upgrades. The post-retrofit tests showed minor leaks were still present and due to this, superfluidity has still not been attained. As such there could still be a possibility of a superfluid leak appearing in the future. Regardless, the copper plating on the helium tank has elongated the need to service it by three to five years.

Rosas, Rogelio↗

Special requirements in the design of a sensor test and integration laboratory

Special needs are imposed on the design and operation of a sensor test and integration lab. Cryogenic temperature, vibration isolation for electro-optical equipment, contamination control, thermal control to reduce or minimize thermally induced stresses on mirrors and supporting metering structure, thermal vacuum chamber shroud temperature uniformity, and varying temperature control capability to bring optical equipment from cryogenic temperature to ambient environment, and real time processing are some of the stringent needs that must be addressed before a facility can be accepted to perform sensor test and integration. Most of the sensor tests are performed at cryogenic temperature, and thermal isolation of the test article from the ambient temperature is a strong consideration for the thermal vacuum chamber design. Also, equipment heat and parasitic heat sources must be able to be removed from the chamber without exceeding the chamber shroud temperature gradients. How these needs were met in the design, build, and acceptance test of the Grumman Sensor Test and Integration Lab (STIL) is described.

Bellanca, S.↗

Multispectral Linear Array (MLA) science and technology program

A Goddard Space Flight Center program of science studies and technology development to provide the basis for future earth observation sensors employing multispectral linear array (MLA) technology is described. Establishment of MLA performance parameters and performance modeling make up the primary science activities. Critical technologies being developed include: short-wave infrared (SWIR) detector arrays, visible/and near infrared detector arrays, and passive cryogenic coolers. Supporting activities include: test and field instrument development, focal plane research and assessment laboratory, system simulation laboratory, calibration sources and techniques, optics, and thermal infrared arrays.

Barnes, W. L.↗

Glass Bubbles Insulation for Liquid Hydrogen Storage Tanks

A full-scale field application of glass bubbles insulation has been demonstrated in a 218,000 L liquid hydrogen storage tank. This work is the evolution of extensive materials testing, laboratory scale testing, and system studies leading to the use of glass bubbles insulation as a cost efficient and high performance alternative in cryogenic storage tanks of any size. The tank utilized is part of a rocket propulsion test complex at the NASA Stennis Space Center and is a 1960's vintage spherical double wall tank with an evacuated annulus. The original perlite that was removed from the annulus was in pristine condition and showed no signs of deterioration or compaction. Test results show a significant reduction in liquid hydrogen boiloff when compared to recent baseline data prior to removal of the perlite insulation. The data also validates the previous laboratory scale testing (1000 L) and full-scale numerical modeling (3,200,000 L) of boiloff in spherical cryogenic storage tanks. The performance of the tank will continue to be monitored during operation of the tank over the coming years.

Glass bubble↗

Linear Thermal Expansion Measurements of Lead Magnesium Niobate (PMN) Electroceramic Material for the Terrestrial Planet Finder Coronagraph

Linear thermal expansion measurements of nine samples of Lead Magnesium Niobate (PMN) electroceramic material were recently performed in support of NASA's Terrestrial Planet Finder Coronagraph (TPF-C) mission. The TPF-C mission is a visible light coronagraph designed to look at roughly 50 stars pre- selected as good candidates for possessing earth-like planets. Upon detection of an earth-like planet, TPF-C will analyze the visible-light signature of the planet's atmosphere for specific spectroscopic indicators that life may exist there. With this focus, the project's primary interest in PMN material is for use as a solid-state actuator for deformable mirrors or compensating optics. The nine test samples were machined from three distinct boules of PMN ceramic manufactured by Xinetics Inc. Thermal expansion measurements were performed in 2005 at NASA Jet Propulsion Laboratory (JPL) in their Cryogenic Dilatometer Facility. All measurements were performed in vacuum with sample temperature actively controlled over the range of 270K to 3 10K. Expansion and contraction of the test samples with temperature was measured using a JPL developed interferometric system capable of sub-nanometer accuracy. Presented in this paper is a discussion of the sample configuration, test facilities, test method, data analysis, test results, and future plans.

Terrestrial Planet Finder (TPF)↗

The Use of the Molecular Adsorber Coating Technology to Mitigate Vacuum Chamber Contamination During Pathfinder Testing for the James Webb Space Telescope

As a coating made of highly porous zeolite materials, the Molecular Adsorber Coating (MAC) was developed to capture outgassed molecular contaminants, such as hydrocarbons and silicones. For spaceflight applications, the adsorptive capabilities of the coating can alleviate on-orbit outgassing concerns on or near sensitive surfaces and instruments within the spacecraft. Similarly, this sprayable paint technology has proven to be significantly beneficial for ground based space applications, in particular, for vacuum chamber environments. This paper describes the recent use of the MAC technology during Pathfinder testing of the Optical Ground Support Equipment (OGSE) for the James Webb Space Telescope (JWST) at NASA Johnson Space Center (JSC). The coating was used as a mitigation tool to entrap persistent outgassed contaminants, specifically silicone based diffusion pump oil, from within JSC's cryogenic optical vacuum chamber test facility called Chamber A. This paper summarizes the sample fabrication, installation, laboratory testing, post-test chemical analysis results, and future plans for the MAC technology, which was effectively used to protect the JWST test equipment from vacuum chamber contamination.

molecular contamination↗

Life test performance of a Philips rhombic-drive refrigerator with bellows seals

In February 1979, tour Stirling cycle cryogenic refrigerators, developed by Philips Laboratories for the John Hopkins University/Applied Physics Laboratory, were launched into orbit aboard the P78-1 spacecraft. The refrigerators were designed to cool the detectors of two identical gamma-ray spectrometers to 77 K reliably for one year. Since launch, the refrigerators, still in orbit, have individually accumulated from 5,000 to over 20,000 hours of operation. As part of those efforts, a refrigerator identical to those in orbit was built, with one significant modification: flexible metal bellows between the crankcase and the working volume to prevent possible contaminants from migrating into the cold region. During the life test of the modified refrigerator, the temperature increase during the first three month run was 0.022 k/day, a negligible level. As of October 1982, the unit has accumulated over 12,300 hours of operation.

Lindale, E.↗

Fracture control of H-O engine components

An investigation was made to obtain the material characterization and fatigue crack propagation data necessary to establish the salient characteristics of a Ti-6Al-2.5Sn(ELI) alloy fuel pump impeller to be used in a cryogenic service environment. Testing variables considered were: coupon orientation, frequency, load range ratio, and temperature. Data analysis correlated crack propagation data from conventional laboratory coupons with data from a parallel sided rotating disk used to model rotor stresses. Four major design recommendations when bore regions of fuel pump impellers to be operated in cryogenic environments are to be relatively highly stressed are discussed.

Ryder, J. T.↗

Durability Characterization of Advanced Polymeric Composites at Cryogenic Temperatures

The next generation of reusable launch vehicles will require technology development in several key areas. Of these key areas, the development of polymeric composite cryogenic fuel tanks promises to present one of the most difficult technical challenges. It is envisioned that a polymer matrix composite (PMC) tank would be a large shell structure capable of containing cryogenic fuels and carrying a range of structural loads. The criteria that will be imposed on such a design include reduced weight, conformal geometry, and impermeability. It is this last criterion, impermeability, that will provide the focus of this paper. The essence of the impermeability criterion is that the tank remains leak free throughout its design lifetime. To address this criterion, one of the first steps is to conduct a complete durability assessment of the PMC materials. At Langley Research Center, a durability assessment of promising new polyimide-based PMCs is underway. This durability program has focused on designing a set of critical laboratory experiments that will determine fundamental material properties under combined thermal-mechanical loading at cryogenic temperatures. The test program provides measurements of lamina and laminate properties, including strength, stiffness, and fracture toughness. The performance of the PMC materials is monitored as a function of exposure conditions and aging time. Residual properties after exposure are measured at cryogenic temperatures and provide quantitative values of residual strength and stiffness. Primary degradation mechanisms and the associated damage modes are measured with both destructive and nondestructive techniques. In addition to mechanical properties, a range of physical properties, such as weight, glass transition, and crack density, are measured and correlated with the test conditions. This paper will report on the progress of this research program and present critical results and illustrative examples of current findings.

Gates, T. S.↗

A Comparison of Weld-Repaired and Base Metal for Inconel 718 and CRES 321 at Cryogenic and Room Temperatures

Fatigue crack growth tests were conducted to characterize the performance of Inconel 718 and CRES 321 welds, weld heat-affect-zone and parent metal at room temperature laboratory air and liquid nitrogen (-196oC) environments. The results of this study were required to predict the damage tolerance behavior of proposed orbiter main engine hydrogen fuel liner weld repairs. Experimental results show that the room and cryogenic temperature fatigue crack growth characteristics of both alloys are not significantly degraded by the weld repair process. However, both Inconel 718 and CRES 321 exhibited lower apparent toughness within the weld repair region compared to the parent metal.

Newman, John A.↗

Mixer conditions temperature of liquified gas streams

Room temperature gaseous hydrogen mixed with liquified hydrogen in a venturi produces a two- phased liquid hydrogen stream at a stable temperature. This technique is useful in laboratory testing where presently, temperature control is maintained by a calibrated heat leak that results in considerable expenditure of cryogenic refrigerants.

Talmor, E.↗

Vibration-Heating in ADR Kevlar Suspension Systems

The cryogenics group at NASA's Goddard Space Flight Center has a long-standing development and test program for laboratory and space-flight adiabatic demagnetization refrigerators (ADRs). These devices are used to cool components to temperatures as low as 0.05 K. At such low temperatures the ADR systems can provide a few micro-Watts of cooling power, so it is important to minimize the conduction of heat to these cold stages from the surroundings. The cold ADR elements are held in place by thin tensioned strings made of Kevlar, chosen for its high strength and stiffness and low thermal conductivity. During laboratory testing, we have observed that occasional significant additional heat loads on the coldest ADR stages correlate with unusually high vibration levels in the cryostat due to a noisy mechanical cryocooler. We theorized that this heat results from plastic deformation of the Kevlar fibers and frictional interactions among them, driven by the cryostat vibrations. We describe tests and calculations performed in attempt to confirm this source of the heating, and we discuss possible strategies to reduce this effect in future ADR suspension systems.

Vibration-heating↗

Design, Fabrication, and Test of a LOX/LCH4 RCS Igniter at NASA

A workhorse liquid oxygen-liquid methane (LOX/LCH4) rocket igniter was recently tested at NASA Glenn Research Center s (GRC) Research Combustion Laboratory (RCL). These tests were conducted in support of the Reaction Control Engine (RCE) development task of the Propulsion and Cryogenics Advanced Development (PCAD) project. The igniter was a GRC in-house design used to evaluate the ignition processes for LOX/LCH4. The test matrix was developed to examine the flammability of LOX/LCH4 over a range of oxidizer-to-fuel mixture ratios, both in the core fuel flow and total flow. In addition, testing also examined the durability of the hardware by accumulating ignition pulses. Over the course of testing, a total of 1402 individual ignition pulses were successfully demonstrated over the range of mixture ratios. Testing was halted after the failure of the ceramic in the igniter spark plug.

Schneider, Steven J.↗

Unlined Reuseable Filament Wound Composite Cryogenic Tank Testing

An unlined reusable filament wound composite cryogenic tank was tested at the Marshall Space Flight Center using LH2 cryogen and pressurization to 320 psig. The tank was fabricated by Phillips Laboratory and Wilson Composite Group, Inc., using an EnTec five-axis filament winder and sand mandrels. The material used was IM7/977-2 (graphite/epoxy).

Murphy, A. W.↗

Precise Measurements of the Density and Critical Phenomena Near Phase Transitions in Liquid Helium

The first-year progress for the project of precise measurements of the density and critical phenomena of helium near phase transitions is summarized below: (1) completion of a cryogenic sample probe for the proposed measurements, and the rehabilitation of a designated laboratory at Caltech for this project; (2) construction and testing of a superconducting niobium cavity; (3) acquisition of one phase-locked-loop system for high-resolution frequency control and read- out; (4) setting up high-resolution thermometry (HRT) for temperature readout and control; (5) developing new approaches for calibrating the coefficient between the resonant frequency shift (delta f) and the helium density (rho), as well as for measuring the effect of gravity on T(sub lambda) to a much better precision; (6) programming of the interface control of all instruments for automatic data acquisition; and (7) improving data analyses and fitting procedures.

Yeh, Nai-Chang↗

Aerogel-Based Insulation Materials for Cryogenic Applications

Many different aerogel-based materials are now being used in thermal insulation systems for cryogenic applications. These materials include flexible composite blankets, bulk-fill particles, and polymer composites in both evacuated and non-evacuated environments. In ambient environments, aerogels provide superior thermal performance compared to conventional polymeric foam and cellular glass insulations while offering unique advantages in avoiding problems with weathering, moisture, and mechanical damage. Aerogels are also used as spacer materials in multilayer insulation systems. These layered systems provide combined structural-thermal capability for cryogenic systems in either vacuum-jacketed or externally-applied insulation designs. Test data (effective thermal conductivity) include a wide range of both commercial and experimental aerogel materials. Testing was performed using laboratory cryostats and standard methods including full range vacuum (from ambient pressure to high vacuum) and boundary temperatures 293 K and 78 K. Examples of aerogel-based insulation systems are given for both evacuated and non-evacuated applications.

heat transfer↗

Development and Testing of Cooled CMCs for High Thermal Flux Applications

Ceramic Matrix Composites (CMCS) offer the potential for significant weight savings and improved performance for a range of propulsion components utilizing refractory materials. This paper describes the fabrication and testing of functionally graded CMCs produced via a low cost process that represents an order of magnitude cost savings over conventionally fabricated CMCS. Test cylinders were fabricated, characterized and evaluated during exposure to high thermal fluxes of up to 10MW/meters squared at the Laser Hardened Materials Evaluation Laboratory (LHMEL). The bulk density of the CMC tubes was approximately 2.2 grams per cubic centimeters. The performance of cryogenically cooled CMCs was compared with uncooled CMCs against similar thermal loads, and fundamental property data collected for this relatively new breed of CMC. Finally, test thrust cells were fabricated from the functionally graded composite and tested using liquid H2 and O2 propellants at NASA Glen.

Patterson , Mark↗